Thermo-Fluid Mechanics of Fluid Injection and Refrigeration System Performance Improvement

Author(s):  
B. G. Shiva Prasad ◽  
Philip Moeller ◽  
John Sheridan

Injecting a fluid into a flowing stream is a common and powerful flow control technique to improve the flow process or performance of downstream components and machinery. This paper presents an application of such a technique to scroll compressors for improving the cooling capacity and efficiency of refrigerators and other heat pumps. It provides some insights into the physics of fluid injection and suggests methods for maximizing the benefits. Further, it discusses the need for CFD in system design and optimization and illustrates its application.

2014 ◽  
Vol 953-954 ◽  
pp. 119-122
Author(s):  
Yan Ling Liu ◽  
Xue Zeng Shi ◽  
Yuan Yu

s. In this paper, a new adsorption refrigeration system is designed and calculated. In this system, there are two beds, two condensers and two evaporators. The working principle is explained and specified in this paper. And mathematical models are also set up and through calculation, the system performance is analyzed and evaluated.Theory study results demonstrate that the new system nearly has the same cooling capacity as conventional system and this kind of system can be adopted in actual use.


1995 ◽  
Vol 117 (3) ◽  
pp. 181-186 ◽  
Author(s):  
W. Zheng ◽  
W. M. Worek ◽  
G. Nowakowski

The effect of two operating parameters, the regeneration temperature and the ambient temperature, on the performance of two-bed, closed-cycle solid-sorption heat pumps is investigated. The results show that increasing the regeneration temperature can improve both the COP and cooling capacity, and the effect on cooling capacity is more significant than the COP. Increasing the regeneration temperature from 180°C to 260°C, the cooling capacity increases by 50 percent and the COP improves 20 percent. When the ambient temperature drops, the system performance increases significantly. When the ambient temperature decreases by 10°C from the design point of 35°C, the COP and cooling capacity increases by 50 percent and 40 percent, respectively. Also, the bed cycling speed should be increased to achieve the optimum system performance when the regeneration temperature is higher or the ambient temperature becomes lower.


2020 ◽  
Vol 39 (3) ◽  
pp. 776-784
Author(s):  
T.S. Mogaji ◽  
A. Awolala ◽  
O.Z. Ayodeji ◽  
P.B. Mogaji ◽  
D.E. Philip

This study focused on development of an improved vapour compression refrigeration system (IVCR system). Dedicated mechanical subcooling cycle is employed in attaining the developed IVCR system. The system is composed of two cycles cascade refrigeration system working with R134a. It consists of a rectangular shape with total storage space of 0.582 m3, made of galvanized mild steel and internally insulated with 0.05 m polystyrene foam. Tests under a wide range operating temperature conditions were carried out on the developed IVCR system. Performance evaluation of the system was characterized in terms of cooling capacity and coefficient of performance (COP). Experimental results showed that the COP of the subcooled system improved better than that of the main system from 18.0% to about 33.5% over an evaporating temperature range of -10 to 30oC. It can be concluded that the use of dedicated sub cooling cycle in VCR system is more efficient and suitable for the betterment of thermal system performance. Keywords: Vapour compression Refrigeration system, Coefficient of performance, dedicated subcooled system, Condensation temperature, Evaporation temperature.


2017 ◽  
Vol 38 (1) ◽  
pp. 39-62 ◽  
Author(s):  
Ezzaalouni Yathreb Abdellaoui ◽  
Lakdar Kairouani Kairouani

AbstractIn this work, a new dual-evaporator CO2transcritical refrigeration cycle with two ejectors is proposed. In this new system, we proposed to recover the lost energy of condensation coming off the gas cooler and operate the refrigeration cycle ejector free and enhance the system performance and obtain dual-temperature refrigeration simultaneously. The effects of some key parameters on the thermodynamic performance of the modified cycle are theoretically investigated based on energetic and exergetic analysis. The simulation results for the modified cycle indicate more effective system performance improvement than the single ejector in the CO2vapor compression cycle using ejector as an expander ranging up to 46%. The exergetic analysis for this system is made. The performance characteristics of the proposed cycle show its promise in dual-evaporator refrigeration system.


2021 ◽  
Vol 13 (15) ◽  
pp. 8502
Author(s):  
Polinpapilinho F. Katina ◽  
James C. Pyne ◽  
Charles B. Keating ◽  
Dragan Komljenovic

Complex system governance (CSG) is an emerging field encompassing a framework for system performance improvement through the purposeful design, execution, and evolution of essential metasystem functions. The goal of this study was to understand how the domain of asset management (AsM) can leverage the capabilities of CSG. AsM emerged from engineering as a structured approach to organizing complex organizations to realize the value of assets while balancing performance, risks, costs, and other opportunities. However, there remains a scarcity of literature discussing the potential relationship between AsM and CSG. To initiate the closure of this gap, this research reviews the basics of AsM and the methods associated with realizing the value of assets. Then, the basics of CSG are provided along with how CSG might be leveraged to support AsM. We conclude the research with the implications for AsM and suggested future research.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Rajat Kumar Giri

Abstract In this paper, a hybrid-subcarrier-intensity-modulation (hybrid-SIM) technique for the performance improvement of free-space-optical (FSO) communication system has been proposed. Subsequently, for further error performance improvement, avalanche photodiode (APD) based receiver is used in the proposed system. The system performance is analyzed at various atmospheric turbulence levels over weak and strong turbulence channels. The bit error rate (BER) is theoretically derived using Gauss–Hermite approximation and Meijer-G function and it is simulated in the MATLAB environment. The simulation result shows that the BER performance of hybrid-SIM is better than BPSK-SIM technique irrespective of the channel types and also the significant BER performance improvement is observed by APD receiver.


2015 ◽  
Vol 19 (1) ◽  
pp. 109-118 ◽  
Author(s):  
Jahar Sarkar

The theoretical analyses of the double-tube gas cooler in transcritical carbon dioxide refrigeration cycle have been performed to study the performance improvement of gas cooler as well as CO2 cycle using Al2O3, TiO2, CuO and Cu nanofluids as coolants. Effects of various operating parameters (nanofluid inlet temperature and mass flow rate, CO2 pressure and particle volume fraction) are studied as well. Use of nanofluid as coolant in double-tube gas cooler of CO2 cycle improves the gas cooler effectiveness, cooling capacity and COP without penalty of pumping power. The CO2 cycle yields best performance using Al2O3-H2O as a coolant in double-tube gas cooler followed by TiO2-H2O, CuO-H2O and Cu-H2O. The maximum cooling COP improvement of transcritical CO2 cycle for Al2O3-H2O is 25.4%, whereas that for TiO2-H2O is 23.8%, for CuO-H2O is 20.2% and for Cu-H2O is 16.2% for the given ranges of study. Study shows that the nanofluid may effectively use as coolant in double-tube gas cooler to improve the performance of transcritical CO2 refrigeration cycle.


2011 ◽  
Vol 354-355 ◽  
pp. 811-818
Author(s):  
Tao He ◽  
Zhi Yuan Wang ◽  
Yu Qing Xue

The throttling valve used in the refrigeration system always causes energy loss. In this paper, an energy recovery device in the refrigeration system which was composed of an expander-auxiliary compressor unit to replace the throttling valve was investigated. On the basis of thermodynamic analysis, two typical arrangements which the auxiliary compressor was connected to the main compressor of the refrigeration system were compared and the system performance parameters were discussed. A prototype of an expander-auxiliary unit was manufactured to observe the expander performance using R410A as refrigerant. The results showed the reliability of the unit working in the two-phase flow condition with the rotation speed up to 21020 rpm. And the maximum increases in the cooling capacity by 3.9% and COP by 3.2% could be obtained under the testing condition.


Sign in / Sign up

Export Citation Format

Share Document