High Performance Microvalve Array

Author(s):  
Dong Gun Lee ◽  
Daniel D. Shin ◽  
Gregory P. Carman

The fabrication, analysis, and testing of a large flow rate and high frequency microvalve array are presented in this paper. The array consists of 88-microvalves fabricated on a silicon-on-insulator (SOI) substrate. The SOI wafer simplifies the fabrication process and eliminates the need for multi-layer surface micromachining process and bulk wafer-bonding procedures. The analytical resonant frequency of the valve is up to 50 kHz and operates at high delta pressures (i.e. 0.14 MPa). The microvalves are fabricated with various flap widths ranging from 300 to 400 μm and flap thickness ranging from 10 to 13 μm. The results indicate that flap displacement and flow rate are strongly dependent on flap thicknesses and to a lesser degree on flap widths increases. The resonance frequency with valve flap thickness increases and width decreases. Comparison between predicted and measured flow rate shows good agreement. A flow rate up to 35 cc/sec was measured. A failure criterion is also presented using the fracture stress analysis and shows good agreement with experimental result.

2007 ◽  
Vol 134 (1) ◽  
pp. 257-263 ◽  
Author(s):  
Dong Gun Lee ◽  
Daniel D. Shin ◽  
Gregory P. Carman

2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Guangying Yu ◽  
Dan Fang

A simple and effective method was established and validated to determine 4-methylumbelliferone (4-MU) for screening the natural neuraminidase inhibitors (NAIs) from traditional medicines (TMs) by high performance liquid chromatography combined with fluorescence detection (HPLC-FLD). 4-MU and TMs compounds were separated on a Hedera TM ODS column (5 μm, 4.6 × 250 mm) using an isocratic elution of 55% methanol at 35°C. The flow rate was 1 mL min−1. The excitation and emission wavelength were performed at 320 nm and 480 nm. Some extracts of TMs and compounds were selected as examples to demonstrate the feasibility of the new HPLC-FLD method. It was found that the results of most compounds except for the auto fluorescence substances determined by HPLC-FLD were in good agreement with NA enzyme-based inhibitory assays. Comparing to traditional NA enzyme-based inhibitory assays, the HPLC-FLD method could prevent interference from fluorescence pigments of compounds. It was considered a simple, effective, and economical technique for the screening the natural neuraminidase inhibitors from traditional medicines.


Author(s):  
Syed N. R. Kazmi ◽  
Amal Z. Hajjaj ◽  
Pedro M. F. J. Costa ◽  
Mohammad I. Younis

We report an analytical and experimental study on the tunability of in-plane doubly-clamped nanomechanical arches under varied DC bias conditions at room temperature. For this purpose, silicon based shallow arches are fabricated using standard e-beam lithography and surface nanomachining of a highly conductive device layer on a silicon-on-insulator (SOI) wafer. The experimental results show good agreement with the analytical results with a maximum tunability of 108.14% for 180 nm thick arch with a transduction gap of 1 μm between the beam and the driving/sensing electrodes. The high tunability of shallow arches paves the ways for highly tunable band pass filtering applications in high frequency range.


Author(s):  
Peng Chen ◽  
Lei Jiang ◽  
Haixia Wang ◽  
Xiaorui Guo ◽  
Yilong Zhang ◽  
...  

Optical micro-angiography (OMAG) is a new method of detecting flow rate and widely used for in vivo imaging. Although OMAG can distinguish between flowing and stationary parts, it cannot obtain accurate flow rate information. This study proposed a range formula for OMAG and the ultrahigh-sensitivity OMAG (UHS-OMAG) method to quantify the measurement range of an entire system. The parameters of the angle between beam scanning and flow directions, the angular velocity of the galvanometer, and the offset of incident light were introduced, and a formula for calculating the range was derived. Experiments were conducted to measure fine and ultra-fine flow rates by using OMAG and UHS-OMAG methods. The minimum measured flow rate was approximately 30 μm/s, and the maximum measured flow rate was approximately 8 mm/s. Experimental results are in good agreement with the preset results.


2018 ◽  
Vol 15 (1) ◽  
pp. 32-38 ◽  
Author(s):  
Bürge Aşçı ◽  
Mesut Koç

Introduction:This paper presents the development and validation of a novel, fast, sensitive and accurate high performance liquid chromatography (HPLC) method for the simultaneous quantitative determination of dibucaine HCl, fluocortolone pivalate and fluocortolone caproate in pharmaceutical preparations.Experiment:Development of the chromatographic method was based on an experimental design approach. A five-level-three-factor central composite design requiring 20 experiments in this optimization study was performed in order to evaluate the effects of three independent variances including mobile phase ratio, flow rate and amount of acid in the mobile phase.Conclusion:The optimum composition for mobile phase was found as a methanol:water:acetic acid mixture at 71.6 : 26.4 : 2 (v/v/v) ratio and optimum separation was acquired by isocratic elution with a flow rate of 1.3 mL/min. The analytes were detected using a UV detector at 240 nm. The developed method was validated in terms of linearity, precision, accuracy, limit of detection/quantitation and solution stability and successfully applied to the determination of dibucaine HCl, fluocortolone pivalate and fluocortolone caproate in pharmaceutical topical formulations such as suppositories and ointments.


Micromachines ◽  
2021 ◽  
Vol 12 (2) ◽  
pp. 169
Author(s):  
Mengcheng Wang ◽  
Shenglin Ma ◽  
Yufeng Jin ◽  
Wei Wang ◽  
Jing Chen ◽  
...  

Through Silicon Via (TSV) technology is capable meeting effective, compact, high density, high integration, and high-performance requirements. In high-frequency applications, with the rapid development of 5G and millimeter-wave radar, the TSV interposer will become a competitive choice for radio frequency system-in-package (RF SIP) substrates. This paper presents a redundant TSV interconnect design for high resistivity Si interposers for millimeter-wave applications. To verify its feasibility, a set of test structures capable of working at millimeter waves are designed, which are composed of three pieces of CPW (coplanar waveguide) lines connected by single TSV, dual redundant TSV, and quad redundant TSV interconnects. First, HFSS software is used for modeling and simulation, then, a modified equivalent circuit model is established to analysis the effect of the redundant TSVs on the high-frequency transmission performance to solidify the HFSS based simulation. At the same time, a failure simulation was carried out and results prove that redundant TSV can still work normally at 44 GHz frequency when failure occurs. Using the developed TSV process, the sample is then fabricated and tested. Using L-2L de-embedding method to extract S-parameters of the TSV interconnection. The insertion loss of dual and quad redundant TSVs are 0.19 dB and 0.46 dB at 40 GHz, respectively.


Energies ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4566
Author(s):  
Minsoo Choi ◽  
Wongwan Jung ◽  
Sanghyuk Lee ◽  
Taehwan Joung ◽  
Daejun Chang

This study analyzes the thermodynamic, economic, and regulatory aspects of boil-off hydrogen (BOH) in liquid hydrogen (LH2) carriers that can be re-liquefied using a proposed re-liquefaction system or used as fuel in a fuel cell stack. Five LH2 carriers sailing between two designated ports are considered in a case study. The specific energy consumption of the proposed re-liquefaction system varies from 8.22 to 10.80 kWh/kg as the re-liquefaction-to-generation fraction (R/G fraction) is varied. The economic evaluation results show that the cost of re-liquefaction decreases as the re-liquefied flow rate increases and converges to 1.5 $/kg at an adequately large flow rate. Three energy efficient design index (EEDI) candidates are proposed to determine feasible R/G fractions: an EEDI equivalent to that of LNG carriers, an EEDI that considers the energy density of LH2, and no EEDI restrictions. The first EEDI candidate is so strict that the majority of the BOH should be used as fuel. In the case of the second EEDI candidate, the permittable R/G fraction is between 25% and 33%. If the EEDI is not applied for LH2 carriers, as in the third candidate, the specific life-cycle cost decreases to 67% compared with the first EEDI regulation.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Amol S. Jagdale ◽  
Nilesh S. Pendbhaje ◽  
Rupali V. Nirmal ◽  
Poonam M. Bachhav ◽  
Dayandeo B. Sumbre

Abstract Background A new, sensitive, suitable, clear, accurate, and robust reversed-phase high-performance liquid chromatography (RP-HPLC) method for the determination of brexpiprazole in bulk drug and tablet formulation was developed and validated in this research. Surface methodology was used to optimize the data, with a three-level Box-Behnken design. Methanol concentration in the mobile phase, flow rate, and pH were chosen as the three variables. The separation was performed using an HPLC method with a UV detector and Openlab EZchrom program, as well as a Water spherisorb C18 column (100 mm × 4.6; 5m). Acetonitrile was pumped at a flow rate of 1.0 mL/min with a 10 mM phosphate buffer balanced to a pH of 2.50.05 by diluted OPA (65:35% v/v) and detected at 216 nm. Result The developed RP-HPLC method yielded a suitable retention time for brexpiprazole of 4.22 min, which was optimized using the Design Expert-12 software. The linearity of the established method was verified with a correlation coefficient (r2) of 0.999 over the concentration range of 5.05–75.75 g/mL. For API and formulation, the percent assay was 99.46% and 100.91%, respectively. The percentage RSD for the method’s precision was found to be less than 2.0%. The percentage recoveries were discovered to be between 99.38 and 101.07%. 0.64 μg/mL and 1.95 μg/mL were found to be the LOD and LOQ, respectively. Conclusion The developed and validated RP-HPLC system takes less time and can be used in the industry for routine quality control/analysis of bulk drug and marketed brexpiprazole products. Graphical abstract


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Michal Sitina ◽  
Heiko Stark ◽  
Stefan Schuster

AbstractIn humans and higher animals, a trade-off between sufficiently high erythrocyte concentrations to bind oxygen and sufficiently low blood viscosity to allow rapid blood flow has been achieved during evolution. Optimal hematocrit theory has been successful in predicting hematocrit (HCT) values of about 0.3–0.5, in very good agreement with the normal values observed for humans and many animal species. However, according to those calculations, the optimal value should be independent of the mechanical load of the body. This is in contradiction to the exertional increase in HCT observed in some animals called natural blood dopers and to the illegal practice of blood boosting in high-performance sports. Here, we present a novel calculation to predict the optimal HCT value under the constraint of constant cardiac power and compare it to the optimal value obtained for constant driving pressure. We show that the optimal HCT under constant power ranges from 0.5 to 0.7, in agreement with observed values in natural blood dopers at exertion. We use this result to explain the tendency to better exertional performance at an increased HCT.


1977 ◽  
Vol 23 (12) ◽  
pp. 2288-2291 ◽  
Author(s):  
P H Culbreth ◽  
I W Duncan ◽  
C A Burtis

Abstract We used paired-ion high-performance liquid chromatography to determine the 4-nitrophenol content of 4-nitrophenyl phosphate, a substrate for alkaline phosphatase analysis. This was done on a reversed-phase column with a mobile phase of methanol/water, 45/55 by vol, containing 3 ml of tetrabutylammonium phosphate reagent per 200 ml of solvent. At a flow rate of 1 ml/min, 4-nitrophenol was eluted at 9 min and monitored at 404 nm; 4-nitrophenyl phosphate was eluted at 5 min and could be monitored at 311 nm. Samples of 4-nitrophenyl phosphate obtained from several sources contained 0.3 to 7.8 mole of 4-nitrophenol per mole of 4-nitrophenyl phosphate.


Sign in / Sign up

Export Citation Format

Share Document