scholarly journals Psychometric Properties of the MyotonPRO in Dementia Patients with Paratonia

Gerontology ◽  
2017 ◽  
Vol 64 (4) ◽  
pp. 401-412 ◽  
Author(s):  
Hans Drenth ◽  
Sytse U. Zuidema ◽  
Wim P. Krijnen ◽  
Ivan Bautmans ◽  
Cees van der Schans ◽  
...  

Background: Paratonia is a distinctive form of hypertonia, causing loss of functional mobility in early stages of dementia to severe high muscle tone and pain in the late stages. For assessing and evaluating therapeutic interventions, objective instruments are required. Objective: Determine the psychometric properties of the MyotonPRO, a portable device that objectively measures muscle properties, in dementia patients with paratonia. Methods: Muscle properties were assessed with the MyotonPRO by 2 assessors within one session and repeated by the main researcher after 30 min and again after 6 months. Receiver operating characteristic curves were constructed for all MyotonPRO outcomes to discriminate between participants with (n = 70) and without paratonia (n = 82). In the participants with paratonia, correlation coefficients were established between the MyotonPRO outcomes and the Modified Ashworth Scale for paratonia (MAS-P) and muscle palpation. In participants with paratonia, reliability (intraclass correlation coefficient) and agreement values (standard error of measurement and minimal detectable change) were established. Longitudinal outcome from participants with paratonia throughout the study (n = 48) was used to establish the sensitivity for change (correlation coefficient) and responsiveness (minimal clinical important difference). Results: Included were 152 participants with dementia (mean [standard deviation] age of 83.5 [98.2]). The area under the curve ranged from 0.60 to 0.67 indicating the MyotonPRO is able to differentiate between participants with and without paratonia. The MyotonPRO explained 10-18% of the MAS-P score and 8-14% of the palpation score. Interclass correlation coefficients for interrater reliability ranged from 0.57 to 0.75 and from 0.54 to 0.71 for intrarater. The best agreement values were found for tone, elasticity, and stiffness. The change between baseline and 6 months in the MyotonPRO outcomes explained 8-13% of the change in the MAS-P scores. The minimal clinically important difference values were all smaller than the measurement error. Conclusion: The MyotonPRO is potentially applicable for cross-sectional studies between groups of paratonia patients and appears less suitable to measure intraindividual changes in paratonia. Because of the inherent variability in movement resistance in paratonia, the outcomes from the MyotonPRO should be interpreted with care; therefore, future research should focus on additional guidelines to increase the clinical interpretation and improving reproducibility.

2015 ◽  
Vol 31 (3) ◽  
pp. 507-515 ◽  
Author(s):  
Laércio Lima Luz ◽  
Lívia Maria Santiago ◽  
João Francisco Santos da Silva ◽  
Inês Echenique Mattos

This study aims to assess the psychometric properties of the Brazilian version of the Vulnerable Elders Survey-13 (VES-13). Interviews were carried out with individuals aged 60 years and over receiving care at an ambulatory cancer centre. Test-retest reliability was assessed using the Spearman correlation coefficient, intraclass correlation coefficients and Cohen's kappa coefficient. Construct validity was assessed by testing convergent and discriminant validity using principal component analysis and Varimax rotation. The Spearman correlation coefficient value of the comparison between test and retest scores was 0.98 (p < 0.001). All intraclass correlation coefficient values were higher than 0.60 and kappa coefficients varied between 0.33 and 0.94. Three identified factors explained 72.6% of overall sample variance. VES-13 presented good convergent validity and reasonable discriminant validity. The psychometric properties of the adapted version of the VES-13 are consistent and adequate for use with the Brazilian population.


Nutrients ◽  
2021 ◽  
Vol 13 (4) ◽  
pp. 1163
Author(s):  
Suzana Shahar ◽  
Mohd Razif Shahril ◽  
Noraidatulakma Abdullah ◽  
Boekhtiar Borhanuddin ◽  
Mohd Arman Kamaruddin ◽  
...  

Measuring dietary intakes in a multi-ethnic and multicultural setting, such as Malaysia, remains a challenge due to its diversity. This study aims to develop and evaluate the relative validity of an interviewer-administered food frequency questionnaire (FFQ) in assessing the habitual dietary exposure of The Malaysian Cohort (TMC) participants. We developed a nutrient database (with 203 items) based on various food consumption tables, and 803 participants were involved in this study. The output of the FFQ was then validated against three-day 24-h dietary recalls (n = 64). We assessed the relative validity and its agreement using various methods, such as Spearman’s correlation, weighed Kappa, intraclass correlation coefficient (ICC), and Bland–Altman analysis. Spearman’s correlation coefficient ranged from 0.24 (vitamin C) to 0.46 (carbohydrate), and almost all nutrients had correlation coefficients above 0.3, except for vitamin C and sodium. Intraclass correlation coefficients ranged from −0.01 (calcium) to 0.59 (carbohydrates), and weighted Kappa exceeded 0.4 for 50% of nutrients. In short, TMC’s FFQ appears to have good relative validity for the assessment of nutrient intake among its participants, as compared to the three-day 24-h dietary recalls. However, estimates for iron, vitamin A, and vitamin C should be interpreted with caution.


2021 ◽  
Vol 80 (Suppl 1) ◽  
pp. 1423.2-1424
Author(s):  
J. A. Mendonça ◽  
I. Siste de Almeida Aoki ◽  
C. C. Cavuto ◽  
V. A. Leandro-Merhi ◽  
J. L. B. D. Aquino

Background:The gray scale (GS) in high resolution ultrasound is already well validated for use in rheumatological diseases, but the color map or the histogram, can be considered a new proposal, to better define and complement the echotextural damages detection1.Objectives:To calculate the lesions area measures reproducibility index in arthropathies, between 3 blind evaluators and correlate these measures using the GS and the histogram.Methods:Observational and retrospective study approved by the ethics committee of the Pontifical Catholic University of Campinas, with the opinion number: 1.526.307. A total of 29 patients have been assessed (31% males and 69% females) on period 2014 to 2019 in Rheumatology service. A MyLab 50 -Esaote equipment was used with frequency transducer that ranged between 6.0 and 18.0 MHz, 10 different area measures were performed from each recorded images previously, by the GS and the histogram. Statistical analysis: Spearman’s correlation coefficients, Lin’s concordance coefficient (CCC) and the intraclass correlation coefficient (ICC) and their respective 95% confidence intervals, with the SPSS software package for Windows v. 17.0 (SPSS Inc., Chicago, IL, USA).Results:Average age 43.5 ± 21.5 years of age; with disease duration that varied between ≤ 1 month (48.3%) and ≥36 months (24.1%); with the following diseases: juvenile idiopathic arthritis (17.24%); osteoarthritis (13.79%); psoriatic arthritis (13.79%); undifferentiated spondyloarthritis (3.44%); gout (20.68%); rheumatoid arthritis (27.58%) and reactive arthritis (3.44%). A total of 840 measures of exudative (27.58%), proliferative (27.58%) and snowstorm appearance (6.89%) synovitis were performed; femoral-condyle cartilage (3.44%); synovial cyst (3.44%); paratendinitis (6.89%); calcification (3.44%); nail enthesitis (3.44%); tenosynovitis (6.89%) and tophi (10.34%) (Figure 1). The concordance correlation coefficient showed values closer to 1; p <0.001, the intraclass correlation coefficients with excellent reproducibility (ICC ≥ 0.75); p <0.001, always in relation to the three evaluators (Table 1) and the Spearman correlation between the GS and the histogram ranged from rs = 0.665 to rs = 1,000; p <0.001.Conclusion:The histogram can be considered an image method to better identify echotextural damages.References:[1]Mendonça J, Provenza J, Guissa V, et al AB1059 2D Histogram Ultrasound and 3D Ultrasound Correlation in Rheumatic Diseases Annals of the Rheumatic Diseases 2015; 74:1253-1254.Table 1.Concordance Correlation Coefficient (CCC) and Intraclass Correlation Coefficient (ICC):EvaluatorsGS - CCC(IC 95%)p-valorHistogram (IC 95%)p-valor1 e 20,998(0,994-0,999)<0,0010,999(0,995-1,000)<0,0011 e 30,998(0,995-0,999)<0,0010,999(0,995-1,000)<0,0012 e 30,992(0,980-0,997)<0,010,996(0,979-0,999)<0,01Standard by US 2DICCp-valorGS0,997(0,992-0,999)<0,001Histogram0,998(0,992-0,999)<0,001Legends: Gray Scale (GS).Figure 1.Patient with gout: A and B: Tophi area measures (star) in right metatarsos and efusion (arrow) by GS (45 mm2) and histogram (39 mm2), respectively.Disclosure of Interests:José Alexandre Mendonça Speakers bureau: Novartis, Janssen, Bristol, UCB, Isabella Siste de Almeida Aoki: None declared, Caique Chagas Cavuto: None declared, Vânia Aparecida Leandro-Merhi: None declared, José Luis Braga de Aquino: None declared


2021 ◽  
Vol 8 ◽  
Author(s):  
Yunru Liao ◽  
Zhenlan Yang ◽  
Zijing Li ◽  
Rui Zeng ◽  
Jing Wang ◽  
...  

Purpose: Purpose of this study is to evaluate the measuring consistency of central refraction between multispectral refraction topography (MRT) and autorefractometry.Methods: This was a descriptive cross-sectional study including subjects in Sun Yat-sen Memorial Hospital from September 1, 2020, to December 31, 2020, ages 20 to 35 years with a best corrected visual acuity of 20/20 or better. All patients underwent cycloplegia, and the refractive status was estimated with autorefractometer, experienced optometrist and MRT. We analyzed the central refraction of the autorefractometer and MRT. The repeatability and reproducibility of values measured using both devices were evaluated using intraclass correlation coefficients (ICCs).Results: A total of 145 subjects ages 20 to 35 (290 eyes) were enrolled. The mean central refraction of the autorefractometer was −4.69 ± 2.64 diopters (D) (range −9.50 to +4.75 D), while the mean central refraction of MRT was −4.49 ± 2.61 diopters (D) (range −8.79 to +5.02 D). Pearson correlation analysis revealed a high correlation between the two devices. The intraclass correlation coefficient (ICC) also showed high agreement. The intrarater and interrater ICC values of central refraction were more than 0.90 in both devices and conditions. At the same time, the mean central refraction of experienced optometrist was −4.74 ± 2.66 diopters (D) (range −9.50 to +4.75D). The intra-class correlation coefficient of central refraction measured by MRT and subjective refraction was 0.939.Conclusions: Results revealed that autorefractometry, experienced optometrist and MRT show high agreement in measuring central refraction. MRT could provide a potential objective method to assess peripheral refraction.


Author(s):  
Richard R. Suminski ◽  
Gregory M. Dominick ◽  
Matthew Saponaro

Evidence suggests that video captured with a wearable video device (WVD) may augment or supplant traditional methods for assessing park use. Unmanned aerial systems (UASs) are used to assess human activity, but research employing them for park assessments is sparse. Therefore, this study compared park user counts between a WVD and UAS. A diverse set of 33 amenities (e.g., playground) in three parks were videoed simultaneously by one researcher wearing a WVD and another operating the UAS. Assessments were done at 12 p.m. and 7 p.m. on weekends, with one park evaluated on two occasions 7 days apart. Two investigators independently reviewed videos and reached consensus on the counts of individuals at each amenity. Intraclass correlation coefficients (ICCs) were used to determine intra- and interrater reliabilities. A total of 404 (M = 4.7; SD = 9.6) and 389 (M = 4.5; SD = 9.0) individuals were counted in the UAS and WVD videos, respectively. Absolute agreement was 86% (74/86) and 100% when no individuals were using the amenity. Whether using all 86 videos or only videos having people (48 videos), ICCs indicated excellent reliability (ICC = .99; p < .001). The totals seen for the repeated measures were UAS = 146 and WVD = 136 for Day 1 and UAS = 169 and WVD = 161 for Day 2. Intrarater reliability was excellent for the UAS (ICC = .92; p < .001) and good for the WVD (ICC = .89; p < .001). Disagreement was mainly due to obstructions—people behind or under structures. This study provides support for the use of UASs for counting park users and future research examining the potential benefits of video analysis for assessing park use.


1999 ◽  
Vol 8 (4) ◽  
pp. 254-261 ◽  
Author(s):  
J Powers ◽  
SJ Bennett

BACKGROUND: Dyspnea, or difficult breathing, is common in patients receiving mechanical ventilation; however, dyspnea is not routinely or systematically measured. OBJECTIVE: The primary purpose of this methodological study was to evaluate the test-retest reliability of 5 dyspnea rating scales and the criterion validity of 4 dyspnea rating scales in patients receiving mechanical ventilation. The secondary purpose was to examine the correlations between each of these 5 rating scales and physiological measures of respiratory function. METHODS: The convenience sample consisted of 28 patients on mechanical ventilation during their hospitalization in the intensive care units of a large, inner-city hospital. Patients rated their dyspnea twice at 30-minute intervals on the visual analogue scale, the vertical analogue dyspnea scale, the modified Borg scale, the numerical scale, and the faces scale. Test-retest reliability was computed by using the intraclass correlation coefficient. Criterion validity was evaluated by using the Spearman rank-order correlation coefficient. RESULTS: The 5 rating scales had acceptable test-retest reliabilities, with intraclass correlation coefficients ranging from 0.81 to 0.97. Criterion validity of the 4 scales also was acceptable, with Spearman rank-order correlation coefficients from 0.76 to 0.96. The rating scales were not correlated with most of the physiological variables. At least half of the patients reported moderate to severe dyspnea. CONCLUSION: The scales showed acceptable reliability and validity, and they will be useful in quantifying dyspnea experienced by patients receiving mechanical ventilation. Further work is needed to evaluate the extent and the severity of dyspnea in such patients in order to evaluate the effectiveness of interventions.


2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Alexander Tingulstad ◽  
Rikke Munk ◽  
Margreth Grotle ◽  
Ørjan Vigdal ◽  
Kjersti Storheim ◽  
...  

Abstract Background The Back Beliefs Questionnaire (BBQ) is a 14-item patient-reported questionnaire that measures attitudes and beliefs about the consequences of back pain. The BBQ has recently been translated into Norwegian, but its psychometric properties have not yet been tested. The aim of this study is to evaluate the reliability and construct validity of the BBQ when used on elderly patients with back pain. Method A prospective cohort study with a test-retest design among 116 elderly patients (> 55 years of age) seeking primary care for a new episode of back pain. Test-retest, standard error of measurement (SEM), minimal detectable change (MDC), internal consistency and construct validity by a priori hypotheses (Spearman’s- and Pearson correlation coefficient) were tested. Results A total of 116 patients, mean age (SD) 67.7 (8.3), were included and 63 patients responded to the test-retest assessment. The mean (SD) BBQ sum scores (range 9–45) were 29.8 (7.0) and 29.2 (6.7) for the test and retest respectively. The test-retest was acceptable with an intraclass correlation coefficient of 0.71 (95% CI, 0.54–0.82), SEM was 3.8 and MDC 10.5. Internal consistency with Cronbach’s alpha was good (0.82) and acceptable construct validity was supported by the confirmation of 75% of the a priori hypotheses. Conclusion The Norwegian version of the BBQ demonstrated acceptable test-retest reliability and good construct validity and can be used to assess pessimistic beliefs in elderly patients with back pain.


2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Hannah M. L. Young ◽  
Mark W. Orme ◽  
Yan Song ◽  
Maurice Dungey ◽  
James O. Burton ◽  
...  

Abstract Background Physical activity (PA) is exceptionally low amongst the haemodialysis (HD) population, and physical inactivity is a powerful predictor of mortality, making it a prime focus for intervention. Objective measurement of PA using accelerometers is increasing, but standard reporting guidelines essential to effectively evaluate, compare and synthesise the effects of PA interventions are lacking. This study aims to (i) determine the measurement and processing guidance required to ensure representative PA data amongst a diverse HD population, and; (ii) to assess adherence to PA monitor wear amongst HD patients. Methods Clinically stable HD patients from the UK and China wore a SenseWear Armband accelerometer for 7 days. Step count between days (HD, Weekday, Weekend) were compared using repeated measures ANCOVA. Intraclass correlation coefficients (ICCs) determined reliability (≥0.80 acceptable). Spearman-Brown prophecy formula, in conjunction with a priori ≥  80% sample size retention, identified the minimum number of days required for representative PA data. Results Seventy-seven patients (64% men, mean ± SD age 56 ± 14 years, median (interquartile range) time on HD 40 (19–72) months, 40% Chinese, 60% British) participated. Participants took fewer steps on HD days compared with non-HD weekdays and weekend days (3402 [95% CI 2665–4140], 4914 [95% CI 3940–5887], 4633 [95% CI 3558–5707] steps/day, respectively, p < 0.001). PA on HD days were less variable than non-HD days, (ICC 0.723–0.839 versus 0.559–0.611) with ≥ 1 HD day and ≥  3 non-HD days required to provide representative data. Using these criteria, the most stringent wear-time retaining ≥ 80% of the sample was ≥7 h. Conclusions At group level, a wear-time of ≥7 h on ≥1HD day and ≥ 3 non-HD days is required to provide reliable PA data whilst retaining an acceptable sample size. PA is low across both HD and non- HD days and future research should focus on interventions designed to increase physical activity in both the intra and interdialytic period.


2012 ◽  
Vol 2012 ◽  
pp. 1-7 ◽  
Author(s):  
Li-ling Chuang ◽  
Ching-yi Wu ◽  
Keh-chung Lin ◽  
Shih-yu Lur

Objective. Test-retest reliability of the myotonometer was investigated in patients with subacute stroke.Methods. Twelve patients with substroke (3 to 9 months poststroke) were examined in standardized testing position twice, 60 minutes apart, with the Myoton-3 myometer to measure tone, elasticity, and stiffness of relaxed bilateral biceps and triceps brachii muscles. Intrarater reliability of muscle properties was determined using intraclass correlation coefficient (ICC), the standard error of measurement (SEM), and the minimal detectable change (MDC).Results. Intrarater reliability of muscle properties of bilateral biceps and triceps brachii muscles were good (ICCs=0.79–0.96) except for unaffected biceps tone (ICC=0.72). The SEM and MDC of bilateral biceps and triceps brachii muscles indicated small measurement error (SEM%<10%, MDC%<25%).Conclusion. The Myoton-3 myometer is a reliable tool for quantifying muscle tone, elasticity, and stiffness of the biceps and triceps brachii in patients with subacute stroke.


2002 ◽  
Vol 16 (3) ◽  
pp. 283-289 ◽  
Author(s):  
Mark Ferraro ◽  
Jennifer Hogan Demaio ◽  
Jennifer Krol ◽  
Chris Trudell ◽  
Keren Rannekleiv ◽  
...  

The Motor Status Scale (MSS) measures shoulder, elbow (maximum score = 40), wrist, hand, and finger movements (maximum score = 42), and expands the measurement of upper extremity impairment and disability provided by the Fugl-Meyer (FM) score. This work examines the interrater reliability and criterion validity of the MSS performed in patients admitted to a rehabilitation hospital 21 ± 4 days after stroke. Using the MSS and the FM, 7 occupational therapists masked to each other’s judgments, evaluated 12 consecutive patients with stroke. Two therapists evaluated 6 additional patients on consecutive days. Intraclass correlation coefficients were significant for each group of raters for the shoulder/elbow and for the wrist/hand (P < 0.0001); test-retest measures were also significant for the shoulder/elbow (Pearson correlation coefficient r = 0.99, P < 0.004) and for the wrist/hand (Pearson correlation coefficient r = 0.99, P < 0.003). The internal item consistency for the overall MSS was significant (Cronbach alpha = 0.98, P < 0.0001). Finally the correlation between the MSS and the FM (R 2 = 0.964) was significant (P < 0.0001). The MSS affords a reliable and valid assessment of upper limb impairment and disability following stroke.


Sign in / Sign up

Export Citation Format

Share Document