Suppression of Surface Effect by Using Bent-Perfect-Crystal Monochromator in Residual Strain Scanning

Author(s):  
Miroslav Vrána ◽  
P. Mikula
2005 ◽  
Vol 490-491 ◽  
pp. 234-238 ◽  
Author(s):  
Miroslav Vrána ◽  
Pavol Mikula

Using our long experience in Bragg diffraction optics we successfully used focusing principles for substantial increasing both luminosity and resolution of the strain scanners with respect to the conventional devices. Monochromatic neutrons are selected by the cylindrically bent monochromator from the reactor spectrum. There is a strong correlation between divergences of incoming and outgoing beams with respect to the polycrystalline sample, which can be easily manipulated by changing the monochromator bending radius. By setting a proper value of the radius, a narrow, quasiparallel and highly luminous output beam can by adjusted. The strong correlation between wavelength and direction of incoming and outgoing beams depending on the monochromator bending radius can be as well used for suppression of surface effect in residual strain scanning. In scanning near a sample surface aberration peak shifts arise due to the fact that the gauge volume defined by input and output slits is partially out of the sample and its value can be of the same order as the residual strain effects. In this work we demonstrate that by changing of the bending radius of monochromator, this surface effect can be suppressed to values smaller then experimental errors in residual strain scanning.


Micromachines ◽  
2021 ◽  
Vol 12 (5) ◽  
pp. 529
Author(s):  
Chunzhi Du ◽  
Zhifan Li ◽  
Bingfei Liu

Nanoporous Shape Memory Alloys (SMA) are widely used in aerospace, military industry, medical and health and other fields. More and more attention has been paid to its mechanical properties. In particular, when the size of the pores is reduced to the nanometer level, the effect of the surface effect of the nanoporous material on the mechanical properties of the SMA will increase sharply, and the residual strain of the SMA material will change with the nanoporosity. In this work, the expression of Young’s modulus of nanopore SMA considering surface effects is first derived, which is a function of nanoporosity and nanopore size. Based on the obtained Young’s modulus, a constitutive model of nanoporous SMA considering residual strain is established. Then, the stress–strain curve of dense SMA based on the new constitutive model is drawn by numerical method. The results are in good agreement with the simulation results in the published literature. Finally, the stress-strain curves of SMA with different nanoporosities are drawn, and it is concluded that the Young’s modulus and strength limit decrease with the increase of nanoporosity.


2013 ◽  
Vol 46 (3) ◽  
pp. 628-638 ◽  
Author(s):  
Jan Šaroun ◽  
Joana Rebelo Kornmeier ◽  
Michael Hofmann ◽  
Pavol Mikula ◽  
Miroslav Vrána

Residual strains measured by neutron diffraction near sample boundaries can be biased by the surface effect as a result of incomplete filling of the instrumental gauge volume. This effect is manifested as anomalous shifts of diffraction lines, which can be falsely interpreted as a lattice strain unless appropriate data corrections are made. A new analytical model for the surface effect has been developed, which covers a broad variety of instrumental arrangements, including flat mosaic and bent perfect crystal monochromators, narrow slits, and Soller and radial collimators. This model permits the spurious peak shifts to be predicted quantitatively, and also allows the optimum configuration parameters, such as curvature of a focusing monochromator, which lead to suppression of the surface effect, to be calculated. The model has been thoroughly validated by comparisons with Monte Carlo simulations and experiments on a stress-free calibration sample. Predictions of the model proved to be very accurate, often within the interval of experimental errors, which makes it suitable for use in data analysis.


2011 ◽  
Vol 681 ◽  
pp. 426-430 ◽  
Author(s):  
Baek Seok Seong ◽  
Vyacheslav T. Em ◽  
Pavol Mikula ◽  
Jan Šaroun ◽  
Mi Hyun Kang

In this paper properties of the dedicated neutron strain/stress diffractometer installed at the beam port ST-1 of HANARO reactor in KAERI which has been optimized at a small monochromator take-off angle, are described. Thanks to the employment of the horizontally focusing bent perfect crystal monochromator and the optimization procedure good resolution can be achieved and namely, the luminosity of the instrument can be considerably increased which permits us to enlarge the range of the material depth for residual strain/stress mapping. Moreover, new alternative of the diffractometer permits also to investigate some kinetic processes in polycrystalline materials running within few seconds.


Author(s):  
L. Fei ◽  
P. Fraundorf

Interface structure is of major interest in microscopy. With high resolution transmission electron microscopes (TEMs) and scanning probe microscopes, it is possible to reveal structure of interfaces in unit cells, in some cases with atomic resolution. A. Ourmazd et al. proposed quantifying such observations by using vector pattern recognition to map chemical composition changes across the interface in TEM images with unit cell resolution. The sensitivity of the mapping process, however, is limited by the repeatability of unit cell images of perfect crystal, and hence by the amount of delocalized noise, e.g. due to ion milling or beam radiation damage. Bayesian removal of noise, based on statistical inference, can be used to reduce the amount of non-periodic noise in images after acquisition. The basic principle of Bayesian phase-model background subtraction, according to our previous study, is that the optimum (rms error minimizing strategy) Fourier phases of the noise can be obtained provided the amplitudes of the noise is given, while the noise amplitude can often be estimated from the image itself.


Author(s):  
B. R. Ahn ◽  
N. J. Kim

High energy approximation in dynamic theory of electron diffraction involves some intrinsic problems. First, the loss of theoretical strictness makes it difficult to comprehend the phenomena of electron diffraction. Secondly, it is difficult to believe that the approximation is reasonable especially in the following cases: 1) when accelerating voltage is not sufficiently high, 2) when the specimen is thick, 3) when the angle between the surface normal of the specimen and zone axis is large, and 4) when diffracted beam with large diffraction angle is included in the calculation. However, until now the method to calculate the many beam dynamic electron diffraction without the high energy approximation has not been proposed. For this reason, the authors propose a method to eliminate the high energy approximation in the calculation of many beam dynamic electron diffraction. In this method, a perfect crystal with flat surface was assumed. The method was applied to the calculation of [111] zone axis CBED patterns of Si.


Author(s):  
D. Goyal ◽  
A. H. King

TEM images of cracks have been found to give rise to a moiré fringe type of contrast. It is apparent that the moire fringe contrast is observed because of the presence of a fault in a perfect crystal, and is characteristic of the fault geometry and the diffracting conditions in the TEM. Various studies have reported that the moire fringe contrast observed due to the presence of a crack in an otherwise perfect crystal is distinctive of the mode of crack. This paper describes a technique to study the geometry and mode of the cracks by comparing the images they produce in the TEM because of the effect that their displacement fields have on the diffraction of electrons by the crystal (containing a crack) with the corresponding theoretical images. In order to formulate a means of matching experimental images with theoretical ones, displacement fields of dislocations present (if any) in the vicinity of the crack are not considered, only the effect of the displacement field of the crack is considered.The theoretical images are obtained using a computer program based on the two beam approximation of the dynamical theory of diffraction contrast for an imperfect crystal. The procedures for the determination of the various parameters involved in these computations have been well documented. There are three basic modes of crack. Preliminary studies were carried out considering the simplest form of crack geometries, i. e., mode I, II, III and the mixed modes, with orthogonal crack geometries. It was found that the contrast obtained from each mode is very distinct. The effect of variation of operating conditions such as diffracting vector (), the deviation parameter (ω), the electron beam direction () and the displacement vector were studied. It has been found that any small change in the above parameters can result in a drastic change in the contrast. The most important parameter for the matching of the theoretical and the experimental images was found to be the determination of the geometry of the crack under consideration. In order to be able to simulate the crack image shown in Figure 1, the crack geometry was modified from a orthogonal geometry to one with a crack tip inclined to the original crack front. The variation in the crack tip direction resulted in the variation of the displacement vector also. Figure 1 is a cross-sectional micrograph of a silicon wafer with a chromium film on top, showing a crack in the silicon.


1985 ◽  
Vol 54 (04) ◽  
pp. 833-837 ◽  
Author(s):  
N A Marsh ◽  
P M Peyser ◽  
L J Creighton ◽  
M Mahmoud ◽  
P J Gaffney

SummaryPentosan polysulphate causes an increase in plasminogen activator activity in plasma both after oral ingestion and after subcutaneous injection. The effect is greatest after 3 h and has disappeared by 6 h. Repeat doses by mouth over 5 days elicit a similar response. The recorded increase in activity is due largely to the release of tissue-type plasminogen activator (tPA) from the endothelium according to the antigen assay although there could be a small contribution from Factor XH-related “intrinsic” fibrinolysis induced in vitro. SP54 enhances activity ex vivo by a non-specific surface effect, and this phenomenon may contribute the increased levels of activity seen in vitro. Administration of SP54 to animals elicits a similar increase in activator activity, the intramuscular route being slightly more effective. Results with an inferior vena cava thrombosis model in the rat suggest that pentosan polysulphate may induce a thrombolytic effect.


2013 ◽  
Vol 12 (3) ◽  
Author(s):  
Iskendar Iskendar ◽  
Andi Jamaludin ◽  
Paulus Indiyono

This paper describes hydrodynamic model tests of Wing in Surface Effect (WiSE) Craft. These craft  was fitted with  stephull  form in different location on longitudinal flat bottom (stepedhull planning craft) to determine the influences of sticking and porpoising motion performances. These motions are usually occured when the craft start to take-off from water surfaces. The test models with scale of 1 : 7 were comprised of 4 (four) stephull models and 1 (one) non-stephull model  as a comparative study. The hydrodynamic  tests were performed with craft speed of 16 – 32 knots (prototype values) in Towing Tank at UPT. Balai Pengkajian dan Penelitian Hidrodinamika (BPPH), BPPT, Surabaya. The resistance (drag) was measured by dynamo meter and the trim of model (draft changing at fore and aft  of model due to model speed) was measured by trim meter. By knowing the value of model trim, the wetted surface area can be determined. Then, the lift forces were calculated based on these measured values. The model test results were presented on tables and curves.  Test results show that models  with step located far away from center of gravity of the WiSE craft tend to porpoising and sticking condition, except if the step location on the below of these center of gravity. While model without step tends to sticking conditions.


2004 ◽  
Vol 95 (5) ◽  
pp. 340-344 ◽  
Author(s):  
P. Dobrosz ◽  
S. J. Bull ◽  
S. H. Olsen ◽  
A. G. O'Neill