scholarly journals Voltammetric pH Measurements in Unadulterated Foodstuffs, Urine, and Serum with 3D-Printed Graphene/poly(lactic Acid) Electrodes

Author(s):  
Fakher M. Rabboh ◽  
Glen O'Neil

The pH of a system is a critical descriptor of its chemistry – impacting reaction rates, solubility, chemical speciation, and homeostasis. As a result, pH is one of the most commonly measured parameters in food safety, clinical, and environmental laboratories. Glass pH probes are the gold standard for pH measurements, but suffer drawbacks including frequent recalibration, wet storage of the glass membrane, difficulty in miniaturization, and interferences from alkali metals. In this work, we describe a voltammetric pH sensor that uses a 3D-printed graphene/poly(lactic acid) filament electrode that is pretreated to introduce quinone functional groups to the graphene surface. After thoroughly characterizing the pretreatment parameters using outer-sphere and inner-sphere redox couples, we measured pH by reducing the surface-bound quinones, which undergo a pH-dependent 2e<sup>–</sup>/2H<sup>+</sup> reduction. The position of the redox peak was found to shift –60 ± 2 mV pH<sup>-1</sup> at 25 ºC, which is in excellent agreement with the theoretical value predicted by the Nernst Equation (–59.2 mV pH<sup>-1</sup>). Importantly, the sensors did not require the removal of dissolved oxygen prior to successful pH measurements. We investigated the impact of common interfering species (Pb<sup>2+</sup> and Cu<sup>2+</sup>) and found that there was no impact on the measured pH. We subsequently challenged the sensors to measure the pH of unadulterated complex samples including cola, vinegar, serum, and urine, and obtained excellent agreement compared to a glass pH electrode. In addition to the positive analytical characteristics, the sensors are extremely cheap and easy to fabricate, making them highly accessible to a wide range of researchers. These results pave the way for customizable pH sensors that can be fabricated in (nearly) any geometry for targeted applications using 3D-printing.

2020 ◽  
Author(s):  
Fakher M. Rabboh ◽  
Glen O'Neil

The pH of a system is a critical descriptor of its chemistry – impacting reaction rates, solubility, chemical speciation, and homeostasis. As a result, pH is one of the most commonly measured parameters in food safety, clinical, and environmental laboratories. Glass pH probes are the gold standard for pH measurements, but suffer drawbacks including frequent recalibration, wet storage of the glass membrane, difficulty in miniaturization, and interferences from alkali metals. In this work, we describe a voltammetric pH sensor that uses a 3D-printed graphene/poly(lactic acid) filament electrode that is pretreated to introduce quinone functional groups to the graphene surface. After thoroughly characterizing the pretreatment parameters using outer-sphere and inner-sphere redox couples, we measured pH by reducing the surface-bound quinones, which undergo a pH-dependent 2e<sup>–</sup>/2H<sup>+</sup> reduction. The position of the redox peak was found to shift –60 ± 2 mV pH<sup>-1</sup> at 25 ºC, which is in excellent agreement with the theoretical value predicted by the Nernst Equation (–59.2 mV pH<sup>-1</sup>). Importantly, the sensors did not require the removal of dissolved oxygen prior to successful pH measurements. We investigated the impact of common interfering species (Pb<sup>2+</sup> and Cu<sup>2+</sup>) and found that there was no impact on the measured pH. We subsequently challenged the sensors to measure the pH of unadulterated complex samples including cola, vinegar, serum, and urine, and obtained excellent agreement compared to a glass pH electrode. In addition to the positive analytical characteristics, the sensors are extremely cheap and easy to fabricate, making them highly accessible to a wide range of researchers. These results pave the way for customizable pH sensors that can be fabricated in (nearly) any geometry for targeted applications using 3D-printing.


Technologies ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. 71
Author(s):  
Guido Ehrmann ◽  
Bennet Brockhagen ◽  
Andrea Ehrmann

Poly(lactic acid) (PLA) belongs to the 3D printable materials which show shape-memory properties, i.e., which can recover their original shape after a deformation if they are heated above the glass transition temperature. This makes PLA quite an interesting material for diverse applications, such as bumpers, safety equipment for sports, etc. After investigating the influence of the infill design and degree, as well as the pressure orientation on the recovery properties of 3D printed PLA cubes in previous studies, here we report on differences between different PLA materials as well as on the impact of post-treatments after 3D printing by solvents or by heat. Our results show not only large differences between materials from different producers, but also a material-dependent impact of the post treatments. Generally, it is possible to tailor the mechanical and recovery properties of 3D printed PLA parts by choosing the proper material in combination with a chemical or temperature post-treatment.


2021 ◽  
pp. 002199832098856
Author(s):  
Marcela Piassi Bernardo ◽  
Bruna Cristina Rodrigues da Silva ◽  
Luiz Henrique Capparelli Mattoso

Injured bone tissues can be healed with scaffolds, which could be manufactured using the fused deposition modeling (FDM) strategy. Poly(lactic acid) (PLA) is one of the most biocompatible polymers suitable for FDM, while hydroxyapatite (HA) could improve the bioactivity of scaffold due to its chemical composition. Therefore, the combination of PLA/HA can create composite filaments adequate for FDM and with high osteoconductive and osteointegration potentials. In this work, we proposed a different approache to improve the potential bioactivity of 3D printed scaffolds for bone tissue engineering by increasing the HA loading (20-30%) in the PLA composite filaments. Two routes were investigated regarding the use of solvents in the filament production. To assess the suitability of the FDM-3D printing process, and the influence of the HA content on the polymer matrix, thermogravimetric analysis (TGA), differential scanning calorimetry (DSC) and scanning electron microscopy (SEM) were performed. The HA phase content of the composite filaments agreed with the initial composite proportions. The wettability of the 3D printed scaffolds was also increased. It was shown a greener route for obtaining composite filaments that generate scaffolds with properties similar to those obtained by the solvent casting, with high HA content and great potential to be used as a bone graft.


Polymers ◽  
2021 ◽  
Vol 13 (15) ◽  
pp. 2531
Author(s):  
Rodion Kopitzky

Sugar beet pulp (SBP) is a residue available in large quantities from the sugar industry, and can serve as a cost-effective bio-based and biodegradable filler for fully bio-based compounds based on bio-based polyesters. The heterogeneous cell structure of sugar beet suggests that the processing of SBP can affect the properties of the composite. An “Ultra-Rotor” type air turbulence mill was used to produce SBP particles of different sizes. These particles were processed in a twin-screw extruder with poly(lactic acid) (PLA) and poly(butylene succinate) (PBS) and fillers to granules for possible marketable formulations. Different screw designs, compatibilizers and the use of glycerol as a thermoplasticization agent for SBP were also tested. The spherical, cubic, or ellipsoidal-like shaped particles of SBP are not suitable for usage as a fiber-like reinforcement. In addition, the fineness of ground SBP affects the mechanical properties because (i) a high proportion of polar surfaces leads to poor compatibility, and (ii) due to the inner structure of the particulate matter, the strength of the composite is limited to the cohesive strength of compressed sugar-cell compartments of the SBP. The compatibilization of the polymer–matrix–particle interface can be achieved by using compatibilizers of different types. Scanning electron microscopy (SEM) fracture patterns show that the compatibilization can lead to both well-bonded particles and cohesive fracture patterns in the matrix. Nevertheless, the mechanical properties are limited by the impact and elongation behavior. Therefore, the applications of SBP-based composites must be well considered.


Molecules ◽  
2021 ◽  
Vol 26 (11) ◽  
pp. 3234
Author(s):  
Wangwang Yu ◽  
Lili Dong ◽  
Wen Lei ◽  
Yuhan Zhou ◽  
Yongzhe Pu ◽  
...  

To develop a new kind of environment-friendly composite filament for fused deposition modeling (FDM) 3D printing, rice straw powder (RSP)/poly(lactic acid) (PLA) biocomposites were FDM-3D-printed, and the effects of the particle size and pretreatment of RSP on the properties of RSP/PLA biocomposites were investigated. The results indicated that the 120-mesh RSP/PLA biocomposites (named 120#RSP/PLA) showed better performance than RSP/PLA biocomposites prepared with other RSP sizes. Infrared results showed that pretreatment of RSP by different methods was successful, and scanning electron microscopy indicated that composites prepared after pretreatment exhibited good interfacial compatibility due to a preferable binding force between fiber and matrix. When RSP was synergistically pretreated by alkaline and ultrasound, the composite exhibited a high tensile strength, tensile modulus, flexural strength, and flexural modulus of 58.59, 568.68, 90.32, and 3218.12 MPa, respectively, reflecting an increase of 31.19%, 16.48%, 18.75%, and 25.27%, respectively, compared with unmodified 120#RSP/PLA. Pretreatment of RSP also improved the thermal stability and hydrophobic properties, while reducing the water absorption of 120#RSP/PLA. This work is believed to provide highlights of the development of cost-effective biocomposite filaments and improvement of the properties of FDM parts.


2019 ◽  
Vol 64 (No. 12) ◽  
pp. 531-538
Author(s):  
JW Yun ◽  
SY Heo ◽  
MH Lee ◽  
HB Lee

Critical-sized bone defects are a difficult problem in both human and veterinary medicine. To address this issue, synthetic graft materials have been garnering attention. Abundant in vitro studies have proven the possibilities of poly(lactic-acid) (PLA) scaffolds and poly(lactide-co-glycolide)/hydroxyapatite (PLGA/HAp) nanofibres for treating bone defects. The present study aimed at conducting an in vivo assessment of the biological performance of a three dimensional (3D)-printed PLA scaffold filled with a PLGA/HAp nanofibrous scaffold to estimate its potential applications in bone defect reconstruction surgery. Defects were created in a 20 mm-long region of the radius bone. The defects created on the right side in six Beagle dogs (n = 6) were left untreated (Group 1). The defects on the left side (n = 6) were filled with 3D-printed PLA scaffolds incorporated with PLGA/Hap nanofibres with gelatine (Group 2). The other six Beagle dog defects were made bilaterally (n = 12) and filled with the same material as that used in Group 2 along with recombinant bone morphogenetic protein 2 (rhBMP-2) (Group 3). Both the radiological and histological examinations were performed for observing the reaction of the scaffold and the bone. Micro-computed tomography (CT) was utilised for the evaluation of the bone parameters 20 weeks after the experiment. The radiological and histological results revealed that the scaffold was biodegradable and was replaced by new bone tissue. The micro-CT revealed that the bone parameters were significantly (P &lt; 0.05) increased in Group 3. Based on these results, our study serves as a foundation for future studies on bone defect treatment using synthetic polymeric scaffolds.


2021 ◽  
pp. 096739112110576
Author(s):  
Ying Zhou ◽  
Can Chen ◽  
Lan Xie ◽  
Xiaolang Chen ◽  
Guangqiang Xiao ◽  
...  

In this work, novel plasticizing biodegradable poly (lactic acid) (PLA) composites were prepared by melt blending of jute and tung oil anhydride (TOA), and the physical and mechanical properties of PLA/jute/TOA composites were tested and characterized. The impact strength of PLA/jute/TOA composites significantly increases with increasing the content of TOA. The SEM images of fracture surface of PLA/jute/TOA composites become rough after the incorporation of TOA. In addition, TOA changes the crystallization temperature and decomposition process of PLA/jute/TOA composites. With increasing the amount of TOA, the value of storage modulus (E′) of PLA/jute/TOA composites gradually increases. The complex viscosity (η*) values for all samples reduce obviously with increasing the frequency, which means that the pure PLA and PLA/jute/TOA composites is typical pseudoplastic fluid. This is attributed to the formation of crosslinking, which restricts the deformation of the composites.


Sign in / Sign up

Export Citation Format

Share Document