The Effects of Vibration and Pulsation on Metal Removal by a Plasma Torch

1973 ◽  
Vol 95 (2) ◽  
pp. 240-245 ◽  
Author(s):  
G. T. Dyos ◽  
J. Lawton

An experimental study has been carried out on the effects of workpiece vibration and gas pulsations on metal removal rates using plasma jets. In the case of workpiece vibration, increases in removal rates of up to 30 percent were found, which can be accounted for in terms of capillary waves set up in the melt. The influence of pulsation of gas flow velocity and arc current at modulation levels of 10 percent was found to be negligible. A theoretical model has been developed which explains the results in terms of the development of resonance capillary waves in the molten metal and predicts the average depth of the layer of molten metal.

Author(s):  
Yanxia Li ◽  
Zhongliang Liu ◽  
Yan Wang ◽  
Jiaming Liu

A numerical model on methane/air combustion inside a small Swiss-roll combustor was set up to investigate the flame position of small-scale combustion. The simulation results show that the combustion flame could be maintained in the central area of the combustor only when the speed and equivalence ratio are all within a narrow and specific range. For high inlet velocity, the combustion could be sustained stably even with a very lean fuel and the flame always stayed at the first corner of reactant channel because of the strong convection heat transfer and preheating. For low inlet velocity, small amounts of fuel could combust stably in the central area of the combustor, because heat was appropriately transferred from the gas to the inlet mixture. Whereas, for the low premixed gas flow, only in certain conditions (Φ = 0.8 ~ 1.2 when ν0 = 1.0m/s, Φ = 1.0 when ν0 = 0.5m/s) the small-scale combustion could be maintained.


2010 ◽  
Vol 129-131 ◽  
pp. 692-696
Author(s):  
Jian Bing Meng ◽  
Xiao Juan Dong ◽  
Chang Ning Ma

A mathematical model was developed to describe the oscillating amplitude of the plasma arc injected transverse to an external transverse alternating magnetic field. The characteristic of plasma arc under the external transverse alternating magnetic field imposed perpendicular to the plasma current was discussed. The effect of processing parameters, such as flow rate of working gas, arc current, magnetic flux density and the standoff from the nozzle to the workpiece, on the oscillation of plasma arc were also analyzed. The results show that it is feasible to adjust the shape of the plasma arc by the transverse alternating magnetic field, which expands the region of plasma arc thermal treatment upon the workpiece. Furthermore, the oscillating amplitude of plasma arc decreases with decrease of the magnetic flux density. Under the same magnetic flux density, more gas flow rate, more arc current, and less standoff cause the oscillating amplitude to decrease. The researches have provided a deeper understanding of adjusting of plasma arc characteristics.


Plants ◽  
2021 ◽  
Vol 10 (7) ◽  
pp. 1461
Author(s):  
Roberto Braglia ◽  
Lorenza Rugnini ◽  
Sara Malizia ◽  
Francesco Scuderi ◽  
Enrico Luigi Redi ◽  
...  

Increasing levels of freshwater contaminants, mainly due to anthropogenic activities, have resulted in a great deal of interest in finding new eco-friendly, cost-effective and efficient methods for remediating polluted waters. The aim of this work was to assess the feasibility of using a green microalga Desmodesmus sp., a cyanobacterium Nostoc sp. and a hemicryptophyte Ampelodesmos mauritanicus to bioremediate a water polluted with an excess of nutrients (nitrogen and phosphorus) and heavy metals (copper and nickel). We immediately determined that Nostoc sp. was sensitive to metal toxicity, and thus Desmodesmus sp. was chosen for sequential tests with A. mauritanicus. First, A. mauritanicus plants were grown in the ‘polluted’ culture medium for seven days and were, then, substituted by Desmodesmus sp. for a further seven days (14 days in total). Heavy metals were shown to negatively affect both the growth rates and nutrient removal capacity. The sequential approach resulted in high metal removal rates in the single metal solutions up to 74% for Cu and 85% for Ni, while, in the bi-metal solutions, the removal rates were lower and showed a bias for Cu uptake. Single species controls showed better outcomes; however, further studies are necessary to investigate the behavior of new species.


Author(s):  
M. Vardelle ◽  
P. Fauchais ◽  
A. Vardelle ◽  
A.C. Léger

Abstract A study of the flattening and cooling of particles plasma-sprayed on a substrate is presented. The characteristic parameters of the splats are linked to the parameters of the impacting particles by using an experimental device consisting of a phase Doppler particle analyzer and a high-speed pyrometer. However, during the long experiments required to get reliable correlations, it was observed that variations in plasma spray operating conditions may alter the particles behavior in the plasma jet. Therefore, a simple and easy-to-use system was developed to control in real time the spray jet. In this paper, the effect of carrier gas flow rate, arc current and powder mass flow rate is investigated. The results on zirconia and alumina powders show the capability of the technique to sense the particle spray position and width.


2013 ◽  
Vol 68 (12) ◽  
pp. 2527-2533 ◽  
Author(s):  
Mary Kay Camarillo ◽  
William T. Stringfellow ◽  
Jeremy S. Hanlon ◽  
Elizabeth Basha

Controlling odours from sanitary sewer systems is challenging as a result of the expansive nature of these systems. Addition of oxidizing chemicals is often practiced as a mitigation strategy. One alternative is to remove odorous compounds in the gases vented from manholes using adsorptive media. In this study, odour control devices located at manholes were observed to determine the ability of these systems to reduce hydrogen sulphide from vented gases. The odour control devices incorporated pressure regulation to control gas flow out of manhole covers and adsorptive media to remove hydrogen sulphide in the vented gases prior to release. Pressure regulation was accomplished using a variable volume bladder and two pressure relief valves that permitted gas flow when pressures exceeded 1.3 to 2.5 cm water column. The reduction in gas flow vented from manholes was intended to extend the service life of the adsorptive media, as compared with odour control devices that do not incorporate pressure modulation. Devices were deployed at four locations and three adsorptive media were tested. Although measured collection system hydrogen sulphide concentrations varied from zero to over 1,000 ppm, the removal rates observed using odour control devices were typically above 90%. The lower removal rates observed at one of the sites (50.5 ± 36.1%) appeared related to high gas flow rates being emitted at this location. Activated carbon was used in most of the tests, although use of iron media resulted in the highest removal observed: 97.8 ± 3.6%. The expected service life of the adsorptive media contained within the odour control devices is a function of site-specific hydrogen sulphide concentrations and gas flow rates. The units used in this study were in service for more than 8 to 12 months prior to requiring media replacement.


2021 ◽  
Vol 2 (446) ◽  
pp. 99-104
Author(s):  
S.R. Rasulov ◽  
G.R. Mustafayeva

This scientific article is devoted to the problems associated with the flow of suspensions and emulsions and some simplifications of the real picture of the flow of a polydisperse medium are made. It is also stipulated that differential equations characterizing the motion of suspensions and emulsions should take into account the fundamental discontinuity of the medium and the physicochemical processes of heat and mass transfer occurring in it. Taking into account all these factors, a general equation for multiphase systems is proposed with certain simplifications that do not change. The behavior of particles in two-phase systems, their concentration, collision and coagulation are considered. As a result, it was concluded that there is a multifactorial interaction and mutual influence of both phases in a dispersed flow. A differential equation of motion of a single i-th spherical particle in suspension was proposed, and an equation describing the drag force of a solid spherical particles. Equations of conservation of mass and momentum are presented for one-dimensional laminar motion of two incompressible phases in a gravity field with the same pressure in the phases. Having studied the parameters of the flow of fine particles in a turbulent gas flow, some assumptions were made. It was found that the pulsating motion of particles, performed by them during one period of gas pulsations, can be represented as a change in the pulsating gas velocity in time. The parameter of entrainment of particles by a pulsating medium is an important characteristic in determining the transport coefficients in a turbulent flow. It is concluded that the presence of various kinds of particles in the liquid complicates the problem of solving hydromechanical problems in turbulent and laminar flow, and the assumptions given in the work facilitate the study of this problem.


Author(s):  
S. Janisson ◽  
A. Vardelle ◽  
J.F. Coudert ◽  
B. Pateyron ◽  
P. Fauchais ◽  
...  

Abstract In D.C. plasma guns used for plasma spraying, the properties of the plasma forming-gas control, to a great extent, the characteristics of the plasma jet and the momentum, heat and mass transfer to the particles injected in the flow. This paper deals with mixtures of argon, helium and hydrogen and the effect of the volume composition of these mixtures on the dynamic and static behavior of the plasma jet. Both were investigated from the measurements of arc voltage and gas velocity. Correlations between these parameters and the operating variables (arc current, gas flow rate, gas mixture composition) were established from a dimensional analysis. The results were supported by the calculation of the thermodynamic and transport properties of the ternary gas mixtures used in this study.


2018 ◽  
Vol 932 ◽  
pp. 124-128
Author(s):  
Wei Feng Liu ◽  
Xue Wei Li ◽  
Wen Bo Dong ◽  
Le Bo ◽  
Yi Min Zhu ◽  
...  

Poly-γ-glutamic acid (γ-PGA) produced by Bacillus pumilus C2 was employed to remove heavy metals from sewage of magnesium - based exhaust gas cleaning system (Mg-EGCS). The components of heavy metals in the sewage were detailed analyzed. On the base of the analytical results, the effects of addition amount of γ-PGA, adsorption time, temperature and NaCl concentration on the removal efficiency of typical heavy metals were further investigated. The optimal removal rates of heavy metals were obtained at the γ-PGA dosage of 9 g/L and adsorption duration of 30 min. The γ-PGA had excellent tolerance for high temperatures up to 80°C and exhibited steady heavy metal removal efficiency in NaCl concentrations of 0 – 24%. Under the optimal conditions, the removal rates of Zn, Cr, V, Cd, Pb and Ni by γ-PGA in a real sewage of Mg-EGCS achieved 53.6%, 100%, 49.2%, 72.7%, 33.7% and 39.9% respectively.


Sensors ◽  
2019 ◽  
Vol 19 (2) ◽  
pp. 360 ◽  
Author(s):  
Guillaume Kock ◽  
Philippe Combette ◽  
Marwan Tedjini ◽  
Markus Schneider ◽  
Caroline Gauthier-Blum ◽  
...  

A new single-axis gas thermal gyroscope without proof mass is presented in this paper. The device was designed, manufactured and experimentally characterized. The obtained results were compared to numerical simulation. The working principle of the gyroscope is based on the deflection of a laminar gas flow caused by the Coriolis effect. A bidirectional hot air flow is generated by alternating activation of two suspended resistive micro-heaters. The heated gas is encapsulated in a semi-open cavity and the gas expands primarily inside the cavity. The thermal expansion gyroscope has a simple structure. Indeed, the device is composed of a micromachined cavity on which three bridges are suspended. The central bridge is electrically separated into two segments enabling to set up two heaters which may be supplied independently from each other. The two other bridges, placed symmetrically on each side of the central bridge, are equipped with temperature detectors which measure variations in gas temperature. The differential temperature depends on the rotational velocity applied to the system. Various parameters such as the heating duty cycle, the type of the gas and the power injected into the heaters have been studied to define the optimal working conditions required to obtain the highest level of sensitivity over a measurement range of around 1000°/s. The robustness of the device has also been tested and validated for a shock resistance of 10,000 g for a duration of 400 µs.


2010 ◽  
Vol 645-648 ◽  
pp. 849-852 ◽  
Author(s):  
Florentina Niebelschütz ◽  
Thomas Stauden ◽  
Katja Tonisch ◽  
Jörg Pezoldt

In order to realize complex three dimensional or free standing structures on SiC substrates, an undercut, i.e. a selective isotropic etching process of SiC, is required. This was realized using an electron cyclotron resonance etching set up with pure SF6 and a SF6/Ar gas composition at elevated substrate temperatures. Above 350°C a significant lateral etch component was observed, which rose to a value of 50-70 nm/min increasing the substrate temperature up to 570°C during the etching process. Depending on substrate temperature the etching profiles and surface roughness were studied. Based on an analysis of the influence of microwave power, working pressure, bias voltage, gas flow and gas mixture on the etching behavior a novel isotropic, high selective, residue free etch process for SiC was developed, which allows for example the fabrication of piezoelectric actuated AlGaN/GaN resonators grown on SiC substrates.


Sign in / Sign up

Export Citation Format

Share Document