scholarly journals Retinal Optical Quality of Multifocal Refractive and Monofocal Intraocular Lenses

Photonics ◽  
2021 ◽  
Vol 8 (12) ◽  
pp. 559
Author(s):  
Francesco D’Oria ◽  
Ali Nowrouzi ◽  
Jorge L. Alio del Barrio ◽  
Francesco Versaci ◽  
Jorge L. Alio

(1) Background: This study aimed to evaluate and compare the clinical optical image quality following implantation with different premium IOLs by the analysis of the point spread function (PSF) Strehl ratio using a Pyramidal WaveFront-based sensor (PWS) aberrometer at two different pupil sizes. (2) Methods: This study included 96 eyes of 70 patients implanted with: (1) 19 AcrySof SA60AT (control group); (2) 24 LENTIS Mplus LS-313 MF30; (3) 33 LENTIS Mplus LS-313 MF15; and (4) 20 Precizon Presbyopic. Main outcome measures were PSF Strehl ratio, PSF Strehl ratio excluding second-order aberrations (PSFw2), total root-mean-square (RMS), and low- and high-order aberrations’ RMS measured by PWS aberrometer. Results: SA60AT had the highest significant PSFw2 Strehl ratio at both 3- and 4-mm pupil size (0.41 ± 0.11 and 0.28 ± 0.07) followed by LENTIS Mplus 15 (group C, 0.35 ± 0.1 and 0.21 ± 0.06) and a near tie between LENTIS MPLUS 30 (group B, 0.27 ± 0.08 and 0.18 ± 0.06) and Precizon Presbyopic (group D, 0.27 ± 0.07 and 0.17 ± 0.04). MPlus MF15 was found to be significantly better than MPlus MF30 at both 3.00 mm (p < 0.0001) and 4.00 mm (p = 0.002). (4) Conclusions: The PSFw2 represents a new tool to objectively evaluate the far distance retinal image quality of multifocal IOLs, and the far distance clinical image quality parameters measured by PWS aberrometer differed significantly according to the technology of the implanted lens.

2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Jorge L. Alio ◽  
Francesco D’Oria ◽  
Francesca Toto ◽  
Joan Balgos ◽  
Antonio Palazon ◽  
...  

Abstract Background To study and compare the clinical optical image quality following implantation with different premium IOLs by analysing the point spread function (PSF) Strehl ratio using a pyramidal wavefront sensor (PWS)-based aberrometer. Methods This study included 194 eyes implanted with: (a) 19 AcrySof SA60AT (control group); (b) 19 Miniwell; (c) 24 LENTIS Mplus LS-313 MF30; d) 33 LENTIS Mplus LS-313 MF15; (e) 17 AkkoLens Lumina; (f) 31 AT LISA Tri 839MP; (g) 20 Precizon Presbyopic; (h) 20 AcrySof IQ PanOptix; (i) 11 Tecnis Eyhance. Main outcome measures were PSF Strehl ratio, PSF Strehl ratio excluding second-order aberrations (PSFw2), total root mean square (RMS), low-order aberration (LOA) and high-order aberration (HOA) RMS measured by PWS aberrometer. Results AT LISA Tri had the highest PSFw2 Strehl ratio at both 3.0- and 4.0-mm pupil size (0.52 ± 0.14 and 0.31 ± 0.10; P < 0.05), followed by SA60AT (0.41 ± 0.11 and 0.28 ± 0.07) and PanOptix (0.4 ± 0.07 and 0.26 ± 0.04). AT LISA Tri was found to provide a significantly better retinal image quality than PanOptix at both 3.0 mm (P < 0.0001) and 4.0 mm (P = 0.004). Mplus MF15 was found to be significantly better than Mplus MF30 at both 3.0 mm (P < 0.0001) and 4.0 mm (P = 0.002). Total RMS, LOA RMS, HOA RMS, PSF Strehl ratio and PSFw2 varied significantly between the studied groups (P < 0.001). Conclusions Far distance clinical image quality parameters measured by PWS aberrometer differed significantly according to the technology of the implanted lens. AT LISA Tri, SA60AT and PanOptix showed the highest values of far distance retinal image quality, while the lowest PSFw2 Strehl ratios were displayed by Miniwell, Mplus MF30 and Precizon Presbyopic.


2017 ◽  
Vol 28 (1) ◽  
pp. 36-41 ◽  
Author(s):  
Genís Cardona ◽  
Fidel Vega ◽  
Miguel A. Gil ◽  
Consuelo Varón ◽  
José A. Buil ◽  
...  

Purpose: To compare objective image quality at distant, intermediate, and near foci with the corresponding visual acuity (VA) in patients symmetrically implanted with 5 different diffractive multifocal intraocular lenses (IOLs) (ReSTOR SV25T0, Tecnis ZKB00, Tecnis ZLB00, AT LISA 809, and AT LISA Tri 839MP) and a monofocal lens (Tecnis ZA9003) 3 months after cataract intervention. Methods: Objective image quality, measured as the area under the modulation transfer function curve (AMTF), was tested in vitro in an eye model. In addition, corrected distance visual acuity and distance-corrected intermediate and near visual acuities (DCIVA and DCNVA) were assessed in a group of 79 patients, randomly implanted with one of the lenses. Results: Image quality and VA at the distant focus was good for all lens designs, but was similarly compromised at the intermediate focus, where the best DCIVA corresponded to the low add ZKB00. At the near focus, the monofocal lens and the distance dominant SV25T0 had the worst AMTF values, with the ZLB00 presenting the best DCNVA. The relationship between AMTF and VA was found not to be linear, with VA being similarly good for AMTF values over a certain threshold. Conclusions: Visual acuity of pseudophakic patients reflected the optical quality of the specific IOL design within a certain range of measurements, beyond which maximum VA is limited by other ocular, optical, and neuropsychophysical factors.


2018 ◽  
Vol 6 (12) ◽  
pp. 151-158
Author(s):  
Lemonia Darginidou ◽  
Dimitris Goulimaris ◽  
Vassiliki Derri ◽  
Giorgos Kosta

The aim of this study is to investigate whether parents’ perceptions on the emotions and moods of their children are influenced by the children’s participating in traditional dance activities. The sample of the research consisted of 280 parents of adolescents aged 12-13. There were three experimental groups: a) “Control group”, b) “Experimental group 1” and c) “Experimental group 2”. The measurements was carried out with the KIDSCREEN-52 Scale (Ravens-Sieberer et al., 2007). The dimension used was “Mood and emotions”, which includes 7 questions. There were three measurements. The results of the research showed that the parents’ perceptions concerning the factor “mood and emotions” for the quality of life of their children were differentiated among the groups according to the measurements. According to the parents’ perceptions, their adolescent children’s moods and emotions were improved after participating regularly in extracurricular Greek dance activities organized by nonprofit private societies. In conclusion, parents acknowledge that their children’s participating in dance activities in nonprofit societies improved their general mood and developed their positive emotions, which is quite helpful for adolescents to overcome the emotional disturbance of this age.


2017 ◽  
Vol 38 (3) ◽  
pp. 933-941
Author(s):  
Teresa Ferrer-Blasco ◽  
Alberto Domínguez-Vicent ◽  
Santiago García-Lázaro ◽  
María Amparo Diez ◽  
José F. Alfonso ◽  
...  

2017 ◽  
Vol 59 (6) ◽  
pp. 649-656 ◽  
Author(s):  
Teresa Monserrat ◽  
Elena Prieto ◽  
Benigno Barbés ◽  
Luis Pina ◽  
Arlette Elizalde ◽  
...  

Background In 2014, Siemens developed a new software-based scatter correction (Progressive Reconstruction Intelligently Minimizing Exposure [PRIME]), enabling grid-less digital mammography. Purpose To compare doses and image quality between PRIME (grid-less) and standard (with anti-scatter grid) modes. Material and Methods Contrast-to-noise ratio (CNR) was measured for various polymethylmethacrylate (PMMA) thicknesses and dose values provided by the mammograph were recorded. CDMAM phantom images were acquired for various PMMA thicknesses and inverse Image Quality Figure (IQFinv) was calculated. Values of incident entrance surface air kerma (ESAK) and average glandular dose (AGD) were obtained from the DICOM header for a total of 1088 pairs of clinical cases. Two experienced radiologists compared subjectively the image quality of a total of 149 pairs of clinical cases. Results CNR values were higher and doses were lower in PRIME mode for all thicknesses. IQFinv values in PRIME mode were lower for all thicknesses except for 40 mm of PMMA equivalent, in which IQFinv was slightly greater in PRIME mode. A mean reduction of 10% in ESAK and 12% in AGD in PRIME mode with respect to standard mode was obtained. The clinical image quality in PRIME and standard acquisitions resulted to be similar in most of the cases (84% for the first radiologist and 67% for the second one). Conclusion The use of PRIME software reduces, in average, the dose of radiation to the breast without affecting image quality. This reduction is greater for thinner and denser breasts.


2017 ◽  
Vol 2017 ◽  
pp. 1-6 ◽  
Author(s):  
Michael Lasta ◽  
Kata Miháltz ◽  
Illés Kovács ◽  
Pia Veronika Vécsei-Marlovits

Purpose. To compare the effect of spherical aberration on optical quality in eyes with two different aspherical intraocular lenses. Methods. 120 eyes of 60 patients underwent phacoemulsification. In patients’ eyes, an aberration-free IOL (Aspira-aA; Human Optics) or an aberration-correcting aspherical IOL (Tecnis ZCB00; Abott Medical Optics) was randomly implanted. After surgery, contrast sensitivity and wavefront measurements as well as tilt and decentration measurements were performed. Results. Contrast sensitivity was significantly higher in eyes with Aspira lens under mesopic conditions with 12 cycles per degree (CPD) and under photopic conditions with 18 CPD (p=0.02). Wavefront measurements showed a higher total spherical aberration with a minimal pupil size of 4 mm in the Aspira group (0.05 ± 0.03) than in the Tecnis group (0.03 ± 0.02) (p=0.001). Strehl ratio was higher in eyes with Tecnis (0.28 ± 0.17) with a minimal pupil size larger than 5 mm than that with Aspira (0.16 ± 0.14) (p=0.04). In pupils with a minimum diameter of 4 mm spherical aberration had a significant effect on Strehl ratio, but not in pupils with a diameter less than 4 mm. Conclusions. Optical quality was better in eyes with the aberration-correcting Tecnis IOL when pupils were large. In contrast, this could not be shown in eyes with pupils under 4 mm or larger. This trial is registered with Clinicaltrials.gov NCT03224728.


2012 ◽  
Vol 6 (6) ◽  
pp. 234 ◽  
Author(s):  
Ugur Kuyumcuoglu ◽  
Bilal Eryildirim ◽  
Murat Tuncer ◽  
Gokhan Faydaci ◽  
Fatih Tarhan ◽  
...  

Background: We investigated whether the frequency of lower urinary tract symptoms (LUTS) increased in patients in whom double-J stents were applied. We also evaluated several medical therapy protocols to treat symptoms related with ureteral stents.Materials and Methods: A total of 108 patients, in whom unilateral double-j stent was applied during ureteral stone treatment, were included. Before the double-J stent was applied, all patients completed storage components of the “International Prostate Symptom Score” (IPSSs), quality of life components of the IPSS (IPSS-QOL) and “Overactive Bladder Questionnaire” (OABq) forms and scores were calculated. After the procedure, cases were randomized into 5 groups, an antiinflammatory was given to Group 1, spasmolytic to Group 2, anticholinergic to Group 3 and α-blocker to Group 4. No additional drug was given to Group 5 as this control group. During the fourth week of the procedure, IPSSs, IPSS-QOL and OABq forms were again completed and scores were compared with the previous ones.Results: When all the cases were evaluated, the IPSSs, IPSS-QOLand OABq scores of patients in whom the double-J stent was applied were statistically significantly higher the procedure. Compared to the control group, the cases where the double-J stent was applied showed a higher IPSSs, IPSS-QOL and OABq scores and none of the medical therapies could prevent this increase.Interpretation: The frequency of LUTS increased in cases where the ureteral stent was applied and discomfort continued as long as the stent stayed in the body.


2021 ◽  
Author(s):  
Waqar M. Naqvi

Abstract Entrepreneurs usually work for long hours resulting in exhaustion, stress, and burnout. The prevalent symptoms of burnout are reduced levels of physical and mental energy, reduced job efficiency and diminished productivity. Therefore, it is important to improve the health of entrepreneurs. Gamification has a positive relationship with improvements in health and well-being as it influences positive experiences and satisfaction. This trial aims to study how 30-minutes of virtual reality game use via Kinect Azure and Oculus platforms 3-times per week, for 4 weeks, relates to differences in entrepreneur stress, burnout, subjective life quality, and downstream firm performance. We will recruit entrepreneurs over the age of 18 for the gamification analysis. Analysis of previous power using G*Power will determine the sample size. We will divide the participants into 3 groups, wherein Group A will undergo gamification on the Kinect platform, Group B will undergo the Oculus Quest intervention, and Group C will be the control group. We will conduct the study at two sites, one at the HuMen research. The outcome measures include a five-point Likert scale for measuring entrepreneurial stress, burnout-measuring scale (BMS) for burnout, five-point Likert scale for performance and SF-12 for Quality of life. Since current strains pave ways to future accomplishment, entrepreneurs' eudemonic well-being might particularly relate to forward-looking challenge stressors and burnouts. The results will provide an insight into how gamification could help entrepreneurs to deal with work stress and maintain high well-being.


Author(s):  
Jorge L Alio ◽  
Pablo Sanz-Díez

ABSTRACT Purpose To discuss and summarize the indications, contraindications and results in refractive surgery for keratoconus. Summary Keratoconus is an ectatic corneal disease characterized by a progressive corneal thinning and irregular astigmatism that negatively impact in the visual function and the optical quality of the patients. The refractive surgery in keratoconus has been discussed by several authors. The two primary lines of action are phakic lens implantation and corneal tissue ablation using photorefractive keratectomy. The use of phakic intraocular lenses (IOLs) to correct myopia and compound myopic astigmatism associated with keratoconus is gaining popularity. Recent findings The use of phakic IOLs to correct myopia and compound myopic astigmatism associated with keratoconus is gaining popularity. According to a recent study by our group the safety of this procedure in visual terms is high (post-CDVA/ pre-CDVA = 1.19 ± 0.29). It is also an effective operation (post-UDVA/pre-CDVA = 0.90 ± 0.26). How to cite this article Alio JL, Sanz-Díez P. Phakic Intraocular Lenses in Keratoconus. Int J Kerat Ect Cor Dis 2015;4(3):103-106.


Author(s):  
Yang-Ting Hsu ◽  
Jo-Chi Jao

Radiologic technologists face various types of patients during multi-detector computed tomography (CT) examinations. In emergency departments, it is common to have patients who cannot follow instructions for the examinations. The asymmetric axial view of the head CT might affect the correctness of the clinician’s diagnosis. This study aimed to assess the impact of head positioning on the image quality of head CT using two phantoms. All scans were performed on a 16-slice CT scanner. In the control group, the tilted angle of the phantoms was 0[Formula: see text], and no multiplanar reconstruction (MPR) was performed. In the experimental groups, the tilted angles of the phantoms were 5[Formula: see text], 10[Formula: see text] and 15[Formula: see text], respectively, and MPR was performed afterwards. The results showed that if the head was tilted during the head CT examinations, image asymmetry and artifacts appeared without MPR. After MPR, one phantom showed that there were significant differences and the other phantom showed no significant differences quantitatively in image symmetry and artifacts between experimental groups and the control group, while both phantoms showed no significant differences qualitatively in image symmetry and artifacts between experimental groups and the control group. Although MPR can correct the image asymmetry and artifacts caused by tilted head positioning to some extent, it consumes time. Therefore, technologists should position the head as exactly as possible when performing head CT examinations.