scholarly journals Recent Advances in Single-Particle Electron Microscopic Analysis of Autophagy Degradation Machinery

2020 ◽  
Vol 21 (21) ◽  
pp. 8051
Author(s):  
Yiu Wing Sunny Cheung ◽  
Sung-Eun Nam ◽  
Calvin K. Yip

Macroautophagy (also known as autophagy) is a major pathway for selective degradation of misfolded/aggregated proteins and damaged organelles and non-selective degradation of cytoplasmic constituents for the generation of power during nutrient deprivation. The multi-step degradation process, from sequestering cytoplasmic cargo into the double-membrane vesicle termed autophagosome to the delivery of the autophagosome to the lysosome or lytic vacuole for breakdown, is mediated by the core autophagy machinery composed of multiple Atg proteins, as well as the divergent sequence family of selective autophagy receptors. Single-particle electron microscopy (EM) is a molecular imaging approach that has become an increasingly important tool in the structural characterization of proteins and macromolecular complexes. This article summarizes the contributions single-particle EM have made in advancing our understanding of the core autophagy machinery and selective autophagy receptors. We also discuss current technical challenges and roadblocks, as well as look into the future of single-particle EM in autophagy research.

2009 ◽  
Vol 20 (17) ◽  
pp. 3828-3839 ◽  
Author(s):  
Taras Y. Nazarko ◽  
Jean-Claude Farré ◽  
Suresh Subramani

Autophagy is a major pathway of intracellular degradation mediated by formation of autophagosomes. Recently, autophagy was implicated in the degradation of intracellular bacteria, whose size often exceeds the capacity of normal autophagosomes. However, the adaptations of the autophagic machinery for sequestration of large cargos were unknown. Here we developed a yeast model system to study the effect of cargo size on the requirement of autophagy-related (Atg) proteins. We controlled the size of peroxisomes before their turnover by pexophagy, the selective autophagy of peroxisomes, and found that peroxisome size determines the requirement of Atg11 and Atg26. Small peroxisomes can be degraded without these proteins. However, Atg26 becomes essential for degradation of medium peroxisomes. Additionally, the pexophagy-specific phagophore assembly site, organized by the dual interaction of Atg30 with functionally active Atg11 and Atg17, becomes essential for degradation of large peroxisomes. In contrast, Atg28 is partially required for all autophagy-related pathways independent of cargo size, suggesting it is a component of the core autophagic machinery. As a rule, the larger the cargo, the more cargo-specific Atg proteins become essential for its sequestration.


2012 ◽  
Vol 34 (2) ◽  
pp. 24-30 ◽  
Author(s):  
Doris Popovic ◽  
Ivan Dikic

Autophagy is an evolutionarily conserved intracellular degradation process, through which large cellular cargos are sequestered into double-membrane vesicles (autophagosomes) and delivered to the lysosome. Starvation-induced autophagy represents a general non-selective degradation pathway that breaks down cellular components for energy replenishment. Alternatively, selective autophagy targets specific organelles, protein aggregates or invading pathogens that need to be precisely removed from the cell during development or pathogenic infection. Selective autophagy receptors noncovalently bind to the family of ATG8 modifiers and can be controlled by post-translational protein modifications, including ubiquitination and phosphorylation. In this article, we review recent advances in our understanding of the molecular basis of cargo selection in autophagy.


Cells ◽  
2019 ◽  
Vol 8 (12) ◽  
pp. 1627 ◽  
Author(s):  
Louis Tung Faat Lai ◽  
Hao Ye ◽  
Wenxin Zhang ◽  
Liwen Jiang ◽  
Wilson Chun Yu Lau

Autophagy is a highly regulated bulk degradation process that plays a key role in the maintenance of cellular homeostasis. During autophagy, a double membrane-bound compartment termed the autophagosome is formed through de novo nucleation and assembly of membrane sources to engulf unwanted cytoplasmic components and targets them to the lysosome or vacuole for degradation. Central to this process are the autophagy-related (ATG) proteins, which play a critical role in plant fitness, immunity, and environmental stress response. Over the past few years, cryo-electron microscopy (cryo-EM) and single-particle analysis has matured into a powerful and versatile technique for the structural determination of protein complexes at high resolution and has contributed greatly to our current understanding of the molecular mechanisms underlying autophagosome biogenesis. Here we describe the plant-specific ATG proteins and summarize recent structural and mechanistic studies on the protein machinery involved in autophagy initiation with an emphasis on those by single-particle analysis.


2014 ◽  
Vol 206 (3) ◽  
pp. 357-366 ◽  
Author(s):  
Chao-Wen Wang ◽  
Yu-Hsuan Miao ◽  
Yi-Shun Chang

Stationary phase (stat-phase) is a poorly understood physiological state under which cells arrest proliferation and acquire resistance to multiple stresses. Lipid droplets (LDs), organelles specialized for cellular lipid homeostasis, increase in size and number at the onset of stat-phase. However, little is known about the dynamics of LDs under this condition. In this paper, we reveal the passage of LDs from perinuclear endoplasmic reticulum association to entry into vacuoles during the transition to stat-phase. We show that the process requires the core autophagy machinery and a subset of autophagy-related (Atg) proteins involved in selective autophagy. Notably, the process that we term stat-phase lipophagy is mediated through a sterol-enriched vacuolar microdomain whose formation and integrity directly affect LD translocation. Intriguingly, cells defective in stat-phase lipophagy showed disrupted vacuolar microdomains, implying that LD contents, likely sterol esters, contribute to the maintenance of vacuolar microdomains. Together, we propose a feed-forward loop in which lipophagy stimulates vacuolar microdomain formation, which in turn promotes lipophagy during stat-phase.


Author(s):  
J. Frank ◽  
P.-Y. Sizaret ◽  
A. Verschoor ◽  
J. Lamy

The accuracy with which the attachment site of immunolabels bound to macromolecules may be localized in electron microscopic images can be considerably improved by using single particle averaging. The example studied in this work showed that the accuracy may be better than the resolution limit imposed by negative staining (∽2nm).The structure used for this demonstration was a halfmolecule of Limulus polyphemus (LP) hemocyanin, consisting of 24 subunits grouped into four hexamers. The top view of this structure was previously studied by image averaging and correspondence analysis. It was found to vary according to the flip or flop position of the molecule, and to the stain imbalance between diagonally opposed hexamers (“rocking effect”). These findings have recently been incorporated into a model of the full 8 × 6 molecule.LP hemocyanin contains eight different polypeptides, and antibodies specific for one, LP II, were used. Uranyl acetate was used as stain. A total of 58 molecule images (29 unlabelled, 29 labelled with antl-LPII Fab) showing the top view were digitized in the microdensitometer with a sampling distance of 50μ corresponding to 6.25nm.


Author(s):  
F.J. Sjostrand

In the 1940's and 1950's electron microscopy conferences were attended with everybody interested in learning about the latest technical developments for one very obvious reason. There was the electron microscope with its outstanding performance but nobody could make very much use of it because we were lacking proper techniques to prepare biological specimens. The development of the thin sectioning technique with its perfectioning in 1952 changed the situation and systematic analysis of the structure of cells could now be pursued. Since then electron microscopists have in general become satisfied with the level of resolution at which cellular structures can be analyzed when applying this technique. There has been little interest in trying to push the limit of resolution closer to that determined by the resolving power of the electron microscope.


Author(s):  
T. Kanetaka ◽  
M. Cho ◽  
S. Kawamura ◽  
T. Sado ◽  
K. Hara

The authors have investigated the dissolution process of human cholesterol gallstones using a scanning electron microscope(SEM). This study was carried out by comparing control gallstones incubated in beagle bile with gallstones obtained from patients who were treated with chenodeoxycholic acid(CDCA).The cholesterol gallstones for this study were obtained from 14 patients. Three control patients were treated without CDCA and eleven patients were treated with CDCA 300-600 mg/day for periods ranging from four to twenty five months. It was confirmed through chemical analysis that these gallstones contained more than 80% cholesterol in both the outer surface and the core.The specimen were obtained from the outer surface and the core of the gallstones. Each specimen was attached to alminum sheet and coated with carbon to 100Å thickness. The SEM observation was made by Hitachi S-550 with 20 kV acceleration voltage and with 60-20, 000X magnification.


Author(s):  
Charlotte L. Ownby ◽  
David Cameron ◽  
Anthony T. Tu

In the United States the major health problem resulting from snakebite poisoning is local tissue damage, i.e. hemorrhage and myonecrosis. Since commercial antivenin does not usually prevent such damage to tissue, a more effective treatment of snakebite-induced myonecrosis is needed. To aid in the development of such a treatment the pathogenesis of myonecrosis induced by a pure component of rattlesnake venom was studied at the electron microscopic level.The pure component, a small (4,300 mol. wt.), basic (isoelectric point of 9.6) protein, was isolated from crude prairie rattlesnake (Crotalus viridis viridis) venom by gel filtration (Sephadex G-50) followed by cation exchange chromatography (Sephadex C-25), and shown to be pure by electrophoresis. Selection of the myotoxic component was based on light microscopic observations of injected mouse muscle.


Author(s):  
G.E. Visscher ◽  
R. L. Robison ◽  
G. J. Argentieri

The use of various bioerodable polymers as drug delivery systems has gained considerable interest in recent years. Among some of the shapes used as delivery systems are films, rods and microcapsules. The work presented here will deal with the techniques we have utilized for the analysis of the tissue reaction to and actual biodegradation of injectable microcapsules. This work has utilized light microscopic (LM), transmission (TEM) and scanning (SEM) electron microscopic techniques. The design of our studies has utilized methodology that would; 1. best characterize the actual degradation process without artifacts introduced by fixation procedures and 2. allow for reproducible results.In our studies, the gastrocnemius muscle of the rat was chosen as the injection site. Prior to the injection of microcapsules the skin above the sites was shaved and tattooed for later recognition and recovery. 1.0 cc syringes were loaded with the desired quantity of microcapsules and the vehicle (0.5% hydroxypropylmethycellulose) drawn up. The syringes were agitated to suspend the microcapsules in the injection vehicle.


Author(s):  
Ralph M. Albrecht ◽  
Scott R. Simmons ◽  
Marek Malecki

The development of video-enhanced light microscopy (LM) as well as associated image processing and analysis have significantly broadened the scope of investigations which can be undertaken using (LM). Interference/polarization based microscopies can provide high resolution and higher levels of “detectability” especially in unstained living systems. Confocal light microscopy also holds the promise of further improvements in resolution, fluorescence studies, and 3 dimensional reconstruction. Video technology now provides, among other things, a means to detect differences in contrast difficult to detect with the human eye; furthermore, computerized image capture, processing, and analysis can be used to enhance features of interest, average images, subtract background, and provide a quantitative basis to studies of cells, cell features, cell labelling, and so forth. Improvements in video technology, image capture, and cost-effective computer image analysis/processing have contributed to the utility and potential of the various interference and confocal microscopic instrumentation.Electron microscopic technology has made advances as well. Microprocessor control and improved design have contributed to high resolution SEMs which have imaging capability at the molecular level and can operate at a range of accelerating voltages starting at 1KV. Improvements have also been seen in the HVEM and IVEM transmission instruments. As a whole, these advances in LM and EM microscopic technology provide the biologist with an array of information on structure, composition, and function which can be obtained from a single specimen. Corrrelative light microscopic analysis permits examination of living specimens and is critical where the “history” of a cell, cellular components, or labels needs to be known up to the time of chemical or physical fixation. Features such as cytoskeletal elements or gold label as small as 0.01 μm, well below the 0.2 μm limits of LM resolution, can be “detected” and their movement followed by VDIC-LM. Appropriate identification and preparation can then lead to the examination of surface detail and surface label with stereo LV-HR-SEM. Increasing the KV in the HR-SEM while viewing uncoated or thinly coated specimens can provide information from beneath the surface as well as increasing Z contrast so that positive identification of surface and subsurface colloidal gold or other heavy metal labelled/stained material is possible. Further examination of the same cells using stereo HVEM or IVEM provides information on internal ultrastructure and on the relationship of labelled material to cytoskeletal or organellar distribution, A wide variety of investigations can benefit from this correlative approach and a number of instrumentational configurations and preparative pathways can be tailored for the particular study. For a surprisingly small investment in time and technique, it is often possible to clear ambiguities or questions that arise when a finding is presented in the context of only one modality.


Sign in / Sign up

Export Citation Format

Share Document