scholarly journals Comparison of a Point-of-Care Analyzer With a Chemiluminescent Immunoassay for Serum Progesterone Measurement in Breeding Management of the Bitch

2021 ◽  
Vol 8 ◽  
Author(s):  
Julia Zuercher ◽  
Katie M. Boes ◽  
Orsolya Balogh ◽  
Alyssa B. Helms ◽  
Julie T. Cecere

Accurate serum progesterone measurements for timing bitches during breeding management is critical for reproductive practice, especially as artificial insemination has become routine to facilitate breeding of animals that are geographically or temporally separated. To measure serum progesterone, chemiluminescent immunoassay (CLIA) has replaced radioimmunoassay as the current standard in the bitch due to its high correlation and increased practicality. In January 2019, a colorimetric point-of-care (POC) immunoassay for quantitative in-clinic canine serum progesterone measurements in <30 min was released. This study provides an independent comparison of the POC (Catalyst One, IDEXX) to the current industry standard, CLIA (Immulite-2000, Siemens). To assess inter-assay imprecision of POC and agreement of the POC and CLIA results, 100 canine serum samples were analyzed on three analyzers (POC-1, POC-2, and CLIA), of which, 74 (POC-1) and 75 (POC-2) results were within POCs' reportable range of 0.2–20 ng/mL and included in the study. To assess intra-assay imprecision, pooled canine serum samples at low (L1), intermediate (L2), and high (L3) progesterone concentrations were analyzed ten times each on POC-1 and CLIA. Relative to CLIA, POC values showed good correlation (POC-1, r2 = 0.9366; POC-2, r2 = 0.9438, P < 0.0001) and significant positive proportional bias at values >2 ng/mL. The POC inter-assay coefficients of variation (CVs) were 13.2% (0.2–2.9 ng/mL, 0.6–9.2 nmol/L, L1), 10.0% (3.0–9.9 ng/mL, 9.5–31.5 nmol/L, L2), 7.1% (10.0–20.0 ng/mL, 31.8–63.6 nmol/L, L3), and 11.2% (all samples). The intra-assay CVs for POC (L1, 15.3%; L2, 7.0%; L3, 4.7%) were higher than those for CLIA (L1, 5.89%; L2, 4.89%; L3, 3.44%). Based on the more rapid increase in serial serum progesterone concentrations in ovulating bitches and the greater imprecision of the POC, the clinical interpretations of serum progesterone measurements as they relate to canine breeding management should be made with caution.

2017 ◽  
Author(s):  
Bo Tian ◽  
Peter Svedlindh ◽  
Mattias Strömberg ◽  
Erik Wetterskog

In this work, we demonstrate for the first time, a ferromagnetic resonance (FMR) based homogeneous and volumetric biosensor for magnetic label detection. Two different isothermal amplification methods, <i>i.e.</i>, rolling circle amplification (RCA) and loop-mediated isothermal amplification (LAMP) are adopted and combined with a standard electron paramagnetic resonance (EPR) spectrometer for FMR biosensing. For RCA-based FMR biosensor, binding of RCA products of a synthetic Vibrio cholerae target DNA sequence gives rise to the formation of aggregates of magnetic nanoparticles. Immobilization of nanoparticles within the aggregates leads to a decrease of the net anisotropy of the system and a concomitant increase of the resonance field. A limit of detection of 1 pM is obtained with an average coefficient of variation of 0.16%, which is superior to the performance of other reported RCA-based magnetic biosensors. For LAMP-based sensing, a synthetic Zika virus target oligonucleotide is amplified and detected in 20% serum samples. Immobilization of magnetic nanoparticles is induced by their co-precipitation with Mg<sub>2</sub>P<sub>2</sub>O<sub>7</sub> (a by-product of LAMP) and provides a detection sensitivity of 100 aM. The fast measurement, high sensitivity and miniaturization potential of the proposed FMR biosensing technology makes it a promising candidate for designing future point-of-care devices.<br>


2019 ◽  
Vol 11 (1) ◽  
pp. 031
Author(s):  
C.S. Meghasree ◽  
G. Sudha ◽  
C.N. Darshan ◽  
B.M. Ravindranath ◽  
M. Navya ◽  
...  

Biosensors ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 157
Author(s):  
Bárbara V. M. Silva ◽  
Marli T. Cordeiro ◽  
Marco A. B. Rodrigues ◽  
Ernesto T. A. Marques ◽  
Rosa F. Dutra

Zika virus (ZIKV) is a mosquito-borne infection, predominant in tropical and subtropical regions causing international concern due to the ZIKV disease having been associated with congenital disabilities, especially microcephaly and other congenital abnormalities in the fetus and newborns. Development of strategies that minimize the devastating impact by monitoring and preventing ZIKV transmission through sexual intercourse, especially in pregnant women, since no vaccine is yet available for the prevention or treatment, is critically important. ZIKV infection is generally asymptomatic and cross-reactivity with dengue virus (DENV) is a global concern. An innovative screen-printed electrode (SPE) was developed for amperometric detection of the non-structural protein (NS2B) of ZIKV by exploring the intrinsic redox catalytic activity of Prussian blue (PB), incorporated into a carbon nanotube–polypyrrole composite. Thus, this immunosensor has the advantage of electrochemical detection without adding any redox-probe solution (probe-less detection), allowing a point-of-care diagnosis. It was responsive to serum samples of only ZIKV positive patients and non-responsive to negative ZIKV patients, even if the sample was DENV positive, indicating a possible differential diagnosis between them by NS2B. All samples used here were confirmed by CDC protocols, and immunosensor responses were also checked in the supernatant of C6/36 and in Vero cell cultures infected with ZIKV.


Diagnostics ◽  
2020 ◽  
Vol 11 (1) ◽  
pp. 9
Author(s):  
Meysam Rezaei ◽  
Sajad Razavi Bazaz ◽  
Sareh Zhand ◽  
Nima Sayyadi ◽  
Dayong Jin ◽  
...  

The recent outbreak of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and its associated serious respiratory disease, coronavirus disease 2019 (COVID-19), poses a major threat to global public health. Owing to the lack of vaccine and effective treatments, many countries have been overwhelmed with an exponential spread of the virus and surge in the number of confirmed COVID-19 cases. Current standard diagnostic methods are inadequate for widespread testing as they suffer from prolonged turn-around times (>12 h) and mostly rely on high-biosafety-level laboratories and well-trained technicians. Point-of-care (POC) tests have the potential to vastly improve healthcare in several ways, ranging from enabling earlier detection and easier monitoring of disease to reaching remote populations. In recent years, the field of POC diagnostics has improved markedly with the advent of micro- and nanotechnologies. Due to the COVID-19 pandemic, POC technologies have been rapidly innovated to address key limitations faced in existing standard diagnostic methods. This review summarizes and compares the latest available POC immunoassay, nucleic acid-based and clustered regularly interspaced short palindromic repeats- (CRISPR)-mediated tests for SARS-CoV-2 detection that we anticipate aiding healthcare facilities to control virus infection and prevent subsequent spread.


Viruses ◽  
2021 ◽  
Vol 13 (7) ◽  
pp. 1244
Author(s):  
Iulia Nedelcu ◽  
Raluca Jipa ◽  
Roxana Vasilescu ◽  
Cristian Băicuș ◽  
Costin-Ioan Popescu ◽  
...  

The number of serological assays for SARS-CoV-2 has skyrocketed in the past year. Concerns have been raised regarding their performance characteristics, depending on the disease severity and the time of the analysis post-symptom onset (PSO). Thus, independent validations using an unbiased sample selection are required for meaningful serology data interpretation. We aimed to assess the clinical performance of six commercially available assays, the seroconversion, and the dynamics of the humoral response to SARS-CoV-2 infection. The study included 528 serum samples from 156 patients with follow-up visits up to six months PSO and 161 serum samples from healthy people. The IgG/total antibodies positive percentage increased and remained above 95% after six months when chemiluminescent immunoassay (CLIA) IgG antiS1/S2 and electro-chemiluminescent assay (ECLIA) total antiNP were used. At early time points PSO, chemiluminescent microparticle immunoassay (CMIA) IgM antiS achieved the best sensitivity. IgM and IgG appear simultaneously in most circumstances, and when performed in parallel the sensitivity increases. The severe and the moderate clinical forms were significantly associated with higher seropositivity percentage and antibody levels. High specificity was found in all evaluated assays, but the sensitivity was variable depending on the time PSO, severity of disease, detection method and targeted antigen.


Author(s):  
K. Albrecht ◽  
J. Lotz ◽  
L. Frommer ◽  
K. J. Lackner ◽  
G. J. Kahaly

Abstract Purpose Vitamin D (VitD) is a pleiotropic hormone with effects on a multitude of systems and metabolic pathways. Consequently, the relevance of a sufficiently high VitD serum level becomes self-evident. Methods A rapid immunofluorescence assay designed for the point-of-care measurement of serum VitD3 solely was tested. Inter- and intra-assay validation, double testing and result comparison with a standardized laboratory method were performed. Results An overall linear correlation of r = 0.89 (Pearson, 95% CI 0.88–0.92, p < 0.01) between the point of care and the conventional reference assay was registered. Accuracy and precision were of special interest at cut-points (10 ng/ml [mean deviation 1.7 ng/ml, SD 1.98 ng/ml, SE 0.16 ng/ml], 12 ng/ml [MD 0.41, SD 1.89, SE 0.19] and 30 ng/ml [MD − 1.11, SD 3.89, SE 0.35]). Only a slight deviation was detected between the two assays when using fresh (r = 0.91, 95% CI 0.86–0.94, p < 0.01) and frozen serum samples (r = 0.86, 0.82–0.89, p < 0.01). Results remained steady when samples were frozen several times. Inter- and intra-assay validation according to the CLSI protocol as well as multiuser testing showed stable results. Conclusion This novel, innovative, and controlled study indicates that the evaluated rapid point of care VitD assay is reliable, accurate, and suited for clinical practice.


2003 ◽  
Vol 47 (1) ◽  
pp. 124-129 ◽  
Author(s):  
Sylvie Larrat ◽  
Françoise Stanke-Labesque ◽  
Agnès Plages ◽  
Jean-Pierre Zarski ◽  
Germain Bessard ◽  
...  

ABSTRACT Ribavirin in combination with alpha 2 interferon is the consensus treatment for chronic hepatitis C. However, recent preliminary pharmacological studies have suggested that the bioavailability of ribavirin displays great interindividual variability. In order to monitor serum ribavirin levels during combination treatment, we developed and validated a quantitative assay using an approach adaptable for routine hospital laboratories. The method involved solid-phase extraction on phenyl boronic acid cartridges followed by high-performance liquid chromatography with a C18-bonded silica column and a mobile phase containing 10 mM ammonium phosphate buffer (with the pH adjusted to 2.5) and UV detection (207 nm). The sensitivity, recovery, linearity of the calibration curve, intra- and interassay accuracies, precision, and stability at 4°C were consistent with its use in the laboratory routine. In addition, other nucleoside analogues sometimes used with ribavirin in patients coinfected with hepatitis C virus (HCV) and human immunodeficiency virus did not interfere with the quantification of ribavirin levels. The ribavirin concentration was quantified in 24 serum samples from patients with chronic hepatitis C treated with a combination of ribavirin and alpha 2 interferon. The mean serum ribavirin concentration was 2.67 ± 1.06 μg/ml (n = 24) at week 12 of treatment (W12) and 3.24 ± 1.35 μg/ml (n = 24) at week 24 of treatment (W24). In addition, ribavirin concentrations displayed high interindividual variabilities: the coefficients of variation of the serum ribavirin concentrations adjusted to the administered dose were 44 and 48% at W12 and W24, respectively. Moreover, the ribavirin concentration was higher in patients with a sustained virological response (n = 11) than in patients with treatment failure (n = 13), with significant intergroup differences at W12 (P = 0.030) and W24 (P = 0.049). The present study describes a simple analytical method for the quantification of ribavirin in human serum that could be a useful tool for the monitoring of ribavirin concentrations in HCV-infected patients in order to improve the efficacy and safety of therapy with ribavirin plus interferon.


2015 ◽  
Vol 407 (7) ◽  
pp. 1973-1980 ◽  
Author(s):  
Lei Zheng ◽  
Jing Wang ◽  
Yufen Wang ◽  
Zhaorui Song ◽  
Yaqing Dong ◽  
...  

2021 ◽  
Vol 14 (3) ◽  
pp. 585-588
Author(s):  
Nutnaree Kunanusont ◽  
Darsaniya Punyadarsaniya ◽  
Sakchai Ruenphet

Background and Aim: The concentration of serum progesterone is commonly used to determine the optimal mating time in bitches, and to diagnose reproductive-related abnormalities. This study aims to compare the serum progesterone results obtained by rapid fluorescence immunochromatography assay (RFICA) with those obtained by chemiluminescent microparticle immunoassay (CMIA) from the same serum samples to develop a standard guideline for optimal breeding time. Materials and Methods: Serum progesterone levels were measured in 124 bitches using RFICA and CMIA. Simple linear regression and correlation analyses were performed to analyze the data. The percentage difference between the maximum and minimum progesterone values in the same serum sample in the same assay was compared using Wilcoxon's rank-sum test. Results: The present study showed a strong linear dependence of the results obtained by RFICA on those obtained by CMIA as R2=0.8976, with regression coefficient of 0.9474 and p<0.05, including the regression model was CMIA = (0.9483 × RFICA) - 0.761. Moreover, five critical measurement times during estrous in bitches showed statistically significant differences (p<0.05), except at the fertilizable period, which showed a non-significant difference (p>0.05). Conclusion: This study demonstrated that it is presumably acceptable to use the RFICA and CMIA methods interchangeably for quality progesterone measurements in serum samples from bitches. However, when considering the use of the RFICA method, it is advisable to carefully interpret the results and follow the interpretation guidelines. Finally, RFICA in the present study provides a reliable and convenient option for veterinarian practitioners to measure canine progesterone levels in-house.