scholarly journals Effect of Different Bond Parameters on the Mechanical Properties of FRP and Concrete Interface

Polymers ◽  
2020 ◽  
Vol 12 (11) ◽  
pp. 2466
Author(s):  
Comfort Mensah ◽  
Zhenqing Wang ◽  
Alex Osei Bonsu ◽  
Wenyan Liang

This paper presents double shear tests performed to investigate factors influencing the bond behavior between basalt fiber-reinforced polymer (BFRP), glass fiber-reinforced polymer (GFRP) laminate, and concrete blocks. In detail, thirty-six twin concrete blocks strengthened with the aforementioned FRP types were tested to evaluate the influence of FRP length, width, and thickness, and their bonding behavior. The 2D-DIC (digital image correlation) technique and several strain gauges bonded along the laminate were used to measure the strain distributions of the FRP-to-concrete interface. The failure mode, ultimate load, load–slip, strain distribution, and bond–slip relationships between the laminates and concrete were analyzed. Furthermore, bond–slip curves were compared with some other existing literature models. The results from the experiment showed that the ultimate load, peak bond stress, and slip increased with the increase in the BFRP and GFRP laminates length, width, and thickness. The values of peak shear stress and the corresponding maximum shear slip were significantly different because of the above-mentioned factors’ influence on them. The bond interface that contributes to the bearing of the shear load may grow to an extent and later shift from the loaded end when debonding progresses. Finally, the fractured surfaces of the failed FRP laminates were examined using scanning electron microscope (SEM), revealing that FRP rupture, debonding in concrete, and debonding in an adhesive–concrete interface were the main failure types.

2019 ◽  
Vol 54 (1) ◽  
pp. 13-29 ◽  
Author(s):  
Yu-Yang Pang ◽  
Gang Wu ◽  
Hai-Tao Wang ◽  
Zhi-Long Su ◽  
Xiao-Yuan He

The bond–slip degradation relationship between carbon fiber-reinforced polymer and steel in a freeze–thaw environment is crucial to evaluate the long-term service performance of steel structures strengthened with carbon fiber-reinforced polymer plates. However, limited studies on the durability and long-term performance of the carbon fiber-reinforced polymer-steel-bonded interface are the major obstacle for the application of carbon fiber-reinforced polymer plates in strengthening steel structures. This paper reports an experimental study to investigate the effects of the carbon fiber-reinforced polymer bond length and the freeze–thaw cycles on the bond behavior of the carbon fiber-reinforced polymer-steel-bonded interface. The three-dimensional digital image correlation technique is applied to obtain displacements and strains on the surface of the single-shear specimen. The experimental results present herein include the failure mode, the ultimate load, the carbon fiber-reinforced polymer strain distribution, the displacement distribution, and the bond–slip relationship. The results show that the ultimate load increases with increasing bond length until a certain bond length value is reached, after which the ultimate load remained approximately constant, and the ultimate loads of carbon fiber-reinforced polymer-steel interface decrease gradually under freeze–thaw cycles. The bond–slip parameters degradation models are proposed, and the bond–slip degradation relationship under the freeze–thaw cycles is established. Finally, the bond–slip degradation relationship is confirmed through comparisons with the experimental results.


2008 ◽  
Vol 35 (3) ◽  
pp. 312-320 ◽  
Author(s):  
A. Zaidi ◽  
R. Masmoudi

The difference between the transverse coefficients of thermal expansion of fiber reinforced polymer (FRP) bars and concrete generates radial pressure at the FRP bar – concrete interface, which induces tensile stresses within the concrete under temperature increase and, eventually, failure of the concrete cover if the confining action of concrete is insufficient. This paper presents the results of an experimental study to investigate the thermal effect on the behaviour of FRP bars and concrete cover, using concrete slab specimens reinforced with glass FRP bars and subjected to thermal loading from –30 to +80 °C. The experimental results show that failure of concrete cover was produced at temperatures varying between +50 and +60 °C for slabs having a ratio of concrete cover thickness to FRP bar diameter (c/db) less than or equal to 1.4. A ratio of c/db greater than or equal to 1.6 seems to be sufficient to avoid splitting failure of concrete cover for concrete slabs subjected to high temperatures up to +80 °C. Also, the first cracks appear in concrete at the FRP bar – concrete interface at temperatures around +40 °C. Comparison between experimental and analytical results in terms of thermal loads and thermal strains is presented.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Mervin Ealiyas Mathews ◽  
Anand N ◽  
Diana Andrushia A ◽  
Tattukolla Kiran ◽  
Khalifa Al-Jabri

PurposeBuilding elements that are damaged by fire are often strengthened by fiber wrapping techniques. Self-compacting concrete (SCC) is an advanced building material that is widely used in construction due to its ability to flow and pass through congested reinforcement and fill the required areas easily without compaction. The aim of the research work is to examine the flexural behavior of SCC subjected to elevated temperature. This research work examines the effect of natural air cooling (AC) and water cooling (WC) on flexural behavior of M20, M30, M40 and M50 grade fire-affected retro-fitted SCC. The results of the investigation will enable the designers to choose the appropriate repair technique for improving the service life of structures.Design/methodology/approachIn this study, an attempt has been made to evaluate the flexural behavior of fire exposed reinforced SCC beams retrofitted with laminates of carbon fiber reinforced polymer (CFRP), basalt fiber reinforced polymer (BFRP) and glass fiber reinforced polymer (GFRP). Beam specimens were cast with M20, M30, M40 and M50 grades of SCC and heated to 925ºC using an electrical furnace for 60 min duration following ISO 834 standard fire curve. The heated SCC beams were cooled by either natural air or water spraying.FindingsThe reduction in the ultimate load carrying capacity of heated beams was about 42% and 55% for M50 grade specimens that were cooled by air and water, respectively, in comparison with the reference specimens. The increase in the ultimate load was 54%, 38% and 27% for the specimens retrofitted with CFRP, BFRP and GFRP, respectively, compared with the fire-affected specimens cooled by natural air. Water-cooled specimens had shown higher level of damage than the air-cooled specimens. The specimens wrapped with carbon fiber could able to improve the flexural strength than basalt and glass fiber wrapping.Originality/valueSCC, being a high performance concrete, is essential to evaluate the performance under fire conditions. This research work provides the flexural behavior and physical characteristics of SCC subjected to elevated temperature as per ISO rate of heating. In addition attempt has been made to enhance the flexural strength of fire-exposed SCC with wrapping using different fibers. The experimental data will enable the engineers to choose the appropriate material for retrofitting.


2016 ◽  
Vol 707 ◽  
pp. 51-59 ◽  
Author(s):  
Osama Ahmed Mohamed ◽  
Rania Khattab

The behaviour of reinforced concrete beam strengthened with Carbon Fiber Reinforced Polymer (CFRP) and Glass fiber reinforced polymer GFRP laminates was investigated using finite element models and the results are presented in this paper. The numerical investigation assessed the effect of the configuration of FRP strengthening laminates on the behaviour of concrete beams. The load-deflection behaviour, and ultimate load of strengthened beam were compared to those of un-strengthened concrete beams. It was shown that using U-shaped FRP sheets increased the ultimate load. The stiffness of the strengthed beam also increased after first yielding of steel reinforcing bars. At was also observed that strengthening beams with FRP laminates to one-fourth of the beam span, modifies the failure of the beam from shear-controlled near the end of the unstrengthened beam, to flexure-controlled near mid-span. CFRP produced better results compared GFRP in terms of the ability to enhance the behavior of strengthenened reinforced concrete beams.


2020 ◽  
Vol 2020 ◽  
pp. 1-10
Author(s):  
Bo Wen ◽  
Chunfeng Wan ◽  
Lin Liu ◽  
Da Fang ◽  
Caiqian Yang

Fatigue behavior is an important factor for mechanical analysis of concrete members reinforced by basalt fiber reinforced polymer (BFRP) grid and polymer cement mortar (PCM) and plays a critical role in ensuring the safety of reinforced concrete bridges and other structures. In this study, on the basis of the static loading test results of concrete specimens reinforced by BFRP grid and PCM, a series of fatigue tests with different loading levels were conducted on interfaces between BFRP grid and concrete to investigate the fatigue behavior of BFRP grid-concrete interfaces. The test results indicate that with high loading level, the fatigue failure mode of interface is interfacial peeling failure while it transforms to the fatigue fracture of the BFRP grid under low loading level. The fatigue life (S-N) curves of BFRP grid-concrete interface are obtained and fitted in stages according to different failure modes, and the critical point of the two failure modes is pointed out. The relative slip evolution of interface during fatigue is further revealed in different stages with two failure modes, and the law of interface strain is studied with the increase of fatigue times. The relation of effective bonding length of interface and fatigue times is also described.


2020 ◽  
Vol 23 (15) ◽  
pp. 3323-3334
Author(s):  
Buntheng Chhorn ◽  
WooYoung Jung

The bonding performance of basalt fiber-reinforced polymer and concrete substrate has a significant effect on the reliability of externally strengthened existing concrete structure, due to being the most vulnerable element to failure in this fiber-reinforced polymer–concrete strengthening system. Its failure can result in the failure of the whole structure. Although many previous researchers have been interested in the tensile bonding strength of carbon fiber-reinforced polymer and glass fiber-reinforced polymer–concrete interface, that of basalt fiber-reinforced polymer–concrete interface has been very limited. Thus, the objective of this study is to experimentally assess the tensile bonding strength of the basalt fiber-reinforced polymer–concrete interface. The effects of high temperature, freezing–thawing cycles, type of resin, and concrete crack widths on the tensile bonding strength are also investigated. The pull-off experiment is conducted according to ASTM D7522/D7522M-15. A total of 205 core specimens of 50 mm diameter and 10 mm depth were taken from 41 concrete beams. The experimental results illustrate that both freezing–thawing and high-temperature condition have a substantial effect on the bonding strength of the basalt fiber-reinforced polymer–concrete interface. Bonding strength was decreased within the range of about 9%–30% when the number of freezing–thawing cycles increases from 100 to 300; likewise, it was decreased up to 30% when the exposure temperature rises to 200°C. Also, the specimens which were repaired to close their cracks by epoxy resin had no significant effect on the bonding strength of basalt fiber-reinforced polymer–concrete interface, when the specimens had crack width of less than 1.5 mm.


2020 ◽  
Vol 9 (11) ◽  
pp. e2939119838
Author(s):  
Jaqueline Damiany Portela ◽  
Rômulo Marçal Gandia ◽  
Bárbara Lemes Outeiro Araújo ◽  
Rodrigo Allan Pereira ◽  
Francisco Carlos Gomes

The Glass Fiber Reinforced Polymer (GFRP) waste despite having excellent physical and mechanical properties is still largely unexplored besides presenting large volume of waste with very low degradability. The use of concrete block presents high resistance to compression, low price high masonry coating ratio by material weight, however high thermal conductivity. Therefore, the study aimed to produce and investigate the effect of adding GRFP residues to concrete blocks due to physical, mechanical and thermal properties. The compositions were made by replacing the fine gravel between 0 to 10% in mass by the GFRP residue. They were evaluated from physical, mechanical and thermal tests. The results showed that the use of GFRP residue did not interfere in water absorption and compressive strength, despite the significant increase in mechanical energy absorption of the material. Thermal conductivity reduced by 46% and the concrete blocks were 7% lighter. In addition to providing a destination for a considerable quantity of the waste, the commercial value of the final product is higher due to using a residue with low degradability and high energy power due to burning during recycling.