scholarly journals Apical extrusion of bacteria following the use of reciprocating single-file and rotary multi-file instrumentation systems in oval root canals

2020 ◽  
Vol 23 (4) ◽  
pp. 8p
Author(s):  
Safa Kurnaz ◽  
Irem Bag ◽  
Aysel Gulbandilar

Objective: All instrumentation techniques and instruments are associated with apical extrusion during chemomechanical preparation, and this causes postoperative pain and flare-up. However, it is controversial whether reciprocal systems or rotary systems cause more apical extrusion. The objective of this in vitro study was to determine the differences in the amounts of apically extruded bacteria (AEB) associated with nickel-titanium rotary and reciprocating systems when used in oval-shaped root canals. Material and Methods: Seventy human mandibular premolar teeth with oval-shaped canals were randomly assigned to four experimental groups (15 teeth in each group) and one control group (10 teeth). The root canals were contaminated with Enterococcus faecalis and instrumented using two full-sequence rotary instruments (ProTaper Universal [PTU] and ProTaper Next [PTN]) and two reciprocating single-file instruments (Reciproc [R] and WaveOne [WO]). A 0.9% NaCl solution was used as an irrigant, and the bacterial extrusion was quantified as the number of colony-forming units for each sample. The results were statistically analyzed using the Kruskal-Wallis one-way analysis of variance and the Mann-Whitney U test, and the statistical significance level was set at p <0.05. Results: The R system was associated with the highest amount of bacterial extrusion (p <0.05). The PTU system caused more bacterial extrusion than the PTN and WO systems (p <0.05). There was no significant difference between the PTN and WO systems (p >0.05). Conclusions: All instrumentation techniques caused apical bacterial extrusion. The instrument design and preparation techniques affect the number of extruded bacteria.KEYWORDS Apical extrusion; Bacteria; Endodontics; Root canal preparation.

2011 ◽  
Vol 01 (04) ◽  
pp. 27-32
Author(s):  
Mithra N. Hegde ◽  
Snehal Thatte

Abstract Objectives: The objective of this study is to compare the amount of extrusion of bacteria beyond the apical foramen after instrumentation with Crown down and Step-back techniques using a manual and engine driven nickel-titanium instruments Materials and Methods: Seventy-five mandibular premolars with similar dimensions were used for the study. Access cavities prepared and root canals contaminated with a suspension of Enterococcus faecalis. The contaminated teeth were then divided into three experimental groups. Group 1(Crowndown group) divided into two: Group 1–A Hand files: root canals were instrumented using K-files and Group 1B – Rotary files: root canals were instrumented using ProTaper instruments. Group II (Step-back group) divided into two: Group II A– Hand files: root canals were instrumented using K-files and group II B–Rotary files: the root canals were instrumented using Light Speed LSX instruments. Group III (control group): no instrumentation was done.Bacteria were extruded after preparation were collected into vials, microbiological samples were incubated in culture media for 24hrs. The CFUs were determined for each sample. The data obtained was analyzed using the Kruskal-Wallis one way analysis of variance and Mann-Whitney U-tests. Result: There was a significant difference in the amount of bacteria extruded by both Crowndown and Step-back. The Step- back hand method extruded significantly more bacteria when compared with Crowndown hand technique. Conclusion: All instrumentation techniques extruded intracanal bacteria apically. There was a significant difference in both the engine driven instrumentation techniques, while the hand instrumentation by Step-back extruded more bacteria.


2021 ◽  
Vol 58 (1) ◽  
pp. eUJ3657
Author(s):  
Germano Brandão ◽  
◽  
Liliana Ávila Maltagliati ◽  
Ana Carla Raphaelli Nahás-Scocate ◽  
Murilo Matias ◽  
...  

The objective of this in vitro study was to assess and compare the shear bond strength of conventional and modified orthodontic tubes bonded to the surface of dry and saliva-contaminated enamel. The sample consisted of 40 human teeth, which were randomly divided into four groups according to attachment base and presence or absence of saliva contamination as follows: Group CB, conventional orthodontic tubes without salivary contamination; Group CB-S, conventional orthodontic tubes with salivary contamination; Groups BM, orthodontic tubes modified by welding a metal mesh to their base without salivary contamination; and Group BM-S, modified orthodontic tubes with salivary contamination. Shear bond strength test was performed in a universal testing machine and analysis of the adhesive remnant index (ARI) by optical microscopy. Two-way ANOVA was used, followed by Tukey’s test at a statistical significance level of 5%. The ARI results were analysed descriptively. There was statistically significant difference between the groups regarding the shear bond strength values, with conventional tubes presenting significantly higher values (P < 0.05). In addition, the presence of salivary contamination interfered negatively with the behaviour of conventional tubes only (P < 0.05). Shear bond strength was not improved by increasing the area of the orthodontic tubes. Moreover, salivary contamination influenced negatively the SBS values, but only when conventional tubes were used.


2008 ◽  
Vol 02 (04) ◽  
pp. 233-239 ◽  
Author(s):  
Alper Kustarci ◽  
Neslihan Akdemir ◽  
Seyda Herguner Siso ◽  
Demet Altunbas

ABSTRACTObjectives: The purpose of this study was to compare in-vitro the amount of debris extruded apically from extracted teeth, using K3, Protaper rotary instruments and manual step-back technique.Methods: Forty five human single-rooted mandibular premolar teeth were randomly divided into 3 groups. The teeth in 3 groups were instrumented until reaching the working length with K3, Protaper rotary instruments and K-type stainless steel instruments with manual step-back technique, respectively. Debris extruded from the apical foramen was collected into centrifuge tubes and the amount was determined. The data obtained were analyzed using Kruskal-Wallis one-way analysis of variance and Mann-Whitney U tests, with P=.05 as the level for statistical significance.Results: Statistically significant difference was observed between K3, Protaper and step-back groups in terms of debris extrusion (P<.05). Step-back group had the highest mean debris weight, which was significantly different from the K3 and Protaper groups (P<.05). The lowest mean debris weight was related to K3 group, which was significantly different from the Protaper group (P<.05).Conclusions: Based on the results, all instrumentation techniques produced debris extrusion. The engine-driven Ni-Ti systems extruded significantly less apical debris than step-back technique. However, Protaper rotary instruments extruded significantly more debris than K3 rotary instruments. (Eur J Dent 2008;2:233-239)


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Ensieh Grayli ◽  
Abbas Dashtban ◽  
Leyla Shadan ◽  
Naser Behnampour ◽  
Elham Afshari

Abstract Background Endodontically treated immature teeth which are restored with cast metal posts are of the most susceptible teeth to fracture. An apical plug is usually used as root end filling in order to seal the wide apical foramen. The current study was performed to evaluate the effect of different apical plug materials (MTA and Calcium enriched mixture cement) at varied thicknesses on fracture resistance of teeth restored with cast metal posts. Methods A total of 40 extracted intact single-rooted human mandibular premolars (removed for orthodontic reasons) were used in the study. The coronal part of each tooth was removed and root canal preparation was performed. A size 4 Gates Glidden drill was used to enlarge the canal and was passed through the apical foramen in order to simulate an immature apex. Samples were randomly divided into 5 groups (n = 8) according to apical plug (control group: No plug, group MTA5: 5 mm MTA plug, group CEM5: 5 mm CEM plug, group MTA3: 3 mm MTA plug, group CEM3: 3 mm CEM plug). Post-space preparations were performed and cast metal post-and-cores were fabricated and cemented. Fracture resistance was assessed using a universal testing machine. Fracture thresholds were recorded and data were analyzed using One-way ANOVA and Dunnett’s T3 tests with significance level at P value < 0.05. Results The analysis showed a significant difference of fracture resistance between groups (P value < 0.05). The mean fracture resistance of samples in control group was significantly lower than MTA5 (P value = 0.003). There was no significant difference between other groups (P value > 0.05). Conclusions Within the limits of this study, the evidence indicated that placement of a 5 mm MTA apical plug increased the fracture resistance in simulated immature teeth which are restored with cast metal posts, compared to control group (gutta-percha and sealer). While the results were not as promising for a 3 mm MTA apical plug or either 3 or 5 mm CEM apical plug.


2021 ◽  
Vol 15 (1) ◽  
pp. 30-34
Author(s):  
Neslihan Yılmaz Çırakoglu ◽  
Yağız Özbay

Background. This research aimed to investigate and compare the amount of apically extruded debris after root canal preparation using ProTaper Next, ProTaper Gold, and TruNatomy systems. Methods. Forty-five extracted mandibular premolar teeth with single canals with similar lengths were used. The root canals were prepared using ProTaper Next (Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Gold (Dentsply Maillefer, Ballaigues, Switzerland), or TruNatomy (Dentsply Maillefer, Ballaigues, Switzerland) files. Apically extruded debris during preparation was gathered into preweighed Eppendorf tubes. Then the Eppendorf tubes were incubated at 70°C for five days. The Eppendorf tubes were weighed again to determine their final weight plus the extruded debris. Results. The TRN system resulted in significantly less debris extrusion than the PTN system (P<0.05). There was no significant difference between the PTN and PTG groups and between the PTG and TRN groups (P>0.05). Conclusion. All the instrumentation systems caused apical extrusion of debris. However, the TRN system resulted in significantly less debris extrusion than the other systems.


Author(s):  
Rathika Rai ◽  
M. A. Easwaran ◽  
K. T. Dhivya

Aim: To evaluate the surface detail reproduction of dental stone this is immersed in different disinfectant solution and studied under stereomicroscope. Methodology: Total number of 30 specimens of dental stone (Type III) were made with measurements of 1.5cm diameter and 1cm height .This samples are divided in to 3 groups group A,B,C. were A is immersed in Distilled water which was taken as control group ;B is immersed in 2% Glutaraldehyde and C is immersed in 5%sodium hypochlorite. Each specimen were immersed in the disinfectant solution for 15 minutes and dried under room temperature for 24 hrs. After 24 hrs each specimens are studied under stereomicroscope for surface details. Result: The results showed no significant difference in the surface irregularities and porosities for a group 1 and group 2 except group 3 which showed significant increase in the porosities, surface irregularities and erosions after disinfection with 5% NaHOCl by immersion method. Conclusion: The surface detail reproduction capacity of die stone was adversely affected when 5% Sodium hypochlorite was used as disinfectant solution when compare d to control group and 2% Glutaraldehyde


2015 ◽  
Vol 85 (6) ◽  
pp. 920-926 ◽  
Author(s):  
Ricardo Carvalho Bueno ◽  
Roberta Tarkany Basting

ABSTRACT Objective:  To evaluate the proliferation and morphology of human osteoblasts cultured on two brands of mini-implants after 24, 48, and 72 hours, in addition to the chemical composition found on their surface. Materials and Methods:  Two brands of mini-implant (Morelli and Neodent) were evaluated; polystyrene was used as a control group (n  =  3). Osteoblasts were cultured on the surface of sterilized mini-implants in a CO2 incubator at different time periods (24, 48, and 72 hours). Osteoblast proliferation was quantified by scanning electron microscopy using up to 5000× magnification, and cell morphology was analyzed by a single observer. For the chemical analysis, spectroscopy X-ray fluorescence was used to identify and quantify chemical components on the surface of the mini-implants. Results:  Two-way ANOVA showed no significant interaction between the factors studied (P  =  0.686). A Tukey test revealed no significant difference in osteoblast proliferation between the mini-implants at all studied periods; however, a difference in cell proliferation was detected between the Neodent and the control group (P  =  .025). For all groups, time had a direct and positive effect on osteoblast proliferation (P &lt; .001). The significant elements present in both brands of mini-implants were titanium, aluminum, vanadium, and iron. Conclusions:  Osteoblast proliferation was present on the mini-implants studied, which increased over time; however, no significant difference between brands was observed. No difference was seen between the mini-implants evaluated in terms of chemical composition. Cell adhesion after 72 hours suggests that areas of bone remodeling can be achieved, thus initiating the process of mini-implant anchorage.


2012 ◽  
Vol 2012 ◽  
pp. 1-5 ◽  
Author(s):  
Blerim Kamberi ◽  
Donika Bajrami ◽  
Miranda Stavileci ◽  
Shuhreta Omeragiq ◽  
Fatmir Dragidella ◽  
...  

Aim. The purpose of this in vitro study was to assess the antimicrobial efficacy of Biopure MTAD against E. faecalis in contaminated root canals. Materials and Methods. Forty-two single rooted extracted human teeth were inoculated with E. faecalis and incubated for four weeks. The samples were divided in two control and five experimental groups irrigated with 1.5% sodium hypochlorite solution (NaOCl); 3% NaOCl; BioPure MTAD; 1.5% NaOCl/17% EDTA; or 3% NaOCl/17% EDTA. After a one-week incubation, complete disinfection was confirmed by the absence of turbidity in the incubation media. Dentin shavings were taken from samples with no turbidity to verify whether E. faecalis was present in dentin tubules. Results were analyzed statistically using Fisher's exact test, with the level of significance set at . Results. Statistical analysis of the data obtained at Day 7 and after dentin shaving analysis showed that BioPure MTAD had significantly greater antibacterial activity than 1.5% NaOCl, 1.5% NaOCl/17% EDTA and 3% NaOCl/17% EDTA. No significant difference was detected between MTAD and 3% NaOCl. Conclusions. These findings suggest that BioPure MTAD possesses superior bactericidal activity compared with NaOCl and EDTA against E. faecalis.


2020 ◽  
Vol 11 (2) ◽  
pp. 160-166
Author(s):  
Mohammad Javad Moghaddas ◽  
Horieh Moosavi ◽  
Sara Yaghoubirad ◽  
Nasim Chiniforush

Introduction: The purpose of this study was to compare the effect of the bioactive glass, the glass ionomer, and the Erbium YAG laser as liners on the remineralization of the affected dentin. Methods: The present study was conducted on 64 healthy extracted human molars divided into 4 groups, 1 control group and 3 experimental groups. After artificially inducing dentinal caries lesions, each of the experimental groups was applied to the cavity floor and then restored with a composite. The samples were stored after thermocycling in an incubator for two months. Finally, the hardness of the cavity floor was measured at 3 depths of 20, 50 and 100 μm by the Vickers microhardness tester. The dentin conditions underneath the liners were also evaluated with FESEM. Statistical analysis was performed by two-way ANOVA and the post-hoc Games-Howell test (P<0.05). Results: Among the groups, the lowest microhardness value was in the control group (P<0.05) except at a depth of 100 μm; therefore, there was no significant difference between the control group and the bioactive glass (P>0.05). The laser group had the highest microhardness value, which was significantly different from the control group (P<0.05). There was a significant difference between the laser and bioactive glass (P<0.05), except at a depth of 20 μm. The laser and glass ionomer had only a significant difference at a depth of 100 μm (P<0.05). The microhardness value induced by glass ionomer was higher than bioactive glass, which in no depth was significant (P>0.05). Partial dentinal tubule occlusion was observed with FESEM in each of the experimental groups as compared to the control group. Conclusion: The microhardness values were higher in all groups than in the control group. The laser might be more successful in remineralization than the other ones.


2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Francesca Cattoni ◽  
Giulia Teté ◽  
Alessandro Mauro Calloni ◽  
Fabio Manazza ◽  
Giorgio Gastaldi ◽  
...  

Abstract Background Aesthetic porcelain veneers proved to be a long-term reliable prosthetic solution, ensuring minimal invasiveness. The use of veneers requires an adhesive cementation technique, so maintaining as much enamel as possible is to ensure lasting success. A diagnostic mock-up is a key tool that allows a preview of the outcome of the aesthetic restoration: it is obtainable both in an analog and digital way. With the recent developments in impression technology and the ever so fast growing use of CAD-CAM technologies it is useful to understand the pros and cons of either one of these techniques (analog and digital) in order to identify the easier and more convenient workflow in aesthetic dentistry. Methods After taking pictures and impressions of the dental arcs of a patient in need of aesthetic rehabilitation, 52 resin models were produced and a digital drawing of the smile was outlined. Both an analog and a digital wax-up were obtained from two of the 52 models: the latter was obtained using digital impressions and a dedicated software. The analog wax-up was then used to produce 25 matrices that have later been used to mould 25 resin mock-ups using a traditional moulding protocol (Control Group - CG). The digital wax-up was used to mill 25 PMMA mock-ups. Each mock-up, both milled and moulded (total 50), was then laid on the other 50 resin models as a digital impression of it was taken. The STL. files of the milled mock-ups were compared with the 3D CAD wax-up made using a specific software. The STL. files of the analog printed mock-ups were compared with the traditional wax-up design. A statistical analysis was carried out to evaluate the difference between the groups. Results The statistical analysis showed a significant difference (P > 0.01) between the mean value of the distance between the points of the overlapping STL. meshes in GC (0.0468 mm) and in TG (Test Group - TG) (0,0109 mm). Conclusions The study showed a difference in accuracy between traditional moulded and milled mock-ups compared to their original wax-up. The data analysis reports that the digital method allows for greater accuracy. Within the limitations of this study, a fully digital workflow is to considered more reliable when it come to creating an esthetic mockup: the digital procedure has been shown to be more accurate than the one made manually which is much more operator dependent and it brings an increase to the chance of error, and that could ultimately affect the final result.