scholarly journals EXPOSURE EFFECT OF MAGNETIC FIELD ON WATER PROPERTIES IN RECIRCULATION AQUACULTURE SYSTEMS(RAS)

2018 ◽  
Vol 49 (6) ◽  
Author(s):  
Hassan & et al.

The objective of this study to investigate the effect of magnetic field on water properties recirculatingaquaculture systems. This study is based on previous works reporting the positive effects of exposureto magnetic field on water properties, plant growth, plant germination, livestock-drinking water, andfish fertilisation. It was conducted against the backdrop of serious issues pertaining to water quality inrecirculating aquaculture systems, which negatively impact aquaculture species growth. First, thiswork evaluates the effect of exposed to magnetic field intensities of 0.10, 0.15, 0.20, 0.10+0.15,0.10+0.20, 0.15+0.20, and 0.10+0.15+0.20 T on water quality. The results showed significant (p < 0.05)increases of the dissolved oxygen (DO), pH, and conductivity(CD) by 17.3, 1.6, 3.0%, respectively, andsignificant decreases of the ammonium level(NH4-N), specific conductivity(SPC), total dissolvedsolids(TDS), oxygen reduction potential(ORP), and chlorides by 25.3, 1.1, 1.4, 1.0, 16.9, 3.4%,respectively, throughout the experiment in recirculation aquaculture systems. Therefore, theinstallation of the device in recirculation aquaculture systems is simple, low cost, and can be retrofittedinto existing systems, which helps simplify fish rearing for fish farmers.

2020 ◽  
Vol 20 (2) ◽  
pp. 172-181 ◽  
Author(s):  
Silvia Sciannimanico ◽  
Franco Grimaldi ◽  
Fabio Vescini ◽  
Giovanni De Pergola ◽  
Massimo Iacoviello ◽  
...  

Background: Metformin is an oral hypoglycemic agent extensively used as first-line therapy for type 2 diabetes. It improves hyperglycemia by suppressing hepatic glucose production and increasing glucose uptake in muscles. Metformin improves insulin sensitivity and shows a beneficial effect on weight control. Besides its metabolic positive effects, Metformin has direct effects on inflammation and can have immunomodulatory and antineoplastic properties. Aim: The aim of this narrative review was to summarize the up-to-date evidence from the current literature about the metabolic and non-metabolic effects of Metformin. Methods: We reviewed the current literature dealing with different effects and properties of Metformin and current recommendations about the use of this drug. We identified keywords and MeSH terms in Pubmed and the terms Metformin and type 2 diabetes, type 1 diabetes, pregnancy, heart failure, PCOS, etc, were searched, selecting only significant original articles and review in English, in particular of the last five years. Conclusion: Even if many new effective hypoglycemic agents have been launched in the market in the last few years, Metformin would always keep a place in the treatment of type 2 diabetes and its comorbidities because of its multiple positive effects and low cost.


Micromachines ◽  
2020 ◽  
Vol 11 (5) ◽  
pp. 474 ◽  
Author(s):  
Bei Wang ◽  
Manuel Baeuscher ◽  
Xiaodong Hu ◽  
Markus Woehrmann ◽  
Katharina Becker ◽  
...  

A novel capacitive sensor for measuring the water-level and monitoring the water quality has been developed in this work by using an enhanced screen printing technology. A commonly used environment-friendly conductive polymer poly(3,4-ethylenedioxythiophene):poly (styrenesulfonate) (PEDOT:PSS) for conductive sensors has a limited conductivity due to its high sheet resistance. A physical treatment performed during the printing process has reduced the sheet resistance of printed PEDOT:PSS on polyethylenterephthalat (PET) substrate from 264.39 Ω/sq to 23.44 Ω/sq. The adhesion bonding force between printed PEDOT:PSS and the substrate PET is increased by using chemical treatment and tested using a newly designed adhesive peeling force test. Using the economical conductive ink PEDOT:PSS with this new physical treatment, our capacitive sensors are cost-efficient and have a sensitivity of up to 1.25 pF/mm.


2019 ◽  
Author(s):  
Jeba Anandh S ◽  
Anandharaj M ◽  
Aswinrajan J ◽  
Karankumar G ◽  
Karthik P

2017 ◽  
Vol 31 (25) ◽  
pp. 1745001 ◽  
Author(s):  
Qiudong Guo ◽  
Peng Zhang ◽  
Lin Bo ◽  
Guibin Zeng ◽  
Dengqian Li ◽  
...  

With the rapid development of manufacturing technology of high temperature superconductive YB[Formula: see text]Cu3O[Formula: see text] YBCO materials and decreasing in cost of production, YBCO is marching into industrial areas with its good performances as source of high-magnetic field and rather low cost in reaching superconductivity. Based on analysis of the performance of high temperature superconductors YBCO and development of technology in superconductive magnetic separation both home and abroad, we propose a new approach of taking YBCO tape to make a solenoid as the source of a high magnetic field of magnetic separatior of ores. The paper also looks into the future of the YBCO high temperature superconductive magnetic separation from the perspective of technology and cost, as well as its applications in other industries.


2011 ◽  
Vol 1 (1) ◽  
pp. 68-85 ◽  
Author(s):  
Patty Chuang ◽  
Stephanie Trottier ◽  
Susan Murcott

The UN defines water supplies as ‘improved’ or ‘unimproved.’ These indicators are easy to measure, but do not reflect water quality, which requires laboratory or field tests. Laboratory and test availability, expense and technical capacity are obstacles for developing countries. This research compares and verifies four low-cost, field-based microbiological tests: the EC-Kit (Colilert® and Petrifilm™ tests), the H2S bacteria test, and Easygel®, against a standard method (Quanti-Tray®). The objectives are to: (1) verify the accuracy of the four field-based tests, (2) study the accuracy of these tests as a function of improved and unimproved sources; (3) recommend a single microbiological test, if appropriate, based on accuracy and cost, and/or (4) recommend a testing combination, if appropriate, based on accuracy and cost. The tests of 500+ total water samples from Capiz Province, Philippines and Cambridge, MA indicate that two-tests systems gave better results than a single test. Both the 100-mL H2S test + Petrifilm™ and the 20-mL H2S test + Easygel® combinations yield promising results, in addition to being inexpensive. None of the field-based tests should be used on their own. We recommend further verification of a larger sample size and scale be undertaken before these testing combinations are recommended for wider use.


Sensors ◽  
2021 ◽  
Vol 21 (6) ◽  
pp. 2218
Author(s):  
Sizhen Bian ◽  
Peter Hevesi ◽  
Leif Christensen ◽  
Paul Lukowicz

Autonomous underwater vehicles (AUV) are seen as an emerging technology for maritime exploration but are still restricted by the availability of short range, accurate positioning methods necessary, e.g., when docking remote assets. Typical techniques used for high-accuracy positioning in indoor use case scenarios, such as systems using ultra-wide band radio signals (UWB), cannot be applied for underwater positioning because of the quick absorption of the positioning medium caused by the water. Acoustic and optic solutions for underwater positioning also face known problems, such as the multi-path effects, high propagation delay (acoustics), and environmental dependency. This paper presents an oscillating magnetic field-based indoor and underwater positioning system. Unlike those radio wave-based positioning modalities, the magnetic approach generates a bubble-formed magnetic field that will not be deformed by the environmental variation because of the very similar permeability of water and air. The proposed system achieves an underwater positioning mean accuracy of 13.3 cm in 2D and 19.0 cm in 3D with the multi-lateration positioning method and concludes the potential of the magnetic field-based positioning technique for underwater applications. A similar accuracy was also achieved for various indoor environments that were used to test the influence of cluttered environment and of cross environment. The low cost and power consumption system is scalable for extensive coverage area and could plug-and-play without pre-calibration.


2021 ◽  
Author(s):  
Jean Grégoire Boero Rollo ◽  
John Richard Ordonez Varela ◽  
Tayssir Ben Ghzaiel ◽  
Cedric Mouanga ◽  
Arnaud Luxey ◽  
...  

Abstract Wireless Autonomous Nano-sensor Device (WAND) system is a disruptive cost-effective micro-system for well monitoring. It allows to realize pressure, temperature, inertial, and magnetic field measurements in harsh conditions; it also offers Bluetooth low-power communication and Wireless charging capabilities. Analysis’ results of an industrial offshore pilot realized in Congo (a world first in O&G industry in such complex environment), and major improvements implemented after this pilot are reported in this paper. Accomplished advancements comprise hardware and software developments extending operation lifetime, and simplifying on-site utilization. To date, there is not a commercial solution of this type in the market, the realization of this project is a real innovation allowing practical and low-cost monitoring during well intervention while minimizing the risks associated with standard Rigless intervention. Other applications regarding dry-tree wells on tension-leg platforms (TLP), drilling and completion operations, and pipeline monitoring are being investigated, too.


Sign in / Sign up

Export Citation Format

Share Document