scholarly journals Reliability of the radiographic views in supine position for evaluation of displaced midshaft clavicle fracture length

2020 ◽  
Vol 28 (3) ◽  
pp. 230949902095229
Author(s):  
Pinkawas Kongmalai ◽  
Peeraput Chiaprasert ◽  
Visit Rungsinaporn

Purpose: To analyze the agreement of the displaced midshaft clavicle fracture length measurement between each of the supine radiographic position (chest anteroposterior (AP), both clavicle AP, and 20° cephalic tilt clavicle AP view) and computed tomography (CT) scan of the clavicle. Furthermore, the inter- and intraobserver reliability of each radiographic position was analyzed. Methods: Prospective cross-sectional study was performed with patients diagnosed with displaced midshaft clavicle fracture treated conservatively. Three views of radiographs and CT scan of clavicle were obtained in supine position after informed consent. The measurement of fractured clavicle length was done by three observers at the time and after 4 weeks interval. Results: Thirty-three patients (25 males and 8 females), with a mean age of 45, were recruited. The agreement between each of the radiographic measurement and CT scan was good. The interobserver reliability was moderate to good for radiographic measurement. The highest intraclass correlation coefficient (ICC) of 0.80–0.81 was shown between the 20° cephalic tilt and the CT scan, followed by the both clavicle AP (0.75–0.77) and the chest AP (0.69–0.75), respectively. There was an excellent intraobserver reliability for all of the radiographic measurement with the ICC 0.92–0.99. Conclusion: The supine radiographs could be a useful option to measure the displaced midshaft clavicle fracture length. The recommended view was the 20° cephalic tilt clavicle AP view in supine position to best evaluate the fractured clavicle length.

2010 ◽  
Vol 128 (3) ◽  
pp. 130-136 ◽  
Author(s):  
Márcia Cristina Bastos Boëchat ◽  
Rosane Reis de Mello ◽  
Maria Virgínia Peixoto Dutra ◽  
Kátia Silveira da Silva ◽  
Pedro Daltro ◽  
...  

CONTEXT AND OBJECTIVE: High-resolution computed tomography (HRCT) of the lungs is more sensitive than radiographs for evaluating pulmonary disease, but little has been described about HRCT interpretation during the neonatal period or shortly afterwards. The aim here was to evaluate the reliability of the interpretation of HRCT among very low birth weight premature infants (VLBWPI; < 1500 g). DESIGN AND SETTING: Cross-sectional study on intra and interobserver reliability of HRCT on VLBWPI. METHODS: 86 VLBWPI underwent HRCT. Two pediatric radiologists analyzed the HRCT images. The reliability was measured by the proportion of agreement, kappa coefficient (KC) and positive and negative agreement indices. RESULTS: For radiologist A, the intraobserver reliability KC was 0.79 (confidence interval, CI: 0.54-1.00) for normal/abnormal examinations; for each abnormality on CT, KC ranged from 0.05 to 1.00. For radiologist B, the intraobserver reliability KC was 0.79 (CI: 0.54-1.00) for normal/abnormal examinations; for each abnormality on CT, KC ranged from 0.37 to 0.83. The interobserver agreement was 88% for normal/abnormal examinations and KC was 0.71 (CI: 0.5- 0.93); for most abnormal findings, KC ranged from 0.51-0.67. CONCLUSION: For normal/abnormal examinations, the intra and interobserver agreements were substantial. For most of the imaging findings, the intraobserver agreement ranged from moderate to substantial. Our data demonstrate that in clinical practice, there is no reason for more than one tomographic image evaluator, provided that this person is well trained in VLBWPI HRCT interpretation. Analysis by different observers should be reserved for research and for difficult cases in clinical contexts.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Shunsuke Nakakura ◽  
Ryo Asaoka ◽  
Etsuko Terao ◽  
Yuki Nagata ◽  
Yasuko Fukuma ◽  
...  

Abstract Background This study investigated the agreement between a new rebound tonometer, IC200, and IcarePRO and Goldmann applanation tonometry (GAT). Methods This was a prospective cross-sectional study. We measured the intraocular pressure (IOP) in 145 eyes of 145 glaucoma patients in the sitting position using GAT, IcarePRO, and IC200. IcarePRO and IC200 measurements were also obtained in the supine position. IC200 measurement was performed using two modes: single six (IC200-single) and automatic (IC200-continuous) six-measurements mode. Results All tonometers provided high reproducibility in both positions (all intraclass correlation coefficients > 0.90), although it was highest with GAT, followed by IC200-continuous and IC200-single and then IcarePRO. In the sitting position, the mean (± SD) IOPs of GAT, IcarePRO, IC200-single, and IC200-continuous were 14.5 ± 2.9 mmHg, 13.3 ± 3.2 mmHg, 11.6 ± 3.2 mmHg, and 11.5 ± 3.2 mmHg, respectively. IOPs measured with IcarePRO or IC200 were significantly lower than those with GAT, particularly in patients with low IOP. IOPs measured with all tonometers were significantly elevated in the supine position as compared with the sitting position, but this difference was significantly greater with IC200-single and IC200-continuous compared with IcarePRO. IOP elevation was significant in eyes without bleb versus those with bleb, but this finding was not observed when IOP was measured with IcarePRO. The IOPs of the single and continuous modes of IC200 were interchangeable in both positions. Conclusions GAT, IcarePRO, and IC200 had sufficiently high reproducibility, but measurements with IcarePRO may not be accurate in the supine position. Elevation of IOP in the supine position, especially in eyes with bleb, was more sensitively captured with IC200 than with IcarePRO. Trial registration Japan Clinical Trials Register, No. UMIN000039982.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Olga-Cecilia Vargas-Pinilla ◽  
Eliana-Isabel Rodríguez-Grande

AbstractThe protocol established for taking hand grip dynamometry measurements determines that the patient must be in a sitting position. This protocol cannot be applied due to the patient’s conditions in some cases, such as abdominal surgery, musculoskeletal spine or hip injuries. The purpose was to determine the reproducibility and level of agreement between the Handgrip dynamometry in supine position with the elbow flexed or extended, and the one measured in the sitting position, the design was a descriptive cross-sectional study. The population were young apparently healthy between 18 and 30 years of age (N = 201). Handgrip measurement was performed on both upper limbs in a sitting position with a flexed elbow, a supine position with a flexed elbow, and supine position with the elbow extended. Reproducibility was nearly perfect in all positions (ICC 0.95–0.97). Regarding the level of agreement for the comparison between sitting and supine positions with a flexed elbow, an average difference of − 0.406. For supine position with an extended elbow and supine position with a flexed elbow, the average difference was − 1.479. Considering the results, clinicians or researchers can choose any of the positions evaluated herein and obtain reliable results as long as the standardization process is followed.


BMJ Open ◽  
2020 ◽  
Vol 10 (8) ◽  
pp. e033839
Author(s):  
Colette Andrea Cunningham-Myrie ◽  
Novie O Younger ◽  
Katherine P Theall ◽  
Lisa-Gaye Greene ◽  
Parris Lyew-Ayee ◽  
...  

ObjectiveTo derive estimates of the associations between measures of the retail food environments and mean body mass index (BMI) in Jamaica, a middle-income country with increasing prevalence of obesity.DesignCross-sectional study.SettingData from the Jamaica Health and Lifestyle Survey 2008 (JHLS II), a nationally representative population-based survey that recruited persons at their homes over a 4-month period from all 14 parishes and 113 neighbourhoods defined as enumeration districts.ParticipantsA subsample of 2529 participants aged 18–74 years from the JHLS II who completed interviewer-administered surveys, provided anthropometric measurements and whose addresses were geocoded.Primary outcome measureMean BMI, calculated as weight divided by height squared (kg/m2).ResultsThere was significant clustering across neighbourhoods for mean BMI (intraclass correlation coefficients=4.16%). Fully adjusted models revealed higher mean BMI among women, with further distance away from supermarkets (β=0.12; 95% CI 8.20×10−3, 0.24; p=0.036) and the absence of supermarkets within a 1 km buffer zone (β=1.36; 95% CI 0.20 to 2.52; p=0.022). A 10 km increase in the distance from a supermarket was associated with a 1.7 kg/m2 higher mean BMI (95% CI 0.03 to 0.32; p=0.020) in the middle class. No associations were detected with fast-food outlets or interaction by urbanicity.ConclusionsHigher mean BMI in Jamaicans may be partially explained by the presence of supermarkets and markets and differ by sex and social class. National efforts to curtail obesity in middle-income countries should consider interventions focused at the neighbourhood level that target the location and density of supermarkets and markets and consider sex and social class-specific factors that may be influencing the associations.


BMJ Open ◽  
2014 ◽  
Vol 4 (10) ◽  
pp. e005947 ◽  
Author(s):  
Cheng-Shyuan Rau ◽  
Hang-Tsung Liu ◽  
Shiun-Yuan Hsu ◽  
Tzu-Yu Cho ◽  
Ching-Hua Hsieh

ObjectivesTo provide an overview of the demographic characteristics of patients with positive blood alcohol concentration (BAC) and to investigate the performance of brain CT scans in these patients.DesignCross-sectional study.SettingTaiwan.Participants2192 patients who had undergone a test for blood alcohol of 13 233 patients registered in the Trauma Registry System between 1 January 2009 and 31 December 2012. A BAC level of 50 mg/dL was defined as the cut-off value. Detailed information was retrieved from the patients with positive BAC (n=793) and was compared with information from those with a negative BAC (n=1399).Main outcome measuresGlasgow Coma Scale (GCS) and Injury Severity Score (ISS) as well as the performance and findings of obtained brain CT scans.ResultsPatients with positive BAC had a higher rate of face injury, but a lower GCS score, a lower rate of head and neck injury, a lower ISS and New Injury Severity Score. Alcohol use was associated with a shorter length of hospital stay (8.6 vs 11.4 days, p=0.000) in patients with an ISS of <16. Of 496 patients with positive BAC who underwent brain CT, 164 (33.1%) showed positive findings on CT scan. In contrast, of 891 patients with negative BAC who underwent brain CT, 389 (43.7%) had positive findings on CT scan. The lower percentage of positive CT scan findings in patients with positive BAC was particularly evident in patients with an ISS <16 (18.0% vs 28.8%, p=0.001).ConclusionsPatients who consumed alcohol tended to have a low GCS score and injuries that were less severe. However, given the significantly low percentage of positive findings, brain CT might be overused in these patients with less severe injuries.


2020 ◽  
Vol 3 (2) ◽  
pp. 8-12
Author(s):  
Bishnu Pokharel ◽  
Ashok Raj Pant ◽  
Pashupati Chaudhary ◽  
Guru Prasad Khanal

Background: Most of the proximal femur fractures are managed surgically by internal fiation with a variety of implants. Improperly designed or ill-fited implant may lead to a failure of fiation, breakage of implant and nonunion, thus increasing the morbidity and the cost of treatment. This study was conducted to evaluate the radiographic morphometry of the proximal femur which may be helpful in designing the implants for the Nepalese population. Methods: In this cross-sectional study, 84 patients aged 18 years and above with traumatic unilateral hip fracture were enrolled. Anthropometric measurements were recorded. The postoperative check X-ray in the antero-posterior view of the pelvis and bilateral hip were assessed. Various morphometric parameters of the proximal femur were measured and recorded in the radiograph of the unaffcted limb using a digital caliper. Results: Out of 84 patients, 47 were male. The mean ± SD femoral neck width, femoral neck length, femoral axis length, cervico-diaphyseal angle, acetabular tear-drop distance, and great trochanter-pubic symphysis distance were 36.10 ± 5.67 mm, 28.29 ± 4.18 mm, 104.51 ± 9.56 mm, 130.35 ± 8.67°, 32.56 ± 11.05 mm, and 163.07 ± 10.71 mm respectively. The femoral neck width was found to be signifiantly larger in males (39.08 ± 3.06 mm) than in females (32.32 ± 5.99 mm, p < 0.001). Conclusion: This study determined the radiographic measurement of the proximal femur and found that the femoral neck width of the males was larger than that of the females.


Biomolecules ◽  
2020 ◽  
Vol 10 (2) ◽  
pp. 295
Author(s):  
Kjersti Sletten Bakken ◽  
Ingvild Oma ◽  
Synne Groufh-Jacobsen ◽  
Beate Stokke Solvik ◽  
Lise Mette Mosand ◽  
...  

Mild to moderate iodine deficiency is common among women of childbearing age. Data on iodine status in infants are sparse, partly due to the challenges in collecting urine. Urinary iodine concentration (UIC) is considered a good marker for recent dietary iodine intake and status in populations. The aim of this study was to investigate the reliability of iodine concentration measured in two spot-samples from the same day of diaper-retrieved infant urine and in their mothers’ breastmilk. We collected urine and breastmilk from a sample of 27 infants and 25 mothers participating in a cross-sectional study at two public healthcare clinics in Norway. The reliability of iodine concentration was assessed by calculating the intraclass correlation coefficients (ICC) and the coefficient of variation (CV). The ICC for infants’ urine was 0.64 (95% confidence interval (CI) 0.36–0.82), while the ICC for breastmilk was 0.83 (95% CI 0.65–0.92) Similarly, the intraindividual CV for UIC was 0.25 and 0.14 for breastmilk iodine concentration (BIC). Compared to standard methods of collecting urine for measuring iodine concentration, the diaper-pad collection method does not substantially affect the reliability of the measurements.


2016 ◽  
Vol 27 (5) ◽  
pp. 617-637 ◽  
Author(s):  
Mariska J. van Dijk ◽  
Janneke M. de Man-van Ginkel ◽  
Thóra B. Hafsteinsdóttir ◽  
Marieke J. Schuurmans

The early detection of depression after stroke is essential for the optimization of recovery in aphasic stroke patients. The purpose of this study was to evaluate the psychometric properties of the Signs of Depression Scale (SODS), a non-language-based screening instrument. We conducted a cross-sectional study in a sample of 58 stroke patients in a rehabilitation center. The internal consistency and interrater reliability were good (α = .71 and intraclass correlation coefficient [ICC] = .79). The pre-defined hypotheses confirmed the construct validity, and the correlation between the SODS and the Patient Health Questionnaire–9 (PHQ-9) was moderate ( rb = .32). At a cutoff score of ≥1, the sensitivity was 0.80, and the specificity was 0.39. These findings indicate that the SODS is appropriate to screen for depressive symptoms and can be used by nurses to identify symptoms of depression in patients with aphasia who require further assessment.


2014 ◽  
Vol 31 (4) ◽  
pp. 189-193
Author(s):  
T Islam ◽  
SA Azad ◽  
ME Karim ◽  
L Khondker ◽  
K Rahman

A cross sectional study carried out with patients having suspected paranasal sinus (PNS) mass during January 2009 to October 2010 to evaluate the fungal diseases in PNS by computed tomographic(CT) image and comparison of the findings of this modality with histopathological result. Among the total 76 patients, the mean age of the patients was 35.95 ± 18.24 and common complaints of the patients were nasal obstruction (73.7%) and maximum 53.9% patients had PNS mass in maxillary sinuses. Out of all cases 10 were diagnosed as having fungal infection/mass by CT scan and confirmed by histopathological evaluation. Two cases were diagnosed as having fungal infection/mass by CT scan but not confirmed by histopathological findings. Of 64 cases of other than fungal infection/mass, which were diagnosed by CT scan, six were confirmed as having fungal infection/mass and 58 were other than having fungal infection/mass by histopathology. Sensitivity of CT scan to diagnose fungal infection/mass was 62.5%, specificity 96.7%, positive predictive value 83.3%, negative predictive value 90.6% and accuracy 89.5%. CT scan of the fungal diseases in paranasal sinus provides more information and better image quality and CT diagnosis correlate well with the findings of histopathology. DOI: http://dx.doi.org/10.3329/jbcps.v31i4.21002 J Bangladesh Coll Phys Surg 2013; 31: 189-193


Sign in / Sign up

Export Citation Format

Share Document