Use of Natural Ventilation in Malaysia's Future Green Housing

2014 ◽  
Vol 935 ◽  
pp. 316-319
Author(s):  
Alireza Gharakhani ◽  
Eka Sediadi ◽  
Tareef Hayat Khan ◽  
Hadi Bagheri Sabzevar

Within the Asia Pacific region, Malaysias WAWASAN 2020 creates the vision of being a green country. Accordingly, the Malaysian Government has established the mission of reducing the carbon emission. The programs include the projects targeting the energy efficiency and saving within the housing and residential buildings that must meet the Green Building criteria to achieve the sustainable architectural design. Renewable energy sources, like wind or solar energy, can be used to ventilate. The review of previous researchers shows that the use of the natural ventilation system decreases the electricity consumption of a simulated housing in the hot and humid climatic conditions such as Malaysia. The purpose of this research is a review of consumes renewable energies such as solar energy and wind for passive cooling. To test the benefit of natural ventilation system, this paper reviewed some analysis that had used simulation software such as CFD.

2018 ◽  
Vol 878 ◽  
pp. 202-209 ◽  
Author(s):  
Feng Qian ◽  
Li Yang

The natural ventilation of residential areas has placed more and more emphasis on residential area planning, according to the relationship between natural ventilation environments and the layout of architecture, we can reduce the energy consumption and the adverse effect of wind outdoors, improve the living environment and quality of life, making harmony between human and the nature. In this paper, we use Air-Pak to simulate the wind environment of residential areas. Through analyzing and simulating the air field which forms when the wind blows around the residential buildings by Air-Pak, we explain the advantage of the combination of computer simulation software and residential area planning. And we give some advice to the layout of the outdoor environment early in the residential planning area by the simulation of outdoor environments of buildings.


2020 ◽  
Vol 3 (1) ◽  
pp. p1
Author(s):  
Jad Hammoud ◽  
Elise Abi Rached

The increasing of energy demands has considerably increased the requirements for new and traditional buildings in different climate zones. Unprecedented heat waves have increased climate temperature, in particular, in moderate climate zones such as Lebanon. In Beirut, only the residential sector consumes 50% of total electricity consumption. HVAC (Heating, Ventilation and Air conditioning) systems are used to reach acceptable thermal comfort levels in the new residential buildings. In case of the traditional bourgeoisie houses in Beirut, there are no discussions about the use of HVAC systems to achieve the required thermal comfort level. Thus, to reach an acceptable thermal comfort level, these houses which already contain natural ventilation system shall adapt the modern thermal comfort requirements and thermal comfort strategies and technologies where their architectural features and existing materials condition the available solutions. In order to identify the best options within the possible intervention lines (envelopes, passive strategies, equipment, renewable energy systems), it is necessary to perceive the real performance of this type of houses. In this context, the article presents the results of the study of thermal performance and comfort in a three case studies located in Beirut. Detailed field data records collected are analyzed, with a view to identify the indoor thermal environment with respect to outdoor thermal environment in different seasons. Monitoring also included measurement of hygrothermal parameters and surveys of occupant thermal sensation.


2021 ◽  
Vol 03 (04) ◽  
pp. 264-274
Author(s):  
Sardor Ilkhomovich Khamraev ◽  
◽  
Saydulla Mirzaevich Khuzhakulov ◽  
Behzodjon Ilkhomovich Kamolov ◽  
Shakhboz Khairulla Oglu Khusunov ◽  
...  

The article analyzes the results of research conducted by scientists from foreign countries and schools of Uzbekistan on the use of solar energy in the heating systems of residential buildings and sectors of the economy. As a result of a brief analysis of scientific research, it is stated that there are problems with combined heat supply systems operating on the basis of solar energy in natural conditions that are suitable for the climatic conditions and solar energy potential of the southern regions of the country.


2011 ◽  
Vol 6 (1) ◽  
pp. 114-122
Author(s):  
Zohreh Razavi ◽  
Max Richter ◽  
Murray Hodgson ◽  
Alireza Khaleghi

Low speech privacy in shared and private offices in one of the early generation of a “green” building resulted in occupants' dissatisfaction. This problem is experienced in Liu institute with a natural-ventilation system. Such a system requires low air-flow resistance which is achieved by large openings which will result in noise transmission between various spaces within the building. The poor acoustical quality in this building resulted in occupants' noise complaints which were further investigated by way of relevant acoustical measurements. CATT-Acoustic software was utilized to modify the acoustical quality of the building without any disturbance to the occupants. The optimized design of the transfer box above the office door was selected based on CATT-Acoustic predictions. The acoustical measurements were conducted after installation of the transfer box above the office door. The measurements' results agreed with the predictions which led to improved speech privacy to an acceptable level between the office and the corridor in Liu Institute. More work should be done to improve the acoustical quality of natural-ventilated building to conform to ANSI standards.1The results of this study strongly support including acoustics in “green” building designs with natural ventilation to avoid users' complaints.


2019 ◽  
Vol 50 (4) ◽  
pp. 180-190 ◽  
Author(s):  
Enrica Santolini ◽  
Alberto Barbaresi ◽  
Daniele Torreggiani ◽  
Patrizia Tassinari

The wine-ageing process is one of the most important phases of the wine production and it can be considerably affected by the micro-climatic conditions inside the ageing rooms. Underground wine cellars in small-medium wineries are designed with natural ventilation systems, able to maintain optimal indoor condition. However, critical factors emerge, such as mold growth or wine evapo-transpiration, where ventilation proved to be poorly designed, insufficient in the first case or excessive in the second one. The zones around the wooden barrels proved to be the most sensitive and problematic. These areas are the most investigated in terms of temperature and humidity values but surprisingly not in terms of air velocity. In this paper, a ventilation system has been designed and optimised to support the lack of ventilation, by means of computational fluid dynamics modelling. Eight configurations have been performed and analysed, identifying the best two according to the air velocity range. Specific parameters have been defined to appreciate the application limits of each configuration. These parameters can be used as reference for system design in similar studies and applications and can help scholars and professionals to identify the optimal configurations for the implementation and proper placement of the system inside a cellar.


2018 ◽  
Vol 49 ◽  
pp. 00025 ◽  
Author(s):  
Tomasz Gaczoł

In the following article the author proposes the solution for a properly functioning natural ventilation system based on the use of supply and exhaust ducts, i.e. by designing a natural balanced ventilation system. The paper is devoted to test results of air flow through natural ventilation supply-exhaust ducts in the rooms located on the lower floor of the building. The simulations conducted in ANSYS Fluent software relate to such issues as: pressure system inside the room and in the exhaust duct, distribution of air temperatures in the room, vector direction of airflow through supplyexhaust ducts and in the analysed room. Three types of solutions were selected for the tests: air inflow into the room through the air intake located at the basement level, air inflow through the window ventilator (although no longer used, this solution can be found in many existing residential buildings) and the natural ventilation system supported with the so-called “solar chimney”. All simulations were conducted with an outdoor temperature of +3 degrees C. The indoor temperature is + 20 degrees C, considered to be the minimum thermal comfort level. In the era of common building sealing, the presented ventilation system may be a good solution that guarantees proper functioning of natural ventilation. In all cases presented, it meets the normative regulations and requirements for the ventilation air stream and the air exchange rate in the room. The paper (first part) describes test results concerning the room located on the lower floor of the building, i.e. with a short supply duct and a 12-meter long exhaust duct.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Ardasher Namazbay Yussupov ◽  
Akmaral Ardasherovna Yussupova

PurposeThe purpose of this article discusses the design of underground eco-houses using a dome structure of light construction while taking into account the historical experience of the development of the local population. This article considered the traditions of folk architecture and modern sophistication in the creation of energy-efficient eco-houses in foreign countries in the context of architecture and construction of affordable residential homes for the local population.Design/methodology/approachThe research presented in this paper was motivated by the need for developing agro-tourism facilities in hard-to-reach areas of the Silk Road in Southern Kazakhstan causes the construction of eco-houses built using local construction materials. Since ancient times in Southern Kazakhstan and during seasonal migrations in yurts of light construction, people have lived in mud-brick houses deep in the ground. Along with architectural and artistic solutions in building construction, great importance was attached to saving material resources, labour costs and achieving heat stability of residential buildings.FindingsIn the architectural and planning solution of the eco¬-house, progressive directions of construction of agrotechnical structures using renewable energy sources are adopted. Particular importance was given to the choice of the construction site on an elevated area nearby historical monuments and a favourable season for the construction of eco-houses with considering the natural and climatic characteristics of rural areas of Southern Kazakhstan.Research limitations/implicationsThis paper discussed the issues of insulation, ventilation and improving the eco-house microclimate comfort using local building materials. Improving the architectural and artistic expressiveness of the eco-house in terms of the tradition of folk architecture was also explicitly discussed in this paper.Practical implicationsTables with the justification of expediency of construction of economical eco-houses in natural and climatic conditions of Kazakhstan and Central Asia are provided. The results help to improve the energy efficiency of eco-houses in Kazakhstan by using renewable energy sources.Social implicationsSocial benefits are associated with the use of local raw materials. Eco-houses built from traditional building materials can become accessible to a wide range of people and stimulate the development of small businesses. This may be associated with the construction of eco-houses to serve visiting tourists in remote picturesque oases, as well as the manufacture of dome structures, felt products and the preparation of reed panels and so on.Originality/valueThe thermotechnical characteristics of the region's ground energy are given, which can significantly save the cost of heating the eco-house. Solutions for optimal insolation, ventilation of the eco-house are provided, taking into account the natural and climatic conditions of Southern Kazakhstan.


2013 ◽  
Vol 21 (01) ◽  
pp. 1350002 ◽  
Author(s):  
YOUNES KARTACHI ◽  
ABDELLAH MECHAQRANE

In this study, we analyze the impact of ventilation heat recovery with the heating and cooling potential of earth air heat exchanger in real climatic conditions in domestic buildings in the Middle Atlas region. In our case study, we calculate the primary energy used by a domestic building built as per the conventional house design parameters required by the Moroccan regulation. We use climate data for the city of Fes in Northern Moroccan. Three system configurations were considered. The first was the mechanical extract ventilation system both with and without heat recovery. The second was the mechanical extract ventilation system with earth to air heat exchanger system (EAHEX), and the third system was the mechanical balanced ventilation system coupled with EAHEX system. Primary energy use strongly influences natural resources efficiency and the environmental impacts of energy supply activities. In this study we explore the primary energy implications of the mechanical balanced ventilation system coupled with the EAHEX system in residential buildings. The results of this study shows that the use of a balanced ventilation system, with a high efficiency instead of a mechanical extract ventilation system, decreases the final and primary energy consumption. Moreover, it decreases or increases the CO2 emission depending on the primary energy sources.


2021 ◽  
Vol 1200 (1) ◽  
pp. 012029
Author(s):  
Amirul Hakim Hasan ◽  
Sushilawati Ismail

Abstract Sustainable construction has been the main priority in the global construction industry. For that reason, Malaysia is moving towards green building approach to promote built environment sustainability. Therefore, it is essential to raise awareness about the environmental-responsible practice among construction players particularly on the implementation of green engineering-based technology. This study aims to explore the existing green engineering-based technology and to investigate the preferred green engineering-based technology to upgrade the sustainability of existing residential buildings. The study focuses on the existing technology to be incorporated in the operation of buildings. A comprehensive literature review was carried out and 384 feedback was collected from questionnaire survey distribution among respondents in Johor Bahru. Various green engineering-based technology includes solar energy, wastewater treatment, rainwater harvesting, window shading, housing landscape, natural ventilation, smart PDLC film glasses, roof thermal insulation, and smart home control panel are discussed in this paper. From this study, it was found that that the housing landscape is the most preferred with the highest mean index value followed by daylighting system and solar panel. The results indicate the preferred green engineering-based technology is because of low cost and familiarity among users. The future study should consider relating the awareness of individuals on sustainability with their preferred green technology. Perhaps, the coverage of this study should be extended by involving respondents from all over Malaysia.


Author(s):  
О. Симбирев ◽  
O. Simbirev

The main problem highlighted in the article is the deviation of the microclimate parameters from the standard values due to the improper organization of airflow in the residential rooms of apartment buildings. The objective is to obtain a working mathematical model of the natural ventilation system, its study for optimization or modernization. The analysis of the normative literature, scientific works of domestic and foreign scientists, developments in the field of natural ventilation and ventilation of residential buildings is carried out. A mathematical model of air exchange of a residential room with convection is presented and analyzed. The flow rate and air temperature, the temperature on the surface of the heater are set as boundary conditions when creating a mathematical model. The features and regularities of airflow distribution in the room obtained as a result of mathematical modeling are revealed. The distributions of air velocity in the room are given. Difficulties of the organization of effective natural inflow of air and the problems with design of valves of infiltration are designated. Technical solutions aimed at improving the quality of indoor microclimate and energy saving are proposed.


Sign in / Sign up

Export Citation Format

Share Document