Characterization of the Mixing Performance of an Innovative Hepatic Sinusoids-Based Microreactor Using Villermaux-Dushman Protocol

2020 ◽  
Vol 1008 ◽  
pp. 28-32
Author(s):  
Mahmoud Abdelghany Shouman ◽  
Ahmed Hassan El-Shazly ◽  
Marwa Farouk El-Kady ◽  
Mohamed Nabil Sabry

Microreactor technology has drawn attention in many industrial applications, especially those that requires the use of low flow rates whereas the flow is considered to be stratified. At such low flow rates, the reactor performance is usually down especially if mass transfer occurs mainly by diffusion. In the present work, the mixing performance of a novel hepatic sinusoids-based microreactor has been investigated using Villermaux–Dushman protocol. The protocol is an iodide/iodate chemical test reaction that relies on testing the absorbance of the product at 352 nm as an indication of the formation of triiodide. The investigation is carried out at low flow rates ranges from 0.5 to 3 ml/min. The novel microreactor has proven to give satisfactory performance and is easy to be fabricated as it consists of a single layer. The absorbance of light ranges between 0.29 to 0.48 resulting on the creation of limited amount of triiodide ions. It is also noticed that the mixing performance of the reactor is nearly the same over the whole studied range of flow rate. The mixing quality is also determined using another system containing 200 ppm congo red aqueous solution and pure distilled water. About 94% to 96% mixing quality is achieved.

2021 ◽  
Vol 321 ◽  
pp. 02011
Author(s):  
Van-Thang Nguyen ◽  
Amelie Danlos ◽  
Florent Ravelet ◽  
Michael Deligant ◽  
Moises Solis ◽  
...  

Centrifugal compressors are widely used in many industrial applications because of their advantages. However, these turbomachines suffer at a low-flow rate from instabilities, such as rotating stall and surge. That leads to operational failure, pressure fluctuations and vibrations of the thorough system. Many mechanical solutions minimize these instabilities and expand the operating range towards low-flow rates like active control of the flow path, variable inlet guide vane and casing treatment. Currently, our team has developed a new compressor composed of a twin-impeller powered by autonomous systems. We notice the performance improvement and instabilities suppression of this compressor experimentally. In this paper, a CFD study is presented to explain some of these experimental observations by analyzing the inside of twin-impeller, the flow structures and thermodynamic characteristics at low flow rates operating in a co-rotating mode. Numerical results and experimental measurements of compressor maps are consistent.


2014 ◽  
Vol 699 ◽  
pp. 429-434
Author(s):  
Dominicus Danardono ◽  
Ki Seong Kim

A coaxial gas mixer is designed for mixing air and synthesis gas or syngas as fuel. Three-dimensional computational models are harnessed to analyze and predict the influence of the mechanical tabs aspect ratio and number on the mixing characteristics and performance of the gas mixer. Attention is concentrated on the influence of mechanical tabs on the air-fuel ratio, pressure loss and mixing quality. The optimum design of the mechanical tab was realized with aspect ratio of 0.32 and 4 tabs with 45o tab angle. The coaxial gas mixer using the optimized mechanical tabs was realized with λ of 1.13 corresponding to pressure loss of 37.2 Pa at 100 m3/h air-flow rates and the coefficient of variation (CoV) of mixing was 0.29. The gas mixer with the mechanical tabs had much better mixing performance than the gas mixer without mechanical tabs with only relatively small increase in pressure loss.


ORL ◽  
2021 ◽  
pp. 1-5
Author(s):  
Jingjing Liu ◽  
Tengfang Chen ◽  
Zhenggang Lv ◽  
Dezhong Wu

<b><i>Introduction:</i></b> In China, nasal cannula oxygen therapy is typically humidified. However, it is difficult to decide whether to suspend nasal cannula oxygen inhalation after the nosebleed has temporarily stopped. Therefore, we conducted a preliminary investigation on whether the use of humidified nasal cannulas in our hospital increases the incidence of epistaxis. <b><i>Methods:</i></b> We conducted a survey of 176,058 inpatients in our hospital and other city branches of our hospital over the past 3 years and obtained information concerning their use of humidified nasal cannulas for oxygen inhalation, nonhumidified nasal cannulas, anticoagulant and antiplatelet drugs, and oxygen inhalation flow rates. This information was compared with the data collected at consultation for epistaxis during these 3 years. <b><i>Results:</i></b> No significant difference was found between inpatients with humidified nasal cannulas and those without nasal cannula oxygen therapy in the incidence of consultations due to epistaxis (χ<sup>2</sup> = 1.007, <i>p</i> &#x3e; 0.05). The same trend was observed among hospitalized patients using anticoagulant and antiplatelet drugs (χ<sup>2</sup> = 2.082, <i>p</i> &#x3e; 0.05). Among the patients with an inhaled oxygen flow rate ≥5 L/min, the incidence of ear-nose-throat (ENT) consultations due to epistaxis was 0. No statistically significant difference was found between inpatients with a humidified oxygen inhalation flow rate &#x3c;5 L/min and those without nasal cannula oxygen therapy in the incidence of ENT consultations due to epistaxis (χ<sup>2</sup> = 0.838, <i>p</i> &#x3e; 0.05). A statistically significant difference was observed in the incidence of ENT consultations due to epistaxis between the low-flow nonhumidified nasal cannula and nonnasal cannula oxygen inhalation groups (χ<sup>2</sup> = 18.428, <i>p</i> &#x3c; 0.001). The same trend was observed between the 2 groups of low-flow humidified and low-flow nonhumidified nasal cannula oxygen inhalation (χ<sup>2</sup> = 26.194, <i>p</i> &#x3c; 0.001). <b><i>Discussion/Conclusion:</i></b> Neither high-flow humidified nasal cannula oxygen inhalation nor low-flow humidified nasal cannula oxygen inhalation will increase the incidence of recurrent or serious epistaxis complications; the same trend was observed for patients who use anticoagulant and antiplatelet drugs. Humidification during low-flow nasal cannula oxygen inhalation can prevent severe and repeated epistaxis to a certain extent.


Author(s):  
Yo Han Jung ◽  
Young Uk Min ◽  
Jin Young Kim

This paper presents a numerical investigation of the effect of tip clearance on the suction performance and flow characteristics at different flow rates in a vertical mixed-flow pump. Numerical analyses were carried out by solving three-dimensional Reynolds-averaged Navier-Stokes equations. Steady computations were performed for three different tip clearances under noncavitating and cavitating conditions at design and off-design conditions. The pump performance test was performed for the mixed-flow pump and numerical results were validated by comparing the experimental data for a system characterized by the original tip clearance. It was shown that for large tip clearance, the head breakdown occurred earlier at the design and high flow rates. However, the head breakdown was quite delayed at low flow rate. This resulted from the cavitation structure caused by the tip leakage flow at different flow rates.


2019 ◽  
Vol 36 (4) ◽  
pp. 401-410 ◽  
Author(s):  
Xiao-Qi Jia ◽  
Bao-Ling Cui ◽  
Zu-Chao Zhu ◽  
Yu-Liang Zhang

Abstract Affected by rotor–stator interaction and unstable inner flow, asymmetric pressure distributions and pressure fluctuations cannot be avoided in centrifugal pumps. To study the pressure distributions on volute and front casing walls, dynamic pressure tests are carried out on a centrifugal pump. Frequency spectrum analysis of pressure fluctuation is presented based on Fast Fourier transform and steady pressure distribution is obtained based on time-average method. The results show that amplitudes of pressure fluctuation and blade-passing frequency are sensitive to the flow rate. At low flow rates, high-pressure region and large pressure gradients near the volute tongue are observed, and the main factors contributing to the pressure fluctuation are fluctuations in blade-passing frequency and high-frequency fluctuations. By contrast, at high flow rates, fluctuations of rotating-frequency and low frequencies are the main contributors to pressure fluctuation. Moreover, at low flow rates, pressure near volute tongue increases rapidly at first and thereafter increases slowly, whereas at high flow rates, pressure decreases sharply. Asymmetries are observed in the pressure distributions on both volute and front casing walls. With increasing of flow rate, both asymmetries in the pressure distributions and magnitude of the pressure decrease.


2021 ◽  
pp. 1-54
Author(s):  
Subhra Shankha Koley ◽  
Huang Chen ◽  
Ayush Saraswat ◽  
Joseph Katz

Abstract This experimental study characterizes the interactions of axial casing grooves with the flow in the tip region of an axial turbomachine. The tests involve grooves with the same inlet overlapping with the rotor blade leading edge, but with different exit directions located upstream. Among them, U grooves, whose circumferential outflow opposes the blade motion, achieve a 60% reduction in stall flowrate, but degrade the efficiency around the best efficiency point (BEP) by 2%. The S grooves, whose outlets are parallel to the blade rotation, improve the stall flowrate by only 36%, but do not degrade the BEP performance. To elucidate the mechanisms involved, stereo-PIV measurements covering the tip region and interior of grooves are performed in a refractive index matched facility. At low flow rates, the inflow into both grooves, which peaks when they are aligned with the blade pressure side, rolls up into a large vortex that lingers within the groove. By design, the outflow from S grooves is circumferentially positive. For the U grooves, fast circumferentially negative outflow peaks at the base of each groove, causing substantial periodic variations in the flow angle near the blade leading edge. At BEP, interactions with both grooves become milder, and most of the tip leakage vortex remains in the passage. Interactions with the S grooves are limited hence they do not degrade the efficiency. In contrast, the inflow into and outflow from the U grooves reverses direction, causing entrainment of secondary flows, which likely contribute to the reduced BEP efficiency.


Author(s):  
Shyam P. Tekade ◽  
Diwakar Z. Shende ◽  
Kailas L. Wasewar

Abstract Hydrogen is one of the important non-conventional energy sources because of its high energy content and non-polluting nature of combustions. The water splitting reaction is one of the significant methods for hydrogen generation from non-fossil feeds. In the present paper, the hydrogen generation has been experimentally investigated with water splitting reaction using metal aluminum in presence of potassium hydroxide as an activator under flow conditions. The rate of hydrogen generation was reported in the annular micro- reactor of 1 mm annulus using various flow rates of aqueous 0.5 N KOH ranging from 1 ml/min to 10 ml/min. The complete conversion of aluminum was observed at all the flow rates of aqueous KOH. The hydrogen generation rate was observed to depend on the flow rate of liquid reactant flowing through the reactor. At 1 ml/min of 0.5 N KOH, hydrogen generates at an average rate of 3.36 ml/min which increases to 10.70 ml/min at 10 ml/min of aqueous KOH. The Shrinking Core Model was modified for predicting the controlling mechanism. The rate of hydrogen generation was observed to follow different controlling mechanisms on various time intervals at low flow rates of aqueous KOH. It was observed that chemical reaction controls the overall rate of hydrogen generation at higher flow rates of aqueous KOH.


1983 ◽  
Vol 26 ◽  
Author(s):  
Aaron Barkatt ◽  
William Sousanpour ◽  
Alisa Barkatt ◽  
Morad A. Boroomand ◽  
Pedro B. Macedo

ABSTRACTLeach tests carried out on SRL TDS-131 Defense Waste Class indicate that at high flow rates the controlling mechanism is simple corrosion. The matrix elements (Si, Al) are leached out at rates similar to those of the leaching of the alkalis and of boron, and the leaching process is nearly linear with time. At slow flow rates (below 1 m/yr) leaching becomes controlled by the build-up of a protective layer. Al and most of the Si remain in the leached surface layer. The leach rates decrease in the course of the test before leveling off at constant values which are almost inversely proportional to the contact time, indicating that leachate concentrations have become solubility-limited. The low concentrations observed at this stage indicate the formation of alteration products.


Micromachines ◽  
2020 ◽  
Vol 11 (4) ◽  
pp. 349 ◽  
Author(s):  
Erik S. Hamilton ◽  
Vahid Ganjalizadeh ◽  
Joel G. Wright ◽  
Holger Schmidt ◽  
Aaron R. Hawkins

Optofluidic devices are capable of detecting single molecules, but greater sensitivity and specificity is desired through hydrodynamic focusing (HDF). Three-dimensional (3D) hydrodynamic focusing was implemented in 10-μm scale microchannel cross-sections made with a single sacrificial layer. HDF is achieved using buffer fluid to sheath the sample fluid, requiring four fluid ports to operate by pressure driven flow. A low-pressure chamber, or pit, formed by etching into a substrate, enables volumetric flow ratio-induced focusing at a low flow velocity. The single layer design simplifies surface micromachining and improves device yield by 1.56 times over previous work. The focusing design was integrated with optical waveguides and used in order to analyze fluorescent signals from beads in fluid flow. The implementation of the focusing scheme was found to narrow the distribution of bead velocity and fluorescent signal, giving rise to 33% more consistent signal. Reservoir effects were observed at low operational vacuum pressures and a balance between optofluidic signal variance and intensity was achieved. The implementation of the design in optofluidic sensors will enable higher detection sensitivity and sample specificity.


Sign in / Sign up

Export Citation Format

Share Document