scholarly journals 78 Evaluation of extended hair sheep ram semen stored as liquid at 5°C

2020 ◽  
Vol 98 (Supplement_2) ◽  
pp. 74-75
Author(s):  
Robert W Godfrey ◽  
Sabrina Keiper ◽  
Sue Lakos

Abstract This study was designed to evaluate the quality of extended hair sheep ram semen stored as a liquid at 5°C. St Croix White (STX; n = 6) and Dorper x STX (DRPX, n = 5) rams were collected weekly for 3 wk using estrus ewes fitted with an intravaginal collection vial. Semen was kept at 32°C during transport to the lab and during processing. Semen was evaluated for percent motility (MOT), viability (LIVE) using eosin-nigrosin stain and concentration using a hemocytometer counting chamber. Semen was extended to a final concentration of 250 x 106/mL in a one-step dilution with a skim UHT milk extender with 10% egg yolk by volume and packaged into 0.5 mL straws. Straws were stored in a styrofoam box in a refrigerator at 5°C for 96 h, or in an Equitainer® set up using the manufacturer’s instructions, for 24 h at which time they were transferred to the styrofoam box in the refrigerator for 72 h. Semen was evaluated for MOT and LIVE at -1, 0, 24, 48 72 and 96 h relative to cooling. Semen traits were analyzed using GLM of SAS for repeated measures with ram, time, breed and cooling method in the model. There was no difference (P > 0.10) in MOT or LIVE over time between breeds or cooling method. One STX ram did not produce any samples that survived extension; one STX and four DRPX rams produced at least one sample that did not survive extension and all were removed from analysis. The MOT decreased (P < 0.0001) from 81.7 ± 2.9 % at -1 h to 52.2 ± 2.9% at 96 h. The LIVE decreased (P < 0.0001) from 83.1 ± 3.6% at -1 h to 50.4 ± 3.6% at 96 h. These results show that ram semen stored as a liquid at 5°C can maintain motility and viability for 96 h. Further studies will be conducted to evaluate cooling of extended ram semen and fertility after artificial insemination.

Animals ◽  
2020 ◽  
Vol 10 (4) ◽  
pp. 653
Author(s):  
Maja Zakošek Pipan ◽  
Margret L. Casal ◽  
Nataša Šterbenc ◽  
Irma Virant Klun ◽  
Janko Mrkun

A challenge in freezing semen for short and long-term availability is avoiding damage to intact spermatozoa caused by the freezing process. Vitrification protocols provide better results through less manipulation of semen and shorter freezing time compared to slow freezing techniques. Our research was aimed at improving vitrification methods for canine semen. Semen quality was determined in 20 ejaculates after collection. Each ejaculate was divided into eight aliquots, each with a different extender. The control extender contained TRIS, citric acid, fructose, and antibiotics. Soy lecithin and sucrose were added to the control extender at different concentrations to make up the test extenders and final concentration of 50 × 106 spermatozoa/mL. From each group, a 33 µL (1.65 × 106 spermatozoa) suspension of spermatozoa was dropped directly into liquid nitrogen and devitrified at least one week later and evaluated as before. Soy lecithin at 1% and 0.25 M sucrose added to the base vitrification media effectively preserved all sperm qualities. Our results demonstrate the effectiveness of our methods. Vitrification media containing sucrose and soy lecithin cause a minimal decline in quality of canine semen after devitrification. Furthermore, extenders used in our research did not contain egg yolk, which was replaced by soy lecithin, thus allowing for ease of shipping to other countries with strict requirements.


2014 ◽  
Vol 45 (1) ◽  
pp. 32 ◽  
Author(s):  
Raffaele Cavalli ◽  
Stefano Grigolato ◽  
Andrea Sgarbossa

The growing interest about wood as fuel regards not only wood chips and pellets but also firewood, especially in mountain and rural areas where domestic heating plants are widely used. Due to the increased demand for firewood, harvesting activities have extended on broadleaved high forests as well as coppice. As a consequence, the diameter of logs has increased requiring larger and larger splitting machines; nowadays it is not uncommon to find on the market splitters able to process logs with diameter up to 50-60 cm. In order to increase the productivity, the effort of machine producers is directed to obtain the complete splitting of the log into firewood in only one step using multiple ways splitting knives. This technical solution may cause some drawbacks especially when the splitting knives are not properly adapted to the log diameter; it happens that the size of firewood is not homogeneous and splinters are produced, which requires using screens to separate them from the main product. In order to evaluate the work quality of a firewood processor, equipped with multiple ways splitting knives, an experimental test has been carried out using a machine in which the log diameter is automatically detected through a laser device; according to the log diameter the multiple ways splitting knives (formed by fixed and mobile knives, the latter hydraulically operated) is properly set up to obtain regularly sized firewood. Furthermore the log is automatically centred on the splitting knife set-up. The results of the experimental test showed that the firewood processor is able to produce firewood with homogeneous size and with a low production of splinters, regardless of log diameter.


2013 ◽  
Vol 25 (1) ◽  
pp. 175
Author(s):  
L. Alcaráz ◽  
M. Hidalgo ◽  
M. J. Galvez ◽  
D. Acha ◽  
I. Ortiz ◽  
...  

Density gradient centrifugation with PureSperm® (PureSperm® 40 + PureSperm® 80; Nidacon International, Mölndal, Sweden) has been satisfactorily used to enhance the quality of dog semen samples; however, no studies have been performed on the effect of single layer centrifugation (SLC) with PureSperm® on frozen–thawed dog semen. The aim of this study was to investigate if SLC with PureSperm® 80 can improve the post-thaw semen quality of dog. Semen from 5 dogs was collected by digital manipulation. Two ejaculates from each dog were centrifuged with Tris-based extender, supernatant was removed, and sperm pellet was suspended to a final concentration of 300–400 × 106 sperm mL–1 with CaniPROTM Freeze A plus 20% egg yolk at 22°C. Extended semen was cooled to 5°C within an hour and then diluted to a final concentration of 150–200 × 106 sperm mL–1 in CaniPROTM Freeze B plus 20% egg yolk at 5°C, loaded in 0.5-mL plastic straws and frozen horizontally in ranks placed 4 cm above the surface of liquid nitrogen vapors for 10 min, after which they were directly placed in liquid nitrogen. After 24 to 48 h of storage, straws were thawed in a water bath at 37°C for 30 s. After thawing, semen samples were divided in 2 aliquots: one of them was used as control and the other one was processed by SLC PureSperm® 80. Assessment of sperm motility (assessed by computerized-assisted semen analysis), morphology (Diff-Quick staining), and viability [triple fluorescent stain of propidium iodine/isothiocyanate-labeled peanut (Arachis hypogaea) agglutinin/Rhodamine 123] were evaluated in control and treated semen samples. Data were studied by ANOVA. Results are expressed as mean ± SEM. Significant (P < 0.001) differences were found between SLC-treated and control semen for sperm motility (percentage of total motile spermatozoa: 93.65 ± 0.05 v. 83.79 ± 0.13; percentage of progressive motile spermatozoa: 79.38 ± 6.66 v. 54.61 ± 16.11), morphology (86.45 ± 0.01 v. 83.51 ± 0.01), and viability (percentage of viable sperm with an intact acrosome: 58.32 ± 0.04 v. 36.50 ± 0.17; percentage of viable sperm with an acrosome reaction: 2.81 ± 0.01 v. 9.74 ± 0.21). Based on our results, we can conclude that SLC with PureSperm® 80 is an alternative and successful method for improving the quality of frozen–thawed dog spermatozoa, selecting good-quality spermatozoa (motile, morphologically normal, viable, and acrosome intact spermatozoa) from the rest of the semen sample.


2020 ◽  
Vol 7 (2) ◽  
pp. 235-241
Author(s):  
Pankaj Kumar Jha ◽  
M Golam Shahi Alam ◽  
Farida Yeasmin Bari

The effect of freezing methods and diluents types on post-thaw sperm quality of Bangladeshi ram semen was studied. Two freezing methods and three diluents was tested as pooling effects (freezing methods or diluents) on post-thaw sperm parameters; sperm motility (SM), viability (SV), plasma membrane integrity (SPMI) and acrosome integrity (SAI), respectively. From selected ten rams, eight ejaculates were used for each freezing group (freezing methods × diluents). Semen samples were diluted by using two-steps for hand-made tris-based diluents (20% egg yolk): D1 (7% glycerol) and D2 (5% glycerol), and one-step dilution for commercial diluents: D3 (Triladyl®) at 35°C. After 4h of equilibration of temperature at 5°C, diluted semen samples was aspirated into 0.25 mL straws, and sealed. Straws were frozen in liquid nitrogen (LN2) vapour using two methods: F1 (manually in Styrofoam box, using three-steps method; +5°C to -80°C at -11.33°C/min, -80°C to -120°C at -26.66°C/min, and -120°C to -140°C at - 13.33°C/min) and F2 (programmable bio-freezer, using two-steps method; +5°C to -100°C at - 20°C/min and -100°C to -140°C at -10°C/min). Two semen straws from each batch were evaluated (37°C for 20 sec) for sperm parameters. In pool effects between freezing methods; SAI differed significantly (P < 0.001). The SM (56%) and SV (72%) were observed competitive. However, SPMI (67.58 ± 2.02%) and SAI (76.13 ± 1.42%) were higher in F1. Among diluents, SM (P < 0.006), SV (P < 0.008), SPMI (P < 0.012) and SAI (P < 0.019) differed significantly. The SM (61.25 ± 1.80%), SV (77.13 ± 1.47%), SPMI (68.31 ± 1.91%) and SAI (74.75 ± 1.64%) were highest in D3. In conclusion, the combination of manual freezing (three-steps) and handmade tris-based diluents (20% egg yolk, 5% glycerol) is suitable and sustainable method for cryopreservation of ram semen. Res. Agric., Livest. Fish.7(2): 235-241,  August 2020


2020 ◽  
Vol 13 (11) ◽  
pp. 2422-2428
Author(s):  
Ani Atul Arif ◽  
Tulus Maulana ◽  
Ekayanti Mulyawati Kaiin ◽  
Bambang Purwantara ◽  
Raden Iis Arifiantini ◽  
...  

Background and Aim: Indonesia has two National Artificial Insemination centers and 17 Regional Artificial Insemination Centers. The frozen semen production techniques differed between the centers, including the type of diluent and semen dilution technique. The aim of the research was to compare the quality of frozen Limousin bull semen diluted using different techniques. Materials and Methods: Semen was collected from three sexually mature Limousin bulls using an artificial vagina. Immediately after collection, the semen was evaluated macroscopically and microscopically. Semen that had >70% motile sperm and <20% sperm abnormality was divided into three tubes and diluted with skim milk-egg yolk (SMEY) using three different dilution techniques: One-step dilution (100% SMEY with 8% glycerol) at room temperature ([RT] 20°C until 25°C) two-step dilution (50% SMEY without glycerol at RT, stored at 5°C; and 50% SMEY with 16% glycerol after 1 h stored at 5°C); and three-step dilution (50% SMEY without glycerol at RT, stored at 5°C; and 50% SMEY with 16% glycerol added twice at 1 h and 1.5 h after being stored at 5°C). The diluted semen was loaded into 0.25 mL mini straws, equilibrated, and frozen using a freezing machine. Sperm motility, viability, membranes, DNA integrity, and concentrations of malondialdehyde (MDA) and aspartate aminotransferase (AST) enzymes were evaluated after thawing. Results: The results showed that there were no significant differences in sperm motility and DNA integrity between dilutions (p>0.05). However, sperm viability and membrane intactness of one-step dilutions were higher than those of three-step dilutions. The concentrations of MDA and AST enzymes of sperm in one-step dilutions were lower than those of three-step dilutions (p<0.05). Conclusion: It was concluded that the one-step-dilution technique was better than three-step dilution for cryopreservation of Limousin bull semen.


2013 ◽  
Vol 25 (3) ◽  
pp. 587
Author(s):  
L. Alcaráz ◽  
M. Hidalgo ◽  
M. J. Galvez ◽  
D. Acha ◽  
I. Ortiz ◽  
...  

Density gradient centrifugation with PureSperm® (PureSperm® 40+PureSperm® 80; Nidacon International, Mölndal, Sweden) has been satisfactorily used to enhance the quality of dog semen samples; however, no studies have been performed on the effect of single layer centrifugation (SLC) with PureSperm® on frozen–thawed dog semen. The aim of this study was to investigate if SLC with PureSperm® 80 can improve the post-thaw semen quality of dog. Semen from 5 dogs was collected by digital manipulation. Two ejaculates from each dog were centrifuged with Tris-based extender, supernatant was removed, and sperm pellet was suspended to a final concentration of 300–400×106spermmL–1 with CaniPROTM Freeze A plus 20% egg yolk at 22°C. Extended semen was cooled to 5°C within an hour and then diluted to a final concentration of 150–200×106spermmL–1 in CaniPROTM Freeze B plus 20% egg yolk at 5°C, loaded in 0.5-mL plastic straws and frozen horizontally in ranks placed 4cm above the surface of liquid nitrogen vapors for 10min, after which they were directly placed in liquid nitrogen. After 24 to 48h of storage, straws were thawed in a water bath at 37°C for 30s. After thawing, semen samples were divided in 2 aliquots: one of them was used as control and the other one was processed by SLC PureSperm® 80. Assessment of sperm motility (assessed by computerized-assisted semen analysis), morphology (Diff-Quick staining), and viability [triple fluorescent stain of propidium iodine/isothiocyanate-labeled peanut (Arachis hypogaea) agglutinin/Rhodamine 123] were evaluated in control and treated semen samples. Data were studied by ANOVA. Results are expressed as mean ± SEM. Significant (P&lt;0.001) differences were found between SLC-treated and control semen for sperm motility (percentage of total motile spermatozoa: 93.65±0.05 v. 83.79±0.13; percentage of progressive motile spermatozoa: 79.38±6.66 v. 54.61±16.11), morphology (86.45±0.01 v. 83.51±0.01), and viability (percentage of viable sperm with an intact acrosome: 58.32±0.04 v. 36.50±0.17; percentage of viable sperm with an acrosome reaction: 2.81±0.01 v. 9.74±0.21). Based on our results, we can conclude that SLC with PureSperm® 80 is an alternative and successful method for improving the quality of frozen–thawed dog spermatozoa, selecting good-quality spermatozoa (motile, morphologically normal, viable, and acrosome intact spermatozoa) from the rest of the semen sample.


2019 ◽  
Vol 6 (1) ◽  
pp. 78
Author(s):  
Muhammad Ade Salim ◽  
Muhammad Nur Ihsan ◽  
Nur Isnaini ◽  
Trinil Susilawati

ABSTRAKAir kelapa muda varietas viridisdapat dijadikan pengencer aletrnatif semen cair bagi program IB di daerah minim sarana semen beku. Tujuan penelitian ini untuk menguji pengaruh penggunaan air kelapa muda viridissebagai bahan pengencer terhadap kualitas semen cair kambing Boer setelah didinginkan. Dilaksanakanselama 3 bulan di Laboratorium Fakultas Peternakan UBUnit SumberSekar,Malang. Metodenya yaitu eksperimen. Semen dari  3 pejantan Boer umur 3-5 tahun, dikoleksi seminggu sekali dengan VB. Air kelapa mudaviridis umur 5-7 bulan serta tris aminomethane sebagai kontrol. Didesain menggunakan Rancangan Acak Kelompok (RAK) dengan 2 perlakuan yaitu P0 (tris aminomethane + 10% KT) dan  P1 (air kelapa muda viridis + 10% KT) masing-masing diulang 10 kali. Data dianalisis dengan analisis Ragam (Anova) dengan software Genstat 18. Variabelnya yaitu motilitas individu, viabilitas dan abnormalitas. Hasil penelitian yaitu motilitas individu pada P1bertahan sampai 4 hari (40,5± 24,3%), viabilitas terbaik sampai hari ke-5 (42±24,6%), abnormalitas terendah di hari ke-7(1,31± 0,6). Kesimpulannya, Pengencer air kelapa muda viridis dapat mempertahankan kualitas semen cair kambing Boer selama 4 hari untuk motilitas dan 5 hari untuk viabilitas.Kata Kunci:pengencer, air kelapa, varietas viridisABSTRACTYoung viridis coconut water could be used as an alternative to liquid semen diluent for artificial insemination program in the area with limited facility for frozen semen production. This study evaluated the use of young coconut water as a diluent on liquid semen quality of Boer goat after cold storage. This study was carried out for 3 months at Sumber Sekar Laboratory, Faculty of Animal Husbandry, University of Brawijaya, Malang. The semen was collected from 3 Boer bucks aged at 3 to 5 years old. The semen collection was done once a week with the aid of artificial vagina. The diluents used were young Viridis coconut (5 to 7 months old) and tris aminomethane. The method used was an experiment in a randomized block design with 2 treatments and 10 replicates. The treatments used were T0: tris aminomethane + 10% egg yolk (control) and T1:  young Viridis coconut water + 10% egg yolk. Data were analyzed by analysis of variance using Genstat 18 software. The variables measured were sperm individual motility, viability, and abnormality. The results showed that the sperm individual motility in T1 survived up to 4 days (40.5± 24.3%), the best viability at 5 days (42.0±24.6%),  while the lowest abnormality at 7 days (1.31±0.6). It could be concluded that: 1. Tris aminomethane diluent has higher quality with the storage length up to 9 days, 2. Young Viridis coconut water diluent could preserve liquid semen quality of Boer goat up to 4 days for sperm motility and 5 days for sperm viability.Keywords: diluents, coconut water, viridis variety


At production of fabrics, including fabrics for agricultural purpose, an important role is played by the cor-rect adjustment of operation of machine main regulator. The quality of setup of machine main controller is determined by the proper selection of rotation angle of warp beam weaving per one filling thread. In the pro-cess of using the regulator as a result of mistakes in adjustment, wear of transmission gear and backlashes in connections of details there are random changes in threads length. The purpose of the article is the research of property of random errors of basis giving by STB machine regulator. Mistakes can be both negative, and positive. In case of emergence only negative or only positive mistakes operation of the machine becomes im-possible as there will be a consecutive accumulation of mistakes. As a result of experimental data processing for stable process of weaving and the invariable diameter of basis threads winding of threads it is revealed that the random error of giving is set up as linear function of the accidental length having normal distribution. Measurements of accidental deviations in giving of a basis by the main regulator allowed to construct a curve of normal distribution of its actual length for one pass of weft thread. The presented curve of distribution of random errors in giving of a basis is the displaced curve of normal distribution of the accidental sizes. Also we define the density of probability of normal distribution of basis giving errors connected with a margin er-ror operation of the main regulator knowing of which allows to plan ways of their decrease that is important for improvement of quality of the produced fabrics.


1991 ◽  
Vol 24 (10) ◽  
pp. 171-177
Author(s):  
T. Vellinga ◽  
J. P. J. Nijssen

Much of the material dredged from the port of Rotterdam is contaminated to such a degree that it must be placed in specially constructed sites. The aim of Rotterdam is to ensure that the dredged material will once again be clean. This will entail the thorough cleansing of the sources of the contamination of the sediment in the harbours and in the River Rhine. The Rotterdam Rhine Research Project (RRP) is one of the means to achieve this based on: technical research, legal research, public relations and dialogues with dischargers. The programme for five selected heavy metals is almost complete. For many heavy metal discharge points between Rotterdam and Rheinfelden, a specially devised independent load assessment has been carried out four times. Balance studies were used to determine the relative contributions of the point discharges to the total. Currently the results are being used in an attempt to negotiate agreements with a selected number of the major dischargers. At present, more detailed balance studies are being set up and exploratory measurements carried out for organic micropollutants. It may be concluded that the research is progressing successfully and methods and techniques developed seem satisfactory and broadly applicable. The Rhine Action Programme encompasses an international effort to improve the quality of the Rhine water. Although the RRP plays a modest complementary role to the Rhine Action Plan, there is no doubt of the value of this Rotterdam initiative. The mode of work followed in the RRP contains elements that can be of use in combatting the contamination of the North Sea by rivers other than the Rhine.


Sign in / Sign up

Export Citation Format

Share Document