scholarly journals Numerical Investigation of an Open-Design Vortex Pump with Different Blade Wrap Angles of Impeller

Processes ◽  
2020 ◽  
Vol 8 (12) ◽  
pp. 1601
Author(s):  
Xiongfa Gao ◽  
Ting Zhao ◽  
Weidong Shi ◽  
Desheng Zhang ◽  
Ya Shi ◽  
...  

The blade wrap angle of impeller is an important structural parameter in the hydraulic design of open-design vortex pump. In this paper, taking a vortex pump with a cylindrical blade structure as the research object, two kinds of different blade wrap angle of vortex pump impellers are designed. The experiment and numerical simulation research is carried out, and the results of external characteristics and internal flow field are obtained under different flow rate. The results show that when ensuring that other main structural parameters remain unchanged, the efficiency and head of open-design vortex pump increase with the blade wrap angle decreases. In the case of blade wrap angle increasing, the length of rotating reflux back from lateral cavity to inlet is longer. For the same type of vortex pump, the length of rotating reflux to inlet decreases with the increase of flow rate. At the inlet area of impeller front face, there is an area where liquid flows back to the lateral cavity. The volute section shows that after passing through the impeller and lateral cavity, the liquid is discharged to the pump outlet with strong spiral strength. It is found that the blade wrap angle decreases and the shaft power increases, while the pump efficiency increases. The impeller blade wrap angle of vortex pump can be considered to select a smaller value.

2021 ◽  
Vol 11 (19) ◽  
pp. 9052
Author(s):  
Linwei Tan ◽  
Yongfei Yang ◽  
Weidong Shi ◽  
Cheng Chen ◽  
Zhanshan Xie

To investigate the effect of blade wrap angle on the hydrodynamic radial force of a single blade centrifugal pump, numerical simulation is conducted on the pumps with different blade wrap angles. The effect of the wrap angle on the external characteristics and the radial force of a single blade centrifugal pump was analyzed according to the simulation result. It is found that, with the increase of the blade wrap angle, the head and efficiency of the single blade centrifugal pump are improved, the H-Q curve becomes steeper, and the efficiency also increased gradually, while the high-efficiency area is narrowed. The blade wrap angle has a great effect on the radial force of the single blade centrifugal pump. When the blade wrap angle is less than 360°, the horizontal component of the radial force is negative and the value is reduced with the increase of the wrap angle of the blade. When the wrap angle is larger than 360°, the horizontal component of the radial force is positive and the value increases with the increase of the wrap angle. Under part-loading conditions, the radial force of the single blade pump is significantly reduced with the increase of the blade wrap angle. When the wrap angle is smaller than 360°, the radial force decreases with the flow rate increase. In the condition that the wrap angle is larger than 360°, the radial force increases with the flow rate increase.


2012 ◽  
Vol 134 (6) ◽  
Author(s):  
Sun-Sheng Yang ◽  
Fan-Yu Kong ◽  
Hao Chen ◽  
Xiang-Hui Su

A pump is not ideally designed to operate as a turbine. To improve the efficiency of a pump as turbine (PAT), the redesign of the PAT, according to the flow of the turbine, is required. The blade wrap angle is one of the main geometric parameters in impeller design. Therefore, an investigation into the blade wrap angle to the PAT’s influence can be useful. In order to understand blade wrap angle to the influence of the PAT, this paper numerically investigated three different specific speeds of PATs with different blade wrap angles. The validity of numerical simulation was first confirmed through a comparison between numerical and experimental results. The performance change of the PATs with the blade wrap angle was acquired. A detailed hydraulic loss distribution and a theoretical analysis were performed to investigate the reasons for performance changes caused by the blade wrap angle. The results show that there is an optimal blade wrap angle for a PAT to achieve the highest efficiency and the optimal blade wrap angle decreases with an increasing specific speed. A performance analysis shows the PAT’s flow versus pressure head (Q-H) and flow versus generated shaft power (Q-P) curves are lowered with the decrease of the blade wrap angle. The hydraulic loss distribution and theoretical analysis illustrate that it is the decrease of hydraulic loss within the impeller, together with the decrease of the theoretical head, that results in the performance decrease. The decrease of hydraulic loss within the impeller is attributed to the shortened impeller blade passage and the reduced velocity gradient within the impeller flow channel. With the decrease of the blade wrap angle, the slip factor of the PAT’s impeller is decreased; therefore, its theoretical head is also decreased.


Processes ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. 650
Author(s):  
Guangtai Shi ◽  
Dandan Yan ◽  
Xiaobing Liu ◽  
Yexiang Xiao ◽  
Zekui Shu

The gas volume fraction (GVF) often changes from time to time in a multiphase pump, causing the power capability of the pump to be increasingly affected. In the purpose of revealing the pressure load characteristics of the multiphase pump impeller blade with the gas-liquid two-phase case, firstly, a numerical simulation which uses the SST k-ω turbulence model is verified with an experiment. Then, the computational fluid dynamics (CFD) software is employed to investigate the variation characteristics of static pressure and pressure load of the multiphase pump impeller blade under the diverse inlet gas volume fractions (IGVFs) and flow rates. The results show that the effect of IGVF on the head and hydraulic efficiency at a small flow rate is obviously less than that at design and large flow rates. The static pressure on the blade pressure side (PS) is scarcely affected by the IGVF. However, the IGVF has an evident effect on the static pressure on the impeller blade suction side (SS). Moreover, the pump power capability is descended by degrees as the IGVF increases, and it is also descended with the increase of the flow rate at the impeller inlet. Simultaneously, under the same IGVF, with the increase of the flow rate, the peak value of the pressure load begins to gradually move toward the outlet and its value from hub to shroud is increased. The research results have important theoretical significance for improving the power capability of the multiphase pump impeller.


Author(s):  
Ning Zhang ◽  
Bo Gao ◽  
Chao Li ◽  
Dan Ni ◽  
Guoping Li

Effects of the staggered blades on unsteady pressure pulsations of a centrifugal pump with a specific speed ns=147 are investigated by the numerical simulation method. The obtained results are compared with the original blades. To clarify the resulting effects, eight monitoring points are used to extract pressure signals at three typical working conditions, and component at the blade passing frequency fBPF is emphasized. Results show that the pump efficiency and head will be reduced by the staggered blades, and at the nominal flow rate, the reduction is about 1.5% from comparison with the original blades. For all the eight points, the staggered blades contribute to the reduction of pressure amplitudes at fBPF when the pump works at three flow rates. The averaged reduction is 15.5% at the nominal flow rate. However, the negative effect on the second harmonic of fBPF will be caused by the staggered blades, and the corresponding pressure amplitude will increase at 2fBPF. It means that the pressure pulsation energy will be redistributed among the discrete components in pressure spectrum by the staggered blades. From the TKE distribution, it is found that the TKE values on the blade pressure side will be significantly affected by the staggered blades.


2017 ◽  
Vol 42 (29) ◽  
pp. 18709-18717 ◽  
Author(s):  
Yuxing Bai ◽  
Fanyu Kong ◽  
Sunsheng Yang ◽  
Kai Chen ◽  
Tao Dai

2019 ◽  
Vol 2019 ◽  
pp. 1-15 ◽  
Author(s):  
Lingfeng Tang ◽  
Mingwei Liu ◽  
Feihong Ma

In order to obtain the optimum structure of the lining pump under the condition of fluid thermosetting coupling, according to the given design parameters, the structural parameters of the pump were calculated, the three-dimensional geometric model was established, and the flow field analysis was carried out by CFD; the inlet angle βb1, outlet angle βb2, wrap angle φ, inlet diameter D1, and outlet diameter D2 of the impeller were selected as the five factors to design orthogonal experiment, and the results were analyzed by range analysis; then, the efficiency and cavitation allowance were obtained as combined parameters under the evaluation index. The displacement deformation and stress distribution under the condition of the coupling field were obtained by the fluid-solid coupling analysis, and the orthogonal experimental table of the impeller structure of the lining plastic pump was established, and then the orthogonal experimental results are analyzed to obtain the influence of each structural parameter under the condition of each evaluation index and the optimum combination parameters. The influence situation and the best combination parameters under the condition of evaluation index, taking the minimum displacement deformation and minimum stress of impeller as the reference index, and the optimum combination parameters under the condition of minimum displacement and stress were as follows: the inlet diameter D1 was 76 mm, the outlet diameter D2 was 252 mm, the inlet angle was 26°, the outlet angle was 24°, and the wrap angle was 115°. Finally, the 3D printing technology was used to print out the physical model to the hydraulic performance experiment verification.


2018 ◽  
Vol 45 (2) ◽  
pp. 231-251
Author(s):  
Nazish Shahid

Variation in the dynamics of a steady-state blood flow through a stenosed tapered artery has been investigated corresponding to changes in thixotropic parameter ? over the range [0,1]. To probe the role of parameter ? and differentiate the current model from other known non-Newtonian models, expressions of axial velocity, shear stress, wall shear stress and flow rate have been calculated depending upon this parameter and pressure gradient. Also, pressure gradient has been deduced uniquely with the help of the continuity equation. Our choice of calculating pressure gradient has led to obtaining shear stress such that its dependence on the structural parameter of our model, unlike most available results, motivates for further investigation. The simultaneous effects of varying yield stress and parameter ? on axial velocity, flow resistance and flow rate have been studied such that the differences between the Herschel?Bulkley fluid model and our current model can be pointed out. To validate the suitability of our model and some results in history, we have also obtained limiting results for particular values of ?.


Author(s):  
Guangtai Shi ◽  
Zongku Liu ◽  
Yexiang Xiao ◽  
Helin Li ◽  
Xiaobing Liu

To investigate the effect of tip clearance on the velocity distribution in a multiphase pump, the internal flow and velocity distribution characteristics in pump under different tip clearances are studied using experimental and numerical methods. Simulations based on the Reynolds-Averaged Navier-Stokes equations (RANS) and the standard k-ε turbulence model are carried out using ANSYS CFX. Under conditions of inlet gas void fraction (IGVF) is 5% at the flow rate of 0.6Q, 0.7Q and 0.8Q (Q is the design flow rate), the accuracy of the numerical method is verified by comparing with the experimental data using high-speed photography. Results show that the leakage flow interacts with the main flow and evolves into the tip leakage vortex (TLV). Due to the TLV, the pressure, velocity, turbulent kinetic energy (TKE), vorticity and streamlines on the S2 stream surface in the impeller and diffuser are changed greatly under different tip clearances. The velocities at the impeller outlet and diffuser inlet along the radial direction are also changed. The axial velocity distribution is similar to the meridional velocity distribution at the impeller blade outlet. While the relative velocity and absolute velocity distribution show the opposite trends. In addition, the vorticity is larger near the tip separated vortex and the hydraulic loss in pump is also increased due to the TLV.


2012 ◽  
Vol 12 (03) ◽  
pp. 1250045 ◽  
Author(s):  
JIAXING QI ◽  
YANHONG ZHOU ◽  
DONGFANG WANG ◽  
LIANG ZHONG

Computational fluid dynamics (CFD) simulations of the flow in an axial blood pump with different blade heights (BH150, BH200 and BH250) were performed in the present study. The flow in the pump was assumed as steady and turbulent, and blood was treated as incompressible and Newtonian fluid. The flow rate increased with the rise in blade heights. At the impeller rotating speed of 20,000 rpm and a pressure of 100 mm Hg, the pump produces a flow rate up to 5 L/min in BH200 and BH250 models. The reverse flow and vortices have been identified in the BH150 and BH200 models in the outlet regions, but not for BH250 model. The high shear stress of the flow in the pump mainly occurred at the blade tips. The BH200 model achieved an expected flow rate up to 5 L/min with 90% of the shear stresses less than 500 Pa and the exposure time less than 22 ms, which has the acceptable shear stress level in the literature.


Sign in / Sign up

Export Citation Format

Share Document