scholarly journals Experimental Assessment of Energy Performance and Emissions of a Residential Microcogenerator

2014 ◽  
Vol 1 (2) ◽  
pp. 48 ◽  
Author(s):  
Giovanni Angrisani ◽  
Carlo Roselli ◽  
Maurizio Sasso ◽  
Peter Tzscheutschler

Microcogeneration can guarantee sensible primary energy savings and greenhouse gas emissions reductions in the residential sector. In this paper, the results of experimental tests carried out on a microcogenerator (5.5 kW electric power and 14.8 kW thermal power) based on a natural gas fuelled internal combustion engine, integrated with a condensing boiler, have been analyzed. Tests have been performed out at Institute for Energy Economy and Application Technology (IfE) of Technical University of Munich (Germany). The test facility allowed to simulate the thermal energy requirements of a real residential application, represented by a Multi Family House consisting of 10 apartments, and to evaluate the energy flows of the conversion devices in actual operating conditions. Four type days, characteristic of Mediterranean climatic conditions, have been used to define space heating and domestic hot water user’s requirements. Experimental tests have been performed to implement energy and environmental analysis, comparing the system consisting of cogenerator and integration boiler with a reference system. Results showed that the former can achieve a primary energy saving of about 6%, and CO2 equivalent emissions reduction of about 12%. Finally, the algorithm defined by the European Directive on the promotion of high efficiency cogeneration has been implemented; it demonstrated that the primary energy saving is well above the limit value prescribed by the Directive. Therefore the cogeneration plant can access support mechanisms that can help to achieve the economic feasibility of the system, besides energy and environmental benefits.

2021 ◽  
Vol 9 (1) ◽  
pp. 6
Author(s):  
Diego Fernández-Cheliz ◽  
Eloy Velasco-Gómez ◽  
Juan Peral-Andrés ◽  
Ana Tejero-González

In Europe, primary energy consumption in buildings accounts for up to 25–40%, depending on the climate conditions. Space heating and Domestic Hot Water (DHW) contribute significantly to this energy consumption. Among the most common sources for heat generation in these appliances is natural gas. Condensing boilers can surpass the 100% energy performance over the lower heating value, if the operating conditions enable the water vapor in the exhaust gases to condensate. Consequently, optimizing the operating parameters of condensing boilers is necessary to decrease fuel consumption without hindering water heating needs. The present work presents an experimental approach to the operating parameters of a condensing boiler that works with natural gas. The aim is to develop a theoretical model that relates the energy performance to the water temperature set by the final user and the excess air set by the maintenance staff.


Machines ◽  
2019 ◽  
Vol 7 (1) ◽  
pp. 4 ◽  
Author(s):  
Luqman S. Maraaba ◽  
Zakariya M. Al-Hamouz ◽  
Abdulaziz S. Milhem ◽  
Ssennoga Twaha

The application of line-start permanent magnet synchronous motors (LSPMSMs) is rapidly spreading due to their advantages of high efficiency, high operational power factor, being self-starting, rendering them as highly needed in many applications in recent years. Although there have been standard methods for the identification of parameters of synchronous and induction machines, most of them do not apply to LSPMSMs. This paper presents a study and analysis of different parameter identification methods for interior mount LSPMSM. Experimental tests have been performed in the laboratory on a 1-hp interior mount LSPMSM. The measurements have been validated by investigating the performance of the machine under different operating conditions using a developed qd0 mathematical model and an experimental setup. The dynamic and steady-state performance analyses have been performed using the determined parameters. It is found that the experimental results are close to the mathematical model results, confirming the accuracy of the studied test methods. Therefore, the output of this study will help in selecting the proper test method for LSPMSM.


Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 1200
Author(s):  
Yong-Joon Jun ◽  
Seung-ho Ahn ◽  
Kyung-Soon Park

The Green Remodeling Project under South Korea’s Green New Deal policy is a government-led project intended to strengthen the performance sector directly correlated with energy performance among various elements of improvement applicable to building remodeling by replacing insulation materials, introducing new and renewable energy, introducing high-efficiency equipment, etc., with public buildings taking the lead in green remodeling in order to induce energy efficiency enhancement in private buildings. However, there is an ongoing policy that involves the application of a fragmentary value judgment criterion, i.e., whether to apply technical elements confined to the enhancement of the energy performance of target buildings and the prediction of improvement effects according thereto, thus resulting in the phenomenon of another important value criterion for green remodeling, i.e., the enhancement of the occupant (user) comfort performance of target buildings as one of its purposes, being neglected instead. In order to accurately grasp the current status of these problems and to promote ‘expansion of the value judgment criteria for green remodeling’ as an alternative, this study collected energy usage data of buildings actually used by public institutions and then conducted a total analysis. After that, the characteristics of energy usage were analyzed for each of the groups of buildings classified by year of completion, thereby carrying out an analysis of the correlation between the non-architectural elements affecting the actual energy usage and the actual energy usage data. The correlation between the improvement performance of each technical element and the actual improvement effect was also analyzed, thereby ascertaining the relationship between the direction of major policy strategies and the actual energy usage. As a result of the relationship analysis, it was confirmed that the actual energy usage is more affected by the operating conditions of the relevant building than the application of individual strategic elements such as the performance of the envelope insulation and the performance of the high-efficiency system. In addition, it was also confirmed that the usage of public buildings does not increase in proportion to their aging. The primary goal of reducing energy usage in target buildings can be achieved if public sector (government)-led green remodeling is pushed ahead with in accordance with biased value judgment criteria, just as in the case of a campaign to refrain from operating cooling facilities in aging public buildings. However, it was possible to grasp through the progress of this study that the remodeling may also result in the deterioration of environmental comfort and stability, such as the numerical value of the indoor thermal environment. The results of this study have the significance of providing basic data for pushing ahead with a green remodeling policy in which the value judgment criteria for aging existing public buildings are more expanded, and it is necessary to continue research in such a direction that the quantitative purpose of green remodeling, which is to reduce energy usage in aging public buildings, and its qualitative purpose, which is to enhance their environmental performance for occupants’ comfort, can be mutually balanced and secured at the same time.


2006 ◽  
Vol 129 (2) ◽  
pp. 226-234
Author(s):  
Robert Hendron ◽  
Mark Eastment ◽  
Ed Hancock ◽  
Greg Barker ◽  
Paul Reeves

Building America (BA) partner McStain Neighborhoods built the Discovery House in Loveland, CO, with an extensive package of energy-efficient features, including a high-performance envelope, efficient mechanical systems, a solar water heater integrated with the space-heating system, a heat-recovery ventilator (HRV), and ENERGY STAR appliances. The National Renewable Energy Laboratory (NREL) and Building Science Consortium conducted short-term field-testing and building energy simulations to evaluate the performance of the house. These evaluations are utilized by BA to improve future prototype designs and to identify critical research needs. The Discovery House building envelope and ducts were very tight under normal operating conditions. The HRV provided fresh air at a rate of about 35L∕s(75cfm), consistent with the recommendations of ASHRAE Standard 62.2. The solar hot water system is expected to meet the bulk of the domestic hot water (DHW) load (>83%), but only about 12% of the space-heating load. DOE-2.2 simulations predict whole-house source energy savings of 54% compared to the BA Benchmark (Hendron, R., 2005 NREL Report No. 37529, NREL, Golden, CO). The largest contributors to energy savings beyond McStain’s standard practice are the solar water heater, HRV, improved air distribution, high-efficiency boiler, and compact fluorescent lighting package.


Author(s):  
Robert Hendron ◽  
Mark Eastment ◽  
Ed Hancock ◽  
Greg Barker ◽  
Paul Reeves

Building America (BA) partner McStain Neighborhoods built the Discovery House in Loveland, Colorado, with an extensive package of energy-efficient features, including a high-performance envelope, efficient mechanical systems, a solar water heater integrated with the space-heating system, a heat-recovery ventilator (HRV), and ENERGY STAR™ appliances. The National Renewable Energy Laboratory (NREL) and Building Science Consortium (BSC) conducted short-term field-testing and building energy simulations to evaluate the performance of the house. These evaluations are utilized by BA to improve future prototype designs and to identify critical research needs. The Discovery House building envelope and ducts were very tight under normal operating conditions. The HRV provided fresh air at a rate of about 75 cfm (35 l/s), consistent with the recommendations of ASHRAE Standard 62.2. The solar hot water system is expected to meet the bulk of the domestic hot water (DHW) load (>83%), but only about 12% of the space-heating load. DOE-2.2 simulations predict whole-house source energy savings of 54% compared to the BA Benchmark [1]. The largest contributors to energy savings beyond McStain’s standard practice are the solar water heater, HRV, improved air distribution, high-efficiency boiler, and compact fluorescent lighting package.


2016 ◽  
Vol 861 ◽  
pp. 198-205
Author(s):  
Anton Pitonak ◽  
Martin Lopusniak

In the members states of the European Union, portion of buildings in the total consumption of energy represents 40%, and their portion in CO2 emissions fluctuates around 35%. The European Union is trying to protect the environment by reducing energy demand and releasing CO2 emissions into the air. Energy performance is the quantity of energy, which is necessary for heating and domestic hot water production, for cooling and ventilation and for lighting. Based on results of energy performance, individual buildings are classified into energy classes A to G. A global indicator (primary energy) is the decisive factor for final evaluation of the building. The new building must meet minimum requirements for energy performance, i.e. it must be classified to energy class A1 since 2016, and to energy class A0 since 2020. The paper analyses effect of the use of different resources of heat in a family house designed according to requirements valid since 2020, and its subsequent classification into an energy class.


Author(s):  
Maurizio Sasso ◽  
Raffaello Possidente ◽  
Carlo Roselli ◽  
Sibilio Sergio

The cogeneration, or the combined production of electric (and/or mechanical) and thermal energy, is a well established technology, which has important environmental benefits and it has been noted by the European Community as one of the first elements to save primary energy, to avoid network losses and to reduce the greenhouse gas emissions. In particular, the study will be focused on the micro-cogeneration process with micro-combined heat and power system, or MCHP (electric power output ≤ 15 kW), which represents a valid and interesting application of this technology applicable, above all, to residential and light commercial users. This paper presents the Energy, Economic and Environmental (3-E) analysis of a natural gas-fired MCHP in combination with an electric heat pump (EHP). The 3-E analysis of the MCHP/EHP begins with the results of a detailed experimental activity developed in a test facility [1] for a wide range of conditions. Two operating conditions were simulated: a heating mode with co-production of electric and thermal energy, and a cooling mode with co-production of electric, thermal and cooling energy (tri-generation). The annual operating performance, also based on the typical features of the Italian market, is also discussed with a simplified approach.


Author(s):  
Yoriharu Murata ◽  
Naoki Shibukawa ◽  
Itaru Murakami ◽  
Joji Kaneko ◽  
Kenichi Okuno

The titanium 48-inch last stage blade that has world’s largest class exhaust annulus area and tip speed for 60Hz steam turbines has been developed. Concept of this blade is to achieve high performance and compact design of steam turbine for 1000MW thermal power plant and 300MW combined cycle plant. In the design of this blade, the optimization design has been done by using the recent analysis technologies, three dimensional CFD in aerodynamic design and FEA in mechanical design. The blade has curved axial fir-tree dovetail, snubber cover both at the tip and at the mid-span. To achieve superior vibration characteristics, continuously coupled structure was adopted for blade connection. To confirm the validity of design, first, sub-scale model blades were provided and tested in model steam turbine test facilities. Second, one row of actual size blades were assembled on the wheel of test rotor and were exposed rotating vibration test in a wheel box. Finally, these blades were tested at actual steam conditions in a full scale steam turbine test facility. In this paper, aerodynamic and mechanical design features will be introduced, and the test results of both sub-scale and actual size blades under real steam turbine operating conditions will be presented.


Author(s):  
E. A. Boiko ◽  
I. V. Zagorodnii

THE PURPOSE. Comprehensive research of the slagging intensity is the heating surfaces of the BKZ-420-140 boiler unit with solid slag removal at the Abakan CHP when burning non-project fuels. The relevance of the work is due to the technical necessity and economic feasibility of conversion boiler units to combustion of non-design coals. METHODS. The problem has been analyzed by methodology for conducting complex tests, measurements and processing of experimental data, as well as the results of experimental and computational studies of a boiler unit when operating on coals of various qualities. RESULTS. Qualitative and quantitative parameters for assessing the properties of off-design coals and their behavior in real operating conditions of radiation, semi-radiation and convective conditions, taking into account their modes and design functions, have been obtained. CONCLUSION: A computational analysis of the operating modes of boiler units when burning non-design fuels showed that a promising technology for involving non-design coals in the fuel and energy balance of a thermal power plant is providing a scientifically based mixture of design and nondesign fuels.Analysis of the slagging and polluting properties of non-design coals makes it possible to predict changes in the characteristics of the thermal efficiency of heating surfaces and to develop many practical recommendations for optimizing the parameters of the cleaning equipment installed on the boiler.Also, mixtures of fuels were determined for which the wall temperatures of the metal of the outlet stack of the superheater increase, which significantly reduces the strength characteristics of the surface.The assessment and prediction of the reliability of the heating surface is carried out by calculating the temperature of the metal wall in the most heat-stressed place.


1979 ◽  
Author(s):  
Z. P. Tilliette ◽  
B. Pierre

A particular arrangement applicable to open or closed recuperative gas cycles, consisting of a heat generator partly by-passing the low pressure side of the recuperator, is proven to enhance the advantages of gas cycles for energy production. In this way, the cogeneration of both power with high efficiency owing to the recuperator and high temperature process heat becomes possible and economically attractive. Furthermore, additional possibilities appear for power generation by combined gas and steam or ammonia cycles. In any case, the overall utilitization coefficient of the primary energy is increased and the combined production of low or medium temperature heat can also be improved. The great operation flexibility of the system for combined energy generation is worth being emphasized: the by-pass arrangement involves no significant change in the operating conditions of the main turbocompressor as the heat output varies. Applications of this arrangement are made to open and closed gas cycle power plants using fossil, nuclear and solar energies. The overall heat conversion efficiency is tentatively estimated in order to appreciate the energy conversion capability of the investigated power plants.


Sign in / Sign up

Export Citation Format

Share Document