Parametric study and performance improvement of regenerative flow pump considering the modification in blade and casing geometry

2017 ◽  
Vol 27 (8) ◽  
pp. 1887-1906 ◽  
Author(s):  
Jafar Nejad ◽  
Alireza Riasi ◽  
Ahmad Nourbakhsh

Purpose Regenerative flow pump (RFP) is a rotodynamic turbomachine capable of developing high pressure rise at low flow rates. This paper aims to numerically investigate the performance of a regenerative pump considering the modification in blade and casing geometry. Design/methodology/approach The radial blade shape was changed to the bucket form and a core is added to flow path. A parametric study was performed to improve the performance of the pump. Thus, the effect of change in blade angle, chord, height, pitch to chord ratio and also inlet port on the performance of RFP was investigated. Findings Results showed that the modified blade angle to achieve the maximum efficiency is about 41 degree. Also, the most efficient point occurs close to pitch/chord = 0.4 and by reducing the axial chord, efficiency of the pump increases. It was found that better efficiency will be achieved by increasing the “Arc of admission”, but there are limitations of manufacturing. It was observed that the performance curves shifted towards lower flow coefficients by reducing height of blades. Originality/value To improve the characteristics of regenerative pump, the blade shape changed to the bucket form (airfoil blades with identical inlet and outlet angle) and a core is added to flow path. A parametric study has been accomplished to see the influence of some important parameters on the performance of the pump.

2019 ◽  
Vol 29 (8) ◽  
pp. 2606-2621
Author(s):  
Jafar Nejadali

Purpose Regenerative flow pumps are dynamic machines with the ability to develop high heads at low flow rates. Simplicity, compactness, stable features and low manufacturing costs make them interesting for many applications in industries. The purpose of this study is to present a new method for calculating the flow through regenerative pumps with bucket form blades to predict the performance curves by a cheap and easy-to-use way. Design/methodology/approach The analysis was carried out based on the geometric shape of a fluid particle trajectory in a regenerative turbomachine. The fluid particle path was assumed to be a helix wrapped into a torus. Loss models were considered and the results of predictions were compared with computational fluid dynamics (CFD) data. Findings The overall trend of performance curves resulted from presented model looked consistent with CFD data. However, there were slight differences in high and low flow coefficients. The results showed that the predicted geometric shape of the flow path with the presented model (a helix wrapped into a torus) was not consistent with CFD results at high flow coefficients. Due to the complexity and turbulence of the fluid flow and errors in the calculation of losses, as well as slip factor, there was a discrepancy between the results of the presented model and numerical simulation, especially in high and low flow coefficients. Originality/value The analysis was carried out based on the geometric shape of a fluid particle trajectory in a regenerative turbomachine with bucket form blades. The fluid particle path was assumed to be a helix wrapped into a torus.


2016 ◽  
Vol 2016 ◽  
pp. 1-16 ◽  
Author(s):  
J. Nejadrajabali ◽  
A. Riasi ◽  
S. A. Nourbakhsh

Regenerative pump is a low specific speed and rotor-dynamic turbomachine capable of developing high heads at low flow rates. In this paper, a numerical study has been carried out in order to investigate the effect of blade angle on the performance of a regenerative pump. Two groups of impellers were employed. The first type has symmetric angle blades with identical inlet/outlet angles of ±10°, ±30°, and ±50° and the second group has nonsymmetric angle blades in which the inlet angle was set to 0° and six different angles of ±10°, ±30°, and ±50° were designed for the outlet of the blades. A total of 12 impellers, as well as primary radial blades impeller, were investigated in this study. The results showed that all forward blades have higher head coefficients than radial blades impeller at design flow coefficient. It was found that regenerative pumps with symmetric angle forward blades have better performance than other types. Also, it is worth mentioning that the highest head coefficient and efficiency occur at angle+10<β<+30of symmetric angle blades. It was found that the maximum efficiency occurs at angle of +15.5° by curve fitting to the data obtained from numerical simulations for symmetric angle forward blades.


2021 ◽  
Author(s):  
Nur Alom ◽  
Bikash Kumar Sarkar

Abstract Cross-flow hydro turbines (CFHTs) are generally used in micro hydraulic power plants due to their simplicity in design and fabrication, moderate efficiency, ease of maintenance. The CFHT can be used in low flow and low head conditions with an efficiency of around 90% at rated conditions. However, the efficiency of the CFHT can further be improved by changing its geometric parameters Hence, in the present investigation, 3D unsteady simulations are performed in order to locate the exit blade angle (β2) with the intention is to improve the efficiency of the turbine. In the proposed investigation, the multi-physics FVM solver ANSYS Fluent has been used with the help of the SST k-ω turbulence model to carry out the unsteady simulations. The 3D unsteady simulations are performed by varying the exit blade angle (β2) from 60° to 90° to improve its efficiency when the rotational speed is fixed with the number of blades being 20. From the unsteady simulations, the maximum efficiency of the CFHT is at the exit blade angle (β2) = 80°.


2011 ◽  
Vol 354-355 ◽  
pp. 669-673
Author(s):  
Xian Fang Wu ◽  
Hou Lin Liu ◽  
Ming Gao Tan ◽  
Hong Hui Li

The characteristics and research actuality on mixed flow pumps are introduced simplely. A mixed flow pump with volute as diffusion part is designed and its specific speed is 556.8. The axial velocity circulation and blade angle variety with linearity distribution are used to deisign the impeller. The fixed diffeuser between impeller and volute is deigned by arc airfoil.The cross sections of volute are all asymmetry. The commercial code FLUENT is applied to simulate the inner flow in the mixed flow pump and its energy characteristics are predicted according to the simulation results. The inner flow analysis indicates that the flow in the pump is good and the characteristic prediction shows that the pump performance can meet the design demand. The experiment test of the pump are done. When the blade angle is about 0°, the maximum efficiency of the pump is up to 85.76% and the actual efficiency at design point is about 3% higher than demand efficiency. The study fruits can instruct the hydraulic design of higher specific speed mixed flow pump with volute as diffusion part.


2016 ◽  
Vol 2016 ◽  
pp. 1-13 ◽  
Author(s):  
Martin Heinrich ◽  
Rüdiger Schwarze

A numerical model for the genetic optimization of the volute of a centrifugal compressor for light commercial vehicles is presented. The volute cross-sectional shape is represented by cubic B-splines and its control points are used as design variables. The goal of the global optimization is to maximize the average compressor isentropic efficiency and total pressure ratio at design speed and four operating points. The numerical model consists of a density-based solver in combination with the SSTk-ωturbulence model with rotation/curvature correction and the multiple reference frame approach. The initial validation shows a good agreement between the numerical model and test bench measurements. As a result of the optimization, the average total pressure rise and efficiency are increased by over1.0%compared to the initial designs of the optimization, while the maximum efficiency rise is nearly 2.5% atm˙corr=0.19 kg/s.


Author(s):  
Yo Han Jung ◽  
Young Uk Min ◽  
Jin Young Kim

This paper presents a numerical investigation of the effect of tip clearance on the suction performance and flow characteristics at different flow rates in a vertical mixed-flow pump. Numerical analyses were carried out by solving three-dimensional Reynolds-averaged Navier-Stokes equations. Steady computations were performed for three different tip clearances under noncavitating and cavitating conditions at design and off-design conditions. The pump performance test was performed for the mixed-flow pump and numerical results were validated by comparing the experimental data for a system characterized by the original tip clearance. It was shown that for large tip clearance, the head breakdown occurred earlier at the design and high flow rates. However, the head breakdown was quite delayed at low flow rate. This resulted from the cavitation structure caused by the tip leakage flow at different flow rates.


2000 ◽  
Vol 93 (5) ◽  
pp. 808-814 ◽  
Author(s):  
Mette K. Schulz ◽  
Lars Peter Wang ◽  
Mogens Tange ◽  
Per Bjerre

Object. The success of treatment for delayed cerebral ischemia is time dependent, and neuronal monitoring methods that can detect early subclinical levels of cerebral ischemia may improve overall treatment results. Cerebral microdialysis may represent such a method. The authors' goal was to characterize patterns of markers of energy metabolism (glucose, pyruvate, and lactate) and neuronal injury (glutamate and glycerol) in patients with subarachnoid hemorrhage (SAH), in whom ischemia was or was not suspected.Methods. By using low-flow intracerebral microdialysis monitoring, central nervous system extracellular fluid concentrations of glucose, pyruvate, lactate, glutamate, and glycerol were determined in 46 patients suffering from poor-grade SAH. The results in two subgroups were analyzed: those patients with no clinical or radiological signs of cerebral ischemia (14 patients) and those who succumbed to brain death (five patients).Significantly lower levels of energy substrates and significantly higher levels of lactate and neuronal injury markers were observed in patients with severe and complete ischemia when compared with patients without symptoms of ischemia (glucose 0 compared with 2.12 ± 0.15 mmol/L; pyruvate 0 compared with 151 ± 11.5 µmol; lactate 6.57 ± 1.07 compared with 3.06 ± 0.32 mmol/L; glycerol 639 ± 91 compared with 81.6 ± 12.4 µmol; and glutamate 339 ± 53.4 compared with 14 ± 3.33 µmol). Immediately after catheter placement, glutamate concentrations declined over the first 4 to 6 hours to reach stable values. The remaining parameters exhibited stable values after 1 to 2 hours.Conclusions. The results confirm that intracerebral microdialysis monitoring of patients with SAH can be used to detect patterns of cerebral ischemia. The wide range from normal to severe ischemic values calls for additional studies to characterize further incomplete and possible subclinical levels of ischemia.


Author(s):  
Quentin Dejour ◽  
Huu Duc Vo

This paper presents the first assessment of a new non-axial counter-rotating compressor concept. This concept consists of replacing the stator of a mixed-flow compressor stage or the diffuser of a centrifugal compressor stage with a counter-rotating rotor that will turn the flow back to the axial direction with much lower diffusion factor, while providing the equivalent in work of the upstream mixed-flow rotor or impeller. This concept has two advantages. First, the very high stage pressure rise means that only a single counter-rotating rotor may be required, making mechanical implementation simpler than for multi-stage axial counter-rotating compressors. Second, the replacement of the high flow turning (high loss) stator/diffuser in a non-axial stage with a low flow turning counter-rotating rotor gives the new concept potential for achieving higher efficiency than conventional non-axial compressors. As a first proof of concept, a subsonic counter-rotating mixed-flow compressor and its conventional (i.e. rotor-stator) equivalent have been designed with the intent of being implemented in a test rig. CFD simulations have been carried out for a comparative evaluation of both configurations. Results show that the counter-rotating mixed-flow compressor produces more than double the pressure rise of its conventional version with a slightly higher peak-efficiency while having a smaller axial length. Moreover, the counter-rotating configuration has a better stall margin than its conventional counterpart, for which the boundary layer separation from excessive flow turning in the stator causes early stall.


2017 ◽  
Vol 14 (1) ◽  
pp. 7-18 ◽  
Author(s):  
Ajaz Ahmad Dar ◽  
K. Elangovan

Purpose This paper aims to intend for investigating the influence of an inclined magnetic field on the peristaltic flow of a couple stress fluid through an inclined channel with heat and mass transfer. Design/methodology/approach Long wavelength and low Reynolds number methodology is actualized for simplifying the highly nonlinear equations. Mathematical expressions of axial velocity, pressure gradient and volume flow rate are obtained. Pressure rise, frictional force and pumping phenomenon are portrayed and symbolized graphically. Exact and numerical solutions have been carried out. The computed results are presented graphically for various embedded parameters. Temperature and concentration profile are also scrutinized and sketched. Findings Results from the current study concluded that the fluid motion can be enhanced by increasing the inclination of both the magnetic field and the channel. Originality/value The elemental characteristics of this analysis is a complete interpretation of the influence of couple stress parameter and inclination of magnetic field on the velocity, pressure gradient, pressure rise and frictional forces.