scholarly journals Heat transfer studies on spiral plate heat exchanger

2008 ◽  
Vol 12 (3) ◽  
pp. 85-90 ◽  
Author(s):  
Rangasamy Rajavel ◽  
Kaliannagounder Saravanan

In this paper, the heat transfer coefficients in a spiral plate heat exchanger are investigated. The test section consists of a plate of width 0.3150 m, thickness 0.001 m and mean hydraulic diameter of 0.01 m. The mass flow rate of hot water (hot fluid) is varying from 0.5 to 0.8 kg/s and the mass flow rate of cold water (cold fluid) varies from 0.4 to 0.7 kg/s. Experiments have been conducted by varying the mass flow rate, temperature, and pressure of cold fluid, keeping the mass flow rate of hot fluid constant. The effects of relevant parameters on spiral plate heat exchanger are investigated. The data obtained from the experimental study are compared with the theoretical data. Besides, a new correlation for the Nusselt number which can be used for practical applications is proposed.


2020 ◽  
Vol 6 (6) ◽  
pp. 15-28
Author(s):  
Anil Kumar ◽  
Rashmi Dwivedi ◽  
Sanjay Chhalotre

The main objective of this work is to compare different configurations of helical baffles in the cold fluid side of a double tube heat exchanger. For this analysis double pipe heat exchangers are divided into three different domains such as two fluid domains hot fluid in the inner tube and cold fluid in the outer pipe and a solid domain as helical baffles on inner tube of hot fluid. The hot water flows inside the heat exchanger tube, while the cold fluid flows in the outer side in the direction of counter flow. Mass flow rate cold fluid was varied from 0.1 kg/s to 0.3 kg/s while the flow rate in the inner tube i.e. hot water was kept constant at 0.1 kg/s. the inlet temperature of hot fluid taken as 40oC while Cold fluid inlet temperature taken as 15oC. The fluent software is used to calculate the fluid flow and heat transfer in the computational domains. The governing equations are iteratively solved by the finite volume formulation with the SIMPLE algorithm. Results show that that the maximum temperature drop of 10.9 oC for hot fluid and the maximum temperature rise of 11.9 oC for cold fluid are observed at 0.3 kg/sec mass flow rate for double pipe heat exchanger with double helical baffles. It has been also observed that the heat transfer coefficient increasing with the increasing in the mass flow rate of cold fluid. The overall heat transfer coefficients differ significantly by 20.4 % at same mass flow rate, because the considerable difference between heat transfer surface area on the inner and outer side of the tube resulting in a prominent thermal enhancement of the cold fluid.



2021 ◽  
Vol 16 (1) ◽  
pp. 007-011
Author(s):  
Mohamed Thoufick K

Experimentally to analyzed the enhance performance of Plate heat exchanger in milk pasteurization process using nanofluid at different concentration of 0.1%,0.15%,0.2% 0.25% and 0.3%. in this work the nanoparticles like Al2O3 and the base fluid like dematerialized water is used to prepare nanofluid by using two steps method. Exchanger is one of the thermal energy transferring devices, which transfer the heat between different fluids. This is widely used in different application because of its compact in size and higher efficiency compared to other type of heat exchanger. The main focus of using nanofluid is that it has improvement in thermal conductivity. Then the hot fluid as milk and cold fluid as nanofluids are used. The heat transfer rate is increased with increasing the concentration of nanofluid. It conducted by varying operating parameters like mass flow rate of hot milk, mass flow rate of nanofluid, inlet and outlet temperatures of hot milk and inlet outlet temperature of nanofluid. The main objective of this work is to find out mass flow rate and overall, all heat transfer coefficient.



In this investigation of multi heat pipe induced in heat exchanger shows the developments in heat transfer is to improve the efficiency of heat exchangers. Water is used as a heat transfer fluid and acetone is used as a working fluid. Rotameter is set to measure the flow rate of cold water and hot water. To maintain the parameter as experimental setup. Then set the mass flow rate of hot water as 40 LPH, 60LPH, 80 LPH, 100LPH, 120 LPH and mass flow rate of cold water as 20 LPH, 30 LPH, 40 LPH, 50 LPH, and 60 LPH. Then 40 C, 45 ºC, 50 ºC, 55 C, 60 ºC are the temperatures of hot water at inlet are maintained. To find some various physical parameters of Qc , hc , Re ,, Pr , Rth. The maximum effectiveness of the investigation obtained from condition of Thi 60 C, Tci 32 C and 100 LPH mhi, 60 LPH mci the maximum effectiveness attained as 57.25. Then the mhi as 100 LPH, mci as 60 LPH and Thi at 40 C as 37.6%. It shows the effectiveness get increased about 34.3 to the maximum conditions.



Energies ◽  
2018 ◽  
Vol 11 (8) ◽  
pp. 2137 ◽  
Author(s):  
Jorge Chan ◽  
Roberto Best ◽  
Jesús Cerezo ◽  
Mario Barrera ◽  
Francisco Lezama

Absorption systems are a sustainable solution as solar driven air conditioning devices in places with warm climatic conditions, however, the reliability of these systems must be improved. The absorbing component has a significant effect on the cycle performance, as this process is complex and needs efficient heat exchangers. This paper presents an experimental study of a bubble mode absorption in a plate heat exchanger (PHE)-type absorber with NH3-LiNO3 using a vapor distributor in order to increase the mass transfer at solar cooling operating conditions. The vapor distributor had a diameter of 0.005 m with five perforations distributed uniformly along the tube. Experiments were carried out using a corrugated plate heat exchanger model NB51, with three channels, where the ammonia vapor was injected in a bubble mode into the solution in the central channel. The range of solution concentrations and mass flow rates of the dilute solution were from 35 to 50% weight and 11.69 to 35.46 × 10−3 kg·s−1, respectively. The mass flow rate of ammonia vapor was from 0.79 to 4.92 × 10−3 kg·s−1 and the mass flow rate of cooling water was fixed at 0.31 kg·s−1. The results achieved for the absorbed flux was 0.015 to 0.024 kg m−2·s−1 and the values obtained for the mass transfer coefficient were in the order of 0.036 to 0.059 m·s−1. The solution heat transfer coefficient values were obtained from 0.9 to 1.8 kW·m−2·K−1 under transition conditions and from 0.96 to 3.16 kW·m−2·K−1 at turbulent conditions. Nusselt number correlations were obtained based on experimental data during the absorption process with the NH3-LiNO3 working pair.



Author(s):  
Luca Cirillo ◽  
Oronzio Manca ◽  
Lorenzo Marinelli ◽  
Sergio Nardini

In this paper an experimental investigation on forced convection in a compact heat exchanger made up with an aluminum foam plate of 212.5mm × 212.5mm with a thickness of 40 mm and a single array with five circular tubes is presented. The foam has a porosity of 0.93 with 20 pores per inch and the tubes in aluminum have internal and external diameters equal to 9.5 mm and 12.5 mm. The test rig consists of an open air channel and a closed water cycle and the aluminum foam plate is placed inside the channel. The performances of the compact heat exchanger are evaluated for assigned hot water mass flow rate and different hot water inlet temperatures and air mass flow rate. Results are given in terms of heat transfer rates and pressure drops as a function of air velocity and Reynolds numbers. The evaluation of dimensionless, thermal resistance, Colburn factor and Nusselt number is performed for different air mass flow rates and hot water inlet temperatures. The performance evaluation criteria is considered in terms of ratio between the heat transfer rate inside the heat exchanger and the pumping power of the air fan.



2009 ◽  
Vol 4 (1) ◽  
Author(s):  
K.Dheena Thayalan ◽  
Ponnusamy Kalaichelvi

The plate heat exchanger exhibits excellent heat transfer characteristic, which allows a very compact design with ease of maintenance and modification of heat transfer area by adding (or) removing plates. Constructional parameters such as flow path, trough angle and corrugation can affect the performance of plate heat exchangers by altering effectiveness (?) and number of transfer unit (NTU). Especially plate heat exchangers play a vital role in petroleum industries for wide range of temperature application. Hence, it was proposed to choose kerosene as cold fluid and hot water as hot fluid in this present investigation. A vertical type of plate heat exchanger, in which flow pattern is maintained as co-current, has been used to conduct the experimental runs. The numbers of plates in the plate heat exchanger used in the present study are 10. The number of flow channels (space maintained between two consecutive channels) allocated for both fluids are 9. Experimental runs have been conducted for different combinations of hot fluid flow rates and cold fluid flow rates for single phase flow, in which hot water is considered as hot streams and kerosene as cold fluid. The thermal performance of plate heat exchanger has been analyzed based on calculated parameters using experimental data set. A similar corrugated plate heat exchanger model having the same dimensions as that of the experimental one was developed with aid of CFD tool. The model was simulated at different operating conditions and compared with experimental results. The simulated results are in good agreement with experimental data. The percentage deviation between experimental results and simulation results for over all heat transfer coefficient is less than ±6%.



2020 ◽  
Vol 4 (2) ◽  
pp. 167-172
Author(s):  
Sreedhar Rao Battula ◽  
Keerthana Reddy Chittireddy ◽  
Meena Pullurwar ◽  
Kishore Kumar Sriramoju

This paper reports an experimental comparative thermal analysis of a flat plate heat exchanger and corrugated plate heat exchanger (CPHE) of different corrugation angles using ethylene glycol as test fluid. The experiments were carried out counter current mode using water as hot fluid at 75°C.  Design of each plate provided with eleven thermocouple sensors to determine the temperatures, in which seven were used to measure the surface temperature of plate and four were used to measure the inlet and outlet bulk temperature of cold and hot fluids.  The mass flow rate of test fluid, varied between 0.5 to 4 liters per minute and corresponding steady state temperatures is measured. Using experimental readings, temperature difference between the inlet and outlet streams (DT), logarithmic mean temperature difference (LMTD) and overall heat transfer coefficient (U) are determined. The obtained DT and U values of corrugation angles (300, 500) of CPHE were compared with those of flat plate heat exchangers. For corrugation angle of 30° and 50°, the DT and U values increases with increase of mass flow rate of the fluid.



2015 ◽  
Vol 55 (4) ◽  
pp. 267 ◽  
Author(s):  
Jan Skočilas ◽  
Ievgen Palaziuk

<p>This paper deals with a computational fluid dynamics (CFD) simulation of the heat transfer process during turbulent hot water flow between two chevron plates in a plate heat exchanger. A three-dimensional model with the simplified geometry of two cross-corrugated channels provided by chevron plates, taking into account the inlet and outlet ports, has been designed for the numerical study. The numerical model was based on the shear-stress transport (SST) <em>k-!</em> model. The basic characteristics of the heat exchanger, as values of heat transfer coefficient and pressure drop, have been investigated. A comparative analysis of analytical calculation results, based on experimental data obtained from literature, and of the results obtained by numerical simulation, has been carried out. The coefficients and the exponents in the design equations for the considered plates have been arranged by using simulation results. The influence on the main flow parameters of the corrugation inclination angle relative to the flow direction has been taken into account. An analysis of the temperature distribution across the plates has been carried out, and it has shown the presence of zones with higher heat losses and low fluid flow intensity.</p>



2015 ◽  
Vol 62 (4) ◽  
pp. 509-522 ◽  
Author(s):  
R. Dharmalingam ◽  
K.K. Sivagnanaprabhu ◽  
J. Yogaraja ◽  
S. Gunasekaran ◽  
R. Mohan

Abstract Cooling is indispensable for maintaining the desired performance and reliability over a very huge variety of products like electronic devices, computer, automobiles, high power laser system etc. Apart from the heat load amplification and heat fluxes caused by many industrial products, cooling is one of the major technical challenges encountered by the industries like manufacturing sectors, transportation, microelectronics, etc. Normally water, ethylene glycol and oil are being used as the fluid to carry away the heat in these devices. The development of nanofluid generally shows a better heat transfer characteristics than the water. This research work summarizes the experimental study of the forced convective heat transfer and flow characteristics of a nanofluid consisting of water and 1% Al2O3 (volume concentration) nanoparticle flowing in a parallel flow, counter flow and shell and tube heat exchanger under laminar flow conditions. The Al2O3 nanoparticles of about 50 nm diameter are used in this work. Three different mass flow rates have been selected and the experiments have been conducted and their results are reported. This result portrays that the overall heat transfer coefficient and dimensionless Nusselt number of nanofluid is slightly higher than that of the base liquid at same mass flow rate at same inlet temperature. From the experimental result it is clear that the overall heat transfer coefficient of the nanofluid increases with an increase in the mass flow rate. It shows that whenever mass flow rate increases, the overall heat transfer coefficient along with Nusselt number eventually increases irrespective of flow direction. It was also found that during the increase in mass flow rate LMTD value ultimately decreases irrespective of flow direction. However, shell and tube heat exchanger provides better heat transfer characteristics than parallel and counter flow heat exchanger due to multi pass flow of nanofluid. The overall heat transfer coefficient, Nusselt number and logarithmic mean temperature difference of the water and Al2O3 /water nanofluid are also studied and the results are plotted graphically.



2014 ◽  
Vol 18 (4) ◽  
pp. 1355-1360 ◽  
Author(s):  
Rajavel Rangasamy

An experimental and numerical study of heat transfer and flow characteristics of spiral plate heat exchanger was carried out. The effects of geometrical aspects of the spiral plate heat exchanger and fluid properties on the heat transfer characteristics were also studied. Three spiral plate heat exchangers with different plate spacing (4mm, 5mm and 6 mm) were designed, fabricated and tested. Physical models have been experimented for different process fluids and flow conditions. Water is taken as test fluid. The effect of mass flow rate and Reynolds number on heat transfer coefficient has been studied. Correlation has been developed to predict Nusselt numbers. Numerical models have been simulated using CFD software package FLUENT 6.3.26. The numerical Nusselt number have been calculated and compared with that of experimental Nusselt number.



Sign in / Sign up

Export Citation Format

Share Document