Computational Modeling and Simulation of a Single-Jet Water Meter

2008 ◽  
Vol 130 (5) ◽  
Author(s):  
Gorka S. Larraona ◽  
Alejandro Rivas ◽  
Juan Carlos Ramos

A single-jet water meter was modeled and simulated within a wide measuring range that included flow rates in laminar, transitional, and turbulent flow regimes. The interaction between the turbine and the flow, on which the operating principle of this kind of meter is based, was studied in depth from the detailed information provided by simulations of the three dimensional flow within the meter. This interaction was resolved by means of a devised semi-implicit time-marching procedure in such a way that the speed and the position of the turbine were obtained as part of the solution. Results obtained regarding the turbine’s mean rotation speed, measurement error, and pressure drop were validated through experimental measurements performed on a test rig. The role of mechanical friction on the performance of the meter at low flow rates was analyzed and interesting conclusions about its influence on the reduction of the turbine’s rotation speed and on the related change in the measurement error were drawn. The mathematical model developed was capable of reproducing the performance of the meter throughout the majority of the measuring range, and thus was shown to be a very valuable tool for the analysis and improvement of the single-jet water meter studied.

Author(s):  
Carmen Virginia Palau ◽  
Juan Manzano ◽  
Iban Balbastre Peralta ◽  
Benito Moreira de Azevedo ◽  
Guilherme Vieira do Bomfim

To maintain quality measurement of water consumption, it is necessary to know the metrology of single-jet water meters over time. Knowing the accuracy of these instruments over time allows establishing a metrological operation period for different flow rates. This will aid water companies to optimize management and reduce economic losses due to unaccounted water consumption. This study analyzed the influence of time on the measurement error of single-jet water meters to evaluate the deterioration of the equipment and, with that, launch the metrological operation period. According to standards 8316 and 4064 of the International Organization for Standardization (ISO), 808 meters of metrological Class B were evaluated in six water supplies, with age ranges of 3.7 to 16.4 years of use. The measurement error was estimated by comparing the volume measured in a calibrated tank with the volume registered by the meters at flow rates of 30, 120, 750 and 1,500 L h-1. The metrological operation period of the meters was obtained for each flow rate by the relation between error of measurement and time of use (simple linear regression). According to the results, the majority of the equipment presents increasing under-registration errors over time, more pronounced at low flow rates and with less favorable operating conditions. The metrological operation period for flow rates of 30, 120, 750 and 1,500 L h-1 is estimated at approximately 3, 8, 14 and 13 years. This operation period combined with consumption patterns of users will establish the best time to replace the meters.


2019 ◽  
Vol 21 (27) ◽  
pp. 14605-14611 ◽  
Author(s):  
R. Moosavi ◽  
A. Kumar ◽  
A. De Wit ◽  
M. Schröter

At low flow rates, the precipitate forming at the miscible interface between two reactive solutions guides the evolution of the flow field.


Author(s):  
Michael B. Wilkinson ◽  
Francois G. Louw ◽  
Sybrand J. van der Spuy ◽  
Theodor W. von Backström

The performance of large mechanical draft air-cooled heat exchangers is directly related to fan performance which is influenced by atmospheric wind conditions, as well as the plant layout. It is often necessary to numerically model the entire system, including fans, under a variety of operating conditions. Full three-dimensional, numerical models of axial flow fans are computationally expensive to solve. Simplified models that accurately predict fan performance at a lesser expense are therefore required. One such simplified model is the actuator disk model (ADM). This model approximates the fan as a disk where the forces generated by the blades are calculated and translated into momentum sources. This model has been proven to give good results near and above the design flow rate of a fan, but not at low flow rates. In order to address this problem two modifications were proposed, namely the extended actuator disk model (EADM) and the reverse engineered empirical actuator disk model (REEADM). The three models are presented and evaluated in this paper using ANSYS FLUENT. The models are simulated at different flow rates representing an axial flow fan test facility. The resulting performance results and velocity fields are compared to each other and to previously simulated three dimensional numerical results, indicating the accuracy of each method. The results show that the REEADM gives the best correlation with experimental performance results at design conditions (ϕ = 0.168) while the EADM gives the best correlation at low flow rates. A comparison of the velocity profiles shows that none of the three models predict the radial velocity distribution at low flow rates correctly, however the correlation improves at flow rates above ϕ = 0.105. In general the upstream velocity profiles, where reversed flow occurs through the fan, are poorly predicted at low flow rates. At the flow rates above ϕ = 0.137 the correlation between the velocity profiles for the simplified modes and the three dimensional results is good.


2019 ◽  
Vol 3 (1) ◽  
pp. 69-80
Author(s):  
Christian Camilleri ◽  
Luke Pace ◽  
Alex Rizzo

In water distribution networks, a substantial amount of Apparent Losses result from water-meter errors. This study aims to evaluate water-meter under-registration, specifically the effect of ageing on the meter measurement errors, controlled at different flow-rates. The study was initiated by establishing a holistic methodology highlighting the planning process and meter-testing procedure. The results achieved show that the metrological percentage meter error is highly pronounced at low flow-rates. In the case of medium to high flow-rates for one-year, three-year, and five-year-old class of meters, meter errors were not statistically significant. However, an opposite outcome for the same flow-rates resulted for the seven-year class meter.


2013 ◽  
Vol 6 (1) ◽  
pp. 119-149 ◽  
Author(s):  
C. M. Fontanazza ◽  
V. Notaro ◽  
V. Puleo ◽  
G. Freni

<p><strong>Abstract.</strong> In water supply systems, a considerable amount of apparent loss is caused by meter under-registration. Water meters are subject to intrinsic systemic error depending on the actual flow rates passing through them. Furthermore, the moving parts of the meter are subject to wear and tear that progressively reduce meter accuracy. The increase in systemic error is especially evident at low flow rates because of growing friction in the rotating mechanism, which requires a higher flow to start the meter (starting flow). The aim of this paper is to experimentally investigate metering error in an attempt to find a direct link between meter age, network pressure and apparent losses caused by the inability of the meter to accurately register the volume passing though it at low flow rates. The study was performed through laboratory experiments in which worn-out water meters were tested using a test bench. The results of the laboratory experiments show that ageing and pressure are both relevant parameters for determining meter starting flow. These results were then applied to assess the effects on apparent losses of the age of the meter, varying pressure values upstream of the meter (the pressure in the network where the meter is installed) and different patterns of flow rates passing through the device (the consumption pattern of the user). The presented results are useful for understanding the effects of operating conditions on water meter under-registration, which can aid water managers in implementing effective replacement campaigns.</p>


Author(s):  
G. Caignaert ◽  
B. Desmet ◽  
D. Stevenaert

A centrifugal research fan facility, designed for pressure measurements on the impeller blades is described in this paper. Results of mean and fluctuating pressures are presented, showing how the flow is three-dimensional and rather unsteady. An analysis of rotating stall at low flow rates is also presented.


Author(s):  
Linda Sadik ◽  
Badih Jawad ◽  
Munther Y. Hermez ◽  
Liping Liu

Abstract Optimizing the high efficiency design of centrifugal pumps requires a detailed understanding of the internal flow. The prediction of the flow inside the pump can be acquired by understanding the rotatory motion and the three-dimensional shape of the impellers, as well as its fundamental unsteady behavior. The flow inside a centrifugal pump is three-dimensional, unsettled and always associated with secondary flow structures. When a centrifugal pump operates under low flow rates, a secondary flow, known as recirculation, starts to begin. Inside this, the separation of flow increases, which creates vortices and cause local pressure to decrease, which induces cavitation. This phenomenon of recirculation will increase the Net Positive Suction Head Required (NPSHR). Improving the suction performance continues to remain a vital and continuous topic in the development and application of centrifugal pumps. In this research, the focal point is to enhance the pump suction performance under low flow rates by modifying the impeller design. This research entails a numerical simulation investigation on the addition of three different designs, each consisting of two cylindrical disks at the impeller inlet suction. It is hypothesized that these modifications will assist suppressing the recirculation phenomenon. The turbulent flow within the centrifugal pump was analyzed by applying the Reynolds-Averaged Navier-Stokes equations and the k–ϵ equations for turbulence modelling. The computational domain consists of the inlet, impeller, diffuser and outlet. Analysis of ΔP, torque data and pump efficiency was conducted. The application of CFD solvers to predict pump performance resulted in reduced prices for testing as well as pump development time. The numerical simulation concluded that placing 3-D multi-cylindrical disks at the impeller inlet section improved the centrifugal pump performance under low flow rates. The model design 1 resulted in a pump efficiency improvement of about 5% at low flow rates by lowering the amount of flow leaking back (re-circulation) through the internal suction.


ORL ◽  
2021 ◽  
pp. 1-5
Author(s):  
Jingjing Liu ◽  
Tengfang Chen ◽  
Zhenggang Lv ◽  
Dezhong Wu

<b><i>Introduction:</i></b> In China, nasal cannula oxygen therapy is typically humidified. However, it is difficult to decide whether to suspend nasal cannula oxygen inhalation after the nosebleed has temporarily stopped. Therefore, we conducted a preliminary investigation on whether the use of humidified nasal cannulas in our hospital increases the incidence of epistaxis. <b><i>Methods:</i></b> We conducted a survey of 176,058 inpatients in our hospital and other city branches of our hospital over the past 3 years and obtained information concerning their use of humidified nasal cannulas for oxygen inhalation, nonhumidified nasal cannulas, anticoagulant and antiplatelet drugs, and oxygen inhalation flow rates. This information was compared with the data collected at consultation for epistaxis during these 3 years. <b><i>Results:</i></b> No significant difference was found between inpatients with humidified nasal cannulas and those without nasal cannula oxygen therapy in the incidence of consultations due to epistaxis (χ<sup>2</sup> = 1.007, <i>p</i> &#x3e; 0.05). The same trend was observed among hospitalized patients using anticoagulant and antiplatelet drugs (χ<sup>2</sup> = 2.082, <i>p</i> &#x3e; 0.05). Among the patients with an inhaled oxygen flow rate ≥5 L/min, the incidence of ear-nose-throat (ENT) consultations due to epistaxis was 0. No statistically significant difference was found between inpatients with a humidified oxygen inhalation flow rate &#x3c;5 L/min and those without nasal cannula oxygen therapy in the incidence of ENT consultations due to epistaxis (χ<sup>2</sup> = 0.838, <i>p</i> &#x3e; 0.05). A statistically significant difference was observed in the incidence of ENT consultations due to epistaxis between the low-flow nonhumidified nasal cannula and nonnasal cannula oxygen inhalation groups (χ<sup>2</sup> = 18.428, <i>p</i> &#x3c; 0.001). The same trend was observed between the 2 groups of low-flow humidified and low-flow nonhumidified nasal cannula oxygen inhalation (χ<sup>2</sup> = 26.194, <i>p</i> &#x3c; 0.001). <b><i>Discussion/Conclusion:</i></b> Neither high-flow humidified nasal cannula oxygen inhalation nor low-flow humidified nasal cannula oxygen inhalation will increase the incidence of recurrent or serious epistaxis complications; the same trend was observed for patients who use anticoagulant and antiplatelet drugs. Humidification during low-flow nasal cannula oxygen inhalation can prevent severe and repeated epistaxis to a certain extent.


1992 ◽  
Vol 114 (3) ◽  
pp. 735-742 ◽  
Author(s):  
Y. T. Lin ◽  
M. Choi ◽  
R. Greif

A study has been made of the deposition of particles that occurs during the modified chemical vapor deposition (MCVD) process. The three-dimensional conservation equations of mass, momentum, and energy have been solved numerically for forced flow, including the effects of buoyancy and variable properties in a heated, rotating tube. The motion of the particles that are formed is determined from the combined effects resulting from thermophoresis and the forced and secondary flows. The effects of torch speed, rotational speed, inlet flow rate, tube radius, and maximum surface temperature on deposition are studied. In a horizontal tube, buoyancy results in circumferentially nonuniform temperature and velocity fields and particle deposition. The effect of tube rotation greatly reduces the nonuniformity of particle deposition in the circumferential direction. The process is chemical-reaction limited at larger flow rates and particle-transport limited at smaller flow rates. The vertical tube geometry has also been studied because its symmetric configuration results in uniform particle deposition in the circumferential direction. The “upward” flow condition results in a large overall deposition efficiency, but this is also accompanied by a large “tapered entry length.”


Author(s):  
Yo Han Jung ◽  
Young Uk Min ◽  
Jin Young Kim

This paper presents a numerical investigation of the effect of tip clearance on the suction performance and flow characteristics at different flow rates in a vertical mixed-flow pump. Numerical analyses were carried out by solving three-dimensional Reynolds-averaged Navier-Stokes equations. Steady computations were performed for three different tip clearances under noncavitating and cavitating conditions at design and off-design conditions. The pump performance test was performed for the mixed-flow pump and numerical results were validated by comparing the experimental data for a system characterized by the original tip clearance. It was shown that for large tip clearance, the head breakdown occurred earlier at the design and high flow rates. However, the head breakdown was quite delayed at low flow rate. This resulted from the cavitation structure caused by the tip leakage flow at different flow rates.


Sign in / Sign up

Export Citation Format

Share Document