Purpose. To study the influence of the carbonizing agent structure on the formation of thermal insulating char layer of intumescent system acid donor/polyol and on the fire protection efficiency of the system at high temperatures. Methodology. A fire retardant mixture of an acid donor (phosphates ammonium, urea, melamine)/ polyol was chosen as a model intumescent system. Dispersion of vinyl acetate copolymer with ethylene was used as a polymeric component. The study applied the characteristics of the char layer of the intumescent composition at a certain temperature. The volumetric intumescent coefficient (K, cm3/g), mass of char residue (m, %), structure and density of the char layer are proposed as the main estimated parameters of flame retardant effect. IR spectroscopy was used to identify products of thermolysis of intumescent systems. Determination of fire protection efficiency of intumescent coatings was carried out in a mini-oven under standard fire conditions. Findings. The influence of polyol structure on the formation of thermal insulating char layer of intumescent acid donor/polyol system and the prediction of fire protection efficiency of this system under high temperature conditions has been investigated. It has been shown that under conditions of thermal shock the fire protection efficiency is more dependent on the nucleophilic reactivity of the polyol towards the unsaturated phosphorus atom of the acid donor than on its thermal stability. It has been found that pentaerythritol, dipentaerythritol, starch, dextrin, xylitol and sorbitol are the most effective carbonizing agents, regardless of the structure of the acid donor. It has been proved by infrared spectroscopy that at high temperatures as a result of the decomposition of pentaerythritol one of the reaction products is the aldehydes interacting with pentaerythritol with the formation of oligomeric compounds with a simple ether bond C-O-C. At the same time, pentaerythritol can be considered as a universal source of carbon framework for intumescent flame retardants regardless of the phosphate structure used. Originality. It has been shown that an important factor to increase the fire protection efficiency of intumescent systems is the use of polyols with an increased nucleophilicity in the esterification between polyol and phosphoric acid.Practical value. The optimal polyols as carbonizing agents for formulation of intumescent coatings with enhanced fire protection properties have been determined.


2022 ◽  
pp. 69-80
Author(s):  
LIUBOV VAKHITOVA ◽  
KONSTANTIN KALAFAT ◽  
NADIYA TARAN ◽  
VOLODYMYR BESSARABOV

Purpose. Study of influence of blowing agents amines structure on the construction processes of thermal insulating char layer of intumescent system ammonium polyphosphate/pentaerythritol/amine and fire protection efficiency of this system at high temperatures. Methodology. A fire retardant mixture of ammonium polyphosphate/pentaerythritol/amine was chosen as a model intumescent system. Dispersion of vinyl acetate copolymer with vinyl ether of versatic acid was used as a polymeric component. A step-by-step study of the characteristics of the char layer of the intumescent composition was applied in the study, consisting in the analysis of the characteristics of the char formed after keeping the intumescent composition samples at a certain temperature between 100 and 800 °C, char residue mass (m, %), structure and density of the formed char layer. The method of infrared spectroscopy was used for identification of products of thermolysis of intumescent systems. Determination of fire protection efficiency of intumescent coatings was carried out in a mini-oven under standard fire conditions. Findings. The influence of the structure of amines blowing agents on the formation of char layer of intumescent system ammonium polyphosphate/pentaerythritol/amine was studied. Physico-chemical parameters of char layer formed during high temperature swelling of intumescent system components with varying amine: urea, melamine, dicyandiamide, guanidine, thiocarbamide, formylthiosemicarbazide, thiosemicarbazide, phenylethylcarbamide have been determined. In the temperature range 200–400 oC for systems with linear amines (urea, thiocarbamide, thiosemicarbazide), there is a rapid formation of insulating layer with intense outgassing (high intumescent coefficients K) and the same rapid its destruction with significant losses of char residue mass (Δm). The presence of melamine, dicyandiamide and guanidine in intumescent system provides constancy of intumescent coefficient at minimal mass loss. Chemical transformations of intumescent systems were studied by the method of infrared spectroscopy when the investigated amines were varied. It was found that linear diamines do not form stable spatially branched phosphamide compounds with phosphates as the basis of a thermostable heat-insulating frame. At the same time in IR spectra of char residue systems with melamine, dicyandiamide and guanidine the absorption bands of P-N-C bonds (1070–1050 cm-1) and P-N (980–950 cm-1) up to 600–700 oC are observed. Fire tests proved that melamine, dicyandiamide and guanidine are blowing agents providing maximum protection of metal against fire and can be used for composition of fire retardants for steel constructions.Originality. It has been proved that amines in intumescent polyphosphate system perform at least two functions: blowing agents by means of thermal destruction to incombustible gases and nucleophilic compound that takes part in char layer formation by aminolysis of electrophilic substrates.Practical value. The optimum amine blowing agents for developing formulations of intumescent coatings with enhanced flame retardant properties have been established.


Author(s):  
Zezhong Shan ◽  
Minghui Tian ◽  
Xiang Lu

AbstractGlass fiber-reinforced polymer materials have been effectively used in civil aviation aircraft, but due to low electrical conductivity, a large area of ablation damage will occur after lightning strikes, which greatly threatens the safety of civil aircrafts. Based on this, the coupled electrical-thermal finite element analysis model for a lightning ablation damage of glass fiber reinforced polymer materials is established, and the analysis results are compared with the experiment, and the error rate is 1.26%, which verifies the accuracy of the model. In addition, different influencing factors are analyzed to study the lightning protection characteristics of glass fiber reinforced polymer on carbon fiber-reinforced polymer laminates. The results show that glass fiber reinforced polymer materials have low lightning resistance, but they can effectively reduce the lightning ablation damage area of carbon fiber reinforced polymer laminates under the joint protection of them and aluminum coating. However, they have different protective effects on different protective forms of laminates. Among them, the thickness of aluminum coating has a higher impact on the lightning protection efficiency of full spraying aluminum protective laminates, and the thickness of glass fiber reinforced polymer materials has a higher impact on the lightning protection efficiency of local spraying aluminum protective laminates.


Author(s):  
A.P. Loperena ◽  
I.L. Lehr ◽  
S.B. Saidman

Duplex coating consisting of an inner cerium-based layer and polypyrrole (PPy) film topcoat was electrodeposited onto AISI 304 stainless steel. The cerium-based coating was electrodeposited in solutions containing cerium nitrate at 50 ºC. The polymeric outer layer was electropolymerized in the presence of sodium bis(2-ethylhexyl) sulfosuccinate (AOT). The electrosynthesis was done under potentiostat conditions. The coatings were characterized by scanning electron microscopy (SEM) and energy dispersive x-ray spectrometry (EDX). The morphology of the double-layered cerium polypyrrole film shows a granular structure with the presence of agglomerates of small grains. The anticorrosive performance of the coatings was evaluated in sodium chloride solution by linear polarization, open circuit measurements, and electrochemical impedance spectroscopy (EIS). Single films, cerium layer and PPy coating, and the duplex film all reduce the corrosion rate of AISI 304 stainless steel in NaCl solution. The duplex coating presents an improved corrosion resistance concerning the single films. The combination of the characteristics of the single layers is responsible for the superior corrosion protection efficiency of the double-layered cerium polypyrrole coating.


2021 ◽  
Vol 22 (22) ◽  
pp. 12185
Author(s):  
Guifei Gu ◽  
Sen Yang ◽  
Xianhui Yin ◽  
Youhua Long ◽  
Yue Ma ◽  
...  

Bacterial canker caused by Pseudomonas syringae pv. actinidiae (Psa) has led to considerable losses in all major kiwifruit-growing areas. There are no commercial products in the market to effectively control this disease. Therefore, the defense resistance of host plants is a prospective option. In our previous study, sulfur could improve the resistance of kiwifruit to Psa infection. However, the mechanisms of inducing resistance remain largely unclear. In this study, disease severity and protection efficiency were tested after applying sulfur, with different concentrations in the field. The results indicated that sulfur could reduce the disease index by 30.26 and 31.6 and recorded high protection efficiency of 76.67% and 77.00% after one and two years, respectively, when the concentration of induction treatments was 2.0 kg/m3. Ultrastructural changes in kiwifruit stems after induction were demonstrated by scanning electron microscopy (SEM) and transmission electron microscopy (TEM), and the activities of phenylalanine ammonia-lyase (PAL), peroxidase (POD) and polyphenol oxidase (PPO), and the accumulation of lignin were determined by biochemical analyses. Our results showed that the morphological characteristics of trichomes and lenticels of kiwifruit stem were in the best defensive state respectively when the sulfur concentration was 3.0 kg/m3 and 1.5 kg/m3. Meanwhile, in the range of 0.5 to 2.0 kg/m3, the sulfur could promote the chloroplast and mitochondria of kiwifruit stems infected with Psa to gradually return to health status, increasing the thickness of the cell wall. In addition, sulfur increased the activities of PAL, POD and PPO, and promoted the accumulation of lignin in kiwifruit stems. Moreover, the sulfur protection efficiency was positively correlated with PPO activity (p < 0.05) and lignin content (p < 0.01), which revealed that the synergistic effect of protective enzyme activity and the phenolic metabolism pathway was the physiological effect of sulfur-induced kiwifruit resistance to Psa. This evidence highlights the importance of lignin content in kiwifruit stems as a defense mechanism in sulfur-induced resistance. These results suggest that sulfur enhances kiwifruit canker resistance via an increase in phenolic components and morphology structure modification in the kiwifruit stems. Therefore, this study could provide insights into sulfur to control kiwifruit canker caused by Psa.


2021 ◽  
Vol 1167 ◽  
pp. 13-22
Author(s):  
C.C. Soumya ◽  
K.E. George ◽  
Sunil K. Narayanankutty

Organic acid doped polyaniline (PANI), hybrid with silica gel (SiG) and composites with metal primer have been prepared by chemical oxidative polymerization of double-distilled aniline in an acidic medium at 0-5 °C in an ice bath using ammonium persulphate as oxidant and p-toluene sulphonic acid (p-TSA) as the dopant. The anticorrosive property of PANI coatings containing alkyd primer, zinc chromate and silica gel was investigated. The coatings were characterized by FTIR spectroscopy, scanning electron microscopy and electrochemical impedance spectroscopy. The corrosion studies were carried out in a 3.5 wt% NaCl solution. On introduction of SiG, PANI, and PANI-SiG hybrid, the corrosion current decreased from 0.03626 μA to 0.007856 μA, 0.02042 μA, and 0.011 μA, respectively. The penetration rates calculated in mm/yr. for the composites: SiG/Primer, PANI/Primer and PANI-SiG/Primer were 0.430× 10-4, 1.110× 10-4, and 0.599 × 10-4, respectively and that of neat primer was 1.977 × 10-4. The corrosion protection efficiency of the primer was improved up to 7% on introduction of the PANI-based fillers. The 5 wt% of 1:1 PANI-SiG/primer composite, which contains 2.5wt% of PANI, showed better results than that of 5wt% PANI in Primer and these results are very close to that of 5wt% SiG/Primer composites.


2021 ◽  
Author(s):  
RK GUNTU

Abstract The research on Cr2O3 doped SiO2 glasses is well known for advanced dielectrics. However, there are many other valuable properties associated with Cr2O3 inclusive various glasses. In this view, the current research aimed to develop the radiation shielding, elastically rich, and the EPR based Cr2O3 doped Ba(La)2SiO6 glass resource. Electron paramagnetic resonance, radiation shielding, and elastic studies have been employed to investigate the advanced characteristics. Structural characterization suggests glassy behavior with the Cr2O3 undoped glass. Whereas the other involved with Cr2O3 mol% shown with the ceramic behavior. The glass transition phenomena and forming abilities are studied with the help of differential thermal analysis techniques. Elastic studies have been done with the limit on the glasses, which suggests the glasses are flexible for elastic use. The electron paramagnetic resonance reports suggest high order of dipole-dipole super-exchange interaction and rhombohedral distortion within the glasses. Furthermore, we have tested the glasses for radiation shielding properties. The values of mass attenuation coefficient, radiation protection efficiency, mean free path, and energy absorption build-up factor of the glasses are measured and compared with values obtained with the help of standard photon shielding and dosimetry software. The studies indicate that the glasses developed are capable of radiation shielding. Upon 50 kGy, γ - irradiation, the thermoluminescence properties of the glasses are reported. The results found to be interesting, and reveal the resource developed are thermoluminescent at low activation energies. Furthermore, we have tested, the glasses for radiation shielding properties. Moreover, to introduce the detailed correlation between electron paramagnetic resonance, and thermoluminescence phenomenon, we have annealed the glasses under 0 to 300 oC temperature and upon the 0 to 50 kGy, γ - irradiation dose level. The electron paramagnetic resonance and thermoluminescence properties obtained for the glasses are highly correlative.


2021 ◽  
Vol 13 (11) ◽  
pp. 283
Author(s):  
Michael Alicea ◽  
Izzat Alsmadi

Firewalls and network access controls play important roles in security control and protection. Those firewalls may create an incorrect sense or state of protection if they are improperly configured. One of the major configuration problems in firewalls is related to misconfiguration in the access control roles added to the firewall that will control network traffic. In this paper, we evaluated recent research trends and open challenges related to firewalls and access controls in general and misconfiguration problems in particular. With the recent advances in next-generation (NG) firewalls, firewall roles can be auto-generated based on networks and threats. Nonetheless, and due to the large number of roles in any medium to large networks, roles’ misconfiguration may occur for several reasons and will impact the performance of the firewall and overall network and protection efficiency.


2021 ◽  
Vol 895 (1) ◽  
pp. 012020
Author(s):  
J Li ◽  
S Dong ◽  
Y Li

Abstract Pinus sylvestris, Artemisia ordosica, Tamarix chinensis Lour, Elaeagnus angustifolia and Salix matsudana Koidz were selected to design the models of forest belts. Through wind tunnel experiments, we analyzed the wind speed frequency, wind speed flow field and wind protection efficiency of two different configuration shelterbelts. The results showed the wind speed frequency of mixed shelterbelts was generally lower than that of single shelterbelts with the same configuration. The similarity of the average wind speed between No.1 A3 and No.2 C3 indicates that the windbreak effect of low-density arbor-shrub mixed shelterbelt was similar to that of high-density single shelterbelt. The average wind protection efficiency of No.1 A1 was similar to that of No.1 C2, indicating that the influence of density of pinus sylvestrison of wind protection efficiency is greater than the height of forest belt. the average wind protection efficiency of No. 2 A2 was 57.64%, which was similar to that of No. 2 B3, indicating that the height of the forest belt increased, and the influence of density on the protection effect of the forest belt decreased.Therefore, the wind protection ability of multi-species and highly hierarchical mixed forests was higher than that of single shelterbelt.