Abstract
A test apparatus is designed to carry out dynamic and static fluid-loss tests of fracturing fluids. This test apparatus simulates the pressure difference, temperature, rate of shear, duration of shear, and fluid-flow pattern expected under fracture conditions.
For a typical crosslinked fracturing fluid, experimental results indicate that fluid loss values can be a function of temperature, pressure differential, rate of shear, and degree of non-Newtonian behavior of the fracturing fluid.
A mathematical development demonstrates that the fracturing-fluid coefficient and filter-cake coefficient can be obtained only if the individual pressure drops can be measured during a typical fluid-loss test.
Introduction
In a hydraulic fracturing treatment, the development of fracture length and width is strongly dependent on a number of key fluid and formation parameters. One of the most important of these parameters is the rate at which the fracturing fluid leaks, off into the created fracture faces. This parameter, identified as fluid loss, also influences the time required for the fracture to heal after the stimulation treatment has been terminated. This in turn will influence the final distribution of proppant in the fracture and will dictate when the well can be reopened and the cleanup process started. Historically, tests to measure fluid loss have been carried out primarily under what is characterized as static conditions. In such tests, the fracturing fluid is forced through filter paper or through a thin core wafer under a pressure gradient, and the flow rate at the effluent side is determined. Of course, the use of filter paper cannot account for reservoir formation permeability and porosity; therefore, the fluid-loss characteristics derived from such tests should be viewed as only gross approximations. The static core-wafer test on the other hand, reflects to some extent the interaction of the formation and fracturing-fluid properties. However, one important fluid property is altogether ignored in such static core-wafer tests. This is the effect of shear rate in the fracture on the rheology (viscosity) of fracturing fluid and subsequent effects of viscosity on the fluid loss through the formation rock.
In the past, several attempts were made to overcome the drawbacks of static core-wafer tests by adopting dynamic fluid-loss tests. Although these dynamic tests were a definite improvement over the static versions, each had drawbacks or limitations that could influence test results. In some of the studies, the shearing area was annular rather than planar as encountered in the fracture. In other cases, the fluid being tested did not experience a representative shear rate for a sufficiently long period of time. An additional problem arose because most studies were performed at moderate differential pressures and temperatures. The final drawback in several of the studies was that the fluid flow and leakoff patterns did not realistically simulate those occurring in the field.
In the first part of this paper, we emphasize the design of a dynamic fluid-loss test apparatus that possesses none of these drawbacks. In the second part of the paper, test results with this apparatus are presented for three different fluid systems. These systems areglycerol, a non-wall-building Newtonian fluid,a polymer gel solution that is slightly wall-building and non-Newtonian, anda crosslinked fracturing system that is highly non-Newtonian in nature and possesses the ability to build a wall (filter cake) on the fracture face (see Table 1).
The fluids were subjected to both static and dynamic test procedures. In the third part of the paper, results of experiments carried out with crosslinked fracturing fluid for different core lengths, pressure differences, temperatures, and shear rates are compared and the significance of the difference of fluid loss is emphasized.
Experimental Equipment and Procedure
The major components of the experimental apparatus shown in Fig. 1 are a fluid-loss cell, circulation pump, heat exchanger, system pressurization accumulators, and a fluid-loss recording device. The construction material throughout most of the system is 316 stainless steel. The fluid loss is measured through a cylindrical core sample, 1.5 in. [3.81 cm] in diameter, mounted in the fluid-loss cell. Heat-shrink tubing is fitted around the circumference of the core and a confining pressure is maintained to prevent channeling. Fracturing fluid is circulated through a rectangular channel across one end of the core.
SPEJ
P. 482^