scholarly journals Cardiac Ambulatory Monitoring: New Wireless Device Validated Against Conventional Holter Monitoring in a Case Series

2020 ◽  
Vol 7 ◽  
Author(s):  
Srinivasan Murali ◽  
Nicolas Brugger ◽  
Francisco Rincon ◽  
Manoj Mashru ◽  
Stéphane Cook ◽  
...  

Background: Cardiac arrhythmias are very common but underdiagnosed due to their transient and asymptomatic nature. An optimization of arrhythmia detection would permit to better treat patients and could substantially reduce morbidity and mortality. The SmartCardia ScaAI wireless patch is a novel CE IIa approved, single-lead electrocardiographic (ECG) ambulatory monitor designed for cardiac arrhythmias detection.Hypothesis: The accuracy of the new SmartCardia wireless patch to detect arrhythmias is comparable to the conventional Holter monitoring.Methods: Patients referred for a suspicion of arrhythmia between February and March 2020 were included in the trial. Simultaneous ambulatory ECG were recorded using a conventional 24-h Holter and the SmartCardia. The primary endpoint was the detection of cardiac arrhythmias over the total wear time of the devices, defined as premature atrial contraction (PAC), supraventricular tachycardia ≥3 beats, premature ventricular contraction (PVC), and ventricular tachycardia ≥3 beats. Conduction abnormalities, pause ≥2 s and atrioventricular block (AVB), were also tracked. McNemar's test was used to compare the matched pairs of data from both devices.Results: A total of 40 patients were included in the trial. Over the total wear time, there was no significant difference between the devices for ventricular and supraventricular arrhythmias detection. Pauses and AVB were equally identified by the two devices in three patients.Conclusion: Over the total wear time, the SmartCardia device showed an accuracy to detect arrhythmia similar to the 24-h Holter monitoring: single-lead, adhesive-patch monitoring might become an interesting alternative to the conventional Holter monitoring.

2021 ◽  
Vol 9 (B) ◽  
pp. 12-17
Author(s):  
Lidija Poposka ◽  
Marija Vavlukis ◽  
Hristo Pejkov ◽  
Marjan Gusev

AIM: The aim of the study was to show non-inferiority of the single-channel ECGalert system to the gold standard (ECG Holter) in the detection of arrhythmias over the total wear time of both devices. METHODS: A prospective study enrolled a total of 165 patients hospitalized at the University Clinic of Cardiology, who underwent simultaneous single-channel ECG recording with ECGAlert system and a conventional 24 h Holter monitor on the 1st day and continued ECGAlert monitoring for few more days, under assignment of the doctor or at the wish of the patient. RESULTS: A total of 165 patients were included in the study, 61.2% male, mean age of 58.4 ± 12.7 years. Mean duration of ECG Holter monitoring was 23.2 ± 0.5 h and mean duration of ECGalert/Savvy monitoring was 64.6 ± 31.2. During the first 24 h of simultaneous ECG monitoring with both methods, no statistically significant difference was found in arrhythmia detection. Over the total wear time of both devices, the ECGalert system detected significantly more AF episodes as compared to Holter (p < 0.000). ECGalert demonstrated significantly lower detection rate of false pauses (0.001). However, false detection of episodes of VT or AF was significantly higher in ECGalert system versus Holter (p < 0.000 and p < 0.000 respectively). Patients were more satisfied with ECGalert system, due to lesser interference in daily activities. CONCLUSION: The ECGalert system demonstrated superiority over traditional Holter monitoring in arrhythmia detection in the total monitoring period, but not in the first 24 h.


2020 ◽  
Vol 41 (6) ◽  
pp. 436-441 ◽  
Author(s):  
Daniel A. Rosloff ◽  
Kunal Patel ◽  
Paul J. Feustel ◽  
Jocelyn Celestin

Background: Undifferentiated somatoform (US) idiopathic anaphylaxis (IA) is considered a psychogenic disorder characterized by a lack of observable physical findings and poor response to treatment. Although failure to diagnose true anaphylaxis can have disastrous consequences, identification of US-IA is crucial to limit unnecessary expenses and use of health care resources. Objective: To better define the presentation and understand the potential relationship between US-IA and underlying psychiatric comorbidities. Methods: We retrospectively reviewed 110 visits by 107 patients to our institution for evaluation and management of anaphylaxis over a 1-year period. The patients were classified as having either criteria positive (CP) or criteria negative (CN) anaphylaxis based on whether they met Second National Institute of Allergy and Infectious Disease/Food Allergy and Anaphylaxis Network Symposium criteria for the clinical diagnosis of anaphylaxis. Patient characteristics, including objective and subjective signs and symptoms, and the presence of psychiatric diagnoses were collected and analyzed. Statistical significance was assessed by using the Fisher exact test. A literature review of US-IA and other psychogenic forms of anaphylaxis was performed. Results: Patients with CP anaphylaxis were more likely to present with hypotension, wheezing, urticaria, and vomiting than were patients with CN anaphylaxis. The patients with CN anaphylaxis were more likely to present with subjective symptoms of sensory throat tightness or swelling compared with patients with CP anaphylaxis. No significant difference was detected in the prevalence of psychiatric conditions between the two groups. Conclusion: Patients who met previously established diagnostic criteria for anaphylaxis were more likely to present with objective physical findings than those who did not meet criteria for true anaphylaxis. CN patients who presented for treatment of anaphylaxis were more likely to present with subjective symptoms. Formal diagnostic criteria should be used by clinicians when evaluating patients with suspected anaphylaxis.


2020 ◽  
Vol 132 (4) ◽  
pp. 1188-1196 ◽  
Author(s):  
Tobias Greve ◽  
Veit M. Stoecklein ◽  
Franziska Dorn ◽  
Sophia Laskowski ◽  
Niklas Thon ◽  
...  

OBJECTIVEIntraoperative neuromonitoring (IOM), particularly of somatosensory-evoked potentials (SSEPs) and motor-evoked potentials (MEPs), evolved as standard of care in a variety of neurosurgical procedures. Case series report a positive impact of IOM for elective microsurgical clipping of unruptured intracranial aneurysms (ECUIA), whereas systematic evaluation of its predictive value is lacking. Therefore, the authors analyzed the neurological outcome of patients undergoing ECUIA before and after IOM introduction to this procedure.METHODSThe dates of inclusion in the study were 2007–2014. In this period, ECUIA procedures before (n = 136, NIOM-group; 2007–2010) and after introduction of IOM (n = 138, IOM-group; 2011–2014) were included. The cutoff value for SSEP/MEP abnormality was chosen as an amplitude reduction ≥ 50%. SSEP/MEP changes were correlated with neurological outcome. IOM-undetectable deficits (bulbar, vision, ataxia) were not included in risk stratification.RESULTSThere was no significant difference in sex distribution, follow-up period, subarachnoid hemorrhage risk factors, aneurysm diameter, complexity, and location. Age was higher in the IOM-group (57 vs 54 years, p = 0.012). In the IOM group, there were 18 new postoperative deficits (13.0%, 5.8% permanent), 9 hemisyndromes, 2 comas, 4 bulbar symptoms, and 3 visual deficits. In the NIOM group there were 18 new deficits (13.2%; 7.3% permanent, including 7 hemisyndromes). The groups did not significantly differ in the number or nature of postoperative deficits, nor in their recovery rate. In the IOM group, SSEPs and MEPs were available in 99% of cases. Significant changes were noted in 18 cases, 4 of which exhibited postoperative hemisyndrome, and 1 suffered from prolonged comatose state (5 true-positive cases). Twelve patients showed no new detectable deficits (false positives), however 2 of these cases showed asymptomatic infarction. Five patients with new hemisyndrome and 1 comatose patient did not show significant SSEP/MEP alterations (false negatives). Overall sensitivity of SSEP/MEP monitoring was 45.5%, specificity 89.8%, positive predictive value 27.8%, and negative predictive value 95.0%.CONCLUSIONSThe assumed positive impact of introducing SSEP/MEP monitoring on overall neurological outcome in ECUIA did not reach significance. This study suggests that from a medicolegal point of view, IOM is not stringently required in all neurovascular procedures. However, future studies should carefully address high-risk patients with complex procedures who might benefit more clearly from IOM than others.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Hun Lee ◽  
Jae Lim Chung ◽  
Young Jun Kim ◽  
Jae Yong Kim ◽  
Hungwon Tchah

AbstractWe aimed to compare the refractive outcomes of cataract surgery with diffractive multifocal intraocular lenses (IOLs) using standard keratometry (K) and total keratometry (TK). In this retrospective observational case series study, a total of 302 patients who underwent cataract surgery with multifocal IOL implantation were included. Predicted refractive outcomes were calculated based on the current standard formulas and a new formula developed for TK using K and TK, which were obtained from a swept-source optical biometer. At 2-month postoperatively, median absolute prediction errors (MedAEs) and proportion of eyes within ± 0.50 diopters (D) of predicted postoperative spherical equivalent (SE) refraction were analyzed. There was no significant difference between MedAEs or proportion of eyes within ± 0.50D of predicted refraction from K and TK in each formula. In TFNT00 and 839MP IOL cases, there was no difference between MedAEs from K and TK using any formula. In 829MP IOL cases, MedAE from TK was significantly larger than that from K in Barrett Universal II/Barrett TK Universal II (P = 0.033). In 677MY IOL cases, MedAE from TK was significantly larger than that from K in Haigis (P = 0.020) and Holladay 2 (P = 0.006) formulas. In the subgroup analysis for IOL, there was no difference between the proportion of eyes within ± 0.50 D of predicted refraction from K and TK using any formula. TFNT00 and 839MP IOLs were favorable with TK, with 677MY IOL with K and 829MP IOL being in a neutral position, which necessitates the study that investigates the accuracy of the new TK technology.


2017 ◽  
Vol 38 (5) ◽  
pp. 485-495 ◽  
Author(s):  
Riccardo D’Ambrosi ◽  
Camilla Maccario ◽  
Chiara Ursino ◽  
Nicola Serra ◽  
Federico Giuseppe Usuelli

Background: The purpose of this study was to evaluate the clinical and radiologic outcomes of patients younger than 20 years, treated with the arthroscopic-talus autologous matrix-induced chondrogenesis (AT-AMIC) technique and autologous bone graft for osteochondral lesion of the talus (OLT). Methods: Eleven patients under 20 years (range 13.3-20.0) underwent the AT-AMIC procedure and autologous bone graft for OLTs. Patients were evaluated preoperatively (T0) and at 6 (T1), 12 (T2), and 24 (T3) months postoperatively, using the American Orthopaedic Foot & Ankle Society Ankle and Hindfoot (AOFAS) score, the visual analog scale and the SF-12 respectively in its Mental and Physical Component Scores. Radiologic assessment included computed tomographic (CT) scan, magnetic resonance imaging (MRI) and intraoperative measurement of the lesion. A multivariate statistical analysis was performed. Results: Mean lesion size measured during surgery was 1.1 cm3 ± 0.5 cm3. We found a significant difference in clinical and radiologic parameters with analysis of variance for repeated measures ( P < .001). All clinical scores significantly improved ( P < .05) from T0 to T3. Lesion area significantly reduced from 119.1 ± 29.1 mm2 preoperatively to 77.9 ± 15.8 mm2 ( P < .05) at final follow-up as assessed by CT, and from 132.2 ± 31.3 mm2 to 85.3 ± 14.5 mm2 ( P < .05) as assessed by MRI. Moreover, we noted an important correlation between intraoperative size of the lesion and body mass index (BMI) ( P = .011). Conclusions: The technique can be considered safe and effective with early good results in young patients. Moreover, we demonstrated a significant correlation between BMI and lesion size and a significant impact of OLTs on quality of life. Level of Evidence: Level IV, retrospective case series.


Sensors ◽  
2021 ◽  
Vol 21 (9) ◽  
pp. 3235
Author(s):  
Koichi Fujiwara ◽  
Shota Miyatani ◽  
Asuka Goda ◽  
Miho Miyajima ◽  
Tetsuo Sasano ◽  
...  

Heart rate variability, which is the fluctuation of the R-R interval (RRI) in electrocardiograms (ECG), has been widely adopted for autonomous evaluation. Since the HRV features that are extracted from RRI data easily fluctuate when arrhythmia occurs, RRI data with arrhythmia need to be modified appropriately before HRV analysis. In this study, we consider two types of extrasystoles—premature ventricular contraction (PVC) and premature atrial contraction (PAC)—which are types of extrasystoles that occur every day, even in healthy persons who have no cardiovascular diseases. A unified framework for ectopic RRI detection and a modification algorithm that utilizes an autoencoder (AE) type of neural network is proposed. The proposed framework consists of extrasystole occurrence detection from the RRI data and modification, whose targets are PVC and PAC. The RRI data are monitored by means of the AE in real time in the detection phase, and a denoising autoencoder (DAE) modifies the ectopic RRI caused by the detected extrasystole. These are referred to as AE-based extrasystole detection (AED) and DAE-based extrasystole modification (DAEM), respectively. The proposed framework was applied to real RRI data with PVC and PAC. The result showed that AED achieved a sensitivity of 93% and a false positive rate of 0.08 times per hour. The root mean squared error of the modified RRI decreased to 31% in PVC and 73% in PAC from the original RRI data by DAEM. In addition, the proposed framework was validated through application to a clinical epileptic seizure problem, which showed that it correctly suppressed the false positives caused by PVC. Thus, the proposed framework can contribute to realizing accurate HRV-based health monitoring and medical sensing systems.


Author(s):  
Anna K. Dietl ◽  
Matthias W. Beckmann ◽  
Konrad Aumann

Abstract Purpose Villoglandular adenocarcinoma (VGA) of the uterine cervix has been classified as a rare subtype of cervical adenocarcinoma with good prognosis. A conservative surgical approach is considered feasible. The main risk factor is the presence of other histologic types of cancer. In this largest systematic review to date, we assess oncological outcomes associated with conservative therapy compared to those associated with invasive management in the treatment of stage Ia and Ib1 VGA. Methods Case series and case reports identified by searching the PubMed database were eligible for inclusion in this review (stage Ia–Ib1). Results A total of 271 patients were included in our literature review. 54 (20%) patients were treated by “conservative management” (conization, simple hysterectomy, and trachelectomy) and 217 (80%) by “invasive management” (radical hysterectomy ± radiation, hysterectomy, and radiation). Recurrences of disease (RODs) were found in the conservative group in two (4%) cases and in the invasive group in nine (4%) cases. There was no significant difference in disease-free survival (DFS) according to conservative or invasive treatment (p = 0.75). The histology of VGA may be complex with underlying usual adenocarcinoma (UAC) combined with VGA. Conclusion The excellent prognosis of pure VGA and the young age of the patients may justify the management of this tumor using a less radical procedure. The histological diagnosis of VGA is a challenge, and pretreatment should not be based solely on a simple punch biopsy but rather a conization with wide tumor-free margins.


Author(s):  
Julien Favresse ◽  
Jean-Louis Bayart ◽  
Damien Gruson ◽  
Sergio Bernardini ◽  
Aldo Clerico ◽  
...  

Abstract Cardiac troponins (cTn) are the preferred biomarkers for the evaluation of myocardial injury and play a key role in the diagnosis of acute myocardial infarction (MI). Pre-analytical or analytical issues and interferences affecting troponin T and I assays are therefore of major concern given the risk of misdiagnosis. False positive troponin results have been related to various interferences including anti-troponin antibodies, heterophilic antibodies, or elevated alkaline phosphatase level. On the other hand, false negative results have been reported in the case of a large biotin intake. These interferences are characterized with erroneous but reproducible troponin results. Of interest, non-reproducible results have also been reported in the literature. In other words, if the sample is reanalyzed a second time, a significant difference in troponin results will be observed. These interferences have been named “fliers” or “outliers”. Compared to the biotin interference that received major attention in the literature, troponin outliers are also able to induce harmful clinical consequences for the patient. Moreover, the prevalence of outliers in recent studies was found to be higher (0.28–0.57%) compared to the biotin interference. The aim of this systematic review is to warn clinicians about these non-reproducible results that may alter their clinical judgment. Four case reports that occurred in the Clinique of Saint-Luc Bouge are presented to attest this point. Moreover, we aimed at identifying the nature of these non-reproducible troponin results, determining their occurrence, and describing the best way for their identification.


2021 ◽  
Author(s):  
Jonathan P Scoville ◽  
Evan Joyce ◽  
Joshua Hunsaker ◽  
Jared Reese ◽  
Herschel Wilde ◽  
...  

Abstract BACKGROUND Minimally invasive surgery (MIS) has been shown to decrease length of hospital stay and opioid use. OBJECTIVE To identify whether surgery for epilepsy mapping via MIS stereotactically placed electroencephalography (SEEG) electrodes decreased overall opioid use when compared with craniotomy for EEG grid placement (ECoG). METHODS Patients who underwent surgery for epilepsy mapping, either SEEG or ECoG, were identified through retrospective chart review from 2015 through 2018. The hospital stay was separated into specific time periods to distinguish opioid use immediately postoperatively, throughout the rest of the stay and at discharge. The total amount of opioids consumed during each period was calculated by transforming all types of opioids into their morphine equivalents (ME). Pain scores were also collected using a modification of the Clinically Aligned Pain Assessment (CAPA) scale. The 2 surgical groups were compared using appropriate statistical tests. RESULTS The study identified 43 patients who met the inclusion criteria: 36 underwent SEEG placement and 17 underwent craniotomy grid placement. There was a statistically significant difference in median opioid consumption per hospital stay between the ECoG and the SEEG placement groups, 307.8 vs 71.5 ME, respectively (P = .0011). There was also a significant difference in CAPA scales between the 2 groups (P = .0117). CONCLUSION Opioid use is significantly lower in patients who undergo MIS epilepsy mapping via SEEG compared with those who undergo the more invasive ECoG procedure. As part of efforts to decrease the overall opioid burden, these results should be considered by patients and surgeons when deciding on surgical methods.


Materials ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 3828
Author(s):  
Jung-Gu Ji ◽  
Jung-A Yu ◽  
Seong-Ho Choi ◽  
Dong-Woon Lee

Vertical ridge augmentation for long-term implant stability is difficult in severely resorbed areas. We examined the clinical, radiological, and histological outcomes of guided-bone regeneration using novel titanium-reinforced microporous expanded polytetrafluoroethylene (MP-ePTFE) membranes. Eighteen patients who underwent implant placement using a staged approach were enrolled (period: 2018–2019). Vertical ridge augmentation was performed in areas with vertical bone defects ≥ 4 mm. Twenty-six implant fixtures were placed in 14 patients. At implant placement six fixtures had relatively low stability. On cone-beam computed tomography, the average vertical changes were 4.2 ± 1.9 (buccal), 5.9 ± 2.7 (central), and 4.4 ± 2.8 mm (lingual) at six months after vertical ridge augmentation. Histomorphometric analyses revealed that the average proportions of new bone, residual bone substitute material, and soft tissue were 34.91 ± 11.61%, 7.16 ± 2.74%, and 57.93 ± 11.09%, respectively. Stable marginal bone levels were observed at 1-year post-loading. The residual bone graft material area was significantly lower in the exposed group (p = 0.003). There was no significant difference in the vertical height change in the buccal side between immediately after the augmentation procedure and the implant placement reentry time (p = 0.371). However, all implants functioned well regardless of the exposure during the observation period. Thus, vertical ridge augmentation around implants using titanium-reinforced MP-ePTFE membranes can be successful.