scholarly journals Insights from the Engineering Geological Mapping of Four Basement Rocks Derived Soils

2018 ◽  
Vol 2 ◽  
pp. 16-34 ◽  
Author(s):  
Oluwaseun Franklin Olabode ◽  
Yinusa Ayodele Asiwaju-Bello

Due to the rapid expansion and associated construction of civil engineering structures on the Federal University of Technology, Akure (FUTA) campus, there arose an urgent need for an engineering geological mapping of the underlying soils (residual soils). Generalized geological mapping revealed four types of basement rocks namely migmatite-gneisses, granites, quartzites and charnockites. Results from the fifty (50) soil samples from twenty-five test pits collected all over the spread of the campus coverage of 6.4 km2revealed that the campus is underlain by soils of granular and clayey composition, generally lateritic, having reddish to brownish colour. Engineering geological tests such as natural moisture content, particle size analysis, consistency limits, California bearing ratio and consolidation were carried out on the soils following standard procedures revealed that the values of natural moisture content do not generally follow a consistent pattern and varied from location to location. The grain size characteristics curve, displayed 84% and 16% subsoils are of well graded and poorly graded type respectively. The soils were grouped into CL (low plasticity), CI (medium plasticity) and CH (high plasticity) from consistency limits results. Compaction characteristics of the subsoils revealed 36% and 64% representative of fair to good and poor to very poor foundation materials respectively. Soils with settlement rates greater than 1mm/year were designated as high settlement subsoils. 72% and 28% of the subsoils fell into hard to stiff and soft categories from the shear strength characteristics respectively, and classified as c-ø soils. California Bearing Ratios values range from 10 – 70, indicating their suitability for pavement construction. Conclusively, areas underlain by migmatite-gneiss and charnockite-derived soils, and granite and quartzite-derived soils possessed low and high strength characteristics respectively which can be attributed to their textural characteristics. The subsoils of the entire campus spread are however capable of bearing very substantial loads.

Geosciences ◽  
2020 ◽  
Vol 10 (3) ◽  
pp. 94
Author(s):  
Alemineh Sorsa ◽  
Sanjaya Senadheera ◽  
Yoseph Birru

Soils are naturally occurring materials that carry loads of civil engineering structures including roads and buildings. However, not all natural soils are suitable for such uses due to limited strength and instability under varying environmental conditions. A lack of adequate geotechnical investigations and soil characterization can result in the over-design of foundations, unexpected excavations to remove unsuitable soils, cost overruns, construction delays; and, contract disputes. In this research, an experimental plan was executed to determine the engineering properties of subgrade soil in Jimma Town in southwestern Ethiopia by using both disturbed and undisturbed soil samples. The plan included tests to determine the moisture content, specific gravity, grain-size analysis, Atterberg limits, compaction-density relationship, California Bearing Ratio (CBR), unconfined compression strength, and triaxial shear strength. X-ray diffraction (XRD) analysis was also conducted to determine the chemical composition of the soil. The soil characterization indicated that soft clay is the predominant subgrade soil type and that it has a very low load-bearing capacity, high plasticity, low strength and, high compressibility, which makes the soil unsuitable to serve as a highway subgrade without the help of soil improvement techniques.


2020 ◽  
Vol 1 (12) ◽  
pp. 36-39
Author(s):  
L. V. Iyashvili ◽  
Yu. A. Vinnichenko ◽  
A. V. Vinnichenko

The purpose of the study is a quantitative assessment of the yield of dentinal fluid on the surface of the treated dentin of the tooth when restoring its structure with a composite filling material. To achieve this goal, digital images of the coronal parts of the teeth having formed carious cavities were used; virtual models of hard tissues of teeth recreated using specialized computer programs; A computer program that provides the ability to accurately determine the area of the treated dentin tooth. The results made it possible to draw the following conclusions: with an increase in the depth of the carious cavity, the amount of dentin fluid that can stand out on its surface (1–2 mm from the tooth cavity) sharply increases; with an increase in the area of the formed carious cavity (more than 30 mm2), the risk of release of a critical mass of dentinal fluid (more than 0.4 mg), which can adversely affect the strength of the adhesive interaction between the composite material and the hard tissues of the tooth, increases significantly; the same dynamics is observed with increasing time, at which there is the possibility of free exit of dentinal fluid to the surface of the cavity prepared for filling (more than 45 seconds).


Molecules ◽  
2021 ◽  
Vol 26 (7) ◽  
pp. 2008
Author(s):  
Samsul Rizal ◽  
N. I. Saharudin ◽  
N. G. Olaiya ◽  
H. P. S. Abdul Khalil ◽  
M. K. Mohamad Haafiz ◽  
...  

The degradation and mechanical properties of potential polymeric materials used for green manufacturing are significant determinants. In this study, cellulose nanofibre was prepared from Schizostachyum brachycladum bamboo and used as reinforcement in the PLA/chitosan matrix using melt extrusion and compression moulding method. The cellulose nanofibre(CNF) was isolated using supercritical carbon dioxide and high-pressure homogenisation. The isolated CNF was characterised with transmission electron microscopy (TEM), FT-IR, zeta potential and particle size analysis. The mechanical, physical, and degradation properties of the resulting biocomposite were studied with moisture content, density, thickness swelling, tensile, flexural, scanning electron microscopy, thermogravimetry, and biodegradability analysis. The TEM, FT-IR, and particle size results showed successful isolation of cellulose nanofibre using this method. The result showed that the physical, mechanical, and degradation properties of PLA/chitosan/CNF biocomposite were significantly enhanced with cellulose nanofibre. The density, thickness swelling, and moisture content increased with the addition of CNF. Also, tensile strength and modulus; flexural strength and modulus increased; while the elongation reduced. The carbon residue from the thermal degradation and the glass transition temperature of the PLA/chitosan/CNF biocomposite was observed to increase with the addition of CNF. The result showed that the biocomposite has potential for green and sustainable industrial application.


2015 ◽  
Vol 773-774 ◽  
pp. 1438-1442 ◽  
Author(s):  
Siti Aimi Nadia Mohd Yusoff ◽  
I. Bakar ◽  
Devapriya Chitral Wijeyesekera ◽  
Adnan Zainorabidin ◽  
Aziman Madun

This paper compares some geotechnical properties of Kaolin, Laterite and Peat. Laterite was collected from Bukit Banang while Peat sample was collected from Parit Nipah, both locations were in Batu Pahat, Johor. Meanwhile, kaolin that was used in this research was manufactured kaolin. These soil samples were subjected to routine laboratory analysis and resulting data were analyzed statistically using a correlation analysis. A laboratory testing program consists of “Basic properties test” to obtain general information on the materials (e.g Natural moisture content, Atterberg Limit, Specific gravity, grain size analysis, chemical composition and pH) and “Geotechnical properties tests” to measure specific properties that characterize soil behaviour for design and constructability assessments (e.g Standard Proctor Test, Unconfined Compressive Strength and CBR).The results showed that the Natural/initial moisture content for laterite, peat and kaolin is 22.54%, 480.61% and 0.22% respectively. Meanwhile Specific gravity for each soil was in the range 1.50-2.79.It was also found that the pH of all soil is acidic which lay in the range of 3.76-5.95.The UCS for the optimally compacted sample of laterite is 445.77 kPa, kaolin is 199.23 kPa and for peat is 58.70 kPa. This paper summarizes the result of analysis performed on all tests conducted. Based on the results, the geotechnical property of the soil is a highly dependent with the type of soil and therefore, determining the soil characterization and the soil strength should be considered during the planning phase of any earthwork construction operation.


2013 ◽  
Vol 1 (4) ◽  
pp. 3263-3304
Author(s):  
Y. Muceku ◽  
O. Korini

Abstract. This paper describes the landslides and slope stability evaluation in the urban area of Kruja town, Albania. Kruja is a~historical and heritage center, due to the existence of many important cultural monuments including Skanderbeg castle and Bazaar square etc. The urban area of Kruja town has been affected from the Landslides effects, in the past and also present. From this phenomenon many engineering objects such as buildings, roads etc. are damaged and demolished. From the engineering geological mapping at scale 1 : 5000 it is observed that many active landslides have dramatically increased in activity after 1980s. The landslide types found in the studied area are earth slides, debris flow, as well as rock fall and rock rolling. Also, from field works and laboratory analysis, the slope stability of whole urban areas has been determined; for this purpose the studied zone is divided into the stable and unstable areas, which helps to better understand the mass movement's activity as one of the most harmful hazards of the geodynamics' phenomena.


Sign in / Sign up

Export Citation Format

Share Document