Analysis of Single- and Two-Phase Flows in Turbopump Inducers

1967 ◽  
Vol 89 (4) ◽  
pp. 577-586 ◽  
Author(s):  
P. Cooper

A model is developed for analytically determining pump inducer performance in both the single-phase and cavitating flow regimes. An equation of state for vaporizing flow is used in an approximate, three-dimensional analysis of the flow field. The method accounts for losses and yields internal distributions of fluid pressure, velocity, and density together with the resulting overall efficiency and pressure rise. The results of calculated performance of two sample inducers are presented. Comparison with recent theory for fluid thermal effects on suction head requirements is made with the aid of a resulting dimensionless vaporization parameter.

2010 ◽  
Vol 132 (4) ◽  
Author(s):  
Yoon Jo Kim ◽  
Yogendra K. Joshi ◽  
Andrei G. Fedorov ◽  
Young-Joon Lee ◽  
Sung-Kyu Lim

It is now widely recognized that the three-dimensional (3D) system integration is a key enabling technology to achieve the performance needs of future microprocessor integrated circuits (ICs). To provide modular thermal management in 3D-stacked ICs, the interlayer microfluidic cooling scheme is adopted and analyzed in this study focusing on a single cooling layer performance. The effects of cooling mode (single-phase versus phase-change) and stack/layer geometry on thermal management performance are quantitatively analyzed, and implications on the through-silicon-via scaling and electrical interconnect congestion are discussed. Also, the thermal and hydraulic performance of several two-phase refrigerants is discussed in comparison with single-phase cooling. The results show that the large internal pressure and the pumping pressure drop are significant limiting factors, along with significant mass flow rate maldistribution due to the presence of hot-spots. Nevertheless, two-phase cooling using R123 and R245ca refrigerants yields superior performance to single-phase cooling for the hot-spot fluxes approaching ∼300 W/cm2. In general, a hybrid cooling scheme with a dedicated approach to the hot-spot thermal management should greatly improve the two-phase cooling system performance and reliability by enabling a cooling-load-matched thermal design and by suppressing the mass flow rate maldistribution within the cooling layer.


2014 ◽  
Vol 541-542 ◽  
pp. 1288-1291
Author(s):  
Zhi Feng Dong ◽  
Quan Jin Kuang ◽  
Yong Zheng Gu ◽  
Rong Yao ◽  
Hong Wei Wang

Calculation fluid dynamics software Fluent was used to conduct three-dimensional numerical simulation on gas-liquid two-phase flow field in a wet flue gas desulfurization scrubber. The k-ε model and SIMPLE computing were adopted in the analysis. The numerical simulation results show that the different gas entrance angles lead to internal changes of gas-liquid two-phase flow field, which provides references for reasonable parameter design of entrance angle in the scrubber.


2016 ◽  
Vol 139 (1) ◽  
Author(s):  
A. Hildebrandt ◽  
F. Schilling

The present paper deals with the numerical and experimental investigation of the effect of return channel (RCH) dimensions of a centrifugal compressor stage on the aerodynamic performance. Three different return channel stages were investigated, two stages comprising three-dimensional (3D) return channel blades and one stage comprising two-dimensional (2D) RCH vanes. The analysis was performed regarding both the investigation of overall performance (stage efficiency, RCH total pressure loss coefficient) and detailed flow-field performance. For detailed experimental flow-field investigation at the stage exit, six circumferentially traversed three-hole probes were positioned downstream the return channel exit in order to get two-dimensional flow-field information. Additionally, static pressure wall measurements were taken at the hub and shroud pressure and suction side (SS) of the 2D and 3D return channel blades. The return channel system overall performance was calculated by measurements of the circumferentially averaged 1D flow field downstream the diffuser exit and downstream the stage exit. Dependent on the type of return channel blade, the numerical and experimental results show a significant effect on the flow field overall and detail performance. In general, satisfactory agreement between computational fluid dynamics (CFD)-prediction and test-rig measurements was achieved regarding overall and flow-field performance. In comparison with the measurements, the CFD-calculated stage performance (efficiency and pressure rise coefficient) of all the 3D-RCH stages was slightly overpredicted. Very good agreement between CFD and measurement results was found for the static pressure distribution on the RCH wall surfaces while small CFD-deviations occur in the measured flow angle at the stage exit, dependent on the turbulence model selected.


2003 ◽  
Vol 285 (5) ◽  
pp. H1956-H1965 ◽  
Author(s):  
Ares Pasipoularides ◽  
Ming Shu ◽  
Ashish Shah ◽  
Alessandro Tucconi ◽  
Donald D. Glower

Intraventricular diastolic right ventricular (RV) flow field dynamics were studied by functional imaging using three-dimensional (3D) real-time echocardiography with sonomicrometry and computational fluid dynamics in seven awake dogs at control with normal wall motion (NWM) and RV volume overload with diastolic paradoxical septal motion. Burgeoning flow cross section between inflow anulus and chamber walls induces a convective pressure rise, which represents a “convective deceleration load” (CDL). High spatiotemporal resolution dynamic pressure and velocity distributions of the intraventricular RV flow field revealed time-dependent, subtle interactions between intraventricular local acceleration and convective pressure gradients. During the E-wave upstroke, the total pressure gradient along intraventricular flow is the algebraic sum of a pressure decrease contributed by local acceleration and a pressure rise contributed by a convective deceleration that partially counterbalances the local acceleration gradient. This underlies the smallness of early diastolic intraventricular gradients. At peak volumetric inflow, local acceleration vanishes and the total adverse intraventricular gradient is convective. During the E-wave downstroke, the strongly adverse gradient embodies the streamwise pressure augmentations from both local and convective decelerations. It induces flow separation and large-scale vortical motions, stronger in NWM. Their dynamic corollaries on intraventricular pressure and velocity distributions were ascertained. In the NWM pattern, the strong ring-like vortex surrounding the central core encroaches on the area available for flow toward the apex. This results in higher linear velocities later in the downstroke of the E wave than at peak inflow rate. The augmentation of CDL by ventriculoannular disproportion may contribute to E wave and E-to-A ratio depression with chamber dilatation.


2011 ◽  
Vol 418-420 ◽  
pp. 2006-2011
Author(s):  
Rui Zhang ◽  
Cheng Jian Sun ◽  
Yue Wang

CFD simulation and PIV test technology provide effective solution for revealing the complex flow of hydrodynamic coupling’s internal flow field. Some articles reported that the combination of CFD simulation and PIV test can be used for analyzing the internal flow field of coupling, and such analysis focuses on one-phase flow. However, most internal flow field of coupling are gas-fluid two-phase flow under the real operation conditions. In order to reflect the gas-fluid two-phase flow of coupling objectively, CFD three-dimensional numerical simulation is conducted under two typical operation conditions. In addition, modern two-dimensional PIV technology is used to test the two-phase flow. This method of combining experiments and simulation presents the characteristics of the flow field when charging ratios are different.


2012 ◽  
Vol 2012 ◽  
pp. 1-9 ◽  
Author(s):  
Pin Liu ◽  
Norimasa Shiomi ◽  
Yoichi Kinoue ◽  
Ying-zi Jin ◽  
Toshiaki Setoguchi

In order to clarify the effect of rotor inlet geometry of half-ducted propeller fan on performance and velocity fields at rotor outlet, the experimental investigation was carried out using a hotwire anemometer. Three types of inlet geometry were tested. The first type is the one that the rotor blade tip is fully covered by a casing. The second is that the front one-third part of blade tip is opened and the rest is covered. The third is that the front two-thirds are opened and the rest is covered. Fan test and internal flow measurement at rotor outlet were conducted about three types of inlet geometry. At the internal flow measurement, a single slant hotwire probe was used and a periodical multisampling technique was adopted to obtain the three-dimensional velocity distributions. From the results of fan test, the pressure-rise characteristic drops at high flowrate region and the stall point shifts to high flowrate region, when the opened area of blade tip increases. From the results of velocity distributions at rotor outlet, the region with high axial velocity moves to radial inwards, the circumferential velocity near blade tip becomes high, and the flow field turns to radial outward, when the opened area increases.


2005 ◽  
Vol 127 (4) ◽  
pp. 479-486
Author(s):  
Bin Liu ◽  
Mauricio Prado

For any pumping artificial lift system in the petroleum industry, the free gas significantly affects the performance of the pump and the system above the pump. A model, though not a complete two-phase flow model, has been developed for the effective prediction of separation efficiency across a wide range of production conditions. The model presented is divided into two main parts, the single-phase flow-field solution and the bubble-tracking method. The first part of the model solves the single-phase liquid flow field using the computational fluid dynamics approach. Then, a simple bubble-tracking method was applied to estimate the down-hole natural separation efficiency for two-phase flow. A comparison between the results of the model and the experimental data was conducted. It shows a very good agreement with the experimental data for lower gas void fractions (bubble flow regime).


Author(s):  
A. Mehdizadeh ◽  
S. A. Sherif ◽  
W. E. Lear

A fundamental study of heat transfer characteristics of two-phase slug flow in microchannels is carried out employing the Volume-of-Fluid (VOF) method. Despite of the fact that numerical simulations of two-phase flows in microchannels have been attempted by many investigators, most efforts seem to have failed in correctly capturing the flow physics, especially those pertaining to the slug flow regime characteristics. The presence of a thin liquid film in the order of 10 μm around the bubble is a contributing factor to the above difficulty. Typically, liquid films have a significant effect on the flow field and heat transfer characteristics. In the simulations reported in this paper, the film is successfully captured and a very high local convective heat transfer coefficient is observed in the film region. A strong coupling between the conductive heat transfer in the solid wall and the convective heat transfer in the flow field is observed and characterized. Results showed that unsteady heat transfer through the solid wall in the axial direction is comparable to that in the radial direction. Results also showed that a fully developed condition could be achieved fairly quickly compared to single-phase flows. The fully developed condition is defined based on the Peclet number (Pe) and a dimensionless length of the liquid slug. Local and time-averaged Nusselt numbers for slug flows are reported for the first time. It was found that significant improvements in the heat transfer coefficient could be achieved by short slugs where the Nu number was found to be 610% higher than in single-phase flows. The study revealed new findings related to slug flow heat transfer in microchannels with constant wall heat flux.


Author(s):  
M DaqiqShirazi ◽  
R Torabi ◽  
A Riasi ◽  
SA Nourbakhsh

In this paper, the flow in the impeller sidewall gap of a low specific speed centrifugal pump is analyzed to study the effect of wear ring clearance and the resultant through-flow on flow field in this cavity and investigate the overall efficiency of the pump. Centrifugal pumps are commonly subject to a reduction in the flow rate and volumetric efficiency due to abrasive liquids or working conditions, since the wear rings are progressively worn, the internal leakage flow is increased. In the new operating point, the overall efficiency of the pump cannot be predicted simply by using the pump characteristic curves. The flow field is simulated with the use of computational fluid dynamics and the three-dimensional full Navier–Stokes equations are solved using CFX software. In order to verify the numerical simulations, static pressure field in volute casing and pump performance curves are compared with the experimental measurements. The results show that, for the pump with minimum wear ring clearance, the disk friction efficiency is the strongest factor that impairs the overall efficiency. Therefore, when the ring clearance is enlarged more than three times, although volumetric efficiency decreases effectively but the reduction in overall efficiency is remarkably smaller due to improvement in the disk friction losses.


Author(s):  
Anh Dinh Le ◽  
Biao Zhou

A single-phase, three-dimensional mathematical model has been constructed and implemented to simulate the fluid flow, heat transfer, species transport, electrochemical reaction, and current density distributions in a Proton Exchange Membrane Fuel Cell (PEMFC) stack with parallel-shaped channels. In this study, a complete PEMFC stack with 3 parallel single-cells including the membrane, gas diffusion layers (GDLs), catalyst layers, flow channels, and current collectors was taken into account. The reasonable numerical results show the detailed distributions of fluid flow and species concentrations in the channel and porous media, heat and current transports through the single cells in the stack. Furthermore, this successful modeling of a single-phase PEMFC stack would be a critical step to further develop a general two-phase PEMFC model that could investigate the water management and effects of liquid water on the performance of a fuel cell stack.


Sign in / Sign up

Export Citation Format

Share Document