Calibration of a Small Venturimeter for Wet Steam at Low Reynolds Number

Author(s):  
M. D. Bennett ◽  
K. Martin

A device was required to measure the flow rate of steam through a small thrust bearing over the range 0–1·5 kg/h at pressures varying from 4·5 to 10 bar abs. and for steam quality varying from 0·75 dry to 100°C superheat. The ranges appeared to be outside those of existing instruments and not covered by existing design data for differential pressure devices; nor could the authors find any published work on the metering of wet steam at these low flow rates. Accordingly a 12·7-mm diameter venturimeter having an area ratio of 0·25 was made from stainless steel and has been calibrated for wet steam using a compounded differential U-tube manometer. The manometer and associated equipment is extremely simple and cheap to construct, and consists entirely of easily machined parts and standard pipe fittings. The results indicate that the discharge coefficient is very low and approximately a linear function of Reynolds number over the range tested.

Author(s):  
William Alexander Carrillo Ibañez ◽  
Márcio Demétrio ◽  
Amir Oliveira ◽  
Fernando Pereira

Abstract This works aims at characterizing the flow in the outlet of three gas injectors used in atmospheric burners and developing correlations for the discharge coefficient, air entrainment, momentum and energy flow rates. These devices have millimeter sized orifices, a cup-like region at the injector outlet and the flow occurs in the transition from the laminar to the fully turbulent regimes. The pressure drop was measured and correlated as a function of the orifice Reynolds number for the three injectors. The correlations are able to predict the discharge coefficient within ± 5% deviation from the measurements in the range 90 < Re < 4400. The axial velocity and turbulent intensity were measured at the outlet of the injectors using a hot-wire anemometer at the orifice Reynolds number of 3060, which is typical of the applications. The measurements were compared to CFD solutions using the gamma - Re-theta RANS transition model in the STAR-CCM+ commercial package. The results indicate the strong influence of the shape of the outlet cup-like region of the injectors in the development of an internal mixing layer and the external mixing layer in the free jet. The momentum and energy flow rates for the injector model with the largest cup are reduced to 50% and 21%, respectively, of the simplest gas injector. However, the gas jet in this injector carries 28% of the stoichiometric air before leaving the cup. These aspects must be taken into account in the preliminary design of atmospheric burners.


1965 ◽  
Vol 87 (2) ◽  
pp. 525-529 ◽  
Author(s):  
S. Soundranayagam

The flow through two ISA nozzles of area ratio zero and 0.4 was investigated to determine the nature of the flow and its variation with Reynolds number. Separation occurs within the nozzle of zero area ratio, the size of the bubble increasing with decreasing Reynolds number. The predicted discharge coefficient based on a simplified flow model agrees with experiment for large Reynolds numbers. Upstream influences affect the performance of the nozzle of area ratio 0.4. The flows through the two nozzles are not comparable, and potential-flow results cannot be used to explain flow in venturis and nozzles in pipes. The discharge-coefficient curve for area ratio 0.4 shows a distinct hump when based on the head differential measured as for venturis, but no hump when based on the head differential across the corner taps.


Water ◽  
2019 ◽  
Vol 11 (4) ◽  
pp. 773
Author(s):  
Mohamad H. El Hattab ◽  
Ana Mijic ◽  
Dejan Vernon

Conventional triangular weirs have been originally developed to measure, divert, and control surface water. However, a special application of these weirs, such as for low flow measurements in full-scale monitoring of Green Infrastructure (GI), is not well investigated. Available head-discharge relationships for triangular sharp-crested weirs are only valid under a free-flow regime. Literature focusing on the V-notch weir usage for GI assessment suggests that it is necessary to calibrate the head-discharge relationship before its use. This study focuses on understanding the effects of site constraints on the measurement performance of a V-notch weir at low flow rates, and the validity of equations derived for similar applications that can be found in the literature. The variation of discharge coefficient in various flow regimes was investigated experimentally based on calibration runs covering flow rates between 0.054 l/s and 7 l/s. The results show that for 30° and 45° V-notch weirs, three flow regimes can be identified. It was observed that literature equations to calculate the discharge coefficient are valid for partially-contracted triangular weirs only at heads greater than vertex distance from the channel. However, for low flows that are expected to occur when estimating the full-scale performance of GI, the equations available from the literature for similar site conditions underestimated the flow rate between 85% and 17%. This emphasises the need for accurate calibration of a V-notch device under the site conditions to achieve the necessary level of accuracy in GI performance estimation. The procedure outlined in this work can be easily replicated to determine the optimal monitoring system configuration. Alternatively, if the site conditions would match those described in this study, the computed discharge using the proposed relations, in combination with the general V-notch weir equation, provides a significant improvement in the accuracy of measurements, expands the head applicability range of V-notch weirs, and enables better understanding of GI performance at the full scale.


2009 ◽  
Author(s):  
T. J. John ◽  
H. Hegab

In this paper, two microfluidic bubble generators are proposed and modeled using COMSOL®. The first device consists of two microchannels perpendicular to each other. This arrangement of channels has been successfully used for generating bubbles with diameters in the millimeter range previously. The feasibility of miniaturizing this structure has been investigated in this paper. The bubble diameter generated using this method is found to vary inversly with the liquid flow rate (i.e. flow velocity). This is disadvantageous in terms of pressure drop while trying to generate microbubbles in microchannels. Therefore a second device, an extension of the first, has been proposed for eliminating this drawback by introducing a solid structure in the liquid channel right in front of the gas channel. The suitability of this device as a microbubble generator is checked through COMSOL® simulation model. At low flow rates, the bubble diameter is not significantly affected by the presence of the solid structure in the microchannel. In both devices the bubble attached itself to the walls at low Reynolds number but this did not happen at high Reynolds number. Further investigations are done in this study for understanding the effect of different shaped structures on the diameter of the microbubble.


2003 ◽  
Vol 30 (5) ◽  
pp. 525-541 ◽  
Author(s):  
Sanjeev Bharani ◽  
S.N. Singh ◽  
V. Seshadri ◽  
R. Chandramouli

ORL ◽  
2021 ◽  
pp. 1-5
Author(s):  
Jingjing Liu ◽  
Tengfang Chen ◽  
Zhenggang Lv ◽  
Dezhong Wu

<b><i>Introduction:</i></b> In China, nasal cannula oxygen therapy is typically humidified. However, it is difficult to decide whether to suspend nasal cannula oxygen inhalation after the nosebleed has temporarily stopped. Therefore, we conducted a preliminary investigation on whether the use of humidified nasal cannulas in our hospital increases the incidence of epistaxis. <b><i>Methods:</i></b> We conducted a survey of 176,058 inpatients in our hospital and other city branches of our hospital over the past 3 years and obtained information concerning their use of humidified nasal cannulas for oxygen inhalation, nonhumidified nasal cannulas, anticoagulant and antiplatelet drugs, and oxygen inhalation flow rates. This information was compared with the data collected at consultation for epistaxis during these 3 years. <b><i>Results:</i></b> No significant difference was found between inpatients with humidified nasal cannulas and those without nasal cannula oxygen therapy in the incidence of consultations due to epistaxis (χ<sup>2</sup> = 1.007, <i>p</i> &#x3e; 0.05). The same trend was observed among hospitalized patients using anticoagulant and antiplatelet drugs (χ<sup>2</sup> = 2.082, <i>p</i> &#x3e; 0.05). Among the patients with an inhaled oxygen flow rate ≥5 L/min, the incidence of ear-nose-throat (ENT) consultations due to epistaxis was 0. No statistically significant difference was found between inpatients with a humidified oxygen inhalation flow rate &#x3c;5 L/min and those without nasal cannula oxygen therapy in the incidence of ENT consultations due to epistaxis (χ<sup>2</sup> = 0.838, <i>p</i> &#x3e; 0.05). A statistically significant difference was observed in the incidence of ENT consultations due to epistaxis between the low-flow nonhumidified nasal cannula and nonnasal cannula oxygen inhalation groups (χ<sup>2</sup> = 18.428, <i>p</i> &#x3c; 0.001). The same trend was observed between the 2 groups of low-flow humidified and low-flow nonhumidified nasal cannula oxygen inhalation (χ<sup>2</sup> = 26.194, <i>p</i> &#x3c; 0.001). <b><i>Discussion/Conclusion:</i></b> Neither high-flow humidified nasal cannula oxygen inhalation nor low-flow humidified nasal cannula oxygen inhalation will increase the incidence of recurrent or serious epistaxis complications; the same trend was observed for patients who use anticoagulant and antiplatelet drugs. Humidification during low-flow nasal cannula oxygen inhalation can prevent severe and repeated epistaxis to a certain extent.


2021 ◽  
Vol 9 (1) ◽  
Author(s):  
Tobias Blanke ◽  
Markus Hagenkamp ◽  
Bernd Döring ◽  
Joachim Göttsche ◽  
Vitali Reger ◽  
...  

AbstractPrevious studies optimized the dimensions of coaxial heat exchangers using constant mass flow rates as a boundary condition. They show a thermal optimal circular ring width of nearly zero. Hydraulically optimal is an inner to outer pipe radius ratio of 0.65 for turbulent and 0.68 for laminar flow types. In contrast, in this study, flow conditions in the circular ring are kept constant (a set of fixed Reynolds numbers) during optimization. This approach ensures fixed flow conditions and prevents inappropriately high or low mass flow rates. The optimization is carried out for three objectives: Maximum energy gain, minimum hydraulic effort and eventually optimum net-exergy balance. The optimization changes the inner pipe radius and mass flow rate but not the Reynolds number of the circular ring. The thermal calculations base on Hellström’s borehole resistance and the hydraulic optimization on individually calculated linear loss of head coefficients. Increasing the inner pipe radius results in decreased hydraulic losses in the inner pipe but increased losses in the circular ring. The net-exergy difference is a key performance indicator and combines thermal and hydraulic calculations. It is the difference between thermal exergy flux and hydraulic effort. The Reynolds number in the circular ring is instead of the mass flow rate constant during all optimizations. The result from a thermal perspective is an optimal width of the circular ring of nearly zero. The hydraulically optimal inner pipe radius is 54% of the outer pipe radius for laminar flow and 60% for turbulent flow scenarios. Net-exergetic optimization shows a predominant influence of hydraulic losses, especially for small temperature gains. The exact result depends on the earth’s thermal properties and the flow type. Conclusively, coaxial geothermal probes’ design should focus on the hydraulic optimum and take the thermal optimum as a secondary criterion due to the dominating hydraulics.


1986 ◽  
Vol 108 (3) ◽  
pp. 540-546 ◽  
Author(s):  
H. J. Carper ◽  
J. J. Saavedra ◽  
T. Suwanprateep

Results are presented from an experimental study conducted to determine the average convective heat transfer coefficient for the side of a rotating disk, with an approximately uniform surface temperature, cooled by a single liquid jet of oil impinging normal to the surface. Tests were conducted over a range of jet flow rates, jet temperatures, jet radial positions, and disk angular velocities with various combinations of three jet nozzle and disk diameters. Correlations are presented that relate the average Nusselt number to rotational Reynolds number, jet Reynolds number, jet Prandtl number, and dimensionless jet radial position.


Author(s):  
Yo Han Jung ◽  
Young Uk Min ◽  
Jin Young Kim

This paper presents a numerical investigation of the effect of tip clearance on the suction performance and flow characteristics at different flow rates in a vertical mixed-flow pump. Numerical analyses were carried out by solving three-dimensional Reynolds-averaged Navier-Stokes equations. Steady computations were performed for three different tip clearances under noncavitating and cavitating conditions at design and off-design conditions. The pump performance test was performed for the mixed-flow pump and numerical results were validated by comparing the experimental data for a system characterized by the original tip clearance. It was shown that for large tip clearance, the head breakdown occurred earlier at the design and high flow rates. However, the head breakdown was quite delayed at low flow rate. This resulted from the cavitation structure caused by the tip leakage flow at different flow rates.


2005 ◽  
Vol 127 (3) ◽  
pp. 679-684 ◽  
Author(s):  
S. Charles ◽  
O. Bonneau ◽  
J. Fre^ne

The characteristics of hydrostatic bearings can be influenced by the compensating device they use, for example, a thin-walled orifice (diaphragm). The flow through the orifice is given by a law where an ad hoc discharge coefficient appears, and, in order to guarantee the characteristics of the hydrostatic bearing, this coefficient must be calibrated. The aim of this work is to provide an accurate estimation of the discharge coefficient under specific conditions. Therefore an experimental bench was designed and a numerical model was carried out. The results obtained then by the experimental and theoretical approach were compared with the values given by the literature. Finally, the influence of the discharge coefficient on the behavior of a thrust bearing is examined.


Sign in / Sign up

Export Citation Format

Share Document