scholarly journals Design and Development of Ram Pump

Author(s):  
Sammed Kothale

Due to A hydraulic ram (or water ram) pump is a simple, motorless device for pumping water at low flow rates. It uses the energy of flowing water to lift water from a stream, pond, or spring to an elevated storage tank or to a discharge point. It is suitable for use where small quantities of water are required and power supplies are limited, such as for household, garden, or livestock water supply. A hydraulic ram pump is useful where the water source flows constantly and the usable fall from the water source to the pump location is at least 3 feet.

2020 ◽  
Author(s):  
Daniel Madrzykowski ◽  
◽  
Nick Down

This study was designed to be an initial step to investigate the potential of low flow nozzles as part of a retrofit flashover prevention system in residential homes with limited water supplies. Not all homes have water supplies that can meet the needs of a residential sprinkler system. Current alter- natives, such as including a supplemental tank and pump, increase the cost of the system. These homes could benefit from an effective fire safety system with lower water supply requirements. The experiments in this study were conducted in a steel test structure which consisted of a fire room attached to a hallway in an L-shaped configuration. Three types of experiments were conducted to evaluate nozzles at different flow rates and under different fire conditions. The performance of the nozzles was compared to the performance of a commercially available residential sprinkler. The first set of experiments measured the distribution of the water spray from each of the nozzles and the sprinkler. The water spray measurements were made without the presence of a fire. The other two sets of experiments were fire experiments. The first set of fire experiments were designed to measure the ability of a water spray to cool a hot gas layer generated by a gas burner fire. The fire source was a propane burner which provided a steady and repeatable flow of heat into the test structure. Two water spray locations were examined, in the fire room and in the middle of the hallway. In each position, the burner was shielded from the water spray. The results showed that for equivalent conditions, the nozzle provided greater gas cooling than the sprinkler. The tests were conducted with a fire size of approximately 110 kW, and water flow rates in the range of 11 lpm (3 gpm) and 19 lpm (5 gpm). The second set of fire experiments used an upholstered sofa as the initial source of the fire with the water spray located in the same room. As a result of the compartment size and water spray distribution, the nozzle flowing water at 23 lpm (6 gpm) provided more effective suppression of the fire than the sprinkler flowing 34 lpm (9 gpm) did. The nozzle was similarly effective with the ignition location moved 1.0 m (3.2 ft) further away. However, the nozzle failed to suppress the fire with a reduced water flow rate of 11 lpm (3 gpm). The results of this limited study demonstrate the potential of low flow nozzles, directly flowing water on to the fuel surface, with the goal of preventing flashover. Additional research is needed to examine larger room sizes, fully furnished rooms, and shielded fires to determine the feasibility of a reduced water flow flashover prevention system.


ORL ◽  
2021 ◽  
pp. 1-5
Author(s):  
Jingjing Liu ◽  
Tengfang Chen ◽  
Zhenggang Lv ◽  
Dezhong Wu

<b><i>Introduction:</i></b> In China, nasal cannula oxygen therapy is typically humidified. However, it is difficult to decide whether to suspend nasal cannula oxygen inhalation after the nosebleed has temporarily stopped. Therefore, we conducted a preliminary investigation on whether the use of humidified nasal cannulas in our hospital increases the incidence of epistaxis. <b><i>Methods:</i></b> We conducted a survey of 176,058 inpatients in our hospital and other city branches of our hospital over the past 3 years and obtained information concerning their use of humidified nasal cannulas for oxygen inhalation, nonhumidified nasal cannulas, anticoagulant and antiplatelet drugs, and oxygen inhalation flow rates. This information was compared with the data collected at consultation for epistaxis during these 3 years. <b><i>Results:</i></b> No significant difference was found between inpatients with humidified nasal cannulas and those without nasal cannula oxygen therapy in the incidence of consultations due to epistaxis (χ<sup>2</sup> = 1.007, <i>p</i> &#x3e; 0.05). The same trend was observed among hospitalized patients using anticoagulant and antiplatelet drugs (χ<sup>2</sup> = 2.082, <i>p</i> &#x3e; 0.05). Among the patients with an inhaled oxygen flow rate ≥5 L/min, the incidence of ear-nose-throat (ENT) consultations due to epistaxis was 0. No statistically significant difference was found between inpatients with a humidified oxygen inhalation flow rate &#x3c;5 L/min and those without nasal cannula oxygen therapy in the incidence of ENT consultations due to epistaxis (χ<sup>2</sup> = 0.838, <i>p</i> &#x3e; 0.05). A statistically significant difference was observed in the incidence of ENT consultations due to epistaxis between the low-flow nonhumidified nasal cannula and nonnasal cannula oxygen inhalation groups (χ<sup>2</sup> = 18.428, <i>p</i> &#x3c; 0.001). The same trend was observed between the 2 groups of low-flow humidified and low-flow nonhumidified nasal cannula oxygen inhalation (χ<sup>2</sup> = 26.194, <i>p</i> &#x3c; 0.001). <b><i>Discussion/Conclusion:</i></b> Neither high-flow humidified nasal cannula oxygen inhalation nor low-flow humidified nasal cannula oxygen inhalation will increase the incidence of recurrent or serious epistaxis complications; the same trend was observed for patients who use anticoagulant and antiplatelet drugs. Humidification during low-flow nasal cannula oxygen inhalation can prevent severe and repeated epistaxis to a certain extent.


1978 ◽  
Vol 98 (1) ◽  
pp. 124-128
Author(s):  
YOSHITERU TSUCHIYA ◽  
TOSHIHIKO OKAMOTO
Keyword(s):  

Author(s):  
Yo Han Jung ◽  
Young Uk Min ◽  
Jin Young Kim

This paper presents a numerical investigation of the effect of tip clearance on the suction performance and flow characteristics at different flow rates in a vertical mixed-flow pump. Numerical analyses were carried out by solving three-dimensional Reynolds-averaged Navier-Stokes equations. Steady computations were performed for three different tip clearances under noncavitating and cavitating conditions at design and off-design conditions. The pump performance test was performed for the mixed-flow pump and numerical results were validated by comparing the experimental data for a system characterized by the original tip clearance. It was shown that for large tip clearance, the head breakdown occurred earlier at the design and high flow rates. However, the head breakdown was quite delayed at low flow rate. This resulted from the cavitation structure caused by the tip leakage flow at different flow rates.


2019 ◽  
Vol 36 (4) ◽  
pp. 401-410 ◽  
Author(s):  
Xiao-Qi Jia ◽  
Bao-Ling Cui ◽  
Zu-Chao Zhu ◽  
Yu-Liang Zhang

Abstract Affected by rotor–stator interaction and unstable inner flow, asymmetric pressure distributions and pressure fluctuations cannot be avoided in centrifugal pumps. To study the pressure distributions on volute and front casing walls, dynamic pressure tests are carried out on a centrifugal pump. Frequency spectrum analysis of pressure fluctuation is presented based on Fast Fourier transform and steady pressure distribution is obtained based on time-average method. The results show that amplitudes of pressure fluctuation and blade-passing frequency are sensitive to the flow rate. At low flow rates, high-pressure region and large pressure gradients near the volute tongue are observed, and the main factors contributing to the pressure fluctuation are fluctuations in blade-passing frequency and high-frequency fluctuations. By contrast, at high flow rates, fluctuations of rotating-frequency and low frequencies are the main contributors to pressure fluctuation. Moreover, at low flow rates, pressure near volute tongue increases rapidly at first and thereafter increases slowly, whereas at high flow rates, pressure decreases sharply. Asymmetries are observed in the pressure distributions on both volute and front casing walls. With increasing of flow rate, both asymmetries in the pressure distributions and magnitude of the pressure decrease.


2012 ◽  
Vol 518-523 ◽  
pp. 4126-4129
Author(s):  
Zhen Hua Liu

Source of water is the beginning of rural drinking water projects, safe water source is the key to rural drinking water safety. Status of rural drinking water source in china and laws and regulations on rural water conservation were analyzed. The population of centralized water supply accounts for 51% of the total population in rural areas in 2008, centralized water supply 49%. Groundwater source accounts for 57% of the population of centralized water supply projects in rural areas in 2008, surface water sources 43%. China has a relatively sound legal system of drinking water source, including basic law, general law, administrative regulations, local regulations.The paper draws a conclusion that sources of drinking water in rural areas is mainly groundwater, water conservation is short of specific laws and regulations and not suitable for rural area,it is necessary to improve laws and regulations on rural water conservation, government must assume responsibility for rural water conservation, especially financial investment and public policy support.


Sign in / Sign up

Export Citation Format

Share Document