Histomorphometric Evaluation of Six Dental Implant Surfaces After Early Loading in Augmented Human Sinuses

10.1563/812.1 ◽  
2006 ◽  
Vol 32 (4) ◽  
pp. 153-166 ◽  
Author(s):  
Marzio Todisco ◽  
Paolo Trisi

Abstract This study investigated the bone-to-implant contact (BIC) and osteoconductive capacity (OC) of 6 different implant surfaces after early loading in humans. Two implants with different surfaces were placed side-by-side in the grafted (n = 5) and nongrafted (n = 1) sinuses of 3 volunteers. Single-tooth restorations were delivered 60 days later. After 6 months of full occlusal loading, implants were retrieved in block sections for histomorphometric analysis. One implant (acid etched) placed in grafted bone failed when loaded. There were no other complications. In grafted bone, the microtextured surface achieved the highest BIC value (94.08%), followed by the oxidized (77.32%), hydroxyapatite (HA) (74.51%), sandblasted and acid-etched (51.85%), and titanium plasma-sprayed (TPS) (41.48%) surfaces. In native bone, the acid-etched surface achieved a higher BIC value (69.03%) than the HA surface (59.03%). The highest OC value in grafted bone was exhibited by the microtextured surface (34.31%), followed by the HA (28.62%), sandblasted and acid-etched (25.08%), oxidized (17.55%), and TPS (−20.47%) surfaces. The HA surface exhibited a higher OC value (30.39%) in native bone compared with the acid-etched surface (24.0%). As a whole, highest BIC and OC values were exhibited by the microtextured surface, and lowest values were exhibited by the TPS surface. All other surfaces demonstrated excellent BIC (>50%) but varied in OC (range = 17.55%–28.62%). These findings are tempered by the limited scope and sample size of the study and should be considered preliminary. More research is needed to determine the impact of implant surface texture on BIC and OC.

2010 ◽  
Vol 36 (2) ◽  
pp. 85-90 ◽  
Author(s):  
Susana d'Avila ◽  
Leonardo Delfino dos Reis ◽  
Adriano Piattelli ◽  
Kelly C. S. Aguiar ◽  
Marcelo de Faveri ◽  
...  

Abstract Smoking has adverse effects on peri-implant bone healing and can cause bone loss around successfully integrated implants placed on type IV bone. This study evaluated the influence of implant surface topography of microimplants retrieved from posterior maxilla of smokers after 2 months of unloaded healing. Seven partially edentulous patients received 2 microimplants (machined and sandblasted acid-etched surface) each during conventional implant surgery. Histometric evaluation showed that the mean bone to implant contact was 10.40 ± 14.16% and 22.19 ± 14.68% to machined and sandblasted acid-etched surfaces, respectively (P < .001). These data suggest that the sandblasted acid-etched surface presented better results than the machined surface after a short healing time in smokers.


Materials ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 1830
Author(s):  
Mastrangelo Filiberto ◽  
Botticelli Daniele ◽  
Bengazi Franco ◽  
Scarano Antonio ◽  
Piattelli Adriano ◽  
...  

Objective: Evaluation of the in vivo bone response of two innovative titanium surfaces ytterbium laser active fiber obtained (L1-L2) compared to a sandblasted and acid etched (SBAE) during early phase of osseointegration. Material and Methods: Three implant groups with the same macroscopic features were obtained (L1-L2-SBAE) to promote specific surface characteristics. Scanning electron microscopy, profilometric evaluation, X-ray spectrometry, and diffraction analysis were performed. For each group, six implants were placed in the tibiae of three Peli Buey sheep, and histologic, histomorphometric analysis, bone to implant contact (BIC), and the Dynamic Osseointegration index (DOI) were performed. Results: During the early phases of osseointegration, the histological and histomorphometric results showed significant differences between L1-L2-SBAE implants. At 15 and 30 days, histological analysis detected a newly bone formation around all specimens with an higher vital bone in L2 compared to L1 and SBAE both in cortical and in poor-quality marrow bone. At same time, histomorphometric analysis showed significantly higher BIC values in L2 (42.1 ± 2.6 and 82.4 ± 2.2) compared to L1 (5.2 ± 3.1 and 56.2 ± 1.3) and SBAE (23.3 ± 3.9 and 77.3 ± 0.4). DOI medium value showed a higher rate in L2 (2.83) compared to SBAE (2.60) and L1 (1.91). Conclusions: With the limitations of this pilot study, it is possible to assess that the titanium surface characteristics, and not the technologies used to obtain the modification, played a crucial role during the osseointegration process. Histological, histomorphometric, BIC, and DOI evaluation showed a significantly higher rate in L2 specimens compared to others, confirming that the implant surface could increase the bone response in cortical or marrow poor quality bone during the initial phases of osseointegration.


2017 ◽  
Vol 28 (5) ◽  
pp. 559-565 ◽  
Author(s):  
Suelen Cristina Sartoretto ◽  
José de Albuquerque Calasans-Maia ◽  
Yanan Osório da Costa ◽  
Rafael Seabra Louro ◽  
José Mauro Granjeiro ◽  
...  

Abstract The objective of this study was to evaluate the early osseointegration of two different implants surfaces, a sandblasted and acid-etched surface (TN) compared with same geometry and surface roughness modified to be hydrophilic/wettable by conditioning in an isotonic solution of 0.9% sodium-chloride (TA) through histological and histomorphometric analysis after sheep tibia implantation. Forty dental implants, divided in two groups (TN and TA) were placed in the left tibia of twenty healthy, skeletally mature Santa Ines sheep (n=5/experimental period). After 7, 14, 21 and 28 days post-implantation, the samples were removed and the sheep were kept alive. Analysis of resin sections (30 μm) allowed the quantification of bone area (BA) and bone-to-implant contact (BIC). TA group presented nearly 50% increase in BA at 14 days (p<0.001, ANOVA - Tukey’s post test) compared with 7 days. The TA presented higher values than the TN for BA and BIC at 14, 21, and 28 days after placement, stabilizing bone healing. TA hydrophilic surface promoted early osseointegration at 14 and 21 days compared to TN, accelerating bone healing period post-implant placement in sheep tibia.


2021 ◽  
Vol 10 (8) ◽  
pp. 1641
Author(s):  
Stefanie Kligman ◽  
Zhi Ren ◽  
Chun-Hsi Chung ◽  
Michael Angelo Perillo ◽  
Yu-Cheng Chang ◽  
...  

Implant surface design has evolved to meet oral rehabilitation challenges in both healthy and compromised bone. For example, to conquer the most common dental implant-related complications, peri-implantitis, and subsequent implant loss, implant surfaces have been modified to introduce desired properties to a dental implant and thus increase the implant success rate and expand their indications. Until now, a diversity of implant surface modifications, including different physical, chemical, and biological techniques, have been applied to a broad range of materials, such as titanium, zirconia, and polyether ether ketone, to achieve these goals. Ideal modifications enhance the interaction between the implant’s surface and its surrounding bone which will facilitate osseointegration while minimizing the bacterial colonization to reduce the risk of biofilm formation. This review article aims to comprehensively discuss currently available implant surface modifications commonly used in implantology in terms of their impact on osseointegration and biofilm formation, which is critical for clinicians to choose the most suitable materials to improve the success and survival of implantation.


2020 ◽  
Vol 61 (6) ◽  
pp. 177-187
Author(s):  
Till Kämmerer ◽  
Tony Lesmeister ◽  
Victor Palarie ◽  
Eik Schiegnitz ◽  
Andrea Schröter ◽  
...  

Introduction: We aimed to compare implant osseointegration with calcium phosphate (CaP) surfaces and rough subtractive-treated sandblasted/acid etched surfaces (SA) in an in vivo minipig mandible model. Materials and Methods: A total of 36 cylindrical press-fit implants with two different surfaces (CaP, n = 18; SA, n = 18) were inserted bilaterally into the mandible of 9 adult female minipigs. After 2, 4, and 8 weeks, we analyzed the cortical bone-to-implant contact (cBIC; %) and area coverage of bone-to-implant contact within representative bone chambers (aBIC; %). Results: After 2 weeks, CaP implants showed no significant increase in cBIC and aBIC compared to SA (cBIC: mean 38 ± 5 vs. 16 ± 11%; aBIC: mean 21 ± 1 vs. 6 ± 9%). Two CaP implants failed to achieve osseointegration. After 4 weeks, no statistical difference between CaP and SA was seen for cBIC (mean 54 ± 15 vs. 43 ± 16%) and aBIC (mean 43 ± 28 vs. 32 ± 6). However, we excluded two implants in each group due to failure of osseointegration. After 8 weeks, we observed no significant intergroup differences (cBIC: 18 ± 9 vs. 18 ± 20%; aBIC: 13 ± 8 vs. 16 ± 9%). Again, three CaP implants and two SA implants had to be excluded due to failure of osseointegration. Conclusion: Due to multiple implant losses, we cannot recommend the oral mandibular minipig in vivo model for future endosseous implant research. Considering the higher rate of osseointegration failure, CaP coatings may provide an alternative to common subtractive implant surface modifications in the early phase post-insertion.


Author(s):  
Sigmar Kopp ◽  
Mareike Warkentin ◽  
Ferenc Öri ◽  
Peter Ottl ◽  
Günther Kundt ◽  
...  

AbstractThis study was designed to determine and statistically analyze bone-to-implant contact (BIC) values for human specimens segmented in at least two different locations.Samples of human bone with fractured osseointegrated implants were obtained from six patients. Sections were prepared, dehydrated, and resin infiltrated. Undecalcified bone sections were produced using the thin-section technique according to Donath, ultimately obtaining a section thickness of approximately 20 μm. Fifteen specimens were available for histomorphometry. The bone sections were digitized and analyzed. The bone-to-metal contact (BMC) parameter was determined histomorphometrically. The BMC was returned in terms of the visibly bone-covered implant surfaces as a percentage of the total implant surface shown.The values obtained for the six implants were arranged as six maximum-distance pairs and tested for significance using the t-test for dependent samples. The mean difference in BIC was 11.69±9.79%. The two-sided test showed a significant difference (p=0.033).The accidental or deliberate choice of section plane for a bone-implant block has an influence on the BIC value. To make BIC values more comparable, a standardization of section planes is desirable.


2021 ◽  
Vol 9 (2) ◽  
pp. 428
Author(s):  
María Carmen Sánchez ◽  
Andrea Alonso-Español ◽  
Honorato Ribeiro-Vidal ◽  
Bettina Alonso ◽  
David Herrera ◽  
...  

Microbial biofilm modeling has improved in sophistication and scope, although only a limited number of standardized protocols are available. This review presents an example of a biofilm model, along with its evolution and application in studying periodontal and peri-implant diseases. In 2011, the ETEP (Etiology and Therapy of Periodontal and Peri-Implant Diseases) research group at the University Complutense of Madrid developed an in vitro biofilm static model using representative bacteria from the subgingival microbiota, demonstrating a pattern of bacterial colonization and maturation similar to in vivo subgingival biofilms. When the model and its methodology were standardized, the ETEP research group employed the validated in vitro biofilm model for testing in different applications. The evolution of this model is described in this manuscript, from the mere observation of biofilm growth and maturation on static models on hydroxyapatite or titanium discs, to the evaluation of the impact of dental implant surface composition and micro-structure using the dynamic biofilm model. This evolution was based on reproducing the ideal microenvironmental conditions for bacterial growth within a bioreactor and reaching the target surfaces using the fluid dynamics mimicking the salivary flow. The development of this relevant biofilm model has become a powerful tool to study the essential processes that regulate the formation and maturation of these important microbial communities, as well as their behavior when exposed to different antimicrobial compounds.


Author(s):  
P. Gougeon ◽  
C. Moreau

Abstract In thermal spray processes, the coating structure is the result of flattening and cooling of molten droplets on the substrate. The study of the cooling time and evolution of the splat size during impact is then of the highest importance to understand the influence of the spray parameters and substrate characteristics on the coating structure. Measurement of particle temperature during impact requires the use of a high-speed 2-color pyrometer to collect the thermal emission of the particle during flattening. Simultaneous measurement of the splat size with this pyrometer is difficult since the size of the particle can change as it cools down. To measure the splat size independently, a new measurement technique has been developed. In this technique the splat size is measured from the attenuation of the radiation of a laser beam illuminating the particle during impact. Results are presented for plasma sprayed molybdenum particles impacting on a glass substrate at room temperature. It is shown that the molybdenum splat reaches its maximum extent about 2 microseconds after the impact. In this work, we show that this increase of the splat surface is followed by a phase during which the splat size decreases significantly during 2 to 3 microseconds.


Author(s):  
J. Eric Oliver ◽  
Shang E. Ha ◽  
Zachary Callen

This chapter considers the types of people who run for office and the types of campaigns they run. It examines the impact of factors such as personal ambition, civic responsibility, mobilizing issues, personal gain, and political indignation by looking at a large sample of local politicians (i.e., unsuccessful candidates and elected officials) from the greater Chicago metropolitan area. The small size, limited scope, and low bias of most Chicago-area municipal governments mean that these local politicians, like local voters, tend to be stakeholders in their communities. They are very concerned with issues of economic development and quality of life, yet are drawn into public affairs primarily from a sense of civic duty and an attachment to their towns. They are motivated less by ideology, partisanship, or even personal ambition, than by a public-spirited commitment to sustaining the quality of their communities.


Sign in / Sign up

Export Citation Format

Share Document