scholarly journals Laboratory and Clinical Evaluation of DNA Microarray for the Detection of Carbapenemase Genes in Gram-Negative Bacteria from Hospitalized Patients

2019 ◽  
Vol 2019 ◽  
pp. 1-13
Author(s):  
Yi Song ◽  
Fengna Dou ◽  
Sha He ◽  
Yu Zhou ◽  
Qiqi Liu

Background. The prevalence of a variety of carbapenemases in Gram-negative bacteria (GNB) has posed a global threat on clinical control and management. Monitoring and controlling the carbapenemase-producing GNB became imperative tasks for many healthcare centers. The aim of this study was to develop a high-throughput, specific, sensitive, and rapid DNA microarray-based method for the diagnosis, phenotypic confirmation, and molecular epidemiological study of carbapenemase genes. Methods. We targeted a panel of eight carbapenemase genes, including blaKPC, blaNDM-1, blaOXA-23, blaOXA-48, blaOXA-51, blaIMP, blaVIM, and blaDIM for detection. Ultrasensitive chemiluminescence (CL) detection method was developed and used to simultaneously detect eight carbapenemase genes, and plasmids were established as positive or limit of detection (LOD) reference materials. Antibiotic susceptibility was determined by disk diffusion according to Clinical and Laboratory Standards Institute (CLSI) guidelines in order to screen clinical isolates resistant to carbapenem antibiotics as well as Sanger sequencing which was used to confirm the reliability of the results presented by DNA microarray. Results. Eight carbapenemase genes could be detected with high sensitivity and specificity. The absolute LOD of this strategy to detect serially diluted plasmids of eight carbapenemase genes was 102- 103copies/μL. Then, 416 specimens collected from hospital were detected and the results showed 96.6% concordance between the phenotypic and microarray tests. Compared with Sanger sequencing, a specificity and sensitivity of 100% were recorded for blaNDM-1, blaIMP, blaVIM, and blaDIM genes. The specificity for blaKPC, blaOXA-23, blaOXA-48, and blaOXA-51 genes was 100% and the sensitivity was 98.5%, 97.6%, 95.7%, and 97.9%, respectively. The overall consistency rate between the sequencing and microarray is 97.8%. Conclusions. The proposed ultrasensitive CL imaging DNA hybridization has high specificity, sensitivity, and reproducibility and could detect and differentiate clinical specimens that carried various carbapenemase genes, suggesting that the method can conveniently be customized for high-throughput detection of the carbapenemase-producing GNB and can be easily adapted for various clinical applications.

2022 ◽  
Vol 12 ◽  
Author(s):  
Katharina Radakovics ◽  
Claire Battin ◽  
Judith Leitner ◽  
Sabine Geiselhart ◽  
Wolfgang Paster ◽  
...  

Toll-like receptors (TLRs) are primary pattern recognition receptors (PRRs), which recognize conserved microbial components. They play important roles in innate immunity but also in the initiation of adaptive immune responses. Impurities containing TLR ligands are a frequent problem in research but also for the production of therapeutics since TLR ligands can exert strong immunomodulatory properties even in minute amounts. Consequently, there is a need for sensitive tools to detect TLR ligands with high sensitivity and specificity. Here we describe the development of a platform based on a highly sensitive NF-κB::eGFP reporter Jurkat JE6-1 T cell line for the detection of TLR ligands. Ectopic expression of TLRs and their coreceptors and CRISPR/Cas9-mediated deletion of endogenously expressed TLRs was deployed to generate reporter cell lines selectively expressing functional human TLR2/1, TLR2/6, TLR4 or TLR5 complexes. Using well-defined agonists for the respective TLR complexes we could demonstrate high specificity and sensitivity of the individual reporter lines. The limit of detection for LPS was below 1 pg/mL and ligands for TLR2/1 (Pam3CSK4), TLR2/6 (Fsl-1) and TLR5 (flagellin) were detected at concentrations as low as 1.0 ng/mL, 0.2 ng/mL and 10 pg/mL, respectively. We showed that the JE6-1 TLR reporter cells have the utility to characterize different commercially available TLR ligands as well as more complex samples like bacterially expressed proteins or allergen extracts. Impurities in preparations of microbial compounds as well as the lack of specificity of detection systems can lead to erroneous results and currently there is no consensus regarding the involvement of TLRs in the recognition of several molecules with proposed immunostimulatory functions. This reporter system represents a highly suitable tool for the definition of structural requirements for agonists of distinct TLR complexes.


2017 ◽  
Author(s):  
Yanan Du ◽  
Xiao Zhao ◽  
Binan Zhao ◽  
Yan Xu ◽  
Wei Shi ◽  
...  

AbstractHere we report a novel microdroplet PCR method combined with fluorescence spectrophotometry (MPFS), which allows for qualitative, quantitative and high -throughput detection of multiple DNA targets. In this study, each pair of primers was labeled with a specific fluorophore. Through microdroplet PCR, a target DNA was amplified and labeled with the same fluorophore. After products purification, the DNA products tagged with different fluorophores could be analyzed qualitatively by the fluorescent intensity determination. The relative fluorensence unit was also measured to construct the standard curve and to achieve quantitative analysis. In a reaction, the co -amplified products with different fluorophores could be simultaneously analyzed to achieve high -throughput detection. We used four kinds of GM maize as a model to confirm this theory. The qualitative results revealed high specificity and sensitivity of 0.5% (w / w). The quantitative results revealed that the limit of detection was 103copies and with good repeatability. Moreover, reproducibility assay were further performed using four foodborne pathogenic bacteria. Consequently, the same qualitative, quantitative and high-throughput results were confirmed as the four GM maize.


Nanomaterials ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 1207
Author(s):  
Hong Jae Cheon ◽  
Quynh Huong Nguyen ◽  
Moon Il Kim

Inspired by the active site structure of natural horseradish peroxidase having iron as a pivotal element with coordinated histidine residues, we have developed histidine coated magnetic nanoparticles (His@MNPs) with relatively uniform and small sizes (less than 10 nm) through one-pot heat treatment. In comparison to pristine MNPs and other amino acid coated MNPs, His@MNPs exhibited a considerably enhanced peroxidase-imitating activity, approaching 10-fold higher in catalytic reactions. With the high activity, His@MNPs then were exploited to detect the important neurotransmitter acetylcholine. By coupling choline oxidase and acetylcholine esterase with His@MNPs as peroxidase mimics, target choline and acetylcholine were successfully detected via fluorescent mode with high specificity and sensitivity with the limits of detection down to 200 and 100 nM, respectively. The diagnostic capability of the method is demonstrated by analyzing acetylcholine in human blood serum. This study thus demonstrates the potential of utilizing His@MNPs as peroxidase-mimicking nanozymes for detecting important biological and clinical targets with high sensitivity and reliability.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yan Helen Yan ◽  
Sherry X. Chen ◽  
Lauren Y. Cheng ◽  
Alyssa Y. Rodriguez ◽  
Rui Tang ◽  
...  

AbstractWhole exome sequencing (WES) is used to identify mutations in a patient’s tumor DNA that are predictive of tumor behavior, including the likelihood of response or resistance to cancer therapy. WES has a mutation limit of detection (LoD) at variant allele frequencies (VAF) of 5%. Putative mutations called at ≤ 5% VAF are frequently due to sequencing errors, therefore reporting these subclonal mutations incurs risk of significant false positives. Here we performed ~ 1000 × WES on fresh-frozen and formalin-fixed paraffin-embedded (FFPE) tissue biopsy samples from a non-small cell lung cancer patient, and identified 226 putative mutations at between 0.5 and 5% VAF. Each variant was then tested using NuProbe NGSure, to confirm the original WES calls. NGSure utilizes Blocker Displacement Amplification to first enrich the allelic fraction of the mutation and then uses Sanger sequencing to determine mutation identity. Results showed that 52% of the 226 (117) putative variants were disconfirmed, among which 2% (5) putative variants were found to be misidentified in WES. In the 66 cancer-related variants, the disconfirmed rate was 82% (54/66). This data demonstrates Blocker Displacement Amplification allelic enrichment coupled with Sanger sequencing can be used to confirm putative mutations ≤ 5% VAF. By implementing this method, next-generation sequencing can reliably report low-level variants at a high sensitivity, without the cost of high sequencing depth.


2016 ◽  
Vol 60 (10) ◽  
pp. 5995-6002 ◽  
Author(s):  
Kristin R. Baker ◽  
Bimal Jana ◽  
Henrik Franzyk ◽  
Luca Guardabassi

ABSTRACTThe envelope of Gram-negative bacteria constitutes an impenetrable barrier to numerous classes of antimicrobials. This intrinsic resistance, coupled with acquired multidrug resistance, has drastically limited the treatment options against Gram-negative pathogens. The aim of the present study was to develop and validate an assay for identifying compounds that increase envelope permeability, thereby conferring antimicrobial susceptibility by weakening of the cell envelope barrier in Gram-negative bacteria. A high-throughput whole-cell screening platform was developed to measureEscherichia colienvelope permeability to a β-galactosidase chromogenic substrate. The signal produced by cytoplasmic β-galactosidase-dependent cleavage of the chromogenic substrate was used to determine the degree of envelope permeabilization. The assay was optimized by using known envelope-permeabilizing compounds andE. coligene deletion mutants with impaired envelope integrity. As a proof of concept, a compound library comprising 36 peptides and 45 peptidomimetics was screened, leading to identification of two peptides that substantially increased envelope permeability. Compound 79 reduced significantly (from 8- to 125-fold) the MICs of erythromycin, fusidic acid, novobiocin and rifampin and displayed synergy (fractional inhibitory concentration index, <0.2) with these antibiotics by checkerboard assays in two genetically distinctE. colistrains, including the high-risk multidrug-resistant, CTX-M-15-producing sequence type 131 clone. Notably, in the presence of 0.25 μM of this peptide, both strains were susceptible to rifampin according to the resistance breakpoints (R> 0.5 μg/ml) for Gram-positive bacterial pathogens. The high-throughput screening platform developed in this study can be applied to accelerate the discovery of antimicrobial helper drug candidates and targets that enhance the delivery of existing antibiotics by impairing envelope integrity in Gram-negative bacteria.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Lauren Y. Cheng ◽  
Lauren E. Haydu ◽  
Ping Song ◽  
Jianyi Nie ◽  
Michael T. Tetzlaff ◽  
...  

AbstractMutations in the BRAF gene at or near the p. V600 locus are informative for therapy selection, but current methods for analyzing FFPE tissue DNA generally have a limit of detection of 5% variant allele frequency (VAF), or are limited to the single variant (V600E). These can result in false negatives for samples with low VAFs due to low tumor content or subclonal heterogeneity, or harbor non-V600 mutations. Here, we show that Sanger sequencing using the NuProbe VarTrace BRAF assay, based on the Blocker Displacement Amplification (BDA) technology, is capable of detecting BRAF V600 mutations down to 0.20% VAF from FFPE lymph node tissue samples. Comparison experiments on adjacent tissue sections using BDA Sanger, immunohistochemistry (IHC), digital droplet PCR (ddPCR), and NGS showed 100% concordance among all 4 methods for samples with BRAF mutations at ≥ 1% VAF, though ddPCR did not distinguish the V600K mutation from the V600E mutation. BDA Sanger, ddPCR, and NGS (with orthogonal confirmation) were also pairwise concordant for lower VAF mutations down to 0.26% VAF, but IHC produced a false negative. Thus, we have shown that Sanger sequencing can be effective for rapid detection and quantitation of multiple low VAF BRAF mutations from FFPE samples. BDA Sanger method also enabled detection and quantitation of less frequent, potentially actionable non-V600 mutations as demonstrated by synthetic samples.


2021 ◽  
Vol 11 (11) ◽  
pp. 1774-1780
Author(s):  
Shanji Fan ◽  
Hong Huang ◽  
Hong Chen ◽  
Jiachi Xu ◽  
Zecheng Hu ◽  
...  

A CdS nanocrystal enhanced TiO2 nanotubes (CdS@TiO2 NATs) photoelectrode was prepared via successive ionic layer adsorption and reaction (SILAR) of CdS on the surface of TiO2 NATs. A HS-aptamer owing a specific binding toward cytochrome c was modified onto the CdS@TiO2 NATs, which resulting a decrease in the photoelectrical current intensity. Cytochrome c is therefore quantified based on the decrease in photoelectrical current. High specificity and high sensitivity were obtained with a linear range from 3 pM to 80 nM, and a limit of detection of 2.53 pM.


2021 ◽  
Author(s):  
Yan Chen ◽  
Nurgul Kaplan Lease ◽  
Jennifer Gin ◽  
Tad Ogorzalek ◽  
Paul D. Adams ◽  
...  

Manual proteomic sample preparation methods limit sample throughput and often lead to poor data quality when thousands of samples must be analyzed. Automated workflows are increasingly used to overcome these issues for some (or even all) of the sample preparation steps. Here, we detail three optimised step-by-step protocols to: (A) lyse Gram-negative bacteria and fungal cells; (B) quantify the amount of protein extracted; and (C) normalize the amount of protein and set up tryptic digestion. These protocols have been developed to facilitate rapid, low variance sample preparation of hundreds of samples, be easily implemented on widely-available Beckman-Coulter Biomek automated liquid handlers, and allow flexibility for future protocol development. By using this workflow 50 micrograms of peptides for 96 samples can be prepared for tryptic digestion in under an hour. We validate these protocols by analyzing 47 E. coli and R. toruloides samples and show that this modular workflow provides robust, reproducible proteomic samples for high-throughput applications. The expected results from these protocols are 94 peptide samples from Gram-negative bacterial and fungal cells prepared for bottom-up quantitative proteomic analysis without the need for desalting column cleanup and with peptide variance (CVs) below 15%.


2021 ◽  
Vol 8 ◽  
Author(s):  
Alfredo Garcia-Venzor ◽  
Bertha Rueda-Zarazua ◽  
Eduardo Marquez-Garcia ◽  
Vilma Maldonado ◽  
Angelica Moncada-Morales ◽  
...  

As to date, more than 49 million confirmed cases of Coronavirus Disease 19 (COVID-19) have been reported worldwide. Current diagnostic protocols use qRT-PCR for viral RNA detection, which is expensive and requires sophisticated equipment, trained personnel and previous RNA extraction. For this reason, we need a faster, direct and more versatile detection method for better epidemiological management of the COVID-19 outbreak. In this work, we propose a direct method without RNA extraction, based on the Loop-mediated isothermal amplification (LAMP) and Clustered Regularly Interspaced Short Palindromic Repeats-CRISPR associated protein (CRISPR-Cas12) technique that allows the fast detection of SARS-CoV-2 from patient samples with high sensitivity and specificity. We obtained a limit of detection of 16 copies/μL with high specificity and at an affordable cost. The diagnostic test readout can be done with a real-time PCR thermocycler or with the naked eye in a blue-light transilluminator. Our method has been evaluated on a small set of clinical samples with promising results.


2016 ◽  
Vol 10 (1) ◽  
pp. 176-182 ◽  
Author(s):  
Reza Ranjbar ◽  
Payam Behzadi ◽  
Caterina Mammina

Background:Francisella tularensis(F. tularensis) is the etiological microorganism for tularemia. There are different forms of tularemia such as respiratory tularemia. Respiratory tularemia is the most severe form of tularemia with a high rate of mortality; if not treated. Therefore, traditional microbiological tools and Polymerase Chain Reaction (PCR) are not useful for a rapid, reliable, accurate, sensitive and specific diagnosis. But, DNA microarray technology does. DNA microarray technology needs to appropriate microarray probe designing.Objective:The main goal of this original article was to design suitable long oligo microarray probes for detection and identification ofF. tularensis.Method:For performing this research, the complete genomes ofF. tularensissubsp.tularensisFSC198,F. tularensissubsp.holarcticaLVS,F. tularensissubsp.mediasiatica,F. tularensissubsp.novicida(F. novicidaU112), andF. philomiragiasubsp.philomiragiaATCC 25017 were studiedviaNCBI BLAST tool, GView and PanSeq Servers and finally the microarray probes were produced and processedviaAlleleID 7.7 software and Oligoanalyzer tool, respectively.Results:In thisin silicoinvestigation, a number of long oligo microarray probes were designed for detecting and identifyingF. tularensis. Among these probes, 15 probes were recognized as the best candidates for microarray chip designing.Conclusion:Calibrated microarray probes reduce the biasis of DNA microarray technology as an advanced, rapid, accurate and cost-effective molecular diagnostic tool with high specificity and sensitivity. Professional microarray probe designing provides us with much more facility and flexibility regarding preparation of a microarray diagnostic chip.


Sign in / Sign up