scholarly journals Innovative Design Methodology for Patient-Specific Short Femoral Stems

Materials ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 442
Author(s):  
William Solórzano-Requejo ◽  
Carlos Ojeda ◽  
Andrés Díaz Lantada

The biomechanical performance of hip prostheses is often suboptimal, which leads to problems such as strain shielding, bone resorption and implant loosening, affecting the long-term viability of these implants for articular repair. Different studies have highlighted the interest of short stems for preserving bone stock and minimizing shielding, hence providing an alternative to conventional hip prostheses with long stems. Such short stems are especially valuable for younger patients, as they may require additional surgical interventions and replacements in the future, for which the preservation of bone stock is fundamental. Arguably, enhanced results may be achieved by combining the benefits of short stems with the possibilities of personalization, which are now empowered by a wise combination of medical images, computer-aided design and engineering resources and automated manufacturing tools. In this study, an innovative design methodology for custom-made short femoral stems is presented. The design process is enhanced through a novel app employing elliptical adjustment for the quasi-automated CAD modeling of personalized short femoral stems. The proposed methodology is validated by completely developing two personalized short femoral stems, which are evaluated by combining in silico studies (finite element method (FEM) simulations), for quantifying their biomechanical performance, and rapid prototyping, for evaluating implantability.

2021 ◽  
Vol 11 (9) ◽  
pp. 4057
Author(s):  
Leonardo Frizziero ◽  
Gian Maria Santi ◽  
Christian Leon-Cardenas ◽  
Giampiero Donnici ◽  
Alfredo Liverani ◽  
...  

The study of CAD (computer aided design) modeling, design and manufacturing techniques has undergone a rapid growth over the past decades. In medicine, this development mainly concerned the dental and maxillofacial sectors. Significant progress has also been made in orthopedics with pre-operative CAD simulations, printing of bone models and production of patient-specific instruments. However, the traditional procedure that formulates the surgical plan based exclusively on two-dimensional images and interventions performed without the aid of specific instruments for the patient and is currently the most used surgical technique. The production of custom-made tools for the patient, in fact, is often expensive and its use is limited to a few hospitals. The purpose of this study is to show an innovative and cost-effective procedure aimed at prototyping a custom-made surgical guide for address the cubitus varus deformity on a pediatric patient. The cutting guides were obtained through an additive manufacturing process that starts from the 3D digital model of the patient’s bone and allows to design specific models using Creo Parametric. The result is a tool that adheres perfectly to the patient’s bone and guides the surgeon during the osteotomy procedure. The low cost of the methodology described makes it worth noticing by any health institution.


2019 ◽  
Vol 3 (1) ◽  
pp. s-0039-1685505 ◽  
Author(s):  
Yurii Chepurnyi ◽  
Denis Chernogorskyi ◽  
Oksana Petrenko ◽  
Andrii Kopchak

The main purpose of this article is to evaluate the efficacy of patient-specific implants (PSI) in treatment of patients with post-traumatic orbital defects and deformities. Twenty-three patients with post-traumatic orbital defects and deformities, who underwent subsequent reconstructive procedures using PSI, were included in the study. All the patients were examined according to the standard algorithm involving the local status examination, vision assessment, and computed tomography before and after surgery. The study findings show neither postoperative infectious complications nor decreased visual acuity or loss of visual fields. Functional disorders resolved in 65.2% of cases 1 month after the surgical intervention and in 86.96% of patients within a 3-month term. Positive aesthetic outcomes were seen in 95.7% of cases. Reconstruction with computer-aided design/computer-aided manufactured PSI is an effective procedure that allows accurate restoring of the complex orbital anatomy.


2020 ◽  
Vol 6 (1) ◽  
Author(s):  
Ira Goldsmith ◽  
Peter Llewelyn Evans ◽  
Heather Goodrum ◽  
James Warbrick-Smith ◽  
Thomas Bragg

Abstract Background Chest wall resection following wide local excision for bone tumor results in a large defect. Reconstructing this defect is complex and requires skeletal and soft tissue reconstruction. We describe the reconstruction of a large skeletal defect with a three-dimensional (3-D) printed custom-made, anatomically designed, titanium alloy ribs and hemi-sternum implant. Method To design the implant manual bone threshold segmentation was performed to create a 3-D virtual model of the patient’s chest and the tumor from sub-millimeter slice computed tomography (CT) scan data. We estimated the extent of resection needed to ensure tumor-free margins by growing the tumor by two cm all around.. We designed the implant using an anatomical image of the ribs and right hemi-sternum and then fabricated a 3D model of them in titanium metal using TiMG 1 powder bed fusion technology. At surgery the implant was slotted into the defect and sutured to the ribs laterally and hemi-sternum medially. Results Histology confirmed clear all around microscopic margins. Following surgery and at 18 month follow up the patient was asymptomatic with preserved quality of life and described no pain, localized tenderness or breathlessness. There was no displacement or paradoxical movement of the implant. Conclusion Our techniques of CT segmentation, editing, computer aided design of the implant and fabrication using laser printing of a custom-made anatomical titanium alloy chest wall ribs and hemi-sternum for reconstruction is feasible, safe and provides a satisfactory result. Hence, a patient specific 3-D printed titanium chest wall implant is another useful adjunct to the surgical approach for reconstructing large chest wall defects whilst preserving the anatomical shape, structure and function of the thorax.


2019 ◽  
Vol 185 (14) ◽  
pp. 443-443 ◽  
Author(s):  
Federico Longo ◽  
Gianpaolo Savio ◽  
Barbara Contiero ◽  
Roberto Meneghello ◽  
Gianmaria Concheri ◽  
...  

Aims: The purpose of the study was to evaluate the accuracy of a three-dimensional (3D) automated technique (computer-aided design (aCAD)) for the measurement of three canine femoral angles: anatomical lateral distal femoral angle (aLDFA), femoral neck angle (FNA) and femoral torsion angle.Methods:Twenty-eight femurs equally divided intotwo groups (normal and abnormal) were obtained from 14 dogs of different conformations (dolicomorphic and chondrodystrophicCT scans and 3D scanner acquisitions were used to create stereolithographic (STL) files , which were run in a CAD platform. Two blinded observers separately performed the measurements using the STL obtained from CT scans (CT aCAD) and 3D scanner (3D aCAD), which was considered the gold standard method. C orrelation coefficients were used to investigate the strength of the relationship between the two measurements.Results: A ccuracy of the aCAD computation was good, being always above the threshold of R2 of greater than 80 per cent for all three angles assessed in both groups. a LDFA and FNA were the most accurate angles (accuracy >90 per cent).Conclusions: The proposed 3D aCAD protocol can be considered a reliable technique to assess femoral angle measurements in canine femur. The developed algorithm automatically calculates the femoral angles in 3D, thus considering the subjective intrinsic femur morphology. The main benefit relies on a fast user-independent computation, which avoids user-related measurement variability. The accuracy of 3D details may be helpful for patellar luxation and femoral bone deformity correction, as well as for the design of patient- specific, custom-made hip prosthesis implants.


Author(s):  
Johannes P. Pöppe ◽  
Mathias Spendel ◽  
Christoph Schwartz ◽  
Peter A. Winkler ◽  
Jörn Wittig

Abstract Background Manual moulding of cranioplasty implants after craniectomy is feasible, but does not always yield satisfying cosmetic results. In contrast, 3D printing can provide precise templates for intraoperative moulding of polymethylmethacrylate (PMMA) implants in cranioplasty. Here, we present a novel and easily implementable 3D printing workflow to produce patient-specific, sterilisable templates for PMMA implant moulding in cranioplastic neurosurgery. Methods 3D printable templates of patients with large skull defects before and after craniectomy were designed virtually from cranial CT scans. Both templates — a mould to reconstruct the outer skull shape and a ring representing the craniectomy defect margins — were printed on a desktop 3D printer with biocompatible photopolymer resins and sterilised after curing. Implant moulding and implantation were then performed intraoperatively using the templates. Clinical and radiological data were retrospectively analysed. Results Sixteen PMMA implants were performed on 14 consecutive patients within a time span of 10 months. The median defect size was 83.4 cm2 (range 57.8–120.1 cm2). Median age was 51 (range 21–80) years, and median operating time was 82.5 (range 52–152) min. No intraoperative complications occurred; PMMA moulding was uneventful and all implants fitted well into craniectomy defects. Excellent skull reconstruction could be confirmed in all postoperative computed tomography (CT) scans. In three (21.4%) patients with distinct risk factors for postoperative haematoma, revision surgery for epidural haematoma had to be performed. No surgery-related mortality or new and permanent neurologic deficits were recorded. Conclusion Our novel 3D printing-aided moulding workflow for elective cranioplasty with patient-specific PMMA implants proved to be an easily implementable alternative to solely manual implant moulding. The “springform” principle, focusing on reconstruction of the precraniectomy skull shape and perfect closure of the craniectomy defect, was feasible and showed excellent cosmetic results. The proposed method combines the precision and cosmetic advantages of computer-aided design (CAD) implants with the cost-effectiveness of manually moulded PMMA implants.


2014 ◽  
Vol 5 (2) ◽  
pp. 662-671
Author(s):  
Dr. Mohan Babu. G. N. ◽  
Sushravya. G. M.

Most educational models that prescribe teaching and training methods to groom school children into innovators fail to take a deeper view of engineering design methodology. Yet others tend to ignore the importance of human values which must be an integral part of any innovative design process.  In this paper, We would first disaggregate design capabilities into its constituent capabilities, namely, exploring, creating and converging capabilities, which we need to master to produce better products and services, and then show how the cognitive and affective skills proposed by Benjamin Bloom, and Anderson and Krathwohl in their educational models can directly and significantly contribute to these constituent capabilities. With an improved understanding of the eco-system needed for better design solutions, we suggest that the present education systems, especially in developing countries, be critically reviewed and reoriented from the perspective of producing quality innovative designers, regardless of the problem area.  


2020 ◽  
Vol 22 (2) ◽  
pp. 619-636 ◽  
Author(s):  
Zbigniew Tyfa ◽  
Damian Obidowski ◽  
Krzysztof Jóźwik

AbstractThe primary objective of this research can be divided into two separate aspects. The first one was to verify whether own software can be treated as a viable source of data for the Computer Aided Design (CAD) modelling and Computational Fluid Dynamics CFD analysis. The second aspect was to analyze the influence of the Ventricle Assist Device (VAD) outflow cannula positioning on the blood flow distribution in the brain-supplying arteries. Patient-specific model was reconstructed basing on the DICOM image sets obtained with the angiographic Computed Tomography. The reconstruction process was performed in the custom-created software, whereas the outflow cannulas were added in the SolidWorks software. Volumetric meshes were generated in the Ansys Mesher module. The transient boundary conditions enabled simulating several full cardiac cycles. Performed investigations focused mainly on volume flow rate, shear stress and velocity distribution. It was proven that custom-created software enhances the processes of the anatomical objects reconstruction. Developed geometrical files are compatible with CAD and CFD software – they can be easily manipulated and modified. Concerning the numerical simulations, several cases with varied positioning of the VAD outflow cannula were analyzed. Obtained results revealed that the location of the VAD outflow cannula has a slight impact on the blood flow distribution among the brain supplying arteries.


2020 ◽  
Vol 133 (2) ◽  
pp. 521-529 ◽  
Author(s):  
Vivek P. Bodani ◽  
Gerben E. Breimer ◽  
Faizal A. Haji ◽  
Thomas Looi ◽  
James M. Drake

OBJECTIVEEndoscopic resection of third-ventricle colloid cysts is technically challenging due to the limited dexterity and visualization provided by neuroendoscopic instruments. Extensive training and experience are required to master the learning curve. To improve the education of neurosurgical trainees in this procedure, a synthetic surgical simulator was developed and its realism, procedural content, and utility as a training instrument were evaluated.METHODSThe simulator was developed based on the neuroimaging (axial noncontrast CT and T1-weighted gadolinium-enhanced MRI) of an 8-year-old patient with a colloid cyst and hydrocephalus. Image segmentation, computer-aided design, rapid prototyping (3D printing), and silicone molding techniques were used to produce models of the skull, brain, ventricles, and colloid cyst. The cyst was filled with a viscous fluid and secured to the roof of the third ventricle. The choroid plexus and intraventricular veins were also included. Twenty-four neurosurgical trainees performed a simulated colloid cyst resection using a 30° angled endoscope, neuroendoscopic instruments, and image guidance. Using a 19-item feedback survey (5-point Likert scales), participants evaluated the simulator across 5 domains: anatomy, instrument handling, procedural content, perceived realism, and confidence and comfort level.RESULTSParticipants found the simulator’s anatomy to be highly realistic (mean 4.34 ± 0.63 [SD]) and appreciated the use of actual instruments (mean 4.38 ± 0.58). The procedural content was also rated highly (mean 4.28 ± 0.77); however, the perceived realism was rated slightly lower (mean 4.08 ± 0.63). Participants reported greater confidence in their ability to perform an endoscopic colloid cyst resection after using the simulator (mean 4.45 ± 0.68). Twenty-three participants (95.8%) indicated that they would use the simulator for additional training. Recommendations were made to develop complex case scenarios for experienced trainees (normal-sized ventricles, choroid plexus adherent to cyst wall, bleeding scenarios) and incorporate advanced instrumentation such as side-cutting aspiration devices.CONCLUSIONSA patient-specific synthetic surgical simulator for training residents and fellows in endoscopic colloid cyst resection was successfully developed. The simulator’s anatomy, instrument handling, and procedural content were found to be realistic. The simulator may serve as a valuable educational tool to learn the critical steps of endoscopic colloid cyst resection, develop a detailed understanding of intraventricular anatomy, and gain proficiency with bimanual neuroendoscopic techniques.


2016 ◽  
Vol 5 (01) ◽  
pp. 4723 ◽  
Author(s):  
Bhusnure O. G.* ◽  
Gholve V. S. ◽  
Sugave B. K. ◽  
Dongre R. C. ◽  
Gore S. A. ◽  
...  

Many researchers have attempted to use computer-aided design (C.A.D) and computer-aided manufacturing (CAM) to realize a scaffold that provides a three-dimensional (3D) environment for regeneration of tissues and organs. As a result, several 3D printing technologies, including stereolithography, deposition modeling, inkjet-based printing and selective laser sintering have been developed. Because these 3D printing technologies use computers for design and fabrication, and they can fabricate 3D scaffolds as designed; as a consequence, they can be standardized. Growth of target tissues and organs requires the presence of appropriate growth factors, so fabrication of 3Dscaffold systems that release these biomolecules has been explored. A drug delivery system (D.D.S) that administrates a pharmaceutical compound to achieve a therapeutic effect in cells, animals and humans is a key technology that delivers biomolecules without side effects caused by excessive doses. 3D printing technologies and D. D. Ss have been assembled successfully, so new possibilities for improved tissue regeneration have been suggested. If the interaction between cells and scaffold system with biomolecules can be understood and controlled, and if an optimal 3D tissue regenerating environment is realized, 3D printing technologies will become an important aspect of tissue engineering research in the near future. 3D Printing promises to produce complex biomedical devices according to computer design using patient-specific anatomical data. Since its initial use as pre-surgical visualization models and tooling molds, 3D Printing has slowly evolved to create one-of-a-kind devices, implants, scaffolds for tissue engineering, diagnostic platforms, and drug delivery systems. Fuelled by the recent explosion in public interest and access to affordable printers, there is renewed interest to combine stem cells with custom 3D scaffolds for personalized regenerative medicine. Before 3D Printing can be used routinely for the regeneration of complex tissues (e.g. bone, cartilage, muscles, vessels, nerves in the craniomaxillofacial complex), and complex organs with intricate 3D microarchitecture (e.g. liver, lymphoid organs), several technological limitations must be addressed. Until recently, tablet designs had been restricted to the relatively small number of shapes that are easily achievable using traditional manufacturing methods. As 3D printing capabilities develop further, safety and regulatory concerns are addressed and the cost of the technology falls, contract manufacturers and pharmaceutical companies that experiment with these 3D printing innovations are likely to gain a competitive edge. This review compose the basics, types & techniques used, advantages and disadvantages of 3D printing


2021 ◽  
Vol 11 (6) ◽  
pp. 2852
Author(s):  
Maeruan Kebbach ◽  
Christian Schulze ◽  
Christian Meyenburg ◽  
Daniel Kluess ◽  
Mevluet Sungu ◽  
...  

The calculation of range of motion (ROM) is a key factor during preoperative planning of total hip replacements (THR), to reduce the risk of impingement and dislocation of the artificial hip joint. To support the preoperative assessment of THR, a magnetic resonance imaging (MRI)-based computational framework was generated; this enabled the estimation of patient-specific ROM and type of impingement (bone-to-bone, implant-to-bone, and implant-to-implant) postoperatively, using a three-dimensional computer-aided design (CAD) to visualize typical clinical joint movements. Hence, patient-specific CAD models from 19 patients were generated from MRI scans and a conventional total hip system (Bicontact® hip stem and Plasmacup® SC acetabular cup with a ceramic-on-ceramic bearing) was implanted virtually. As a verification of the framework, the ROM was compared between preoperatively planned and the postoperatively reconstructed situations; this was derived based on postoperative radiographs (n = 6 patients) during different clinically relevant movements. The data analysis revealed there was no significant difference between preoperatively planned and postoperatively reconstructed ROM (∆ROM) of maximum flexion (∆ROM = 0°, p = 0.854) and internal rotation (∆ROM = 1.8°, p = 0.917). Contrarily, minor differences were observed for the ROM during maximum external rotation (∆ROM = 9°, p = 0.046). Impingement, of all three types, was in good agreement with the preoperatively planned and postoperatively reconstructed scenarios during all movements. The calculated ROM reached physiological levels during flexion and internal rotation movement; however, it exceeded physiological levels during external rotation. Patients, where implant-to-implant impingement was detected, reached higher ROMs than patients with bone-to-bone impingement. The proposed framework provides the capability to predict postoperative ROM of THRs.