scholarly journals 3D Plotting of Silica/Collagen Xerogel Granules in an Alginate Matrix for Tissue-Engineered Bone Implants

Materials ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 830
Author(s):  
Sina Rößler ◽  
Andreas Brückner ◽  
Iris Kruppke ◽  
Hans-Peter Wiesmann ◽  
Thomas Hanke ◽  
...  

Today, materials designed for bone regeneration are requested to be degradable and resorbable, bioactive, porous, and osteoconductive, as well as to be an active player in the bone-remodeling process. Multiphasic silica/collagen Xerogels were shown, earlier, to meet these requirements. The aim of the present study was to use these excellent material properties of silica/collagen Xerogels and to process them by additive manufacturing, in this case 3D plotting, to generate implants matching patient specific shapes of fractures or lesions. The concept is to have Xerogel granules as active major components embedded, to a large proportion, in a matrix that binds the granules in the scaffold. By using viscoelastic alginate as matrix, pastes of Xerogel granules were processed via 3D plotting. Moreover, alginate concentration was shown to be the key to a high content of irregularly shaped Xerogel granules embedded in a minimum of matrix phase. Both the alginate matrix and Xerogel granules were also shown to influence viscoelastic behavior of the paste, as well as the dimensionally stability of the scaffolds. In conclusion, 3D plotting of Xerogel granules was successfully established by using viscoelastic properties of alginate as matrix phase.

2019 ◽  
Author(s):  
Zsuzsa Akos ◽  
Dona G. Isai ◽  
Sheeja Rajasingh ◽  
Edina Kosa ◽  
Saba Ghazvini ◽  
...  

AbstractThe material properties of tissues and their mechanical state is an important factor during development, disease, regenerative medicine and tissue engineering. Here we describe a microrheological measurement technique utilizing aggregates of microinjected ferromagnetic nickel particles to probe the viscoelastic properties of embryonic tissues. Quail embryos were cultured in a plastic incubator chamber located at the center of two pairs of crossed electromagnets. We estimate the Young’s modulus of the ECM-rich region separating the mesoderm and endoderm in Hamburger Hamilton stage 6-10 quail embryos as 300±100 Pa. We found a pronounced viscoelastic behavior consistent with a Zener (standard generalized solid) model. The viscoelastic response is about 45% of the total response, with a characteristic relaxation time of 1.3 sec.


2021 ◽  
Vol 10 (9) ◽  
pp. 1842
Author(s):  
Valentin Herber ◽  
Begüm Okutan ◽  
Georgios Antonoglou ◽  
Nicole G. Sommer ◽  
Michael Payer

Bone preservation and primary regeneration is a daily challenge in the field of dental medicine. In recent years, bioresorbable metals based on magnesium (Mg) have been widely investigated due to their bone-like modulus of elasticity, their high biocompatibility, antimicrobial, and osteoconductive properties. Synthetic Mg-based biomaterials are promising candidates for bone regeneration in comparison with other currently available pure synthetic materials. Different alloys based on Mg were developed to fit clinical requirements. In parallel, advances in additive manufacturing offer the possibility to fabricate experimentally bioresorbable metallic porous scaffolds. This review describes the promising clinical results of resorbable Mg-based biomaterials for bone repair in osteosynthetic application and discusses the perspectives of use in oral bone regeneration.


Mathematics ◽  
2021 ◽  
Vol 9 (15) ◽  
pp. 1746
Author(s):  
Iñigo Calderon-Uriszar-Aldaca ◽  
Sergio Perez ◽  
Ravi Sinha ◽  
Maria Camara-Torres ◽  
Sara Villanueva ◽  
...  

Additive manufacturing (AM) of scaffolds enables the fabrication of customized patient-specific implants for tissue regeneration. Scaffold customization does not involve only the macroscale shape of the final implant, but also their microscopic pore geometry and material properties, which are dependent on optimizable topology. A good match between the experimental data of AM scaffolds and the models is obtained when there is just a few millimetres at least in one direction. Here, we describe a methodology to perform finite element modelling on AM scaffolds for bone tissue regeneration with clinically relevant dimensions (i.e., volume > 1 cm3). The simulation used an equivalent cubic eight node finite elements mesh, and the materials properties were derived both empirically and numerically, from bulk material direct testing and simulated tests on scaffolds. The experimental validation was performed using poly(ethylene oxide terephthalate)-poly(butylene terephthalate) (PEOT/PBT) copolymers and 45 wt% nano hydroxyapatite fillers composites. By applying this methodology on three separate scaffold architectures with volumes larger than 1 cm3, the simulations overestimated the scaffold performance, resulting in 150–290% stiffer than average values obtained in the validation tests. The results mismatch highlighted the relevance of the lack of printing accuracy that is characteristic of the additive manufacturing process. Accordingly, a sensitivity analysis was performed on nine detected uncertainty sources, studying their influence. After the definition of acceptable execution tolerances and reliability levels, a design factor was defined to calibrate the methodology under expectable and conservative scenarios.


2015 ◽  
Vol 21 (6) ◽  
pp. 705-715 ◽  
Author(s):  
M. Fantini ◽  
F. De Crescenzio ◽  
L. Ciocca ◽  
F. Persiani

Purpose – The purpose of this paper is to describe two different approaches for manufacturing pre-formed titanium meshes to assist prosthetically guided bone regeneration of atrophic maxillary arches. Both methods are based on the use of additive manufacturing (AM) technologies and aim to limit at the minimal intervention the bone reconstructive surgery by virtual planning the surgical intervention for dental implants placement. Design/methodology/approach – Two patients with atrophic maxillary arches were scheduled for bone augmentation using pre-formed titanium mesh with particulate autogenous bone graft and alloplastic material. The complete workflow consists of four steps: three-dimensional (3D) acquisition of medical images and virtual planning, 3D modelling and design of the bone augmentation volume, manufacturing of biomodels and pre-formed meshes, clinical procedure and follow up. For what concerns the AM, fused deposition modelling (FDM) and direct metal laser sintering (DMLS) were used. Findings – For both patients, a post-operative control CT examination was scheduled to evaluate the progression of the regenerative process and verify the availability of an adequate amount of bone before the surgical intervention for dental implants placement. In both cases, the regenerated bone was sufficient to fix the implants in the planned position, improving the intervention quality and reducing the intervention time during surgery. Originality/value – A comparison between two novel methods, involving AM technologies are presented as viable and reproducible methods to assist the correct bone augmentation of atrophic patients, prior to implant placement for the final implant supported prosthetic rehabilitation.


e-Polymers ◽  
2020 ◽  
Vol 20 (1) ◽  
pp. 571-599
Author(s):  
Ricardo Donate ◽  
Mario Monzón ◽  
María Elena Alemán-Domínguez

AbstractPolylactic acid (PLA) is one of the most commonly used materials in the biomedical sector because of its processability, mechanical properties and biocompatibility. Among the different techniques that are feasible to process this biomaterial, additive manufacturing (AM) has gained attention recently, as it provides the possibility of tuning the design of the structures. This flexibility in the design stage allows the customization of the parts in order to optimize their use in the tissue engineering field. In the recent years, the application of PLA for the manufacture of bone scaffolds has been especially relevant, since numerous studies have proven the potential of this biomaterial for bone regeneration. This review contains a description of the specific requirements in the regeneration of bone and how the state of the art have tried to address them with different strategies to develop PLA-based scaffolds by AM techniques and with improved biofunctionality.


2021 ◽  
Vol 56 (18) ◽  
pp. 10707-10744
Author(s):  
Jonathan Torres ◽  
Ali P. Gordon

AbstractThe small punch test (SPT) was developed for situations where source material is scarce, costly or otherwise difficult to acquire, and has been used for assessing components with variable, location-dependent material properties. Although lacking standardization, the SPT has been employed to assess material properties and verified using traditional testing. Several methods exist for equating SPT results with traditional stress–strain data. There are, however, areas of weakness, such as fracture and fatigue approaches. This document outlines the history and methodologies of SPT, reviewing the body of contemporary literature and presenting relevant findings and formulations for correlating SPT results with conventional tests. Analysis of literature is extended to evaluating the suitability of the SPT for use with additively manufactured (AM) materials. The suitability of this approach is shown through a parametric study using an approximation of the SPT via FEA, varying material properties as would be seen with varying AM process parameters. Equations describing the relationship between SPT results and conventional testing data are presented. Correlation constants dictating these relationships are determined using an accumulation of data from the literature reviewed here, along with novel experimental data. This includes AM materials to assess the fit of these and provide context for a wider view of the methodology and its interest to materials science and additive manufacturing. A case is made for the continued development of the small punch test, identifying strengths and knowledge gaps, showing need for standardization of this simple yet highly versatile method for expediting studies of material properties and optimization.


2017 ◽  
Vol 37 (suppl_1) ◽  
Author(s):  
Qingyu Wang ◽  
Dalin Tang ◽  
Gador Canton ◽  
Jian Guo ◽  
Xiaoya Guo ◽  
...  

It is hypothesized that artery stiffness may be associated with plaque progression. However, in vivo vessel material stiffness follow-up data is lacking in the literature. In vivo 3D multi-contrast and Cine magnetic resonance imaging (MRI) carotid plaque data were acquired from 8 patients with follow-up (18 months) with written informed consent obtained. Cine MRI and 3D thin-layer models were used to determine parameter values of the Mooney-Rivlin models for the 81slices from 16 plaques (2 scans/patient) using our established iterative procedures. Effective Young’s Modulus (YM) values for stretch ratio [1.0,1.3] were calculated for each slice for analysis. Stress-stretch ratio curves from Mooney-Rivlin models for the 16 plaques and 81 slices are given in Fig. 1. Average YM value of the 81 slices was 411kPa. Slice YM values varied from 70 kPa (softest) to 1284 kPa (stiffest), a 1734% difference. Average slice YM values by vessel varied from 109 kPa (softest) to 922 kPa (stiffest), a 746% difference. Location-wise, the maximum slice YM variation rate within a vessel was 306% (139 kPa vs. 564 kPa). Average slice YM variation rate within a vessel for the 16 vessels was 134%. Average variation of YM values from baseline (T1) to follow up (T2) for all patients was 61.0%. The range of the variation of YM values was [-28.4%, 215%]. For progression study, YM increase (YMI=YM T2 -TM T1 ) showed negative correlation with plaque progression measured by wall thickness increase (WTI), (r= -0.6802, p=0.0634). YM T2 showed strong negative correlation with WTI (r= -0.7764, p=0.0235). Correlation between YM T1 and WTI was not significant (r= -0.4353, p= 0.2811). Conclusion In vivo carotid vessel material properties have large variations from patient to patient, along the vessel segment within a patient, and from baseline to follow up. Use of patient-specific, location specific and time-specific material properties could potentially improve the accuracy of model stress/strain calculations.


2004 ◽  
Vol 92 (2) ◽  
pp. 1236-1240 ◽  
Author(s):  
P. Grigg ◽  
D. R. Robichaud ◽  
Z. Del Prete

When skin is stretched, stimuli experienced by a cutaneous mechanoreceptor neuron are transmitted to the nerve ending through the skin. In these experiments, we tested the hypothesis that the viscoelastic response of the skin influences the dynamic response of cutaneous rapidly adapting (RA) neurons. Cutaneous RA afferent neurons were recorded in 3 species of mice (Tsk, Pallid, and C57BL6) whose skin has different viscoelastic properties. Isolated samples of skin and nerve were stimulated mechanically with a dynamic stretch stimulus, which followed a pseudo Gaussian waveform with a bandwidth of 0–60 Hz. The mechanical response of the skin was measured as were responses of single RA cutaneous mechanoreceptor neurons. For each neuron, the strength of association between spike responses and the dynamic and static components of stimuli were determined with multiple logistic regression analysis. The viscoelastic material properties of each skin sample were determined indirectly, by creating a nonlinear (Wiener–Volterra) model of the stress–strain relationship, and using the model to predict the complex compliance (i.e., the viscoelastic material properties). The dynamic sensitivity of RA mechanoreceptor neurons in mouse hairy skin was weakly related to the viscoelastic properties of the skin. Loss modulus and phase angle were lower (indicating a decreased viscous component of response) in Tsk and Pallid than in C57BL6 mice. However, RA mechanoreceptor neurons in Tsk and Pallid skin did not differ from those in C57 skin with regard to their sensitivity to the rate of change of stress or to the rate of change of incremental strain energy. They did have a decreased sensitivity to the rate of change of tensile strain. Thus the skin samples with lower dynamic mechanical response contained neurons with a somewhat lower sensitivity to dynamic stimuli.


2017 ◽  
Vol 7 (1) ◽  
Author(s):  
Dafydd O. Visscher ◽  
Maureen van Eijnatten ◽  
Niels P. T. J. Liberton ◽  
Jan Wolff ◽  
Mark B. M. Hofman ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document