Failure Analysis Work Flow for Electrical Shorts in Triple Stacked 3D TSV Daisy Chains

Author(s):  
J. Gaudestad ◽  
A. Orozco ◽  
I. De Wolf ◽  
T. Wang ◽  
T. Webers ◽  
...  

Abstract In this paper we show an efficient workflow that combines Magnetic Field Imaging (MFI) and Dual Beam Plasma Focused Ion Beam (DB-PFIB) for fast and efficient Fault Isolation and root cause analysis in 2.5/3D devices. The work proves MFI is the best method for Electric Fault Isolation (EFI) of short failures in 2.5/3D Through Silicon Via (TSV) triple stacked devices in a true non-destructive way by imaging the current path. To confirm the failing locations and to do Physical Failure Analysis (PFA), a DB-PFIB system was used for cross sectioning and volume analysis of the TSV structures and high resolution imaging of the identified defects. With a DB-PFIB, the fault is exposed and analyzed without any sample prep artifacts seen in mechanical polishing or laser preparation techniques and done in a considerably shorter amount of time than that required when using a traditional Gallium Focused Ion Beam (FIB).

2015 ◽  
Vol 2015 (1) ◽  
pp. 000469-000473 ◽  
Author(s):  
J. Gaudestad ◽  
A. Orozco ◽  
I. De Wolf ◽  
T. Wang ◽  
T. Webers ◽  
...  

In this paper we show an efficient workflow that combines Magnetic Field Imaging (MFI) and Dual Beam Plasma Focused Ion Beam (DB-PFIB) for fast and efficient Fault Isolation and root cause analysis in 2.5/3D devices. The work proves MFI is the best method for Electric Fault Isolation (EFI) of short failures in 2.5/3D Through Silicon Via (TSV) triple stacked devices in a true non-destructive way by imaging the current path. To confirm the failing locations and to do Physical Failure Analysis (PFA), a DB-PFIB system was used for cross sectioning and volume analysis of the TSV structures and high resolution imaging of the identified defects. With a DB-PFIB, the fault is exposed and analyzed without any sample prep artifacts seen in mechanical polishing or laser preparation techniques and done in a considerably shorter amount of time than that required when using a traditional Gallium Focused Ion Beam (FIB).


Author(s):  
C.C. Ooi ◽  
K.H. Siek ◽  
K.S. Sim

Abstract Focused ion beam system has been widely used as a critical failure analysis tool as microprocessor technology advances at a ramping speed. It has become an essential step in failure analysis to reveal physical defects post electrical fault isolation. In this highly competitive and challenging environment prevalent today, failure analysis throughput time is of utmost important. Therefore quick, efficient and reliable physical failure analysis technique is needed to avoid potential issues from becoming bigger. This paper will discuss the applications of FIB as a defect localization and root cause determination tool through the passive charge contrast technique and pattern FIB analysis.


2018 ◽  
Author(s):  
Sze Yee Tan ◽  
Chiu Soon Wong ◽  
Chea Wee Lo ◽  
Cin Sheng Goh

Abstract In the back-end assembly process, all of the packages will be tested prior to disposition to the customers in order to filter out any device with failure. For a reject unit with an unknown failure mechanism, it will be subjected to a comprehensive failure analysis (FA) to identify the root cause of the failure. Non-destructive verification, following by front-side decapsulation and internal physical inspection is the common way to visualise and identify the physical defect that usually causes the failure of a device during the back-end assembly process. For certain failures, visualization of the defect might not be straight forward after the decapsulation because the defect may be embedded or buried underneath a layer or wedge bond on the die. In this case, a more complicated FA analysis flow which comprises various precision techniques such as parallel lapping, hotspot localisation and focused-ion-beam (FIB) analyses will be needed to thin down the top layer/wedge bond for a precise localisation of the defect prior to precision analysis by FIB. However, the process to thin down the top layer/wedge bond with an exposed die of a partially decapsulated package is a tricky job as artefacts such as crack/scratches on die are likely to be introduced during the process of polishing. Also it is relatively difficult to control the thickness and levelling of the top layer/wedge bond during the thinning process. In this work, we developed a method that allows the analyst to re-cap the partially decapped package, and also to precisely measure and thin down the top layer to an accuracy of less than < 2um without the introduction of artefacts.


Author(s):  
Hung Chin Chen ◽  
Chih Yang Tsai ◽  
Shih Yuan Liu ◽  
Yu Pang Chang ◽  
Jian Chang Lin

Abstract Fault isolation is the most important step for Failure Analysis (FA), and it is closely linked with the success rate of failure mechanism finding. In this paper, we will introduce a case that hard to debug with traditional FA skills. In order to find out its root cause, several advanced techniques such as layout tracing, circuit edit and Infrared Ray–Optical Beam Induced Resistance Change (IR-OBIRCH) analysis had been applied. The circuit edit was performed following layout tracing for depositing probing pads by Focused Ion Beam (FIB). Then, IR-OBIRCH analysis with biasing on the two FIB deposited probing pads and a failure location was detected. Finally, the root cause of inter- metal layer bridge was found in subsequent physical failure analysis.


Author(s):  
Frank Altmann ◽  
Christian Grosse ◽  
Falk Naumann ◽  
Jens Beyersdorfer ◽  
Tony Veches

Abstract In this paper we will demonstrate new approaches for failure analysis of memory devices with multiple stacked dies and TSV interconnects. Therefore, TSV specific failure modes are studied on daisy chain test samples. Two analysis flows for defect localization implementing Electron Beam Induced Current (EBAC) imaging and Lock-in-Thermography (LIT) as well as adapted Focused Ion Beam (FIB) preparation and defect characterization by electron microscopy will be discussed. The most challenging failure mode is an electrical short at the TSV sidewall isolation with sub-micrometer dimensions. It is shown that the leakage path to a certain TSV within the stack can firstly be located by applying LIT to a metallographic cross section and secondly pinpointing by FIB/SEM cross-sectioning. In order to evaluate the potential of non-destructive determination of the lateral defect position, as well as the defect depth from only one LIT measurement, 2D thermal simulations of TSV stacks with artificial leakages are performed calculating the phase shift values per die level.


Author(s):  
P. Tangyunyong ◽  
A.Y. Liang ◽  
A.W. Righter ◽  
D.L. Barton ◽  
J.M. Soden

Abstract Fluorescent microthermal imaging (FMI) involves coating a sample surface with a thin fluorescent film that, upon exposure to UV light source, emits temperature-dependent fluorescence [1-7]. The principle behind FMI was thoroughly reviewed at the ISTFA in 1994 [8, 9]. In two recent publications [10,11], we identified several factors in film preparation and data processing that dramatically improved the thermal resolution and sensitivity of FMI. These factors include signal averaging, the use of base mixture films, film stabilization and film curing. These findings significantly enhance the capability of FMI as a failure analysis tool. In this paper, we show several examples that use FMI to quickly localize heat-generating defects ("hot spots"). When used with other failure analysis techniques such as focused ion beam (FIB) cross sectioning and scanning electron microscope (SEM) imaging, we demonstrate that FMI is a powerful tool to efficiently identify the root cause of failures in complex ICs. In addition to defect localization, we use a failing IC to determine the sensitivity of FMI (i.e., the lowest power that can be detected) in an ideal situation where the defects are very localized and near the surface.


Author(s):  
Liang Hong ◽  
Jia Li ◽  
Haifeng Wang

Abstract This paper provides an innovative root cause failure analysis method that combines multiple failure analysis (FA) techniques to narrow down and expose the shorting location and allow the material analysis of the shorting defect. It begins with a basic electrical testing to narrow down shorting metal layers, then utilizing mechanical lapping to expose over coat layers. This is followed by optical beam induced resistance change imaging to further narrow down the shorting location. Scanning electron microscopy and optical imaging are used together with focused ion beam milling to slice and view through the potential shorting area until the shorting defect is exposed. Finally, transmission electron microscopy (TEM) sample is prepared, and TEM analysis is carried out to pin point the root cause of the shorting. This method has been demonstrated successfully on Western Digital inter-metal layers shorting FA.


Author(s):  
Chih-Chung Chang ◽  
Jian-Chang Lin ◽  
Wen-Sheng Wu ◽  
Chih-Ying Tasi ◽  
Ching-Lin Chang

Abstract A dual beam FIB (Focused Ion Beam) system which provides the ion beam (i-beam) and electron beam (e-beam) function are widely used in semiconductor manufacture for construction analysis and failure cause identification. Although FIB is useful for defect or structure inspection, sometimes, it is still difficult to diagnose the root cause via FIB e-beam image due to resolution limitation especially in products using nano meter scale processes. This restriction will deeply impact the FA analysts for worst site or real failure site judgment. The insufficient e-beam resolution can be overcome by advanced TEM (Transmission Electron Microscope) technology, but how can we know if this suspected failure site is a real killer or not when looking at the insufficient e-beam images inside a dual beam tool? Therefore, a novel technique of device measurement by using C-AFM (Conductive Atomic Force Microscope) or Nano-Probing system after cross-sectional (X-S) FIB inspection has been developed based on this requirement. This newly developed technology provides a good chance for the FA analysts to have a device characteristic study before TEM sample preparation. If there is any device characteristic shift by electrical measurement, the following TEM image should show a solid process abnormality with very high confidence. Oppositely, if no device characteristic shift can be measured, FIB milling is suggested to find the real fail site instead of trying TEM inspection directly.


Author(s):  
Jim Shearer ◽  
Kim Le ◽  
Xiaoyu Yang ◽  
Monty Cleeves ◽  
Al Meeks

Abstract This article presents a case study to solve an IDDQ leakage problem using a variety of failure analysis techniques on a product. The product is fabricated using a 3-metal-layer 0.25 μm CMOS process with the addition of Matrix's proprietary 3-D memory layers. The failure analysis used both top and backside analytical techniques, including liquid crystal, photon emission microscopy from both front and back, dual-beam focused ion beam cross-sectioning, field emission scanning electron microscopy imaging, parallel-lap/passive voltage contrast, microprobing of parallel-lapped samples, and scanning capacitance microscopy. The article discusses how the application of each of the techniques narrowed down the search for this IDDQ leakage path. This leakage path was eliminated using the two corrective actions: The resist is pre-treated prior to ion implantation to produce a consistent resist sidewall profile; and the Nwell boundaries were adjusted in the next Nwell mask revision.


Author(s):  
Hong Xiao ◽  
Ximan Jiang

Abstract In this paper, a novel inspection mode of electron beam inspection (EBI) that can effectively detect buried voids in tungsten (W) plugs is reported for the first time. Buried voids in metal are a defect of interest (DOI) that cannot be captured by either optical inspection or traditional EBI modes. The detection of buried voids is achieved by using energetic electron beam (e-beam) with energy high enough to penetrate into metal and reach the buried void. By selecting desired secondary electrons to form the inspection images, strong contrast between the defective tungsten plugs and normal ones can be achieved. Failure analysis was performed on the DOI that is unique to this new EBI mode. After optical microscope locating and laser marking, we successfully recaptured DOI with scanning electron microscope (SEM) and capped the DOI with e-beam assisted platinum (Pt) deposition. Later a dual-beam focused ion beam (FIB) system was used to re-locate the Pt-capped DOI and prepare samples for transmission electron microscope (TEM). TEM images confirmed the unique DOI were buried voids in the metal plugs, which could affect resistance of interconnect in integrated circuit (IC) chip and impact the IC yield.


Sign in / Sign up

Export Citation Format

Share Document