CFD simulation of HC-290 leakage from a split type room air conditioner

Author(s):  
C Ram Prakash ◽  
MR Gautham ◽  
D Mohan Lal ◽  
Sukumar Devotta ◽  
D Colbourne

HC-290 is one of the alternatives to HCFC22 in room air-conditioners. With the phase-down schedules in Kigali Amendment, it is imperative to use HC-290. However, there are concerns about its flammability in the event of a leak from the AC indoor unit (IDU). IEC 60335-2-40 has been revised to extend the capacity ranges for A2L refrigerants and is being further revised with a focus on A2 and A3 refrigerants. In real-life situations, furniture and occupants are present inside the room and these may positively or negatively influence the dispersion of any leaked HC-290. CFD simulation of dispersion of leaked HC-290 has been carried out for a variety of scenarios. The variables include leakage rates, IDU installation heights, IDU blower ON or OFF and types of furniture. Furniture, in general, appears to promote mixing, thereby reducing HC-290 stratification. The maximum concentration occurs on the side where the leak is directed by the momentum of the jet from IDU. There is no significant effect on the concentration distribution by the type and size of furniture with legs, although solid furniture has some marginal effect due to reduction of room free volume. The average concentration of HC-290 in the room is slightly more when the solid furniture like cupboards are placed some distance away from the IDU. The highest concentration at 30 cm above floor level, is 44% of LFL when the blower is ON, while it is 62% when the blower is OFF.

Author(s):  
Qixiang Zhang ◽  
Qiyan Feng ◽  
Xueqiang Zhu ◽  
Mei Zhang ◽  
Yanjun Wang ◽  
...  

In order to describe the changes of soil temperature field, air flow field and remediation situation with time during the process of thermally enhanced SVE (soil vapor extraction), a remediation experiment of benzene contaminated soil with single extraction pipe was carried out in a box device. The results showed that the whole temperature of the system was raised to 80 °C in 4 h. 43% of benzene were removed in the first 2% of the extraction time. After 24 h, the repair efficiency was close to 100%. The device can efficiently remove benzene from soil. By continuously monitoring the parameters in the operation process of the system, the spatial distribution of temperature and soil gas pollutant concentration with time was plotted. It showed the benzene concentration distribution in the soil gas was more consistent with the temperature distribution before the start of ventilation, and the concentration of benzene in the soil gas dropped rapidly after ventilation, while the temperature distribution was almost unaffected. In the treatment of soil with a benzene content of 17.8 mg∙kg−1, when the soil gas benzene concentration is the highest at 180 min, the peak value is 11,200 mg∙m−3, and the average concentration is 7629.4 mg∙m−3.


Energies ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4663
Author(s):  
Tatsuhiro Yamamoto ◽  
Akihito Ozaki ◽  
Myonghyang Lee

The number of houses with large, continuous spaces has increased recently. With improvements in insulation performance, it has become possible to efficiently air condition such spaces using a single air conditioner. However, the air conditioning efficiency depends on the placement of the air conditioner. The only way to determine the optimal placement of such air conditioners is to conduct an experiment or use computational fluid dynamic analysis. However, because the analysis is performed over a limited period, it is difficult to consider non-stationarity effects without using an energy simulation. Therefore, in this study, energy simulations and computational fluid dynamics analyses were coupled to develop a thermal environment analysis method that considers non-stationarity effects, and various air conditioner arrangements were investigated to demonstrate the applicability of the proposed method. The accuracy verification results generally followed the experimental results. A case study was conducted using the calculated boundary conditions, and the results showed that the placement of two air conditioners in the target experimental house could provide sufficient air conditioning during both winter and summer. Our results suggest that this method can be used to conduct preliminary studies if the necessary data are available during design or if an experimental house is used.


2017 ◽  
Vol 140 (1) ◽  
Author(s):  
Carlos R. de Nardin ◽  
Felipe T. Fernandes ◽  
Adriano J. Longo ◽  
Luciano P. Lima ◽  
Felix A. Farret ◽  
...  

This paper presents a comparison of air conditioners using the conventional heating, ventilation, and air conditioning heat pumps and the one using solar heat stored underground, also known as shallow geothermal air conditioning. The proposed air conditioner with solar heat stored underground reunites practical data from an implementation of the heuristic perturb-and-observe (P&O) control and a heat management technique. The aim is to find out the best possible heat exchange between the room ambient and the underground soil heat to reduce its overall consumption without any heat pump. Comparative tests were conducted in two similar rooms, each one equipped with one of the two types of air conditioning. The room temperature with the conventional air conditioning was maintained as close as possible to the temperature of the test room with shallow geothermal conditioning to allow an acceptable data validation. The experiments made both in the winter of 2014 and in the summer of 2015 in Santa Maria, South Brazil, demonstrated that the conventional air conditioner consumed 19.08 kWh and the shallow geothermal conditioner (SGC) consumed only 4.65 kWh, therefore, representing a reduction of energy consumption of approximately 75%.


2018 ◽  
Vol 40 (5) ◽  
pp. 560-575
Author(s):  
Jehanzeb Ahmad ◽  
M Najam Ul Islam ◽  
Jawwad Sabir

The benefits of thermal energy storage using phase change materials are well documented in the literature. Despite all the potential benefits of thermal energy storage, its commercial and widespread application remains limited. This is due to the high initial cost of phase change materials, extensive rework required in buildings, major modifications in HVAC systems, and the potential for leakage, fire and toxicity hazards. There is a strong need for a simple thermal energy storage solution which can be adopted by large number of consumers. Ductless split air-conditioners are portable, low cost, efficient and account for 70% of all air-conditioning systems sold worldwide each year. The present research provides a novel and low cost solution that incorporates thermal energy storage in these air conditioners, allowing them to run without electricity for 3 h. The paper deals with the detailed design aspects and engineering challenges that arise when incorporating thermal energy storage in these small units. A prototype air-conditioner with in-built thermal energy storage was developed, and all performance parameters presented have been validated through data obtained from the prototype. Our results indicate that thermal energy storage can be incorporated in split units in low cost and with minimal drop in overall energy efficiency of the system. Practical application: Incorporating thermal energy storage in split air-conditioners which enables them to run without grid for many hours has immense practical applications. Since around 50% power in any building is consumed by HVAC systems, being able to provide cooling during peak hours without using grid can significantly reduce load on the grid without compromising user comfort. For developing countries where load shedding is frequent, the users can run these air-conditioners without the use of generators or batteries thus saving costs and the environment.


1989 ◽  
Vol 176 ◽  
Author(s):  
Toshihiko Ohnuki ◽  
David E. Robertson

ABSTRACTThe migration of an anionic species of 60Co through soil has been examined utilizing data on the migration of radionuclides leached from an aqueous waste disposal site. Correlation coefficients between concentrations of the anionic species of 60Co and those of the particulate, cationic and non-ionic species of 60Co reveal that the anionic species of 60Co was not interconverted from the other species during migration. The cross correlations of changes in the concentrations of the anionic species of 60Co with time between three different down gradient positions give a calculated retardation factor of the anionic species of 60Co of approximately 19, being 1200 times lower than the results of laboratory measurements. The average concentration distribution of the anionic species of 60Co suggests that the migration of the anionic species of 60Co consists of two migration fractions which were driven by different migration mechanisms.


Author(s):  
V. A. Karkoulias ◽  
P. E. Marazioti ◽  
D. P. Georgiou ◽  
E. A. Maraziotis

This paper investigates how the structure of the flow field and the vertical distribution of the pollutant concentration near the wall facades of street canyons are affected by the presence of some elements such as street level galleries. Numerical results are presented for various gallery geometries in combination with facade roughness elements (balconies) for a canyon of an aspect ratio equal to h/w=2.33. The results were obtained by a Computational Fluid Dynamics (CFD) simulation employing the ANSYS-FLUENT suite that incorporated the k-e turbulent (RNG) model. The simulation generated several flow structures inside the canyon (mainly vortices), whose characteristic properties (e.g. number, strength and size) are discussed in terms of the effect of the galleries on the flow field structure and the roughness generated by the building façade balconies. The results indicate a significant influence on both the flow field structure and the mass concentration distribution of the polluting particles.


2019 ◽  
Vol 3 (3) ◽  
pp. 267
Author(s):  
Andi Asrul Sani ◽  
Adelia Enjelina Matondang ◽  
Guruh Kristiadi Kurniawan ◽  
Anggi Mardiyanto

Abstract: The use of glass material should consider the comfort of space in the building. Field of glass is needed as natural lighting and visual facilities between the occupants and the surrounding environment. Its function as natural lighting is often accompanied by an increase in temperature in buildings, considering that Indonesia is a tropical country. Building temperatures that increase due to incoming sunlight can cause discomfort to building occupants. Such conditions make building occupants use air conditioner (AC). The use of air conditioners can increase the value of building energy consumption. For this reason, research on the value of heat transfer in buildings or the value of OTTV (Overall Thermal Transfer Value). OTTV value calculation is done by manual calculation. Bandar Lampung City lecture building at the Sumatra Institute of Technology was chosen as the object of this study. From the results of the study found that the value of heat transfer of a building or OTTV (Overall Thermal Transfer Value) is influenced by the factor of the ratio of the window area to the facade or WWR (Window Wall Ratio) and the shading factor (Shading Coefficient).(Keywords: Keyword: energy consumption, building energy, glass. Abstract: Penggunaan material kaca semestinya mempertimbangkan kenyamanan ruang dalam bangunan. Bidang kaca diperlukan sebagai pencahayaan alami dan sarana visual antara penghuni dan lingkungan sekitar. Fungsinya sebagai pencahayaan alami seringkali disertai dengan peningkatan temperatur pada bangunan, mengingat Indonesia merupakan negara yang beriklim tropis. Temperatur bangunan yang meningkat akibat dari radiasi sinar matahari yang masuk dapat menyebabkan ketidaknyamanan bagi penghuni bangunan. Kondisi seperti itu membuat penghuni bangunan menggunakan air conditioner (AC). Penggunaan air conditioner tersebut dapat meningkatkan nilai konsumsi energi bangunan. Untuk  itu dilakukan penelitian mengenai nilai perpindahan panas dalam bangunan atau nilai OTTV (Overall Thermal Transfer Value). Penghitungan nilai OTTV dilakukan dengan penghitungan manual. Gedung kuliah Kota Bandar Lampung di Institut Teknologi Sumatera di pilih sebagai objek dalam penelitian ini. Dari hasil penelitian ditemukan bahwa nilai perpindahan panas suatu bangunan atau OTTV (Overall Thermal Transfer Value) dipengaruhi oleh faktor nilai perbandingan luas jendela terhadap bidang fasad atau WWR (Window Wall Ratio) dan faktor pembayangan (Shading Coefficient).Kata kunci : konsumsi energi, energi bangunan, kaca.


2021 ◽  
Vol 263 (5) ◽  
pp. 1186-1193
Author(s):  
Yoshiharu Soeta ◽  
Ei Onogawa

Air conditioners are widely used in buildings to maintain thermal comfort for long time. Air conditioners produce sounds during operation, and air conditioners are regarded as one of the main noise sources in buildings. Most sounds produced by the air conditioner do not fluctuate over time and sound quality of the steady sounds produced by the air conditioner have been evaluated. However, air conditioners sometimes produce low-level and impulsive sounds. Customers criticizes such sounds are annoying when they sleep and they spend time quietly in the living room. The aim of this study was to determine the factors that significantly influence the psycho-physiological response to the low-level impulsive sounds produced by air conditioners. We assessed the A-weighted equivalent continuous sound pressure level (LAeq) and factors extracted from the autocorrelation function (ACF). Subjective loudness, sharpness, annoyance, and electroencephalography (EEG) were evaluated. Multiple regression analyses were performed using a linear combination of LAeq, the ACF factors, and their standard deviations. The results indicated that LAeq, the delay time of the first maximum peak, the width of the first decay of the ACF, and the magnitude and width of the IACF could predict psycho-physiological responses to air conditioner sounds.


2020 ◽  
Vol 10 (22) ◽  
pp. 8067
Author(s):  
Tomohiro Mashita ◽  
Tetsuya Kanayama ◽  
Photchara Ratsamee

Air conditioners enable a comfortable environment for people in a variety of scenarios. However, in the case of a room with multiple people, the specific comfort for a particular person is highly dependent on their clothes, metabolism, preference, and so on, and the ideal conditions for each person in a room can conflict with each other. An ideal way to resolve these kinds of conflicts is an intelligent air conditioning system that can independently control air temperature and flow at different areas in a room and then produce thermal comfort for multiple users, which we define as the personal preference of air flow and temperature. In this paper, we propose Personal Atmosphere, a machine learning based method to obtain parameters of air conditioners which generate non-uniform distributions of air temperature and flow in a room. In this method, two dimensional air-temperature and -flow distributions in a room are used as input to a machine learning model. These inputs can be considered a summary of each user’s preference. Then the model outputs a parameter set for air conditioners in a given room. We utilized ResNet-50 as the model and generated a data set of air temperature and flow distributions using computational fluid dynamics (CFD) software. We then conducted evaluations with two rooms that have two and four air conditioners under the ceiling. We then confirmed that the estimated parameters of the air conditioners can generate air temperature and flow distributions close to those required in simulation. We also evaluated the performance of a ResNet-50 with fine tuning. This result shows that its learning time is significantly decreased, but performance is also decreased.


Sign in / Sign up

Export Citation Format

Share Document