Characterization of Novel Solid Dispersions of Moringa oleifera Leaf Powder Using Thermo-Analytical Techniques

Processes ◽  
2021 ◽  
Vol 9 (12) ◽  
pp. 2230
Author(s):  
Nontsikelelo Noxolo Tafu ◽  
Victoria A. Jideani

Moringa oleifera leaf powder (MOLP) has been identified as the most important functional ingredient owing to its rich nutritional profile and healthy effects. The solubility and functional properties of this ingredient can be enhanced through solid dispersion technology. This study aimed to investigate the effects of polyethylene glycols (PEGs) 4000 and 6000 as hydrophilic carriers and solid dispersion techniques (freeze-drying, melting, solvent evaporation, and microwave irradiation) on the crystallinity and thermal stability of solid-dispersed Moringa oleifera leaf powders (SDMOLPs). SDMOLPs were dully characterized using powder X-ray diffraction (PXRD), differential scanning calorimetry (DSC), thermo-gravimetric analysis (TGA), and Fourier transform infrared spectroscopy (FTIR). The PXRD results revealed that the solid dispersions were partially amorphous with strong diffraction peaks at 2θ values of 19° and 23°. The calorimetric and thermogravimetric curves showed that PEGs conferred greater stability on the dispersions. The FTIR studyrevealed the existence of strong intermolecular hydrogen bond interactions between MOLP and PEG functional groups. MOLP solid dispersions may be useful in functional foods and beverages and nutraceutical formulations.

Author(s):  
M. Mohan Varma ◽  
Razia Begum S K

Carbamazepine is a water-insoluble antiepileptic drug. Being a BCS class-II drug, its absorption is dissolution rate limited. Solid dispersions were prepared to enhance the dissolution rate of the drug. Crospovidone and croscarmellose sodium were used as the hydrophilic carriers. Solid dispersions showed a remarkable enhancement in the dissolution rate of the drug. In the present research work, the solid dispersions were formulated in to fast dissolving tablets. The prepared tablets were evaluated for hardness, friability, drug content, disintegration time and the in vitro dissolution rate. The solid dispersions were characterized by Fourier Transform Infrared Spectroscopy (FTIR), differential scanning calorimetry (DSC) and thermo-gravimetric analysis (TGA). The DSC study revealed a marked reduction in the crystallinity of the drug. The faster dissolution rate of the solid dispersion is attributed to a marked reduction in the crystallinity of the drug. The FTIR and DSC studies demonstrated the absence of drug-polymer interaction. The formulated tablet (F2) achieved a 7 fold faster dissolution rate compared to the marketed tablet.


Molecules ◽  
2020 ◽  
Vol 25 (9) ◽  
pp. 2158
Author(s):  
Nanci Vanesa Ehman ◽  
Diana Ita-Nagy ◽  
Fernando Esteban Felissia ◽  
María Evangelina Vallejos ◽  
Isabel Quispe ◽  
...  

Bio-polyethylene (BioPE, derived from sugarcane), sugarcane bagasse pulp, and two compatibilizers (fossil and bio-based), were used to manufacture biocomposite filaments for 3D printing. Biocomposite filaments were manufactured and characterized in detail, including measurement of water absorption, mechanical properties, thermal stability and decomposition temperature (thermo-gravimetric analysis (TGA)). Differential scanning calorimetry (DSC) was performed to measure the glass transition temperature (Tg). Scanning electron microscopy (SEM) was applied to assess the fracture area of the filaments after mechanical testing. Increases of up to 10% in water absorption were measured for the samples with 40 wt% fibers and the fossil compatibilizer. The mechanical properties were improved by increasing the fraction of bagasse fibers from 0% to 20% and 40%. The suitability of the biocomposite filaments was tested for 3D printing, and some shapes were printed as demonstrators. Importantly, in a cradle-to-gate life cycle analysis of the biocomposites, we demonstrated that replacing fossil compatibilizer with a bio-based compatibilizer contributes to a reduction in CO2-eq emissions, and an increase in CO2 capture, achieving a CO2-eq storage of 2.12 kg CO2 eq/kg for the biocomposite containing 40% bagasse fibers and 6% bio-based compatibilizer.


Coatings ◽  
2019 ◽  
Vol 9 (6) ◽  
pp. 348 ◽  
Author(s):  
Baolei Liu ◽  
Mingqian Wang ◽  
Ying Liang ◽  
Zhicheng Zhang ◽  
Guohong Ren ◽  
...  

This work launches the first-ever report on the fabrication of waterborne epoxy-graphene oxide (GO) coatings (WEGC) using a block polymer as a dispersant of GO, wherein the block polymer was synthesized via reversible addition-fragmentation chain transfer (RAFT) polymerization of acrylic acid and oligo(ethylene glycol) methyl ether methacrylate A number of analytical techniques, such as Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), X-ray diffraction (XRD), thermo gravimetric analysis (TGA), and salt spray tests, were utilized to explore the morphology and performance of the WEGC. It was confirmed that POEGMA950-b-PAA attached to the GO nanosheets, increasing the integral space of the sheets. Modified GO (MGO) layers were well-dispersed in the epoxy matrix through the formation of a GO-dispersant-epoxy ternary molecular structure. Furthermore, the presence of MGO substantially influenced the thermal properties, mechanical properties, and anticorrosion performance of the WEGC. TGA, salt spray tests, and pull-off testsshowed that 0.5 wt.% MGO content achieved the greatest improvement in the evaluated properties.


2011 ◽  
Vol 31 (2-3) ◽  
Author(s):  
Sakvai Mohammed Safiullah ◽  
Deivasigamani Thirumoolan ◽  
Kottur Anver Basha ◽  
K. Mani Govindaraju ◽  
Dhanraj Gopi ◽  
...  

Abstract The synthesis of copolymers from different feed ratios of N-(p-bromophenyl)-2- methacrylamide (PBPMA) and glycidyl methacrylate (GMA) was achieved by using free radical solution polymerization technique and characterized using FT-IR, 1H and 13C NMR spectroscopy. The thermal stability of the synthesized copolymers was studied using thermo-gravimetric analysis (TGA) and differential scanning calorimetry (DSC). The molecular weight of the copolymer is determined by gel permeation chromatography (GPC). The corrosion performances of low nickel stainless steel specimens dip coated with different composition of copolymers were investigated in 0.5 M H2SO4 using potentiodynamic polarization and electrochemical impedance spectroscopic (EIS) techniques. The polarization and impedance measurements showed different corrosion protection efficiency with change in composition of the copolymers. It was found that the corrosion protection properties are owing to the barrier effect of the polymer layer covered on the low nickel stainless steel surfaces. However, it is observed that the mole ratio of PBPMA and GMA plays a major role in the protective nature of the copolymer.


2019 ◽  
Vol 41 (3) ◽  
pp. 388-388
Author(s):  
Khalid Saeed Khalid Saeed ◽  
Tariq Shah and Ahmad Hassan Tariq Shah and Ahmad Hassan

Effect of graphene nanoplates (GNPs) on the properties of Nylon 6,6 (Nyl 6,6) is investigated in present study. The morphological studies presented that the GNPs were dispersed inside the Nyl 6,6 matrix. The thermo gravimetric analysis (TGA) illustrated that the thermal degradation of nanocomposites samples were started at the range of 350-393 oC, which was appreciably higher than neat Nyl 6,6 (360 oC). The differential scanning calorimetry (DSC) analyses revealed that the crystallization temperature (Tc) of GNPs/Nyl 6,6 increased as increased the addition of GNPs, which might be due to the nucleation effect of GNPs. The mechanical properties of Nyl 6,6 was enhanced by incorporation of GNPs upto the addition of an optimal quantity of filler (5%wt GNPs) into the polymer matrix. The stress yield and Young’s modulus of 5%wt GNPs/Nyl 6,6 was 96.79 and 1.54, N/nm2, respectively. Both Nyl 6,6 and nanocomposites samples were also used for the adsorption of Neutral red chloride (NRC) dye, which significantly remove the dye from the aqueous solution. The neat nylon 6,6 and GNPs (5 and 10 wt%)/Nyl 6,6 adsorbed about 88.49, 93.15, and 93.60% within 2 h, respectively.


2021 ◽  
pp. 1-8
Author(s):  
Ching-Cheng Huang

BACKGROUND: The biologic scaffolds derived from decellularized tissues and organs have been successfully developed in a variety of preclinical and/or clinical studies. OBJECTIVE: The new decellularized liver-regenerative 3D printing biomaterials were designed and prepared for cell-based liver therapies. METHODS: An extraction process was employed to remove the tissue and cellular molecules from porcine liver via pretreatment of supercritical fluid of carbon dioxide (ScCO2). Varying porosities of the decellularized liver tissues were created using papain-containing reagent treatments after ScCO2. RESULTS: The resulting liver-regenerative 3D printing biomaterials of decellularized liver collagen scaffolds were characterized by Fourier transform infrared spectroscopy, thermo-gravimetric analysis, differential scanning calorimetry and scanning electron microscopy. CONCLUSIONS: The decellularized liver collagen scaffolds with good thermal stability (>150 °C) were obtained and employed as liver-regenerative 3D printing biomaterials for cell-based liver therapies.


2019 ◽  
Vol 19 (01) ◽  
pp. 1850044
Author(s):  
K. Ramachandran ◽  
P. Navaneethakrishnan ◽  
M. Sivaraja

The homogeneous and substantial dispersion of nanoparticles into base fluids is vital since the final properties of any nanolubricant are estimated by their quality of stability. This paper addresses the effect of NiO nanoparticles dispersion into SN500 lubricant oil and its nonisothermal thermo stability. The dispersion of NiO nanoparticles is achieved by ultrasonication method. The thermo stability is estimated by Thermo Gravimetric Analysis (TGA), Differential Thermal Analysis (DTA) and Differential Scanning Calorimetry (DSC). The result shows that the thermo stability of base fluid enhances up to 0.3[Formula: see text]wt.% particle concentration then it decreases due to agglomeration of dispersed nanoparticles. The findings recommend that 0.1[Formula: see text]wt.% and 0.3[Formula: see text]wt.% of NiO-nanolubricant can be used for the temperature-dependent applications up to 200∘C.


Author(s):  
Abdel-Hamid I. Mourad ◽  
Mouza S. Al Mansoori ◽  
Lamia A. Al Marzooqi ◽  
Farah A. Genena ◽  
Nizamudeen Cherupurakal

Kevlar composite materials are getting scientific interest in repairing of oil and gas pipelines in both offshore and onshore due to their unique properties. Curing is one of the major factor in deciding the final mechanical performance of laminated Kevlar/epoxy nanocomposites. The parameters such as curing time, temperature and applied pressure during the hot pressing will affect chemistry of crosslinking of the epoxy matrix and interaction of epoxy with the Kevlar fiber. The present study is carried out to evaluate the optimal curing conditions of the Kevlar/epoxy nanocomposites. Three different nanofillers (namely Multi walled Carbon nanotubes (MWCNT), Silicon Carbide (SiC) and Aluminum Oxide (Al2O3)) are incorporated in different weight percentage. Differential Scanning Calorimetry (DSC) and Thermo-Gravimetric Analysis (TGA) tests are carried out to determine the thermal stability and optimal curing conditions. Mechanical performance is investigated by conducting flexure, and drop weight tests. The results show that, the optimal curing temperature for maximizing the mechanical properties is at 170°C. Peeling off the Kevlar layers are observed for nanocomposite samples cured under 100°C. Mechanical strength of the composites is enhanced by optimizing the curing conditions and nanofiller contents.


Author(s):  
Samer K. Ali ◽  
Eman B. H. Al-Khedairy

            Atorvastatin (ATR) is poorly soluble anti-hyperlipidemic drug; it belongs to the class II group according to the biopharmaceutical classification system (BCS) with low bioavailability due to its low solubility. Solid dispersions adsorbate is an effective technique for enhancing the solubility and dissolution of poorly soluble drugs.           The present study aims to enhance the solubility and dissolution rate of ATR using solid dispersion adsorption technique in comparison with ordinary solid dispersion. polyethylene glycol 4000 (PEG 4000), polyethylene glycol 6000 (PEG 6000), Poloxamer188 and Poloxamer 407were used as hydrophilic carriers and Aerosil 200, Aerosil 300 and magnesium aluminium silicate (MAS) as adsorbents.            All solid dispersion adsorbate (SDA) formulas  were prepared in ratios of 1:1:1  (drug: carrier: adsorbent) and evaluated for their water solubility, percentage yield, drug content,  , dissolution, crystal structure using  X-ray powder diffraction (XRD) and Differential Scanning Calorimetry (DSC)  studies and Fourier Transform Infrared Spectroscopy (FTIR) for determination the drug-carrier- adsorbate interaction.                The prepared (SDA) showed significant improvement of drug solubility in all prepared formula. Best result was obtained with formula SDA12(ATR :Poloxamer407 : MAS 1:1:1) that showed 8.07 and 5.38  fold increase in solubility compared to  solubility of pure ATR and  solid dispersion(SD4) (Atorvastatin: Poloxamer 407 1:1) respectively due to increased wettability and reduced crystallinity of the drug which leads to improve drug solubility  and  dissolution .


Polymers ◽  
2020 ◽  
Vol 12 (9) ◽  
pp. 2136
Author(s):  
Eric Luis ◽  
Houwen Matthew Pan ◽  
Anil Kumar Bastola ◽  
Ram Bajpai ◽  
Swee Leong Sing ◽  
...  

Osteoarthritis of the knee with meniscal pathologies is a severe meniscal pathology suffered by the aging population worldwide. However, conventional meniscal substitutes are not 3D-printable and lack the customizability of 3D printed implants and are not mechanically robust enough for human implantation. Similarly, 3D printed hydrogel scaffolds suffer from drawbacks of being mechanically weak and as a result patients are unable to execute immediate post-surgical weight-bearing ambulation and rehabilitation. To solve this problem, we have developed a 3D silicone meniscus implant which is (1) cytocompatible, (2) resistant to cyclic loading and mechanically similar to native meniscus, and (3) directly 3D printable. The main focus of this study is to determine whether the purity, composition, structure, dimensions and mechanical properties of silicone implants are affected by the use of a custom-made in-house 3D-printer. We have used the phosphate buffer saline (PBS) absorption test, Fourier transform infrared (FTIR) spectroscopy, surface profilometry, thermo-gravimetric analysis (TGA), X-ray photoelectron spectroscopy (XPS), differential scanning calorimetry (DSC), and scanning electron microscopy (SEM) to effectively assess and compare material properties between molded and 3D printed silicone samples.


Sign in / Sign up

Export Citation Format

Share Document