In present are electrical boxes cooled by air through the intake hole on the bottom electrical box to the box space with electrotechnical elements and exhaust through the hole at the top to the surrounding by natural convection. This cooling method is effective but operate with the risk of contamination electrotechnical elements by dust sucking from surrounding air. The goal of this work is solution of the dustproof cooling of the electrical box by natural convection. The work deal with design of the device with the heat transfer by the phase change of the working fluid and experimental measuring its thermal performance at the cooling electrotechnical elements loaded by heat 1 200 W in the dustproof electrical box.

2020 ◽  
Vol 92 (3) ◽  
pp. 30901
Author(s):  
Suvanjan Bhattacharyya ◽  
Debraj Sarkar ◽  
Ulavathi Shettar Mahabaleshwar ◽  
Manoj K. Soni ◽  
M. Mohanraj

The current study experimentally investigates the heat transfer augmentation on the novel axial corrugated heat exchanger tube in which the spring tape is introduced. Air (Pr = 0.707) is used as a working fluid. In order to augment the thermohydraulic performance, a corrugated tube with inserts is offered. The experimental study is further extended by varying the important parameters like spring ratio (y = 1.5, 2.0, 2.5) and Reynolds number (Re = 10 000–52 000). The angular pitch between the two neighboring corrugations and the angle of the corrugation is kept constant through the experiments at β = 1200 and α = 600 respectively, while two different corrugations heights (h) are analyzed. While increasing the corrugation height and decreasing the spring ratio, the impact of the swirling effect improves the thermal performance of the system. The maximum thermal performance is obtained when the corrugation height is h = 0.2 and spring ratio y = 1.5. Eventually, correlations for predicting friction factor (f) and Nusselt number (Nu) are developed.


2019 ◽  
Vol 7 (1) ◽  
pp. 43-53
Author(s):  
Abbas Jassem Jubear ◽  
Ali Hameed Abd

The heat sink with vertically rectangular interrupted fins was investigated numerically in a natural convection field, with steady-state heat transfer. A numerical study has been conducted using ANSYS Fluent software (R16.1) in order to develop a 3-D numerical model.  The dimensions of the fins are (305 mm length, 100 mm width, 17 mm height, and 9.5 mm space between fins. The number of fins used on the surface is eight. In this study, the heat input was used as follows: 20, 40, 60, 80, 100, and 120 watts. This study focused on interrupted rectangular fins with a different arrangement and angle of the fins. Results show that the addition of interruption in fins in various arrangements will improve the thermal performance of the heat sink, and through the results, a better interruption rate as an equation can be obtained.


Author(s):  
Yasmin Khakpour ◽  
Jamal Seyed-Yagoobi

This numerical study investigates the effect of using a blend of micro-encapsulated phase change materials (MEPCMs) on the heat transfer characteristics of a liquid in a rectangular enclosure driven by natural convection. A comparison has been made between the cases of using single component MEPCM slurry and a blend of two-component MEPCM slurry. The natural convection is generated by the temperature difference between two vertical walls of the enclosure maintained at constant temperatures. Each of the two phase change materials store latent heat at a specific range of temperatures. During phase change of the PCM, the effective density of the slurry varies. This results in thermal expansion and hence a buoyancy driven flow. The effects of MEPCM concentration in the slurry and changes in the operating conditions such as the wall temperatures compared to that of pure water have been studied. The MEPCM latent heat and the increased volumetric thermal expansion coefficient during phase change of the MEPCM play a major role in this heat transfer augmentation.


Author(s):  
C. J. Ho ◽  
Chi-Ming Lai

Experiments were conducted to investigate the heat transfer characteristics of water-based suspensions of phase change nanocapsules in a natural circulation loop with mini-channel heat sinks and heat sources. A total of 23 and 34 rectangular mini-channels, each with width 0.8 mm, depth 1.2 mm, length 50 mm and hydraulic diameter 0.96 mm, were evenly placed on the copper blocks as the heat source and heat sink, respectively. The adiabatic sections of the circulation loop were constructed using PMMA tubes with an outer diameter of 6 mm and an inner diameter of 4 mm, which were fabricated and assembled to construct a rectangular loop with a height of 630 mm and a width of 220 mm. Using a core material of n-eicosane and a shell of urea-formaldehyde resin, the phase change material nanocapsules of mean particle size 150 nm were fabricated successfully and then dispersed in pure water as the working fluid to form the water-based suspensions with mass fractions of the nanocapsules in the range 0.1–1 wt.%. The results clearly indicate that water-based suspensions of phase change nanocapsules can markedly enhance the heat transfer performance of the natural circulation loop considered.


Energies ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 8593
Author(s):  
Muneerah Al Nuwairan ◽  
Basma Souayeh

This numerical investigation presents the effects of the position of baffles in the shape of a circle’s segment placed inside a circular channel to improve the thermal and flow performance of a solar air heater. Three different baffles’ positions with Reynolds number varying between 10,000 to 50,000 were investigated computationally. The k-omega SST model was used for solving the governing equations. Air was taken as the working fluid. Three pitch ratios (Y = 3, 4, and 5) were considered, while the height of the baffles remained fixed. The result showed an enhancement in Nusselt number, friction factor, j-factor, and thermal performance factor. Staggered exit-length baffles showed maximum enhancement in heat transfer and pressure drop, while inline inlet-length baffles showed the least enhancement. For a pitch ratio of Y = 3.0, the enhancement in all parameters was the highest, while for Y = 5.0, the enhancement in all parameters was the least. The highest thermal performance factor of 1.6 was found for SEL at Y = 3.0.


1984 ◽  
Vol 106 (1) ◽  
pp. 106-111 ◽  
Author(s):  
D. Dietz

The thermal performance of an air-heated/cooled, phase-change, heat stoage module was tested and evaluated. The module (rated at 38.7 kWh) consist of 130 vertically oriented tubes filled with 729 kg (1607 lb) of calcium chloride hexahydrate and enclosed in a rectangular box. Heat transfer rates measured during charging and discharging decreased with time as a result of decreasing effective heat transfer area and increasing thermal resistance of the phase-change material. These two dominant effects are included in a proposed mathematical model that predicted the experimental data.


Author(s):  
Hamza Faraji ◽  
Mustapha Faraji ◽  
Mustapha El Alami

Abstract The present paper reports numerical results of the melting driven natural convection in an inclined rectangular enclosure filled with nano-enhanced phase change material (NePCM). The enclosure is heated from the bottom side by a flush-mounted heat source (microprocessor) that generates heat at a constant and uniform volumetric rate and mounted on a substrate (motherboard). All the walls are considered adiabatic. The purpose of the investigation is analyzing the effect of nanoparticles insertion by quantifying their contribution to the overall heat transfer. Combined effects of the PCM type, the inclination angle and the nanoparticles fraction on the structure of the fluid flow and heat transfer are investigated. A 2D mathematical model based on the conservation equations of mass, momentum, and energy was developed. The governing equations were integrated and discretized using the finite volume method. The SIMPLE algorithm was adopted for velocity–pressure coupling. The obtained results show that the nanoparticles insertion has an important quantitative effect on the overall heat transfer. The insertion of metallic nanoparticles with different concentrations affects the thermal behavior of the heat sink. They contribute to an efficient cooling of the heat source. The effect of nanoparticles insertion is also shown at the temperature distribution along the substrate.


Author(s):  
Manjinder Singh ◽  
Naresh Varma Datla ◽  
Supreet Singh Bahga ◽  
Sasidhar Kondaraju

Continuous increase in the integration density of microelectronic units necessitates the use of MHPs with enhanced thermal performance. Recently, the use of wettability gradients have been shown to enhance the heat transfer capacity of MHPs. In this paper, we present an optimization of axial wettability gradient to maximize the heat transfer capacity of the MHP. We use an experimentally validated mathematical model and interior point method to optimize the wettability gradient. For our analysis, we consider two cases wherein (i) the mass of working fluid is constrained, (ii) mass of working fluid is a design variable. Compared to MHP with uniform high wettability and filled with a fixed mass of working fluid, optimization of the wettability gradient leads to 65% enhancement in heat transfer capacity. Similar comparisons for MHP filled with variable mass of working fluid shows more than 90% increase in the maximum heat transfer capacity due to optimization of wettability gradient.