Transmission Electron Microscopy Sample Preparation By Design-Based Recipe Writing in a DBFIB

Author(s):  
J. Demarest ◽  
B. Austin ◽  
J. Arjavac ◽  
M. Breton ◽  
M. Bergendahl ◽  
...  

Abstract Transmission electron microscopy (TEM) sample can be routinely made at a sub 30nm thickness and specific features in semiconductor device design are on the order of 30nm and smaller. As a result, small changes in pattern match registration can significantly influence the success or failure of proper TEM sample placement as an approximately 15nm shift in lamella placement can easily cause the sample to be off the feature of interest. To address this issue, design based recipe writing is being developed on a dual beam focused ion beam platform. The intent is to have the tool read a GDS file and pattern match the design information to physical wafer images in a similar fashion to state-of-the-art critical dimension scanning electron microscopy operation. While the results are very encouraging, more work needs to be done to ensure a TEM sample of approximately 30nm thickness is placed at the desired location.

Author(s):  
Q. Liu ◽  
H.B. Kor ◽  
Y.W. Siah ◽  
C.L. Gan

Abstract Dual-beam focused ion beam (DB-FIB) system is widely used in the semiconductor industry to prepare cross-sections and transmission electron microscopy (TEM) lamellae, modify semiconductor devices and verify layout. One of the factors that limits its success rate is sample charging, which is caused by a lack of conductive path to discharge the accumulated charges. In this paper, an approach using an insitu micromanipulator was investigated to alleviate the charging effects. With this approach, a simple front side semiconductor device modification was carried out and the corresponding stage current was monitored to correlate to the milling process.


Author(s):  
Ching Shan Sung ◽  
Hsiu Ting Lee ◽  
Jian Shing Luo

Abstract Transmission electron microscopy (TEM) plays an important role in the structural analysis and characterization of materials for process evaluation and failure analysis in the integrated circuit (IC) industry as device shrinkage continues. It is well known that a high quality TEM sample is one of the keys which enables to facilitate successful TEM analysis. This paper demonstrates a few examples to show the tricks on positioning, protection deposition, sample dicing, and focused ion beam milling of the TEM sample preparation for advanced DRAMs. The micro-structures of the devices and samples architectures were observed by using cross sectional transmission electron microscopy, scanning electron microscopy, and optical microscopy. Following these tricks can help readers to prepare TEM samples with higher quality and efficiency.


Author(s):  
K. Doong ◽  
J.-M. Fu ◽  
Y.-C. Huang

Abstract The specimen preparation technique using focused ion beam (FIB) to generate cross-sectional transmission electron microscopy (XTEM) samples of chemical vapor deposition (CVD) of Tungsten-plug (W-plug) and Tungsten Silicides (WSix) was studied. Using the combination method including two axes tilting[l], gas enhanced focused ion beam milling[2] and sacrificial metal coating on both sides of electron transmission membrane[3], it was possible to prepare a sample with minimal thickness (less than 1000 A) to get high spatial resolution in TEM observation. Based on this novel thinning technique, some applications such as XTEM observation of W-plug with different aspect ratio (I - 6), and the grain structure of CVD W-plug and CVD WSix were done. Also the problems and artifacts of XTEM sample preparation of high Z-factor material such as CVD W-plug and CVD WSix were given and the ways to avoid or minimize them were suggested.


Author(s):  
Chin Kai Liu ◽  
Chi Jen. Chen ◽  
Jeh Yan.Chiou ◽  
David Su

Abstract Focused ion beam (FIB) has become a useful tool in the Integrated Circuit (IC) industry, It is playing an important role in Failure Analysis (FA), circuit repair and Transmission Electron Microscopy (TEM) specimen preparation. In particular, preparation of TEM samples using FIB has become popular within the last ten years [1]; the progress in this field is well documented. Given the usefulness of FIB, “Artifact” however is a very sensitive issue in TEM inspections. The ability to identify those artifacts in TEM analysis is an important as to understanding the significance of pictures In this paper, we will describe how to measure the damages introduced by FIB sample preparation and introduce a better way to prevent such kind of artifacts.


Sign in / Sign up

Export Citation Format

Share Document