The Use of Dehumidifiers in Desiccant Cooling and Dehumidification Systems

1986 ◽  
Vol 108 (3) ◽  
pp. 684-692 ◽  
Author(s):  
E. Van den Bulck ◽  
J. W. Mitchell ◽  
S. A. Klein

The use of rotary dehumidifiers in gas-fired open-cycle desiccant cooling systems is investigated by analyzing the performance of the rotary heat exchanger–rotary dehumidifier subsystem. For a given cooling load, the required regeneration heat supply can be minimized by choosing appropriate values for the regeneration air mass flow rate and the wheel rotation speed. A map is presented showing optimal values for rotational speed and regeneration flow rate as functions of the regeneration air inlet temperature and the process air inlet humidity ratio. This regeneration temperature is further optimized as a function of the process humidity ratio. In the analysis, the control strategy adjusts the process air mass flow rate to provide the required cooling load. Additional control options are considered and the sensitivity of the regeneration heat required to the wheel speed, regeneration air mass flow rate, and inlet temperature is discussed. Experimental data reported in the literature are compared with the analytical results and indicate good agreement.

Author(s):  
Ahmet Topal ◽  
Onder Turan

AbstractExergy efficiencies of the gas turbine become an important issue in recent years and by the way conducted studies regarding to this subject shows that the highest exergy destruction is observed in the combustor and afterburner modules. Therefore it is beneficial to perform analyses that are specific to the combustor exergy efficiency. This study includes the energy$\left( {{\eta _{cc}}} \right)$and exergy efficiencies$\left( {{\eta _{ex}}} \right)$(thermo-efficiencies) of a tubular combustor for different inlet conditions. Both of the first law and second law efficiencies have been performed on the experimental data and efficiency trends are investigated for changing aerodynamic conditions. Combustor tests have been conducted in an atmospheric test rig and combustor air inlet temperature$\left( {{T_{03}}} \right)$, air mass flow rate$\left( {{{\dot m}_a}} \right)$and fuel mass flow rate$\left( {{{\dot m}_f}} \right)$have been set for the pre-defined conditions. Moreover, exhaust gas emissions were measured by using a gas analyzer system. In the study, highest energy and exergy efficiencies have been obtained at minimum aerodynamic loading condition as 99.0 % and 70.2 % respectively. Moreover efficiencies have the lowest value as 92.7 % and 54.0 % at the maximum aerodynamic loading condition. To summarize, this study aims to show the energy and exergy trends by changing inlet conditions of a tubular combustor in the atmospheric test rig.


Energies ◽  
2020 ◽  
Vol 13 (9) ◽  
pp. 2225
Author(s):  
Junpeng Fu ◽  
Jiuju Cai

The vertical sinter cooling bed (VSCB) is a high-efficiency energy-saving and environmentally friendly waste heat recovery equipment. In this study, a computational fluid dynamics (CFD) convection model was established to reveal the typical factors on the thermodynamic performance in VSCB. Indeed, a multiple performance optimal algorithm based on the Taguchi-grey relational analysis (GRA) method was first applied to investigate the effects of geometric and operational factors, including the diameter of the bed, height of the bed, air mass flow rate, air inlet temperature, and sinter mass flow rate, on improving the heat transfer (Ex) and hydrodynamic performance (Pdrop) and obtain the optimum combination of each factor in VSCB. The results found that the diameter of the bed was the most influential factor contributing the multiple types of performance with a contribution rate of 70.51%, followed by the air mass flow rate (15.84%), while the height of the bed (0.27%) exerted a limited effect on the performance of multiple processes. The optimal combination of factors (A1B5C5D5E1) was compared with the initially selected parameters by performing a confirmation test. The performances of heat transfer and hydrodynamics were improved by the Taguchi with the GRA method.


Author(s):  
M. Fatouh

This paper reports the results of an experimental investigation on a pilot compression chiller (4 kW cooling capacity) working with R401a and R134a as R12 alternatives. Experiments are conducted on a single-stage vapor compression refrigeration system using water as a secondary working fluid through both evaporator and condenser. Influences of cooling water mass flow rate (170–1900 kg/h), cooling water inlet temperature (27–43°C) and chilled water mass flow rate (240–1150 kg/h) on performance characteristics of chillers are evaluated for R401a, R134a and R12. Increasing cooling water mass flow rate or decreasing its inlet temperature causes the operating pressures and electric input power to reduce while the cooling capacity and coefficient of performance (COP) to increase. Pressure ratio is inversely proportional while actual loads and COP are directly proportional to chilled water mass flow rate. The effect of cooling water inlet temperature, on the system performance, is more significant than the effects of cooling and chilled water mass flow rates. Comparison between R12, R134a and R401a under identical operating conditions revealed that R401a can be used as a drop-in refrigerant to replace R12 in water-cooled chillers.


2003 ◽  
Vol 125 (1) ◽  
pp. 104-113 ◽  
Author(s):  
Chang-Yuan Liu ◽  
Ying-Huei Hung

Both experimental and theoretical investigations on the heat transfer and flow friction characteristics of compact cold plates have been performed. From the results, the local and average temperature rises on the cold plate surface increase with increasing chip heat flux or decreasing air mass flow rate. Besides, the effect of chip heat flux on the thermal resistance of cold plate is insignificant; while the thermal resistance of cold plate decreases with increasing air mass flow rate. Three empirical correlations of thermal resistance in terms of air mass flow rate with a power of −0.228 are presented. As for average Nusselt number, the effect of chip heat flux on the average Nusselt number is insignificant; while the average Nusselt number of the cold plate increases with increasing Reynolds number. An empirical relationship between Nu¯cp and Re can be correlated. In the flow frictional aspect, the overall pressure drop of the cold plate increases with increasing air mass flow rate; while it is insignificantly affected by chip heat flux. An empirical correlation of the overall pressure drop in terms of air mass flow rate with a power of 1.265 is presented. Finally, both heat transfer performance factor “j” and pumping power factor “f” decrease with increasing Reynolds number in a power of 0.805; while they are independent of chip heat flux. The Colburn analogy can be adequately employed in the study.


2021 ◽  
Vol 39 (4) ◽  
pp. 1225-1235
Author(s):  
Ajay K. Gupta ◽  
Manoj Kumar ◽  
Ranjit K. Sahoo ◽  
Sunil K. Sarangi

Plate-fin heat exchangers provide a broad range of applications in many cryogenic industries for liquefaction and separation of gasses because of their excellent technical advantages such as high effectiveness, compact size, etc. Correlations are available for the design of a plate-fin heat exchanger, but experimental investigations are few at cryogenic temperature. In the present study, a cryogenic heat exchanger test setup has been designed and fabricated to investigate the performance of plate-fin heat exchanger at cryogenic temperature. Major parameters (Colburn factor, Friction factor, etc.) that affect the performance of plate-fin heat exchangers are provided concisely. The effect of mass flow rate and inlet temperature on the effectiveness and pressure drop of the heat exchanger are investigated. It is observed that with an increase in mass flow rate effectiveness and pressure drop increases. The present setup emphasis the systematic procedure to perform the experiment based on cryogenic operating conditions and represent its uncertainties level.


2019 ◽  
Vol 4 (2) ◽  
Author(s):  
Hamisu A Dandajeh ◽  
Talib O Ahmadu

This paper presents an experimental investigation on the influence of engine speed on the combustion characteristics of a Gardener compression ignition engine fueled with rapeseed methyl esther (RME). The engine has a maximum power of 14.4 kW and maximum speed of 1500 rpm. The experiment was carried out at speeds of 750 and 1250 rpm under loads of 4, 8, 12, 16 and 18 kg. Variations of cylinder pressure with crank angle degrees and cylinder volume have been examined. It was found that RME demonstrated short ignition delay primarily due to its high cetane number and leaner fuel properties (equivalence ratio (φ) = 0.22 at 4kg). An increase in thermal efficiency but decrease in volumetric efficiency was recorded due to increased brake loads. Variations in fuel mass flow rate, air mass flow rate, exhaust gas temperatures and equivalence ratio with respect to brake mean effective pressure at engine speeds of 750 and 1250 rpm were also demonstrated in this paper. Higher engine speed of 1250 rpm resulted in higher fuel and air mass flow rates, exhaust temperature, brake power and equivalent ratio but lower volumetric efficiency. Keywords— combustion characteristics, engine performance, engine speed, rapeseed methyl Esther


Author(s):  
Min Zhang ◽  
Dara W. Childs

Abstract With the increasing demand of the oil & gas industry, many pump companies are developing multiphase pumps, which can handle liquid-gas flow directly without separating the liquid from a mixed flow. The see-through labyrinth seal is one of the popular types of non-contact annular seals that act as a balancing piston seal to reduce the axial thrust of a high-performance centrifugal pump. The see-through labyrinth seal also generates reaction forces that can significantly impact the rotordynamic performance of the pump. Multiphase pumps are expected to operate from pure-liquid to pure-gas conditions. Zhang et al. (2019) conducted a comprehensive experimental study on the performance (leakage and rotordynamic coefficients) of a see-through labyrinth seal under mainly-gas conditions. This paper continues Zhang et al.’s (2019) research and studies the performance of the see-through TOS (tooth-on-stator) labyrinth seal under mainly-liquid conditions. The test seal’s inner diameter, length, and radial clearance are 89.256 mm, 66.68 mm, and 0.178 mm, respectively. The test fluid is a mixture of air and silicone oil (PSF-5cSt), and the inlet GVF (gas volume fraction) varies from zero to 12%. Tests are conducted at an exit pressure of 6.9 bars, an inlet temperature of 39.1 °C, three pressure drops PDs (27.6 bars, 34.5 bars, and 48.3 bars), and three rotating speeds ω (5 krpm, 10 krpm, and 15 krpm). The seal is always concentric with the rotor, and there is no intentional fluid pre-rotation at the seal inlet. The air presence in the oil flow significantly impacts the leakage as well as the dynamic forces of the test seal. The first air increment (increasing inlet GVF from 0% to 3%) slightly increases the leakage mass flow rate, while further air increments steadily decrease the leakage mass flow rate. For all test conditions, the leakage mass flow rate does not change as ω increases from 5 krpm to 10 krpm but decreases as ω is further increased to 15 krpm. The reduction in the leakage mass flow rate indicates that there is an increase in the friction factor, and there could be a highly possible flow regime change as ω increases from 10 krpm to 15 krpm. For ω ≤ 10 krpm, effective stiffness Keff increases as inlet GVF increases. Keff represents the test seal’s total centering force on the pump rotor. The increase of Keff increases the seal’s centering force and would increase the pump rotor’s critical speeds. Ceff indicates the test seal’s total damping force on the pump rotor. For ω ≤ 10 krpm, Ceff first decreases as inlet GVF increases from zero to 3%, and then remains unchanged as inlet GVF is further increased to 12%. For ω = 15 krpm, Keff first increases as inlet GVF increases from zero to 3% and then decreases as inlet GVF is further increased. As inlet GVF increases, Ceff steadily decreases for ω = 15 krpm.


Energies ◽  
2020 ◽  
Vol 13 (5) ◽  
pp. 1105 ◽  
Author(s):  
Carlo Carcasci ◽  
Lapo Cheli ◽  
Pietro Lubello ◽  
Lorenzo Winchler

This paper presents an off-design analysis of a gas turbine Organic Rankine Cycle (ORC) combined cycle. Combustion turbine performances are significantly affected by fluctuations in ambient conditions, leading to relevant variations in the exhaust gases’ mass flow rate and temperature. The effects of the variation of ambient air temperature have been considered in the simulation of the topper cycle and of the condenser in the bottomer one. Analyses have been performed for different working fluids (toluene, benzene and cyclopentane) and control systems have been introduced on critical parameters, such as oil temperature and air mass flow rate at the condenser fan. Results have highlighted similar power outputs for cycles based on benzene and toluene, while differences as high as 34% have been found for cyclopentane. The power output trend with ambient temperature has been found to be influenced by slope discontinuities in gas turbine exhaust mass flow rate and temperature and by the upper limit imposed on the air mass flow rate at the condenser as well, suggesting the importance of a correct sizing of the component in the design phase. Overall, benzene-based cycle power output has been found to vary between 4518 kW and 3346 kW in the ambient air temperature range considered.


Author(s):  
Yuan Li ◽  
Hao Zhou ◽  
Ning Li ◽  
Kefa Cen

This paper presents a study of ethanol jet spray flame characteristics in a hot-diluted oxidant with different co-flow oxygen concentrations and fuel/air mass flow rate ratios (MF/MA ratios) through advance image processing technique. An air-blast atomizer was located in a McKenna burner which was utilized to provide stable combustion surroundings and variable combustion atmosphere for ethanol jet spray. The co-flow oxygen concentrations were set to 5%, 10%, 15% and 21% (by volume) by adjusting the mass flow rates of CH4, O2 and N2. The MF/MA ratios were set to 0.245, 0.490, 0.735, and 0.980 by adjusting the fuel mass flow rate and the carrier air mass flow rate. A high-speed RGB CCD camera was employed to capture spray flame images continuously. Spray flame edge is detected using an auto-adaptive edge-detection algorithm which could detect the spray flame edge continuously and clearly. A flame zone is defined as the region surrounded by the detected flame edge to obtain flame parameters. Spray flame characteristics are described using the measured flame parameters, involving flame area, length, brightness, nonuniformity and temperature which are derived from the spray flame images. Spray flame area, length, brightness and nonuniformity are extracted through image processing technique directly. Moreover, two-dimensional (2D) temperature profiling of spray flame is obtained by coupling image processing technique with two-color pyrometry based on Planck’s radiation law. The effects of co-flow oxygen concentration and MF/MA ratio on spray flame characteristics are investigated in this work. The spray flame parameters are observed to be sensitive to both co-flow oxygen concentration and MF/MA ratio. The results show that the fuel mass flow rate (MF) has opposite effects on spray flame characteristics compared with the carrier air mass flow rate (MA) in hot-diluted oxidant. Spray flame area and length are shown to decrease for higher co-flow oxygen concentrations, while spray flame brightness, uniformity and temperature are observed to increase for higher co-flow oxygen concentrations, owing to the enhancement of the combustion rate. A higher MF/MA ratio leads to higher spray flame area, length, brightness, uniformity and temperature, due to the increase of the droplet residence time or droplet concentration in hot-diluted oxidant. In the same MF/MA ratio, spray flame area and length are found to be smaller at a higher fuel flow rate (or carrier air flow rate). However, spray flame brightness, uniformity and temperature are demonstrated to be enhanced at a higher fuel flow rate (or carrier air flow rate). (CSPE)


2010 ◽  
Vol 202 (1-3) ◽  
pp. 62-70 ◽  
Author(s):  
Cecilia Arakaki ◽  
Ali Ghaderi ◽  
Arild Sæther ◽  
Chandana Ratnayake ◽  
Gisle G. Enstad

Sign in / Sign up

Export Citation Format

Share Document