Research on the Properties of Nano Core-Shell Ni/TiO2/Urea EMR Fluid

2011 ◽  
Vol 687 ◽  
pp. 519-522
Author(s):  
Suo Kui Tan ◽  
Xiao Ping Song ◽  
Qiao Li ◽  
Hong Yan Guo ◽  
Song Ji ◽  
...  

In the present paper, mechanical properties test and morphology observation,the effect among electric field, magnetic field and electromagnetic field, shear ratio on the Ni/TiO2/Urea core-shell particles electrorheological fluid properties were studied. It is found that with increasing electric field, magnetic field and shear ratio in the same composition electrorheological fluid, the property of electrorheological fluid can be increased. However, there is a critical value for shear ratio. When shear ratio is larger than 20s-1, the property of ER is nearly certain value for same composition ER fluid. Electromagnetic field reciprocal effect can increase the properties of ER fluid, and make the particles chain become thicker and interweaved each other.

2011 ◽  
Vol 211-212 ◽  
pp. 775-779 ◽  
Author(s):  
Suo Kui Tan ◽  
Xiao Ping Song ◽  
Qiao Li ◽  
Hong Yan Guo ◽  
Song Ji ◽  
...  

By means of mechanical properties test, the relationship among particle size,electric field,magnetic field ,electromagnetic field and shear ratio on the Ni/TiO2/Urea core-shell particles electrorheological fluid properties analyses. It is found that with increasing particle size, the property of electrorheological fluid decreased, and with increasing shear ratio the property of electrorheological fluid increased for same composition ER. At same time, the smaller of particle size, the higher of ER properties, but there is a critical value for shear ratio, the properties of ER is near value for same composition ER fluid. In magnetic field, the properties of ER showed a contrary result, the smaller of particle size, the lower of ER properties,and electromagnetic field make the properties increase.


2011 ◽  
Vol 214 ◽  
pp. 312-315
Author(s):  
Suo Kui Tan ◽  
Xiao Ping Song ◽  
Li Qiao ◽  
Hong Yan Guo ◽  
Song Ji ◽  
...  

By means of mechanical properties test,the relationship among shear ratio, concentration and electric field, magnetic field ,electromagnetic field on the Ni/TiO2 group electrorheological fluid properties have been analyzed. It is found that with increasing shear ratio,the property of electrorheological fluid increased for same composition ER, but there is a critical value. With increasing concentration,the property of electrorheological fluid increased for same shear ratio. Coupling electromagnetic field makes the properties improve.


2012 ◽  
Vol 512-515 ◽  
pp. 2166-2170
Author(s):  
Suo Kui Tan ◽  
Xiao Ping Song ◽  
Hong Zhao ◽  
Song Ji ◽  
Li Qiao ◽  
...  

By means of mechanical properties test and structure observation, the relationship among electric field strength, polar molecule type, content on the Ni/TiO2group electrorheological fluid properties have been analyzed. It is found that with increasing electric field strength,the properties of electrorheological fluid increased for same composition ER fluid. Different type polar molecules have distinct effect. For same particle,with increasing polar molecule content,the property is increased, but there is a critical value . Polar molecule make particles chain of electrorheological fluid become strong,coarse and interweaved each other.


2013 ◽  
Vol 706-708 ◽  
pp. 254-257 ◽  
Author(s):  
Suo Kui Tan ◽  
Xiao Ping Song ◽  
Hong Zhao ◽  
Song Ji ◽  
Min Wu ◽  
...  

By means of mechanical properties test,the relationship among shear ratio, concentration and electric field, magnetic field, electromagnetic field on the Ni/TiO2/SDBS EMR fluid properties have been analyzed. It had found that with increasing shear ratio,the shear stress of Ni/TiO2/SDBS EMR fluid increased for same composition, but there is a critical value. With increasing concentration,the property of EMR fluid increased for same shear ratio. Coupling electromagnetic field makes the properties improve.


2011 ◽  
Vol 335-336 ◽  
pp. 18-22
Author(s):  
Suo Kui Tan ◽  
Xiao Ping Song ◽  
Li Qiao ◽  
Hong Yan Guo ◽  
Song Ji ◽  
...  

By means of structure analysis, mechanical properties test and microstructure observation,structure of Ni and Ni/TiO2group particles have been obtained, the relationship among particSubscript textSubscript textle diameter,electric field strength and shear ratio of the properties of Ni/TiO2group core-shell particles ER fluid have been researched. It has been found that with increasing particle diameter,the shear stress of ER fluid decreased, and with increasing shear ratio,the shear stress of ER fluid increased for same diameter particle and composition ER fluid. At same time, the smaller of particle diameter, the higher of ER properties such as shear stress, but there is a critical value for shear ratio, when shear ratio is larger than critical value, the properties of ER is nearly a value for same composition ER fluid. Particles chain of ER fluid under certain electric field is different with diversity Ni group Particles.


2012 ◽  
Vol 476-478 ◽  
pp. 1749-1752
Author(s):  
Suo Kui Tan ◽  
Xiao Ping Song ◽  
Song Ji ◽  
Hong Zhao ◽  
Min Wu ◽  
...  

This paper emphasis has researched the ER properties of Ni group core-shell nano particles modifier with Urea,SDBS and other polar molecule,analysis the relationship among ER properties and polar molecule type ,compound modifier under different electric field or magnetic field. It is found that the shear stress increasing with adding polar molecule, compound polar molecule modify can marked advance the properties of Ni group core-shell particles ER fluid.


2012 ◽  
Vol 510 ◽  
pp. 594-598
Author(s):  
Suo Kui Tan ◽  
Xiao Ping Song ◽  
Li Qiao ◽  
Hong Yan Guo ◽  
Song Ji ◽  
...  

By means of mechanical properties test and microstructure observation,the relationship between mechanical properties ,microstructure graph of core-shell Ni/TiO2group particles concentration of EMR and different electric field, magnetic field or electric-magnetic field have been researched. It is found that with increasing of particles concentration, the properties are increased. But there is a critical range value, too high or too low particles concentrations are harmful to properties and microstructure. The best particles concentration of Ni/TiO2particles is about 30%. In the same field with increasing concentration, particles chain of electrorheological fluid under certain electric field become more strong,brawnier and interweaved each other.


2019 ◽  
Vol 50 (3) ◽  
pp. 333-345 ◽  
Author(s):  
Danmei Sun ◽  
Meixuan Chen ◽  
Symon Podilchak ◽  
Apostolos Georgiadis ◽  
Qassim S Abdullahi ◽  
...  

Smart and interactive textiles have been attracted great attention in recent years. This research explored three different techniques and processes in developing textile-based conductive coils that are able to embed in a garment layer. Coils made through embroidery and screen printing have good dimensional stability, although the resistance of screen printed coil is too high due to the low conductivity of the print ink. Laser cut coil provided the best electrical conductivity; however, the disadvantage of this method is that it is very difficult to keep the completed coil to the predetermined shape and dimension. The tested results show that an electromagnetic field has been generated between the textile-based conductive coil and an external coil that is directly powered by electricity. The magnetic field and electric field worked simultaneously to complete the wireless charging process.


Author(s):  
Lei Tian ◽  
Limei Song ◽  
Yu Zheng ◽  
Jinhai Wang

Multi-coil magnetic stimulation has advantages over single-coil magnetic stimulation, such as more accurate targeting and larger stimulation range. In this paper, a 4 × 4 array multichannel magnetic stimulation system based on a submillimeter planar square spiral coil is proposed. The effects of multiple currents with different directions on the electromagnetic field strength and the focusing zone of the array-structured magnetic stimulation system are studied. The spatial distribution characteristics of the electromagnetic field are discussed. In addition, a method is proposed that can predict the spatial distributions of the electric and magnetic fields when currents in different directions are applied to the array-structured magnetic stimulation system. The study results show that in the section of z = 2 μm, the maximum and average magnetic field strengths of the array-structured magnetic stimulation system are 6.39 mT and 2.68 mT, respectively. The maximum and average electric field strengths are 614.7 mV/m and 122.82 mV/m, respectively, where 84.39% of the measured electric field values are greater than 73 mV/m. The average magnetic field strength of the focusing zone, i.e., the zone in between the two coils, is 3.38 mT with a mean square deviation of 0.18. Therefore, the array-structured multi-channel magnetic stimulation system based on a planar square spiral coil can have a small size of 412 μm × 412 μm × 1.7 μm, which helps improving the spatial distribution of electromagnetic field and increase the effectiveness of magnetic stimulation. The main contribution of this paper is a method for designing multichannel micro-magnetic stimulation devices.


1972 ◽  
Vol 51 (3) ◽  
pp. 585-591 ◽  
Author(s):  
C. Sozou

The deformation of a liquid drop immersed in a conducting fluid by the imposition of a uniform electric field is investigated. The flow field set up is due to the surface charge and the tangential electric field stress over the surface of the drop, and the rotationality of the Lorentz force which is set up by the electric current and the associated magnetic field. It is shown that when the fluids are poor conductors and good dielectrics the effects of the Lorentz force are minimal and the flow field is due to the stresses of the electric field tangential to the surface of the drop, in agreement with other authors. When, however, the fluids are highly conducting and poor dielectrics the effects of the Lorentz force may be predominant, especially for larger drops.


Sign in / Sign up

Export Citation Format

Share Document