ANALYSIS OF THERMAL EFFICIENCY OF OPEN CYCLE GAS TURBINE POWER PLANT AT PUTRAJAYA (MALAYSIA)

2015 ◽  
Vol 76 (5) ◽  
Author(s):  
Alhassan Salami Tijani ◽  
Mohd Rashid Halim

The purpose of this paper is to study the performance of an existing open cycle gas turbine power plant at Putrajaya power station. At compressor inlet temperature of 298.90K, thermal efficiency of 31 % was observed for the existing or current cycle whiles the modified configuration yielded thermal efficiency of 45 %, this result in 14 % increase in thermal efficiency. At pressure ratio of 3.67, thermal efficiency of about 31.06% and 44% was recorded for the current cycle and regenerative cycle respectively. The efficiency of both cycles increase considerably with increase in pressure ratio, but at pressure ratio of about 7, only a small increase in efficiency for both cycles was observed. The optimum value of the efficiencies for both cycles that correspond to pressure ratio of 7 is 43.06 and 56% for the current cycle and the regenerative cycle respectively.

2011 ◽  
Vol 189-193 ◽  
pp. 3007-3013 ◽  
Author(s):  
M.M. Rahman ◽  
Thamir K. Ibrahim ◽  
K. Kadirgama ◽  
R. Mamat ◽  
Rosli A. Bakar

This paper presents the effect of ambient temperature and operation conditions (compression ratio, turbine inlet temperature, air to fuel ratio and efficiency of compressor and turbine) on the performance of gas turbine power plant. The computational model was developed utilizing the MATLAB codes. Turbine work found to be decreases as ambient temperature increases as well as the thermal efficiency decreases. It can be seen that the thermal efficiency increases linearly with increases of compression ratio while decreases of ambient temperature. The specific fuel consumption increases with increases of ambient temperature and lower turbine inlet temperature. The effect of variation of SFC is more significance at higher ambient temperature than lower temperature. It is observed that the thermal efficiency linearly increases at lower compressor ratio as well as higher turbine inlet temperature until certain value of compression ratio. The variation of thermal efficiency is more significance at higher compression ratio and lower turbine inlet temperature. Even though at lower turbine inlet temperature is decrement the thermal efficiency dramatically and the SFC decreases linearly with increases of compression ratio and turbine inlet temperature at lower range until certain value then increases dramatically for lower turbine inlet temperature.


2016 ◽  
Vol 5 (2) ◽  
pp. 25-44
Author(s):  
Saria Abed ◽  
Taher Khir ◽  
Ammar Ben Brahim

In this paper, thermodynamic study of simple and regenerative gas turbine cycles is exhibited. Firstly, thermodynamic models for both cycles are defined; thermal efficiencies of both cycles are determined, the overall heat transfer coefficient through the heat exchanger is calculated in order to determinate its performances and parametric study is carried out to investigate the effects of compressor inlet temperature, turbine inlet temperature and compressor pressure ratio on the parameters that measure cycles' performance. Subsequently, numerical optimization is established through EES software to determinate operating conditions. The results of parametric study have shown a significant impact of operating parameters on the performance of the cycle. According to this study, the regeneration technique improves the thermal efficiency by 10%. The studied regenerator has an important effectiveness (˜ 82%) which improves the heat transfer exchange; also a high compressor pressure ratio and an important combustion temperature can increase thermal efficiency.


2018 ◽  
Vol 220 ◽  
pp. 03011
Author(s):  
T. Aurthur Vimalachandran ◽  
Andrey Yurievich Tkachenko ◽  
Viktor Nikolaevich Rybakov

A detailed parametric analysis was performed on entire performance cycle model of micro gas turbine power plant. The parametric analysis was studied using Russian Software named ASTRA. Evaluation of parameters on both design and operation condition was performed. The parameters focused here are power output, compression work, specific fuel consumption and thermal efficiency. Various stages such as use of Intercooler, Pre-heater and their optimal influence on thermodynamics were performed. The task was to optimize the maximum output in free turbine power by simulating various cycles of compressor pressure ratios for centrifugal compressor, ambient temperature in various altitude; air-fuel mix ratio and turbine inlet temperature. The results are analysed and presented in this article, the Analysis known as on-design analysis. The compressor uses 66% of turbine work output. The research analysis focuses on reducing the use of power output by compressor and maximizes the power output by free turbine. The results could be summarized as increase in gas turbine thermal efficiency does not always improve the gas turbine efficiency. Optimum power increase of up to 3% was improved and improvement in fuel efficiency improved about 4%.


Processes ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. 705
Author(s):  
Thodsaphon Jansaengsuk ◽  
Mongkol Kaewbumrung ◽  
Wutthikrai Busayaporn ◽  
Jatuporn Thongsri

To solve the housing damage problem of a fractured compressor blade (CB) caused by an impact on the inner casing of a gas turbine in the seventh stage (from 15 stages), modifications of the trailing edge (TE) of the CB have been proposed, namely 6.5 mm curved cutting and a combination of 4 mm straight cutting with 6.5 mm curved cutting. The simulation results of the modifications in both aerodynamics variables Cl and Cd and the pressure ratio, including structural dynamics such as a normalized power spectrum, frequency, total deformation, equivalent stress, and the safety factor, found that 6.5 mm curved cutting could deliver the aerodynamics and structural dynamics similar to the original CB. This result also overcomes the previous work that proposed 5.0 mm straight cutting. This work also indicates that the operation of a CB gives uneven pressure and temperature, which get higher in the TE area. The slightly modified CB can present the difference in the properties of both the aerodynamics and the structural dynamics. Therefore, any modifications of the TE should be investigated for both properties simultaneously. Finally, the results from this work can be very useful information for the modification of the CB in the housing damage problem of the other rotating types of machinery in a gas turbine power plant.


Author(s):  
James Spelling ◽  
Björn Laumert ◽  
Torsten Fransson

A dynamic simulation model of a hybrid solar gas-turbine power plant has been developed, allowing determination of its thermodynamic and economic performance. In order to examine optimum gas-turbine designs for hybrid solar power plants, multi-objective thermoeconomic analysis has been performed, with two conflicting objectives: minimum levelized electricity costs and minimum specific CO2 emissions. Optimum cycle conditions: pressure-ratio, receiver temperature, turbine inlet temperature and flow rate, have been identified for a 15 MWe gas-turbine under different degrees of solarization. At moderate solar shares, the hybrid solar gas-turbine concept was shown to provide significant water and CO2 savings with only a minor increase in the levelized electricity cost.


Author(s):  
Saeed Farokhi

In a modern gas turbine power plant, the axial exhaust diffuser accounts for up to 10% of the generator power. An unshrouded rotor, due to its highly energetic tip clearance flow, improves the pressure recovery characteristic of the exhaust diffuser, while the power production within the blading suffers a loss as a result of the tip leakage flow. In this paper, these conflicting trends are thermodynamically investigated and nondimensional expressions are derived which facilitate the task of a gas turbine system designer. Conservatively, 1% thermal efficiency gain results from elimination of the last rotor tip clearance flow. The corresponding increase in thermal efficiency of a modern gas turbine power plant due to enhanced diffuser pressure recovery is less than one percent.


2020 ◽  
Author(s):  
J. Fajardo ◽  
D. Barreto ◽  
T. Castro ◽  
I. Baldiris

Abstract It is known that high temperatures adversely affect the performance of gas turbines, but the effect of the combination of atmospheric conditions (temperature and relative humidity -RH-) on the operation of this type of system is unknown. In this work the effects of atmospheric conditions on the energy and exergy indicators of a power plant with gas turbine were studied. The indicators studied were the mass flow, the specific work consumed by the compressor, specific work produced by the turbine, the combustion gas temperature, the NO concentration, the net output power, the thermal efficiency, the heat rate, the specific consumption of fuel, the destruction of exergy and exergy efficiency. Among the results, it is noted that for each degree celsius that reduces the temperature of the air at the compressor inlet at constant relative humidity on average, the mass flow of dry air increases by 0.27 kg/s, the specific work consumed by the compressors decreases by 0.45%, the output power increases by 1.17% and the thermal efficiency increases by 0.8%, the exergy destruction increases by 0.72% and the exergy efficiency increases by 0.81%. In addition, humidity changes relative to high temperatures are detected more significantly than at low temperatures. The power plant studied is installed in Cartagena, Colombia and since it is not operating in the design environmental conditions (15 °C and 60% relative humidity) it experiences a loss of output power of 6140 kW and a drop in thermal efficiency of 5.12 %. These results allow considering the implementation of air cooling technologies at the compressor inlet to compensate for the loss of power at atmospheric air conditions.


Author(s):  
Anoop Kumar Shukla ◽  
Onkar Singh

Gas/steam combined cycle power plants are extensively used for power generation across the world. Today’s power plant operators are persistently requesting enhancement in performance. As a result, the rigour of thermodynamic design and optimization has grown tremendously. To enhance the gas turbine thermal efficiency and specific power output, the research and development work has centered on improving firing temperature, cycle pressure ratio, adopting improved component design, cooling and combustion technologies, and advanced materials and employing integrated system (e.g. combined cycles, intercooling, recuperation, reheat, chemical recuperation). In this paper a study is conducted for combining three systems namely inlet fogging, steam injection in combustor, and film cooling of gas turbine blade for performance enhancement of gas/steam combined cycle power plant. The evaluation of the integrated effect of inlet fogging, steam injection and film cooling on the gas turbine cycle performance is undertaken here. Study involves thermodynamic modeling of gas/steam combined cycle system based on the first law of thermodynamics. The results obtained based on modeling have been presented and analyzed through graphical depiction of variations in efficiency, specific work output, cycle pressure ratio, inlet air temperature & density variation, turbine inlet temperature, specific fuel consumption etc.


Author(s):  
Hideto Moritsuka

In order to estimate the possibility to improve thermal efficiency of power generation use gas turbine combined cycle power generation system, benefits of employing the advanced gas turbine technologies proposed here have been made clear based on the recently developed 1500C-class steam cooling gas turbine and 1300C-class reheat cycle gas turbine combined cycle power generation systems. In addition, methane reforming cooling method and NO reducing catalytic reheater are proposed. Based on these findings, the Maximized efficiency Optimized Reheat cycle Innovative Gas Turbine Combined cycle (MORITC) Power Generation System with the most effective combination of advanced technologies and the new devices have been proposed. In case of the proposed reheat cycle gas turbine with pressure ratio being 55, the high pressure turbine inlet temperature being 1700C, the low pressure turbine inlet temperature being 800C, combined with the ultra super critical pressure, double reheat type heat recovery Rankine cycle, the thermal efficiency of combined cycle are expected approximately 66.7% (LHV, generator end).