Investigation of Instability of a Pressure Compensated Vane Pump

Author(s):  
Ryan P. Jenkins ◽  
Monika Ivantysynova

Currently, fixed displacement pumps are typically used to provide the oil flow required for actuation of the clutches, cooling, and lubrication of automatic transmissions. This results in significant power losses as excess flow at higher engine speeds is throttled through orifices back to the tank. Therefore, the use of variable displacement pumps to supply the required oil flow can reduce the overall fuel consumption of the vehicle by eliminating this excess flow at high engine speeds. This paper presents the development and experimental validation setup of a model for a pressure compensated pivoting-cam-type variable displacement vane pump (VDVP) that is suitable for these applications. The pump operates at low system pressures (typically ∼5 bar with maximum 20 bar) with significant amounts of entrained air present in the working fluid (typically 3% by volume at the delivery) over a wide range of input speeds (700–6000 rpm). These conditions, along with a combination of a highly dynamic flow demand and dynamically changing pressure compensation setting, result in pump instabilities and loss of controllability. Previously, high leakage flow rates were introduced into the cam displacement control volume in an attempt to stabilize the pump with limited improvements. A high fidelity simulation model of the VDVP displacement chambers and cam displacement control volume pressure development was created in MATLAB/Simulink to accurately predict pump flow rates and cam dynamics in order to investigate these instabilities and methods for increasing the controllability of the VDVP. Additionally, the model provides a platform to assess the system sensitivity to changes in fluid/air mixture ratio, vane spacing, bias spring rate, and pump outlet pressure. A modified pump that was instrumented to measure the pressure gradients within each displacement chamber at the transitions between the suction and delivery ports under realistic operating conditions is presented. The modified pump was also instrumented with a linear variable displacement transducer (LVDT) to directly measure cam position during pump operation on an experimental test bed incorporating actual control valves found in an automatic transmission.

2012 ◽  
Vol 2012 ◽  
pp. 1-7 ◽  
Author(s):  
G. Leprince ◽  
C. Changenet ◽  
F. Ville ◽  
P. Velex

In order to investigate the oil projected by gears rotating in an oil bath, a test rig has been set up in which the quantity of lubricant splashed at several locations on the casing walls can be measured. An oblong-shaped window of variable size is connected to a tank for flow measurements, and the system can be placed at several locations. A series of formulae have been deduced using dimensional analysis which can predict the lubricant flow rate generated by one spur gear or one disk at various places on the casing. These results have been experimentally validated over a wide range of operating conditions (rotational speed, geometry, immersion depth, etc.).


Author(s):  
Mengtang M. Li ◽  
Ryan Foss ◽  
Kim A. Stelson ◽  
James D. Van de Ven ◽  
Eric J. Barth

High power density and good controllability are the most appealing characteristics that make hydraulic systems the best choice for many applications. Current state of the art hydraulic variable displacement pumps show high efficiency at high displacement while they have poor efficiencies at low displacement. This paper proposes a novel alternating flow (AF) variable displacement hydraulic pump to 1) eliminate metering losses by acting as a high-bandwidth pump for displacement control, 2) achieve high efficiency across a wide range of operating conditions and displacements, and 3) allow multiple units to be easily common-shaft mounted for a compact multi-actuator displacement control system from a single prime-mover. A dynamic model using first principles describes the cylinder pressure, flows between pairs of cylinders, and net inlet and outlet flows as a function of the pump’s phase shift angle. The model captures hydraulic check valve dynamics, the effective bulk modulus, leakage flows, and viscous friction. Piston kinematics and dynamics are discussed and energy loss models are presented and used to guide the design for a first prototype of the AF hydraulic pump. The paper presents simulation results from the model that offer an initial evaluation of this novel pump concept and potential applications.


Author(s):  
Mengtang Li ◽  
Ryan Foss ◽  
Kim A. Stelson ◽  
James D. Van de Ven ◽  
Eric J. Barth

Although current state of the art hydraulic variable displacement pumps are highly efficiently at high displacement, they have poor efficiency at low displacement. Besides, different operating speed and load pressure conditions also strongly affect their performance. This paper proposed a novel alternating flow (AF) hydraulic variable displacement pump to 1) eliminate throttling loss by acting as a high-bandwidth pump for displacement control, 2) achieve high efficiency across a wide range of operating conditions and displacements, and 3) allow multiple units to be easily common-shaft mounted for a compact multi-actuator displacement control system from a single prime-mover. This paper presents a simple closed form model for the AF hydraulic pump and shows the model validation with a first generation prototype. The simple closed form model captures input motor energy, output fluid energy and associated energy losses. With the closed form model validated, it can then be used to drive optimal design for future generation prototypes using a dimensionless group method.


1984 ◽  
Vol 19 (1) ◽  
pp. 87-100
Author(s):  
D. Prasad ◽  
J.G. Henry ◽  
P. Elefsiniotis

Abstract Laboratory studies were conducted to demonstrate the effectiveness of diffused aeration for the removal of ammonia from the effluent of an anaerobic filter treating leachate. The effects of pH, temperature and air flow on the process were studied. The coefficient of desorption of ammonia, KD for the anaerobic filter effluent (TKN 75 mg/L with NH3-N 88%) was determined at pH values of 9, 10 and 11, temperatures of 10, 15, 20, 30 and 35°C, and air flow rates of 50, 120, and 190 cm3/sec/L. Results indicated that nitrogen removal from the effluent of anaerobic filters by ammonia desorption was feasible. Removals exceeding 90% were obtained with 8 hours aeration at pH of 10, a temperature of 20°C, and an air flow rate of 190 cm3/sec/L. Ammonia desorption coefficients, KD, determined at other temperatures and air flow rates can be used to predict ammonia removals under a wide range of operating conditions.


Author(s):  
B. R. Nichols ◽  
R. L. Fittro ◽  
C. P. Goyne

Many high-speed, rotating machines across a wide range of industrial applications depend on fluid film bearings to provide both static support of the rotor and to introduce stabilizing damping forces into the system through a developed hydrodynamic film wedge. Reduced oil supply flow rate to the bearings can cause cavitation, or a lack of a fully developed film layer, at the leading edge of the bearing pads. Reducing oil flow has the well-documented effects of higher bearing operating temperatures and decreased power losses due to shear forces. While machine efficiency may be improved with reduced lubricant flow, little experimental data on its effects on system stability and performance can be found in the literature. This study looks at overall system performance of a test rig operating under reduced oil supply flow rates by observing steady-state bearing performance indicators and baseline vibrational response of the shaft. The test rig used in this study was designed to be dynamically similar to a high-speed industrial compressor. It consists of a 1.55 m long, flexible rotor supported by two tilting pad bearings with a nominal diameter of 70 mm and a span of 1.2 m. The first bending mode is located at approximately 5,000 rpm. The tiling-pad bearings consist of five pads in a vintage, flooded bearing housing with a length to diameter ratio of 0.75, preload of 0.3, and a load-between-pad configuration. Tests were conducted over a number of operating speeds, ranging from 8,000 to 12,000 rpm, and bearing loads, while systematically reducing the oil supply flow rates provided to the bearings under each condition. For nearly all operating conditions, a low amplitude, broadband subsynchronous vibration pattern was observed in the frequency domain from approximately 0–75 Hz. When the test rig was operated at running speeds above its first bending mode, a distinctive subsynchronous peak emerged from the broadband pattern at approximately half of the running speed and at the first bending mode of the shaft. This vibration signature is often considered a classic sign of rotordynamic instability attributed to oil whip and shaft whirl phenomena. For low and moderate load conditions, the amplitude of this 0.5x subsynchronous peak increased with decreasing oil supply flow rate at all operating speeds. Under the high load condition, the subsynchronous peak was largely attenuated. A discussion on the possible sources of this subsynchronous vibration including self-excited instability and pad flutter forced vibration is provided with supporting evidence from thermoelastohydrodynamic (TEHD) bearing modeling results. Implications of reduced oil supply flow rate on system stability and operational limits are also discussed.


Author(s):  
Massimo Rundo ◽  
Giorgio Altare

The paper describes the modelling and the experimental tests of a variable displacement vane pump for engine lubrication. The approach used for the simulation has involved 3D commercial tools for tuning a 0D customized model implemented in the LMS Amesim® environment. Different leakage paths are considered and the axial clearances are variable to take into account the deformation of the pump cover, calculated through a finite element analysis with ANSYS®. The vane tip clearances are calculated as function of the dynamic equilibrium equation of the vanes. The displacement control takes into account the internal forces on the stator due to the pressure in all variable chambers and to the contact force exerted by the vanes. The discharge coefficients in the resistive components have been tuned by means of a complete 3D transient model of the pump built with PumpLinx®. The tuned 0D model has been proved to be reliable for the determination of the steady-state flow-speed and flow-pressure curves, with a correct estimation of the internal leakages and of the pressure imposed by the displacement control. The pump has been also tested using a simplified circuit and a fair agreement has been found in the evaluation of the delivery pressure ripple.


2018 ◽  
Vol 140 (6) ◽  
Author(s):  
Massimo Rundo ◽  
Giorgio Altare

The paper describes the modeling and the experimental tests of a variable displacement vane pump for engine lubrication. The approach used for the simulation has involved three-dimensional (3D) commercial tools for tuning a zero-dimensional (0D) customized model implemented in the LMS Amesim® environment. Different leakage paths are considered and the axial clearances are variable to take into account the deformation of the pump cover, calculated through a finite element analysis with ANSYS. The vane tip clearances are calculated as function of the dynamic equilibrium equation of the vanes. The displacement control takes into account the internal forces on the stator due to the pressure in all variable chambers and to the contact force exerted by the vanes. The discharge coefficients in the resistive components have been tuned by means of a complete 3D transient model of the pump built with PumpLinx®. The tuned 0D model has been proved to be reliable for the determination of the steady-state flow-speed and flow-pressure curves, with a correct estimation of the internal leakages and of the pressure imposed by the displacement control. The pump has been also tested using a simplified circuit, and a fair agreement has been found in the evaluation of the delivery pressure ripple.


Author(s):  
Hélène Chaumat ◽  
Anne-Marie Billet ◽  
Henri Delmas

A detailed investigation of local hydrodynamics in a pilot plant bubble column has been performed using various techniques, exploring both axial and radial variations of the gas hold-up, bubble average diameter and frequency, surface area. A wide range of operating conditions has been explored up to large gas and liquid flow rates, with two sparger types. Two main complementary techniques were used: a quasi local measurement of gas hold-up via series of differential pressure sensors to get the axial variation and a double optic probe giving radial variations of gad hold-up, bubble average size and frequency and surface area.According to axial evolutions, three zones, where radial evolutions have been detailed, have been separated: at the bottom the gas injection zone, the large central region or column bulk and the disengagement zone at the column top. It was found that significant axial and radial variations of the two phase flow characteristics do exist even in the so called homogeneous regime. The normalized profiles of bubble frequency appear sparger and gas velocity independent contrary to bubble diameter, gas hold-up and interfacial area normalized profiles. In any case bubbles are larger in the sparger zone than elsewhere.The main result of this work is the very strong effect of liquid flow on bubble column hydrodynamics at low gas flow rate. First the flow regime map observed in batch mode is dramatically modified with a drastic reduction of the homogeneous regime region, up to a complete heterogeneous regime in the working conditions (uG> 0.02 m/s). On the contrary, liquid flow has limited effects at very high gas flow rates.A large data bank is provided to be used for example in detailed comparison with CFD calculations.


Energies ◽  
2021 ◽  
Vol 14 (20) ◽  
pp. 6543
Author(s):  
Mieczysław Dzierzgowski

Laboratory measurements and analyses conducted in a wide range of changes of water temperature and mass flow rate for different types of radiators allowed to provides limitations and assessment of the current radiators heat transfer model according to EN 442. The inaccuracy to determinate the radiator heat output according to EN 442, in case of low water mass flow rates may achieve up to 22.3% A revised New Extended Heat Transfer Model in Radiators NEHTMiRmd is general and suitable for different types of radiators both new radiators and radiators existing after a certain period of operation is presented. The NEHTMiRmd with very high accuracy describes the heat transfer processes not only in the nominal conditions—in which the radiators are designed, but what is particularly important also in operating conditions when the radiators water mass flow differ significantly from the nominal value and at the same time the supply temperature changes in the whole range radiators operating during the heating season. In order to prove that the presented new model NEHTMiRmd is general, the article presents numerous calculation examples for various types of radiators currently used. Achieved the high compatibility of the results of the simulation calculations with the measurement results for different types of radiators: iron elements (not ribbed), plate radiators (medium degree ribbed), convectors (high degree ribbed) in a very wide range of changes in the water mass flow rates and the supply temperature indicates that a verified NEHTMiRmd can also be used in designing and simulating calculations of the central heating installations, for the rational conversion of existing installations and district heating systems into low temperature energy efficient systems as well as to directly determine the actual energy efficiency, also to improve the indications of the heat cost allocators. In addition, it may form the basis for the future modification of the European Standards for radiator testing.


Author(s):  
M. Ellis ◽  
C. Kurwitz ◽  
F. Best

In the microgravity environment experienced by space vehicles, liquid and gas do not naturally separate as on Earth. This behavior presents a problem for two-phase space systems, such as environment conditioning, waste water processing, and power systems. Furthermore, with recent renewed interest in space nuclear power systems, a microgravity Rankine cycle is attractive for thermal to electric energy conversion and would require a phase separation device. Responding to this need, researchers have conceived various methods of producing phase separation in low gravity environments. These separator types have included wicking, elbow, hydrophobic/hydrophilic, vortex, rotary fan separators, and combinations thereof. Each class of separator achieved acceptable performance for particular applications and most performed in some capacity for the space program. However, increased integration of multiphase systems requires a separator design adaptable to a variety of system operating conditions. To this end, researchers at Texas A&M University (TAMU) have developed a Microgravity Vortex Separator (MVS) capable of handling both a wide range of inlet conditions as well as changes in these conditions with a single, passive design. Currently, rotary separators are recognized as the most versatile microgravity separation technology. However, compared with passive designs, rotary separators suffer from higher power consumption, more complicated mechanical design, and higher maintenance requirements than passive separators. Furthermore, research completed over the past decade has shown the MVS more resistant to inlet flow variations and versatile in application. Most investigations were conducted as part of system integration experiments including, among others, propellant transfer, waste water processing, and fuel cell systems. Testing involved determination of hydrodynamic conditions relating to vortex stability, inlet quality effects, accumulation volume potential, and dynamic volume monitoring. In most cases, a 1.2 liter separator was found to accommodate system flow conditions. This size produced reliable phase separation for liquid flow rates from 1.8 to 9.8 liters per minute, for gas flow rates of 0.5 to 180 standard liters per minute, over the full range of quality, and with fluid inventory changes up to 0.35 liters. Moreover, an acoustic sensor, integrated into the wall of the separation chamber, allows liquid film thickness monitoring with an accuracy of 0.1 inches. Currently, application of the MVS is being extended to cabin air dehumidification and a Rankine power cycle system. Both of these projects will allow further development of the TAMU separator.