Application of a Wall-Solar Chimney for Passive Ventilation of Dwellings

2015 ◽  
Vol 137 (6) ◽  
Author(s):  
David Park ◽  
Francine Battaglia

The solar chimney is a natural ventilation technique that has the potential to save energy use in buildings as well as maintain comfortable indoor quality. The objective of the current study was to examine the effects of the wall-solar chimney on airflow distribution and thermal conditions in a room. In the current work, computational fluid dynamics (CFD) was used to model a solar chimney. The solar chimney was modeled three-dimensionally for a more realistic simulation of fluid and thermal conditions. Experimental and numerical data from literature were used to validate the current model, and the results agreed very well. The current study showed that the flow in the solar chimney system can be either laminar or turbulent depending on the parameters of the system, and that the effect of the chimney inlet was more significant than that of the chimney width (air gap between the glass and absorber) on the flow regime. This study also developed a new characteristic Rayleigh number (Ra*) relating the chimney inlet and width, which showed good consistency with the prediction of the flow regime. The investigations of Ra* and the flow regime indicated that the flow becomes turbulent for Ra* ∼ 0.8 × 108. Finally, the potential improvements of the designs were discussed by observing the flow and thermal conditions of the room.

2015 ◽  
Author(s):  
David Park ◽  
Francine Battaglia

Energy consumption is an important issue and has become a great concern during last the few decades, where most energy consumption is utilized for conditioning buildings. The solar chimney is a natural ventilation technique that has the potential to save energy use in buildings as well as maintain comfortable indoor quality. The objective of the current study is to examine the effects of the wall-solar chimney on airflow distribution and thermal conditions in a room. In the current work, computational fluid dynamics was used to model a solar chimney. The time-dependent conservation equations for mass, momentum and energy were solved with the k-ε turbulence equations using ANSYS Fluent. Previous literature, that utilized numerical modeling to study the solar chimney for different dimensions of chimney geometry, only considered a two-dimensional solar chimney with one-directional heat transfer. In the current study, the solar chimney was modeled three-dimensionally for a more realistic simulation of actual flow and thermal condition of the room. Experimental and numerical data from literature were used to validate the current model, and the results agreed very well. The current study showed that the flow in the solar chimney system can be either laminar or turbulent depending on the parameters of the system, and that the effect of the chimney inlet is more significant than that of the air gap on the flow regime. This study also developed a new characteristic Rayleigh number Ra* relating the chimney inlet and the air gap, which showed good consistency with the prediction of the flow regime. The investigations on Ra* and the flow regime indicated that the flow becomes turbulent for Ra* ∼ 0.8 × 108. Lastly, the potential improvements of the designs were discussed by observing the flow and thermal condition of the room.


Author(s):  
David Park ◽  
Francine Battaglia

A solar chimney is a natural ventilation technique that has a potential to save energy consumption as well as to maintain the air quality in the building. However, studies of buildings are often challenging due to their large sizes. The objective of the current study was to determine relationships between small- and full-scale solar chimney system models. In the current work, computational fluid dynamics (CFD) was utilized to model different building sizes with a solar chimney system, where the computational model was validated with the experimental study of Mathur et al. The window, which controls entrainment of ambient air, was also studied to determine the effects of window position. Correlations for average velocity ratio and non-dimensional temperature were consistent regardless of window position. Buckingham pi theorem was employed to further non-dimensionalize the important variables. Regression analysis was conducted to develop a mathematical model to predict a relationship among all of the variables, where the model agreed well with simulation results with an error of 2.33%. The study demonstrated that the flow and thermal conditions in larger buildings can be predicted from the small-scale model.


2017 ◽  
Vol 139 (3) ◽  
Author(s):  
David Park ◽  
Francine Battaglia

A solar chimney is a natural ventilation technique that has potential to save energy consumption as well as to maintain the air quality in a building. However, studies of buildings are often challenging due to their large sizes. The objective of this study was to determine the relationships between small- and full-scale solar chimney system models. Computational fluid dynamics (CFD) was employed to model different building sizes with a wall-solar chimney utilizing a validated model. The window, which controls entrainment of ambient air for ventilation, was also studied to determine the effects of window position. A set of nondimensional parameters were identified to describe the important features of the chimney configuration, window configuration, temperature changes, and solar radiation. Regression analysis was employed to develop a mathematical model to predict velocity and air changes per hour, where the model agreed well with CFD results yielding a maximum relative error of 1.2% and with experiments for a maximum error of 3.1%. Additional wall-solar chimney data were tested using the mathematical model based on random conditions (e.g., geometry, solar intensity), and the overall relative error was less than 6%. The study demonstrated that the flow and thermal conditions in larger buildings can be predicted from the small-scale model, and that the newly developed mathematical equation can be used to predict ventilation conditions for a wall-solar chimney.


2014 ◽  
Vol 70 (7) ◽  
Author(s):  
Agung Murti Nugroho ◽  
Mohd Hamdan Ahmad

Natural ventilation has been promoted as passive indoor cooling technique in hot humid tropical region. However for a single sided window in a typical deep plan terrace house, the effect of natural ventilation is questionable. It is worst when coupled with the fact that available wind in Malang is almost static and unreliable. This paper presents alternative passive technologies integrated to existing terrace house in the city of Malang to achieve indoor cooling assisted by solar chimney and green vertical landscape. A field measurement was conducted using Onset Hobo Data Logger for a specific duration. The solar chimney is installed inside the house harnessing the thermal stack effect of hot air buoyancy that naturally forced the cyclic air movement letting hot air out and bringing in cooler air. The vertical green landscape installed just outside the front window provide shade and filter the incoming air providing cooler and cleaner air. The result showed that the average indoor temperature is within the acceptable comfort range for the whole day. This is considered a significant achievement where the use of solar chimney and green vertical landscape can improve indoor thermal condition thus provide alternative for natural cooling, reduce energy use and healthy environment.


2020 ◽  
Vol 14 (3) ◽  
pp. 7109-7124
Author(s):  
Nasreddine Sakhri ◽  
Younes Menni ◽  
Houari Ameur ◽  
Ali J. Chamkha ◽  
Noureddine Kaid ◽  
...  

The wind catcher or wind tower is a natural ventilation technique that has been employed in the Middle East region and still until nowadays. The present paper aims to study the effect of the one-sided position of a wind catcher device against the ventilated space or building geometry and its natural ventilation performance. Four models based on the traditional design of a one-sided wind catcher are studied and compared. The study is achieved under the climatic conditions of the South-west of Algeria (arid region). The obtained results showed that the front and Takhtabush’s models were able to create the maximum pressure difference (ΔP) between the windward and leeward of the tower-house system. Internal airflow velocities increased with the increase of wind speed in all studied models. For example, at Vwind = 2 m/s, the internal flow velocities were 1.7, 1.8, 1.3, and 2.5 m/s for model 1, 2, 3, and 4, respectively. However, at Vwind = 6 m/s, the internal flow velocities were 5.6, 5.5, 2.5, and 7 m/s for model 1, 2, 3, and 4, respectively. The higher internal airflow velocities are given by Takhtabush, traditional, front and middle tower models, respectively, with a reduction rate between the tower outlet and occupied space by 72, 42, 36, and 33% for the middle tower, Takhtabush, traditional tower, and the front model tower, respectively. This reduction is due to the due to internal flow resistance. The third part of the study investigates the effect of window (exist opening) position on the opposite wall. The upper, middle and lower window positions are studied and compared. The air stagnation or recirculation zone inside the ventilated space reduced from 55% with the lower window to 46% for the middle window and reached 35% for the upper window position. The Front and Takhtabush models for the one-sided wind catcher with an upper window position are highly recommended for the wind-driven natural ventilation in residential houses that are located in arid regions.


2018 ◽  
Vol 73 ◽  
pp. 01011
Author(s):  
Benediktus Yosef Arya Wastunimpuna ◽  
Wahyu Setia Budi ◽  
Erni Setyowati

The outside corridor of Dutch Colonial Building in Indonesia was made to make the temperature of the room more comfortable. Lawang Sewu Building in Semarang is one example of a building that has an outside corridor along the building and until now still use natural ventilation. This study focuses on finding out whether there is a difference on the thermal conditions of each room’s orientation, so after that we know the effect of orientation of the outdoor corridor to the temperature of the interior. In this study the experiment based on measurement using Heat Stress WBGT Meter for Wet Bulb Temperature, Dry Bulb Temperature, Relative Humidity, and KW0600653 Hot Wire Anemometer for the air movement. The data will be analysed using thermal standard theory to find out which point has the most comfortable thermal conditions.. At the end of this study will be found the effect of corridor’s orientation to thermal condition of the interior in Lawang Sewu Semarang.


Energies ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4388
Author(s):  
Esmail Mahmoudi Saber ◽  
Issa Chaer ◽  
Aaron Gillich ◽  
Bukola Grace Ekpeti

Natural ventilation is gaining more attention from architects and engineers as an alternative way of cooling and ventilating indoor spaces. Based on building types, it could save between 13 and 40% of the building cooling energy use. However, this needs to be implemented and operated with a well-designed and integrated control system to avoid triggering discomfort for occupants. This paper seeks to review, discuss, and contribute to existing knowledge on the application of control systems and optimisation theories of naturally ventilated buildings to produce the best performance. The study finally presents an outstanding theoretical context and practical implementation for researchers seeking to explore the use of intelligent controls for optimal output in the pursuit to help solve intricate control problems in the building industry and suggests advanced control systems such as fuzzy logic control as an effective control strategy for an integrated control of ventilation, heating and cooling systems.


Encyclopedia ◽  
2021 ◽  
Vol 1 (2) ◽  
pp. 409-422
Author(s):  
Haihua Zhang ◽  
Yao Tao ◽  
Long Shi

A solar chimney is a renewable energy system used to enhance the natural ventilation in a building based on solar and wind energy. It is one of the most representative solar-assisted passive ventilation systems attached to the building envelope. It performs exceptionally in enhancing natural ventilation and improving thermal comfort under certain climate conditions. The ventilation enhancement of solar chimneys has been widely studied numerically and experimentally. The assessment of solar chimney systems based on buoyancy ventilation relies heavily on the natural environment, experimental environment, and performance prediction methods, bringing great difficulties to quantitative analysis and parameterization research. With the increase in volume and complexity of modern building structures, current studies of solar chimneys have not yet obtained a unified design strategy and corresponding guidance. Meanwhile, combining a solar chimney with other passive ventilation systems has attracted much attention. The solar chimney-based integrated passive-assisted ventilation systems prolong the service life of an independent system and strengthen the ventilation ability for indoor cooling and heating. However, the progress is still slow regarding expanded applications and related research of solar chimneys in large volume and multi-layer buildings, and contradictory conclusions appear due to the inherent complexity of the system.


Author(s):  
B. P. Huynh

Natural-ventilation flow induced in a real-sized rectangular-box room fitted with a solar chimney on its roof is investigated numerically, using a commercial CFD (Computational Fluid Dynamics) software package. The chimney in turn is in the form of a parallel channel with one plate being subjected to uniform solar heat flux. Ventilation rate and air-flow pattern through the room are considered in terms of the heat flux for two different locations of the room’s inlet opening. Chien’s turbulence model of low-Reynolds-number K-ε is used in a Reynolds-Averaged Navier-Stokes (RANS) formulation. It is found that ventilation flow rate increases quickly with solar heat flux when this flux is low, but more gradually at higher flux. At low heat flux, ventilation rate is not significantly affected by location of the inlet opening to the room. On the other hand, at high heat flux, ventilation rate varies substantially with the opening’s location. Location of the inlet opening to the room also affects strongly the air-flow pattern. In any case, ample ventilation rate is readily induced by the chimney.