Influence of pH level of artificial saliva on corrosion behavior and nickel ion release of a Ni-Cr-Mo alloy: an in vitro study

2019 ◽  
Vol 66 (6) ◽  
pp. 746-756 ◽  
Author(s):  
Elnaz Moslehifard ◽  
Sanaz Ghasemzadeh ◽  
Farzad Nasirpouri

Purpose The purpose of this paper (in vitro) study was to determine the effect of pH of artificial saliva on the corrosion behavior of a Ni-Cr-Mo alloy at 37 ± 1°C. Design/methodology/approach The corrosion behavior of a commercially available Ni-Cr-Mo base dental alloy was studied by potentiodynamic polarization and electrochemical impedance spectroscopy techniques. The effect of pH on corrosion and Ni ion release was also investigated by scanning electron microscopy and atomic absorption spectroscopy. Findings The results suggested that the order of corrosion rate was: pH3 > pH5 > pH9 > pH7. Corrosion rate in pH3 was significantly different with other pH levels. Nickel depletion significantly occurred in alloy without passivation. The corrosion resistance and ion release of Ni-Cr-Mo alloys in different pH levels of artificial saliva depended on the stability of the passive layer. Acidic pH level severely corrodes Ni-Cr-Mo base metal alloys and increases Ni ion release. Originality/value This manuscript describes the relationship between corrosion rate and nickel ion release of a dental Ni-Cr-Mo base alloy as a function of saliva pH examined by electrochemical impedance spectroscopy (EIS), polarization, scanning electron microscopy and energy dispersive X-ray spectroscopy in artificial saliva. The main novelty of this work includes the material/structure/corrosion relationship in artificial saliva with different pH. This property would be very interesting for dental materials applications and clinical dentistry.

2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Guiyang Wu ◽  
Xikui Gu ◽  
Wanwei Zhao ◽  
Rui Fan ◽  
Ting Mao

Purpose This paper aims to study the effect of chloride ions concentration on the corrosion behavior of carbon steel in methyldiethanolamine (MDEA) aqueous solution in the sight of different process parameters of purification plant. Design/methodology/approach Due to the decrease of filtration efficiency and separation efficiency, the chloride ion in the desulfurization solution is enriched. The corrosion behavior of carbon steel under chloride ion enrichment environment was studied by weight-loss method, electrochemical impedance spectroscopy, cyclic polarization curve, X-ray photoelectron spectroscopy and scanning electron microscopy. Findings The results show that temperature and hydrogen sulfide loads are the main factors of corrosion in CO2-MDEA-H2O-H2S environment. The enrichment of chloride ions reduces the corrosion rate at low temperature but promotes the corrosion rate at high temperature. The chloride concentration should be controlled below 3000 mg/L, and no pitting corrosion was found under the experimental conditions. Originality/value The effect of chloride ion enrichment on MDEA solution corrosion shows that at low temperature, the increase of chloride ion will reduce the acid gas load and increase the density of corrosion products, so as to reduce the corrosion; on the contrary, at high temperature, the density of corrosion products will decrease and the corrosion will be intensified as well. It is believed that the chloride ion should be controlled below 3000 mg/L according to the results of the tests.


Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 7069
Author(s):  
Dessy Rachmawati ◽  
Devanti Ayu Cahyasari ◽  
Ardin Tito Febiantama ◽  
Lusi Hidayati ◽  
Cornelis Johannes Kleverlaan

Alloys in oral cavity always interact with dynamic oral environment, such as pH, temperature, salivary conditions, and dietary habits. Coffee can further decrease pH in the oral cavity. Thus, coffee may increase the release of metal ions that may lead to various health diseases. This study aimed to quantitively investigate the effect of brewed Robusta coffee on the nickel ion release and their morphological structures; Methods: 20 alloy specimens were divided into 4 groups and placed in solutions for 48 and 168 h: (1) distilled water, (2) artificial saliva, (3) Robusta coffee, and (4) mixture of artificial saliva and Robusta coffee. AAS, XRF, and SEM were used for examinations; Results: The release of Ni2+ was found in all groups and robust release were found in the coffee only and mixture of coffee + artificial saliva solution after 168 h. Likewise, SEM showed that internal oxidation was high after 168 h of immersion; Conclusions: The concentration of nickel increased in saliva of low pH due to brewed coffee. Though the release of these ions is still within the tolerable amount in human body, it should be realized that it usually lasts for months or years. Dentists should be cautious when using instructions for patients with a history of allergies especially for dietary with low acidity.


Author(s):  
Ann Chidester Van Orden ◽  
John L. Chidester ◽  
Anna C. Fraker ◽  
Pei Sung

The influence of small variations in the composition on the corrosion behavior of Co-Cr-Mo alloys has been studied using scanning electron microscopy (SEM), energy dispersive x-ray analysis (EDX), and electrochemical measurements. SEM and EDX data were correlated with data from in vitro corrosion measurements involving repassivation and also potentiostatic anodic polarization measurements. Specimens studied included the four alloys shown in Table 1. Corrosion tests were conducted in Hanks' physiological saline solution which has a pH of 7.4 and was held at a temperature of 37°C. Specimens were mechanically polished to a surface finish with 0.05 µm A1203, then exposed to the solution and anodically polarized at a rate of 0.006 v/min. All voltages were measured vs. the saturated calomel electrode (s.c.e.).. Specimens had breakdown potentials near 0.47V vs. s.c.e.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Yucong Ma ◽  
Mohd Talha ◽  
Qi Wang ◽  
Zhonghui Li ◽  
Yuanhua Lin

Purpose The purpose of this paper is to study systematically the corrosion behavior of AZ31 magnesium (Mg) alloy with different concentrations of bovine serum albumin (BSA) (0, 0.5, 1.0, 1.5, 2.0 and 5.0 g/L). Design/methodology/approach Electrochemical impedance spectroscopy and potential dynamic polarization tests were performed to obtain corrosion parameters. Scanning electrochemical microscopy (SECM) was used to analyze the local electrochemical activity of the surface film. Atomic force microscope (AFM), Scanning electron microscope-Energy dispersive spectrometer and Fourier transform infrared spectroscopy were used to determine the surface morphology and chemical composition of the surface film. Findings Experimental results showed the presence of BSA in a certain concentration range (0 to 2.0 g/L) has a greater inhibitory effect on the corrosion of AZ31, however, the presence of high-concentration BSA (5.0 g/L) would sharply reduce the corrosion resistance. Originality/value When the concentration of BSA is less than 2.0 g/L, the corrosion resistance of AZ31 enhances with the concentration. The adsorption BSA layer will come into being a physical barrier to inhibit the corrosion process. However, high-concentration BSA (5.0 g/L) will chelate with dissolved metal ions (such as Mg and Ni) to form soluble complexes, which increases the roughness of the surface and accelerates the corrosion process.


2014 ◽  
Vol 61 (5) ◽  
pp. 319-327 ◽  
Author(s):  
Mohamed Gobara ◽  
Mohamed Shamekh

Purpose – This paper aims to study both the mechanical properties and the corrosion behavior of the synthesized in situ (TiC-TiB2) particulates/AZ91 magnesium matrix composite and compare the results with that of the conventional AZ91D alloy. Design/methodology/approach – Scanning electron microscope (SEM) equipped with energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD) were used to study the surface morphology and crystalline structure. Mechanical compression tests were used to investigate the mechanical performance according to ASTM E9-89a. The corrosion behavior of the synthesized magnesium alloy was examined using both electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization techniques in dilute Harrison solutions. Findings – The microstructure of the Mg composite showed a uniform distribution of reinforcing phases. Also, the reinforcing phases were formed without residual intermediate phases. The addition of titanium and boron carbides not only enhanced the mechanical properties of the matrix but also improve its corrosion behavior. Originality/value – This is the first time that magnesium matrix composite has been to synthesized with TiC and TiB2 particulates starting from starting from Ti and B carbides powder without adding aluminium using practical and low-cost technique (in situ reactive infiltration technique). This paper studies the corrosion behavior of synthesized Mg matrix in dilute Harrison solution and compares the results with that of conventional AZ91D.


2018 ◽  
Vol 65 (6) ◽  
pp. 658-667 ◽  
Author(s):  
Yingjun Zhang ◽  
Baojie Dou ◽  
Yawei Shao ◽  
Xue-Jun Cui ◽  
Yanqiu Wang ◽  
...  

Purpose This paper aim to investigate the influence of PA on the corrosion behavior of carbon steel with blast cleaned or pre-rusted treatments, and interpret the inhibition mechanism of PA on the steel with different surface treatments. Design/methodology/approach The influence of PA on the corrosion behavior of blast cleaned or rusty steel was investigated by means of electrochemical impedance spectroscopy (EIS). The EIS data were analyzed using the @ZsimpWin commercial software. The morphology and component of steel after immersion were characterized by scanning electron microscopy (SEM), energy dispersive spectrometer (EDS), Fourier transformation infrared (FTIR) and X-ray diffractometer (XRD). Findings EIS analysis results indicated that PA had good corrosion inhibition for blast cleaned or rusty steel. SEM, EDS, FTIR and XRD further indicated that PA had two main corrosion inhibition processes for the corrosion inhibition of blast cleaned or rusty steel: corrosion dissolution and formation of protective barrier layers. Originality/value Most published works focus the attention only toward the effect of corrosion inhibitor for the clean metal surfaces. However, the surface condition of metal sometimes is unsatisfactory in the practical application of corrosion inhibitor, such as existing residual rust. Some studies also have shown that several corrosion inhibitors could be applied on partially rusted substrates. These inhibitors mainly include tannins and phosphoric acid, but not PA. Therefore, the authors investigated the influence of PA on the corrosion behavior of carbon steel with blast cleaned or pre-rusted treatments in this paper.


2019 ◽  
Vol 66 (6) ◽  
pp. 819-826
Author(s):  
Khashayar Tabi ◽  
Mansour Farzam ◽  
Davood Zaarei

Purpose Potassium silicate sealer was applied on solvent-cleaned, acid-pickled, dacromet-coated steel to improve its corrosion resistance. The purpose of this paper is to study the corrosion behavior of dacromet-coated steel. Design/methodology/approach Potassium silicate sealer was applied on solvent-cleaned, acid-pickled, dacromet-coated steel to improve its corrosion resistance. Electrochemical impedance spectroscopy (EIS), potentiodynamic polarization, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) and salt spray were carried out. SEM was used to study the morphological appearance of the surface. Findings The EIS behavior indicated that solvent-cleaned dacromet-coated steel sealed with potassium silicate showed that the corrosion current density was 2.664E − 5 A.cm2 which was reduced to 8.752E − 6 A.cm2 and the corrosion rate, which was 2.264E − 2 mm.year−1, was reduced to 7.438E − 3 mm.year−1 in NaCl 3.5 wt.per cent. EIS was used in NaCl 3.5 wt.%, and the Bode plot characteristics showed that the corrosion protection of solvent-cleaned, dacromet-coated steel was enhanced when sealed with potassium silicate. The EDS results of salt-sprayed, solvent-cleaned samples after 10 days indicated that the main corrosion products are composed of SiO2, ZnO and Al2O3. Research limitations/implications The detection of Li element in EDS was not possible because of the device limitation. Originality/value The current paper provides new information about the sealing properties of potassium silicate and its effects on the corrosion resistance of dacromet coating, which is widely used in many industries such as the automobile industry.


Metals ◽  
2020 ◽  
Vol 10 (6) ◽  
pp. 702
Author(s):  
F. Javier Gil ◽  
Eduardo Espinar-Escalona ◽  
Nuria Clusellas ◽  
Javier Fernandez-Bozal ◽  
Montserrat Artes-Ribas ◽  
...  

A potential new bactericide treatment for NiTi orthodontic archwires based in the electrodeposition of silver nanoparticles on the surface was studied. Twenty-five archwires were treated by electrodeposition, obtaining nanoparticles of silver embedded on the archwire surface. These were evaluated in order to investigate the possible changes on the superelastic characteristics (critical temperatures and stresses), the nickel ion release, and the bacteria culture behavior. The chemical composition was analyzed by Energy Dispersive X-Ray Spectroscopy-microanalysis; the singular temperatures of the martensitic transformation were obtained by a flow calorimeter. Induced martensitic transformation stresses were obtained by mechanical testing apparatus. Nickel ion release was analyzed by inductively coupled plasma-mass spectrometry (ICP-MS) equipment using artificial saliva solution at 37 °C. Bacterial tests were studied with the most used oral bacterial strains: Streptococcus sanguinis and Lactobacillus salivarius. NiTi samples were immersed in bacterial suspensions for 2 h at 37 °C. Adhered bacteria were separated and seeded on agar plates: Tood-Hewitt (TH) and Man-Rogosa-Sharpe (MRS) for S. sanguinis and for L.salivarius, respectively. These were then incubated at 37 °C for 1 day and the colonies were analyzed. The results showed that the transformation temperatures and the critical stresses have not statistically significant differences. Likewise, nickel ion release at different immersion times in saliva at 37 °C does not present changes between the original and treated with silver nanoparticles archwires. Bacteria culture results showed that the reduction of the bacteria due to the presence to the nanoparticles of silver is higher than 90%. Consequently, the new treatment with nanoparticles of silver could be a good candidate as bactericidic orthodontic archwire.


2011 ◽  
Vol 284-286 ◽  
pp. 1701-1704
Author(s):  
Jing Ling Ma ◽  
Jiu Ba Wen ◽  
Gao Lin Li

The corrosion behavior of Al-5Zn-0.03In and Al-5Zn-0.03Ga alloys in 3.5 % NaCl solution has been examined by electrochemical methods, scanning electron microscopy, X-ray microanalysis, electrochemical impedance spectroscopy. The results demonstrate that the alloys differ in the microstructure, corroded morphology and electrochemical properties. For Al-5Zn-0.03In alloy, the precipitates enriched in Al and Zn initiates pitting. For Al-5Zn-0.03Ga alloy, corrosion occurs more uniformly, the corrosion of the alloy occurred via the formation of a surface Ga-Al amalgam alloy. The EIS of Al-5Zn-0.03In alloy contains a capacitive loop and an inductive loop; the inductive loop can be attributed to the presence of the pitting. The EIS of Al-5Zn-0.03Ga alloy contains only a capacitive loop.


Sign in / Sign up

Export Citation Format

Share Document