scholarly journals A Review on Chemical and Ecological Status of Lonar Lake

2021 ◽  
Vol 16 (1) ◽  
pp. 61-69
Author(s):  
R. R. Surve ◽  
A. V. Shirke ◽  
R. R. Athalye ◽  
M. M. Sangare

Meteoric impact crater Lonar Lake is located in Buldhana district of Maharashtra always remained as point of attraction among the researchers of different fields since many decades as it has rich chemical and biological diversity in it. Physicochemical qualities of water samples were analysed by many researchers and revealed that, the water is alkaline with high pH and categorised by high concentration of Alkalinity, Sulphate, sodium, Total dissolved solids, Magnesium, Chloride and Dissolved Oxygen. Due to this, interesting microbial complexity have been developed across the Lake. From this review, it is found that alkalinity has been decreased by nearly 19 percent, salinity nearby 7 percent and therefore its pH is seen to drop up to 6.2. This decreases is mainly due to process of sedimentation of salt at the bottom of the Lake. This has affected the living of Micro-organism. Many researches have been carried to study the nature of Lonar Lake from different fields. Therefore, an attempt is made to assemble important aspects of Lonar Lake from various fields. Conservation of Lonar Lake with proper management is necessary as it has uniqueness and beauty in itself.

2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Nazira Sulaiman ◽  
Saiful Irwan Zubairi ◽  
Norrakiah Abdullah Sani ◽  
Zalifah Mohd Kasim

This study was conducted to determine the physicochemical properties, microbiological quality, level of consumption, and effects of treated water from paid water filtration machines on health of the residents of Bandar Baru Bangi and Kajang, Selangor. The number of water samples taken for this study was 15 from the paid water filtration machines studied. The physicochemical assessment such as determination of pH, turbidity, total dissolved solids, conductivity, and dissolved oxygen was conducted, while the inductively coupled plasma mass spectrometry (ICP-MS) was used to determine the mineral content of the treated water. The microbiological quality was determined using the pour plate method for colony count (22°C incubation for 72 hours and 37°C for 24 hours), while for coliforms and Escherichia coli, the membrane filtration method was utilized. The samples of treated water from the paid water filters were based on triplicate sampling (n = 3). The pH, turbidity, total dissolved solid values, and heavy metal concentration were within the safe level according to the Malaysian National Standard for Drinking Water Quality, Ministry of Health (MOH). The overall range for the pH values of the treated water samples was between 6.50 and 7.15, where this was within the recommended range. The total dissolved solids showed that all the treated water samples were in the range of the recommended standard (27 to 92 mg/L). The range of turbidity values for all the treated water samples was from 1.7 to 6 NTU, and the dissolved oxygen range was from 7.7 to 8.2 mg/L. The colony count results showed that most of the water samples complied with the standards of <4 log cfu/mL at 37°C and <3 log cfu/mL at 22°C of incubation temperatures. However, there was the presence of coliforms in four (4/15) of the treated water samples being at more than 4 cfu/100 mL, while E. coli was absent in all of the treated water samples. The overall results showed that all samples were safe to drink according to the Industrial Guide to Good Hygiene Practice by Automatic Vending Association of Britain (2000) and Food Act (1983) except for the four treated water samples (C, D, H, and I). For that reason, the filtered waters require quality evaluation and management, while the filters need to be replaced according to their designated schedule in order to ascertain that the drinking water is safe to be consumed by the public.


2017 ◽  
Vol 23 (2) ◽  
Author(s):  
AJAY KUMAR RAJAWAT ◽  
PRAVEEN KUMAR

An attempt has been made to study the Physico-chemical condition of water of Yamuna River at Gokul Barrage, Mathura, (UP). The time period of study was July 2015 to June 2016. Three water samples were selected from different sites in each month for study. The parameters studied were Temperature, Turbidity, pH, DO, BOD, COD, Total Dissolved Solids and Suspended Solids. Almost all the parameters were found above the tolerance limit.


1998 ◽  
Vol 38 (12) ◽  
pp. 73-76 ◽  
Author(s):  
B. S. W. Ho ◽  
T.-Y Tam

A total of 64 beach water samples with various bacteriological quality (Grades 1 to 4) were analysed for their bacteriological and parasitological contents (E coli and Giardia cysts respectively). Results indicated that Giardia cysts were detected in less than 10% of the Grade 1 beach water samples with E coli concentrations of &lt;24/100mL. For Grades 2, 3 & 4 beach water samples, Giardia cysts were found, respectively, in 85, 50 and 64% of the samples. Except for one beach water sample which had an unusually high concentration of Giardia cysts (23 cysts/L), they were generally present at moderate concentrations (&lt;10 cysts/L) in all other beach water samples. Despite moderate levels of Giardia cysts present in beach water of different grades, the potential health risk faced by swimmers bathing in local beach water needs to be carefully assessed as Giardia is known to have a low infectious dose.


2003 ◽  
Vol 47 (10) ◽  
pp. 175-181 ◽  
Author(s):  
G. Buitrón ◽  
M.-E. Schoeb ◽  
J. Moreno

The operation of a sequencing batch bioreactor is evaluated when high concentration peaks of a toxic compound (4-chlorophenol, 4CP) are introduced into the reactor. A control strategy based on the dissolved oxygen concentration, measured on line, is utilized. To detect the end of the reaction period, the automated system search for the moment when the dissolved oxygen has passed by a minimum, as a consequence of the metabolic activity of the microorganisms and right after to a maximum due to the saturation of the water (similar to the self-cycling fermentation, SCF, strategy). The dissolved oxygen signal was sent to a personal computer via data acquisition and control using MATLAB and the SIMULINK package. The system operating under the automated strategy presented a stable operation when the acclimated microorganisms (to an initial concentration of 350 mg 4CP/L), were exposed to a punctual concentration peaks of 600 mg 4CP/L. The 4CP concentrations peaks superior or equals to 1,050 mg/L only disturbed the system from a short to a medium term (one month). The 1,400 mg/L peak caused a shutdown in the metabolic activity of the microorganisms that led to the reactor failure. The biomass acclimated with the SCF strategy can partially support the variations of the toxic influent since, at the moment in which the influent become inhibitory, there is a failure of the system.


2008 ◽  
Vol 68 (1) ◽  
pp. 115-122 ◽  
Author(s):  
MB. Cunha-Santino ◽  
SP. Gouvêa ◽  
I. Bianchini Jr ◽  
AAH. Vieira

This study aimed to discuss and describe the oxygen consumption during aerobic mineralization of organic products (cells and excretion products) from five unialgal cultures: Cryptomonas sp., Microcystis aeruginosa, Anabaena spiroides, Thalassiosira sp. and Aulacoseira granulata. These species were isolated from Barra Bonita reservoir (22º 29’ S and 48º 34’ W) and cultivated in the laboratory. From each culture, two decomposition chambers were prepared; each chamber contained about 130 mg.L-1 of carbon from water samples of the reservoir. The chambers were aerated and incubated in the dark at 20.0 ºC. The concentration of dissolved oxygen, pH values and electrical conductivity of the solutions were determined during a period of 10 days. The results indicated increases in oxygen consumption for all the solutions studied and also for electrical conductivity. The pH values presented a decreasing tendency throughout the experiment. Oxygen consumption varied from 43 (Aulacoseira granulata chamber) to 345 mg O2 g-1 C (Anabaena spiroides chamber). Decrease in pH values was probably due to increase in CO2 concentration from microbial respiration. Increase in electrical conductivity might be due to the liberation of ions during decomposition. The results demonstrate the potentiality of the studied genera in influencing oxygen availability followed by a die-off event. It also indicates the possibility of changing of the electrical conductivity and pH values in the water column due the aerobic algae mineralization.


Author(s):  
Vasudha Lingampally ◽  
V.R. Solanki ◽  
D. L. Anuradha ◽  
Sabita Raja

In the present study an attempt has been made to evaluate water quality and related density of Cladocerans for a period of one year, October 2015 to September 2016. Water quality parameters such as temperature, PH, total dissolved solids, dissolved oxygen, biological oxygen demand, total alkalinity, total hardness, chlorides, phosphates, and nitrates are presented here to relate with the abundance of Cladocerans. The Cladoceran abundance reflects the eutrophic nature of the Chakki talab.


2021 ◽  
Vol 46 (2) ◽  
Author(s):  
O.A. Oguntade ◽  
V.I. I Fesiokwu ◽  
O. S. Sule

High concentration of contaminants in drinking water can affect human health. This study assessed quality of groundwater at industrial and residential areas of Sango Ota, Ogun State. Water samples were collected in triplicates from 8 wells at industrial and residential areas and analyzed for its physicochemical properties. The pH, electrical conductivity, total dissolved solid (TDS), nitrate, sulphate, total suspended solid (TSS), total hardness (TH), iron, zinc, copper, lead, nickel, chromium and cadmium concentrations in the water samples were determined following American Public Health Association (APHA) procedure. Results showed that pH of 50 % of the wells were lower than minimum limit of 6.5 recommended by WHO. Sulphate, TH and iron in the water were significantly (p < 0.05) higher at residential area than industrial area. Electrical conductivity exhibited significant (p < 0.01) correlation with TDS (r = 0.701**) and NO32- (r = 0.922**) at residential area. At the industrial area however, concentration of salts in water samples was highly associated with SO42- (r = 0.864**) and Cd (r = 0.587**). Across locations of groundwater, iron and lead were above allowable WHO limits in drinking water. Cadmium was also above drinking limit at location T4 of the residential area. Consumers of groundwater in the study area are prone to health related challenges of heavy metal toxicity.


he water quality analysis is an important aspect in understanding the behavior of water and what can they be used for. This study gives us a valuable information on the general properties of water quality parameters like pH, electrical conductivity, TDS, Bicarbonate, Sulfate, Nitrate, chloride etc. of the study area . Water samples were analyzed at the water quality lab. NIH, Roorkee for pH, electrical conductivity and total dissolved solids. The pH of water varied from 7.14 to 7.75. The electrical conductivity (EC) of sample falls from 620µS/cm to 2000µS/cm. The overall total dissolved solids in water of study area varied from 120mg/l to 900mg/l. Overall the range of the Chloride in water of the study area tend to falls between 13mg/l to 375mg/l. Sulfate of all the water samples that were collected from the study area have ranged from 28mg/l to 250mg .The range of the Bicarbonate of all the water samples varied from 320mg/l to 1051mg/l. The study area helps to know about water quality parameters and how to find their values by usingtwo methods : 1) titration method 2) instrumental method .It also helps us to apply these water quality parameters in ArcGis. It helps us to show the values of different parameters in different blocks ofambala for different years In this we have studied different blocks of ambala district Haryana .We have taken the samples from different places from the blocks and also samples are from wells, canal , rivers, ponds.


2015 ◽  
Vol 16 (SE) ◽  
pp. 395-403
Author(s):  
Abbas Ghaffari Habib ◽  
Seyed Hadi Khatami

In Bahar County (Iran), rivers are among the important sources of water for the agricultural sector. Therefore, this research evaluated the parameters of temperature, pH, Total Dissolved Solids (TDS), turbidity, nitrate, total phosphate, dissolved oxygen (DO), Biological Oxygen Demand (BOD5), and fecal coliform at five stations for five months (from February 2015 to June 2015) to determine water quality in the rivers. Based on this evaluation, the NSFWQI index was calculated and, finally, the routes of the rivers were zoned. The best water quality was recorded at Station Number 3 with the NSFWQI Value of 80 in January, and the worst at Station Number 5 (latgah) with the NSFWQI Value of 37 in June. Based on the mean NSFWQI indices, water quality was Medium at Stations Number 1, 2, and 4, good at Station Number 3, and bad at Station number 5.


Sign in / Sign up

Export Citation Format

Share Document