scholarly journals Molar Buccal Tubes Front and Back Openings Dimensions and Torsional Play

2018 ◽  
Vol 30 (3) ◽  
pp. 32-39
Author(s):  
Hiyam J Al-Zubaidi ◽  
Akram F Alhuwaizi

Background/: Buccal tubes are orthodontic attachments used on the posterior teeth instead of bands, so it is important to focus on the effect of their properties on orthodontic treatment. The aims of the present in vitro study are to evaluate and compare the buccal tube front and back openings dimensions and the torsional play angle of six different brands. Materials and Methods: The samples consisted of Single bondable, non-convertible first molar buccal tubes from six brands supplied from six companies (Dentaurum, Forestadent, Ormco, 3M, American Orthodontic, A-Star). Regarding tube opening dimension, ten buccal tubes of each brand were examined by an optical microscope. Each tube was fixed during examination using synthetic mud and oriented for observation of the front and back slot openings. A picture was taken for both tube openings and the result appeared on the computer's screen where width and height measurements were made. While regarding torsional play angle, ten buccal tubes of each brand were used. Each tube was fixed on a metal block attached to a surveyor base. Then an L-shaped wire was inserted inside the front opening of the tube. Two photographs were taken, one with the wire in free fall position and the other with the wire elevated by a 10g weight with the same angle of shooting as the first photograph. Later, the two images were superimposed in Adobe Photoshop program, and an electronic MB-ruler Software was used to calculate the angle which represents the torsional play within each tube. The data were then statistically analyzed using ANOVA and LSD tests. Results: There are marked differences between measured tube dimensions and the manufacturer stated dimensions with the front tube openings being generally larger than the back opening dimensions. Furthermore, the torsional play angle was highest in A-Star and smallest in Ormco's tubes. This angle was significantly correlated to the height of the tube front opening. Conclusion: It can be concluded that tube dimension varies among different companies and effect greatly torsional play angle.

2020 ◽  
Vol 31 (3) ◽  
pp. 257-263
Author(s):  
Aline Laignier Soares-Yoshikawa ◽  
Jaime Aparecido Cury ◽  
Cínthia Pereira Machado Tabchoury

Abstract The aim of this in vitro study was to determine the fluoride concentration in silver diamine fluoride (SDF) products and their bioavailability with demineralized dentine. The products evaluated (expected fluoride concentrations) were: I: Saforide 38% (45,283 ppm F); II: Advantage Arrest 38.3 to 43.2% (45,283 to 51,013 ppm F); III: Ancárie 12% (14,100 ppm F); IV: Ancárie 30% (35,400 ppm F), V: Cariestop 12% (14,100 ppm F) and VI: Cariestop 30% (35,400 ppm F). The fluoride concentration was evaluated using an ion-specific electrode (ISE) by direct technique, which was confirmed after microdiffusion. The pH of the products was determined with a pH test strip. For the bioavailability test, demineralized dentine slabs were treated with one of the products for 1 min. Loosely (CaF2-like) and firmly-bound fluoride (FAp) were determined. The fluoride concentration found in the products (mean±SD; ppm F) by the ISE direct technique was: I:53,491±554; II:57,249±1,851; III:4,814±268; IV:5,726±43; V:10,145±468; VI:11,858±575; these values were confirmed after microdiffusion (t-test; p>0.05) and disagree with the declared by the manufacturers. The pH of Ancárie 12 and 30% was 6.0 and 4.5, respectively, in disagreement with the alkaline pH expected for SDF solution and found in the other products evaluated. There was no correlation between either CaF2-like (r=0.221; p=0.337) or FAp (r=-0.144; p=0.830) formed in demineralized dentine and fluoride concentration found in the products. The problems of pH and fluoride concentration found in available professional commercial SDF products suggest that they are not under sanitary surveillance.


2017 ◽  
Vol 54 (1) ◽  
pp. 129-132
Author(s):  
Andreea Simona Pop ◽  
Radu Septimiu Campian ◽  
Mariana Pacurar ◽  
Elina Teodorescu ◽  
Olimpia Bunta ◽  
...  

Sealing the pits and fissures of posterior teeth represents a local and specific method of caries prevention. The aim of this study was to evaluate the adhesion of two materials used in sealing pits and fissures: Pitt and Fisure and Fissurit FX (Voco), with the help of the scanning electronic microscope (SEM). The results of the study revealed a much higher quality of the Fissurit FX (Voco) product both in terms of adhesion to the enamel and material homogeneity. The Pitt and Fisure product showed a high degree of detachment from the enamel, marginal infiltration, large particles and a high concentration of inorganic particles.


Author(s):  
C Gozzard ◽  
S Gheduzzi ◽  
A W Miles ◽  
I D Learmonth

Adequate cement pressurization during stem insertion improves the interdigitation of cement into bone. This increases the strength of the cement-bone interface, thus contributing to the reduction of the incidence of aseptic loosening, the commonest cause of revision surgery. This in-vitro study compared the cement pressurization achieved during insertion of four different stems of equivalent sizes: the Elite Plus (DePuy, UK), C-Stem (DePuy, UK), Exeter (Stryker, USA), and CPS-Plus (Plus Orthopedics, Switzerland). The maximum pressures attained at the time of stem insertion were recorded at proximal, mid and distal stem levels. The Elite Plus generated significantly higher distal pressures than the other stems. The CPS-Plus generated significantly greater proximal cement pressures than the Elite Plus, C-Stem, and Exeter prostheses. The triple taper of the C-Stem increased the cement pressurization medial to the stem. The stem shape and the presence or absence of a proximal stem centralizer affect cement pressurization. The presence of a proximal stem centralizer, a large stem volume, and a lateral-medial taper are all factors associated with increased cement pressurization during stem insertion.


1997 ◽  
Vol 41 (2) ◽  
pp. 335-346 ◽  
Author(s):  
Naoyuki Matsumoto ◽  
Fumiaki Kawano ◽  
Kan Nagao ◽  
Nozomu Tada

2020 ◽  
Vol 45 (1) ◽  
pp. 62-70
Author(s):  
C Dettwiler ◽  
F Eggmann ◽  
L Matthisson ◽  
C Meller ◽  
R Weiger ◽  
...  

SUMMARY Aim: The aim of this study was to quantitatively compare conventional composite removal and composite removal supported by the fluorescence-aided identification technique (FIT) regarding the completeness, selectivity, and duration of the procedure in directly restored permanent posterior teeth. Methods and Materials: Two operators removed standardized direct class II composite restorations (n=32 per operator) in human tooth models under simulated clinical conditions. According to a randomized allocation scheme, removal was performed with either the conventional technique (contra-angle handpiece) or supported by FIT. The duration of each removal procedure was recorded. The completeness and selectivity were volumetrically assessed through superimposition of three-dimensional surface scans. Statistical significance was tested by examining the overlap of 95% confidence intervals (CI). Multiple comparison was performed with Tukey tests for each variable. Results: Compared with the conventional technique, composite removal with FIT was faster (329 seconds [95% confidence interval (CI): 268-390 seconds] vs 179 seconds [95% CI: 150-208 seconds]), generated less tooth substance loss (4.53 mm3 [95% CI: 3.77-5.30 mm3] vs 2.77 mm3 [95% CI: 2.11-3.43 mm3]), and left behind less composite residue (1.58 mm3 [95% CI: 1.23-1.94 mm3] vs 0.53 mm3 [95% CI: 0.39-0.67 mm3]). Conclusion: Within the limitations of this in vitro study, FIT facilitated the selective and expeditious removal of tooth-colored composites in directly restored posterior teeth.


2019 ◽  
Vol 6 (2) ◽  
pp. 36
Author(s):  
Cristina Leon-Pineda ◽  
Kevin Donly

Recurrent caries is still considered the main reason restorations need to be replaced. There are different materials available now that promise to reduce the possibility of recurrent caries by releasing fluoride and inhibiting restoration marginal caries. The purpose of this in vitro study was to evaluate the demineralization inhibition potential of a non-fluoride-releasing resin (Z100TM 3M, St. Paul, MN, USA) and a glass containing resin-based composite (Tetric EvoCeram Bulk Fill, Ivoclar/Vivadent AG, Schaan, Liechtenstein), which contains fluoride. Class V preparations were placed on 22 premolars; the gingival margin was below the cementoenamel junction and the occlusal margin was placed above the cemento-enamel junction. Ten teeth were randomly selected to be restored with Z100 while the other 10 were restored with Tetric EvoCeram Bulk Fill. Both groups were restored following manufacturer’s instructions. All teeth had an acid resistant varnish placed within one millimeter of the preparation margins. Both groups were placed in artificial caries challenge solution (pH 4.4). At the end of the 4 days; 100 µm buccolingual sections were obtained for each tooth; these were photographed under polarized light microscopy and the demineralized areas adjacent to the restorations were measured and quantified. The mean (±S.D.) area (µm2) of demineralization from the occlusal margin (enamel) and dentin margin were: Z100 2781.889 ± 1045.213; 3960.455 ± 705.964 and for Tetric EvoCeram Bulk Fill 1541.545 ± 1167.027; 3027.600 ± 512.078. Student’s t-test indicated that there was significantly less enamel and dentin demineralization adjacent to Tetric EvoCeram Bulk Fill compared to Z100; there was significantly less demineralization in enamel compared to dentin in both Tetric EvoCeral Bulk Fill and Z100. Tetric EvoCeram Bulk Fill performed better inhibiting demineralization at restoration margins when compared to Z100 and provided better demineralization inhibition in enamel than cementum/dentin.


2019 ◽  
Vol 196 (2) ◽  
pp. 646-653 ◽  
Author(s):  
Aneta Olszewska ◽  
Anetta Hanć ◽  
Danuta Barałkiewicz ◽  
Piotr Rzymski

Abstract Elastomeric ligatures are increasingly used as a part of esthetic orthodontic treatment, particularly in children. The aim of the present study was to experimentally test whether these appliances may contribute to exposure to toxic elements. In the present study, elastomeric ligatures (ELs) were incubated in artificial human saliva for 1 month (a typical period of their use) and the release of 21 metals (Ba, Cd, Co, Cr, Cu, Fe, Li, Mn, Mg, Mo, Ni, Pb, Rb, Tl, Ti, Sb, Sr, Sn, Zn, U, V) and 2 metalloids (As and Ge) was studied using inductively coupled plasma–mass spectrometry. For comparison, stainless steel ligatures (SLs) were incubated for 1, 3, and 6 months (since sometimes their use is prolonged) under similar conditions. The determined metal levels were compared to the corresponding safety limits for human exposure. During 1 month, the ELs released Cd, Co, Cr, Mn, Ni, and Sn at total mean ± SD level of 0.31 ± 0.09, 0.98 ± 0.30, 3.96 ± 1.31, 14.7 ± 8.5, 13.8 ± 4.8, and 49.5 ± 27.7 μg, respectively. Other elements were always below the detection limits. In case of SL, the release of Co, Cr, Fe, Ni, Mn, and Sn was observed, and the determined values increased over the studied period. After 6 months, their total mean ± SD levels amounted to 28.6 ± 0.2, 21.7 ± 0.2, 623.5 ± 3.0, 1152.7 ± 1.8, 5.5 ± 0.3, and 22.6 ± 0.2 μg, respectively. The released metal levels from both ligature types were always below safety limits. The release of Ni from SL during 6 months would constitute 5.0 and 11.5% of tolerable intake in adults and children, respectively. The results of this in vitro study highlight that the use of ligatures in orthodontic treatment can be considered safe in terms of metal exposure although elastic ligatures replaced on a monthly basis appear to be advantageous in comparison to the prolonged use of stainless steel appliances.


2017 ◽  
Vol 40 (2) ◽  
pp. 82-87 ◽  
Author(s):  
Faika Y. Abdelmegid ◽  
Fouad S. Salama ◽  
Waleed M. Al-Mutairi ◽  
Saud K. Al-Mutairi ◽  
Sultan O. Baghazal

Introduction The aim of this in vitro study was to assess and compare the effect of different intermediary bases on microleakage between tooth and a nanocomposite interface in Class II box cavities in primary teeth. Methods Standard Class II box cavities were prepared in 52 primary molars and randomly divided into 9 groups according to the intermediary base used (Multicore Flow, Fuji II LC, SDR, Smart Dentin Replacement, and Biodentine). All specimens were subjected to thermocycling and prepared for microleakage testing and evaluation. Results There was significant difference in the mean ranks of microleakage between the 9 groups, which was observed in the gingival side (p<0.0001) and the occlusal side (p<0.0001). The mean ranks microleakage was significantly higher with experimental SDR, experimental Multicore Flow, and positive control materials when compared with the other 6 groups. The microleakage mean ranks were statistically significantly lower in experimental Fuji II LC, experimental Biodentine, and all negative control groups when compared with the other 3 groups. Conclusions Microleakage is affected by the application of intermediate material. Experimental Biodentine and Fuji II LC showed the lowest microleakage while experimental SDR and experimental Multicore Flow showed the highest microleakage.


Sign in / Sign up

Export Citation Format

Share Document