scholarly journals Muscle activation in specific regions of the trapezius during modified Kendall manual muscle tests

2021 ◽  
Author(s):  
Zachariah J. Henderson ◽  
Sarah Bohunicky ◽  
Josee A. Rochon ◽  
Mark Dacanay ◽  
Trisha D. Scribbans

Abstract Context: Manual muscle tests (MMTs) are often used when assessing shoulder pathologies. For the trapezius, individual MMTs are used to selectively test the upper (UTR), middle (MTR), and lower (LTR) trapezius regions. It is assumed that MMTs for each region preferentially recruit the corresponding muscle fibres and produce a “maximal” contraction; however, it is unknown if this is true. Objective: To determine if maximum voluntary isometric contractions (MVICs) for the upper (UT-MVIC), middle (MT-MVIC), and lower (LT-MVIC) trapezius, adapted from the Kendall MMTs, recruit the corresponding trapezius regions. Design: Cross-Over. Setting: Laboratory. Participants: 20 young, healthy individuals. Intervention: Participants performed three repetitions of each MVIC. High density surface electromyography was collected from the UTR, MTR, and LTR. Main Outcome Measures: Root mean square (excitation) of the UTR, MTR, and LTR. Statistical Analysis: Three, one-way repeated measures ANOVAs. Results: UTR excitation: There was a significant increase in UTR excitation during the LT-MVIC compared to the UT-MVIC (p = .016), and MT-MVIC (p < .001). MTR excitation: There was a significant increase in MTR excitation during the MT-MVIC compared to the UT-MVIC (p = .001), and a significant increase in MTR excitation during the LT-MVIC compared to the UT-MVIC (p < .001). There was also a significant increase in MTR excitation during the LT-MVIC compared to the MT-MVIC (p < .001). LTR excitation: There was a significant increase in LTR excitation during the MT-MVIC (p < .001) and LT-MVIC (p < .001) compared to the UT-MVIC. Conclusions: The UT-MVIC and MT-MVIC do not necessarily recruit the corresponding trapezius regions more than the other MVICs. Rather, the LT-MVIC appears to produce the greatest excitation in all trapezius regions. Additional research is needed; however, clinicians should be aware that maximal contractions may not always recruit the desired musculature when forming a clinical interpretation.

Proceedings ◽  
2020 ◽  
Vol 49 (1) ◽  
pp. 71
Author(s):  
Patricio A. Pincheira ◽  
Eduardo Martinez-Valdes ◽  
Carlos De la Fuente ◽  
Felipe Palma ◽  
Oscar Valencia ◽  
...  

Regional changes in muscle activation occur at different contraction intensities. These changes can be observed with activity maps created with high-density electromyography (HDEMG). When quantifying these changes, statistical parametric mapping (SPM) is a neuroimaging technique that may be used to perform statistical analyses with high sensitivity and spatial resolution. The aim of this study was to identify regional changes in muscle activation at different contraction intensities, comparing SPM and the HDEMG barycenter (centroid). Twelve participants performed plantar flexion isometric contractions at 20%, 40%, and 60% of the maximal voluntary contraction (MVC), while HDEMG was recorded from the medial gastrocnemius. An SPM repeated measures ANOVA design revealed specific mediolateral and cephalocaudal changes in muscle activation with increasing contraction intensities, which were not clearly detected by the variation in the barycenter coordinates. Only SPM revealed statistically significant nonuniform changes in EMG amplitude between all increasing levels of muscle activation.


2019 ◽  
Vol 34 (4) ◽  
pp. 205-214 ◽  
Author(s):  
Alessandro Russo ◽  
Alejandra Aranceta-Garza ◽  
Samuel D’Emanuele ◽  
Francesca Serafino ◽  
Roberto Merletti

This study compared an ergonomic alternative chair (A-chair) with a standard orchestra chair (O-chair) used by a group of 9 violin players. The features of the high-density surface EMG (HDsEMG) of the lumbar erector spinae muscles were used for the comparison. The violinists played the same pieces of music for 2 hrs without interruption on each chair in 2 different days, 1 week apart. HDsEMG was recorded for 20 s every 5 minutes using two electrode arrays of 16 × 8 electrodes each, one on each side of the spine and placed between the T11 and L4 levels. The sEMG was non-stationary and burst-like patterns were observed on 8 out of 9 violinists. The mean root mean square (RMS) and mean spectral frequency (MNF) value over the region of activity (ROA), the centroid of the ROA, the rates of change in time of the spatial mean of the RMS and MNF values, and the burst frequencies associated with the two chairs were compared. Statistically significant reductions of RMS were observed in each violinist between the O-chair and A-chair (range 11.80−78.36%). No significant changes of other spatial or spectral sEMG features were globally observed versus time or between chairs but were demonstrated by some subjects. It is concluded that the A-chair is associated with a decrease of the sEMG amplitude of the ESM without changes of the spatial and temporal patterns of muscle activation.


2011 ◽  
Vol 20 (2) ◽  
pp. 174-186 ◽  
Author(s):  
Catriona O’Dwyer ◽  
David Sainsbury ◽  
Kieran O’Sullivan

Context:Functional subdivisions are proposed to exist in the gluteus medius (GM) muscle. Dysfunction of the GM, in particular its functional subdivisions, is commonly implicated in lower limb pathologies. However, there is a lack of empirical evidence examining the role of the subdivisions of the GM.Objectives:To compare the activation of the functional subdivisions of the GM (anterior, middle, and posterior) during isometric hip contractions.Design:Single-session, repeated-measures observational study.Setting:University research laboratory.Participants:Convenience sample of 15 healthy, pain-free subjects.Intervention:Subjects performed 3 maximal voluntary isometric contractions for hip abduction and internal and external rotation on an isokinetic dynamometer with simultaneous recording of surface electromyography (sEMG) activity of the GM subdivisions.Main Outcome Measures:sEMG muscle activity for each functional subdivision of the GM during each hip movement was analyzed using a 1-way repeated-measures ANOVA (post hoc Bonferroni).Results:The response of GM subdivisions during the 3 different isometric contractions was significantly different (interaction effect; P = .003). The anterior GM displayed significantly higher activation across all 3 isometric contractions than the middle and posterior subdivisions (main effect; both P < .001). The middle GM also demonstrated significantly higher activation than the posterior GM across all 3 isometric contractions (main effect; P = .027). There was also significantly higher activation of all 3 subdivisions during both abduction and internal rotation than during external rotation (main effect; both P < .001).Conclusions:The existence of functional subdivisions in the GM appears to be supported by the findings. Muscle activation was not homogeneous throughout the entire muscle. The highest GM activation was found in the anterior GM subdivision and during abduction and internal rotation. Future studies should examine the role of GM functional subdivisions in subjects with lower limb pathologies.


2005 ◽  
Vol 99 (3) ◽  
pp. 1056-1063 ◽  
Author(s):  
B.M. Meyers ◽  
E. Cafarelli

Caffeine increases time to fatigue [limit of endurance (Tlim)] during submaximal isometric contractions without altering whole muscle activation or neuromuscular junction transmission. We used 10 male volunteers in a randomized, double-blind, repeated-measures experiment to examine single motor unit firing rates during intermittent submaximal contractions and to determine whether administering caffeine increased Tlim by maintaining higher firing rates. On 2 separate days, subjects performed intermittent 50% maximal voluntary contractions of the quadriceps to Tlim, 1 h after ingesting a caffeine (6 mg/kg) or placebo capsule. Average motor unit firing rates recorded with tungsten microelectrodes were constant for the duration of contractions. Caffeine increased average Tlim by 20.5 ± 8.1% ( P < 0.05) compared with placebo conditions. This increase was due to seven subjects, termed responders, who increased Tlim significantly. Two other subjects showed no response, and a third had a shorter Tlim. Neither the increased Tlim nor the responders' performance could be explained by alterations in firing rates or other neuromuscular variables. However, the amplitude of the evoked twitch and its maximal instantaneous rate of relaxation did not decline to the same degree in the caffeine trial of the responders; this resulted in values 20 and 30% higher at the time point matching the end of the placebo trial ( P < 0.05). The amplitude of the evoked twitch and the maximal instantaneous rate of relaxation were linearly correlated (caffeine r = 0.72, placebo r = 0.80, both P < 0.001), suggesting that the increase in Tlim may be partially explained by caffeine's effects on calcium reuptake and twitch force.


Symmetry ◽  
2021 ◽  
Vol 13 (4) ◽  
pp. 717
Author(s):  
Mariia Nazarkevych ◽  
Natalia Kryvinska ◽  
Yaroslav Voznyi

This article presents a new method of image filtering based on a new kind of image processing transformation, particularly the wavelet-Ateb–Gabor transformation, that is a wider basis for Gabor functions. Ateb functions are symmetric functions. The developed type of filtering makes it possible to perform image transformation and to obtain better biometric image recognition results than traditional filters allow. These results are possible due to the construction of various forms and sizes of the curves of the developed functions. Further, the wavelet transformation of Gabor filtering is investigated, and the time spent by the system on the operation is substantiated. The filtration is based on the images taken from NIST Special Database 302, that is publicly available. The reliability of the proposed method of wavelet-Ateb–Gabor filtering is proved by calculating and comparing the values of peak signal-to-noise ratio (PSNR) and mean square error (MSE) between two biometric images, one of which is filtered by the developed filtration method, and the other by the Gabor filter. The time characteristics of this filtering process are studied as well.


Sensors ◽  
2021 ◽  
Vol 21 (10) ◽  
pp. 3311
Author(s):  
Riccardo Ballarini ◽  
Marco Ghislieri ◽  
Marco Knaflitz ◽  
Valentina Agostini

In motor control studies, the 90% thresholding of variance accounted for (VAF) is the classical way of selecting the number of muscle synergies expressed during a motor task. However, the adoption of an arbitrary cut-off has evident drawbacks. The aim of this work is to describe and validate an algorithm for choosing the optimal number of muscle synergies (ChoOSyn), which can overcome the limitations of VAF-based methods. The proposed algorithm is built considering the following principles: (1) muscle synergies should be highly consistent during the various motor task epochs (i.e., remaining stable in time), (2) muscle synergies should constitute a base with low intra-level similarity (i.e., to obtain information-rich synergies, avoiding redundancy). The algorithm performances were evaluated against traditional approaches (threshold-VAF at 90% and 95%, elbow-VAF and plateau-VAF), using both a simulated dataset and a real dataset of 20 subjects. The performance evaluation was carried out by analyzing muscle synergies extracted from surface electromyographic (sEMG) signals collected during walking tasks lasting 5 min. On the simulated dataset, ChoOSyn showed comparable performances compared to VAF-based methods, while, in the real dataset, it clearly outperformed the other methods, in terms of the fraction of correct classifications, mean error (ME), and root mean square error (RMSE). The proposed approach may be beneficial to standardize the selection of the number of muscle synergies between different research laboratories, independent of arbitrary thresholds.


1995 ◽  
Vol 74 (6) ◽  
pp. 2665-2684 ◽  
Author(s):  
Y. Kondoh ◽  
Y. Hasegawa ◽  
J. Okuma ◽  
F. Takahashi

1. A computational model accounting for motion detection in the fly was examined by comparing responses in motion-sensitive horizontal system (HS) and centrifugal horizontal (CH) cells in the fly's lobula plate with a computer simulation implemented on a motion detector of the correlation type, the Reichardt detector. First-order (linear) and second-order (quadratic nonlinear) Wiener kernels from intracellularly recorded responses to moving patterns were computed by cross correlating with the time-dependent position of the stimulus, and were used to characterize response to motion in those cells. 2. When the fly was stimulated with moving vertical stripes with a spatial wavelength of 5-40 degrees, the HS and CH cells showed basically a biphasic first-order kernel, having an initial depolarization that was followed by hyperpolarization. The linear model matched well with the actual response, with a mean square error of 27% at best, indicating that the linear component comprises a major part of responses in these cells. The second-order nonlinearity was insignificant. When stimulated at a spatial wavelength of 2.5 degrees, the first-order kernel showed a significant decrease in amplitude, and was initially hyperpolarized; the second-order kernel was, on the other hand, well defined, having two hyperpolarizing valleys on the diagonal with two off-diagonal peaks. 3. The blockage of inhibitory interactions in the visual system by application of 10-4 M picrotoxin, however, evoked a nonlinear response that could be decomposed into the sum of the first-order (linear) and second-order (quadratic nonlinear) terms with a mean square error of 30-50%. The first-order term, comprising 10-20% of the picrotoxin-evoked response, is characterized by a differentiating first-order kernel. It thus codes the velocity of motion. The second-order term, comprising 30-40% of the response, is defined by a second-order kernel with two depolarizing peaks on the diagonal and two off-diagonal hyperpolarizing valleys, suggesting that the nonlinear component represents the power of motion. 4. Responses in the Reichardt detector, consisting of two mirror-image subunits with spatiotemporal low-pass filters followed by a multiplication stage, were computer simulated and then analyzed by the Wiener kernel method. The simulated responses were linearly related to the pattern velocity (with a mean square error of 13% for the linear model) and matched well with the observed responses in the HS and CH cells. After the multiplication stage, the linear component comprised 15-25% and the quadratic nonlinear component comprised 60-70% of the simulated response, which was similar to the picrotoxin-induced response in the HS cells. The quadratic nonlinear components were balanced between the right and left sides, and could be eliminated completely by their contralateral counterpart via a subtraction process. On the other hand, the linear component on one side was the mirror image of that on the other side, as expected from the kernel configurations. 5. These results suggest that responses to motion in the HS and CH cells depend on the multiplication process in which both the velocity and power components of motion are computed, and that a putative subtraction process selectively eliminates the nonlinear components but amplifies the linear component. The nonlinear component is directionally insensitive because of its quadratic non-linearity. Therefore the subtraction process allows the subsequent cells integrating motion (such as the HS cells) to tune the direction of motion more sharply.


Biomechanics ◽  
2021 ◽  
Vol 1 (2) ◽  
pp. 202-213
Author(s):  
Harish Chander ◽  
Sachini N. K. Kodithuwakku Arachchige ◽  
Alana J. Turner ◽  
Reuben F. Burch V ◽  
Adam C. Knight ◽  
...  

Background: Occupational footwear and a prolonged duration of walking have been previously reported to play a role in maintaining postural stability. The purpose of this paper was to analyze the impact of three types of occupational footwear: the steel-toed work boot (ST), the tactical work boot (TB), and the low-top work shoe (LT) on previously unreported lower extremity muscle activity during postural stability tasks. Methods: Electromyography (EMG) muscle activity was measured from four lower extremity muscles (vastus medialis (VM), medial hamstrings (MH), tibialis anterior (TA), and medial gastrocnemius (MG) during maximal voluntary isometric contractions (MVIC) and during a sensory organization test (SOT) every 30 min over a 4 h simulated workload while wearing ST, TB, and LT footwear. The mean MVIC and the mean and percentage MVIC during each SOT condition from each muscle was analyzed individually using a repeated measures ANOVA at an alpha level of 0.05. Results: Significant differences (p < 0.05) were found for maximal exertions, but this was limited to only the time main effect. No significant differences existed for EMG measures during the SOT. Conclusion: The findings suggest that occupational footwear type does not influence lower extremity muscle activity during both MVIC and SOT. Significantly lower muscle activity during maximal exertions over the course of the 4 h workload was evident, which can be attributed to localized muscular fatigue, but this was not sufficient to impact muscle activity during postural stability tasks.


It was shown in an earlier paper (7) that if maximal stimulation of either of two different afferent nerves can reflexly excite fractions of a given flexor muscle, there are generally, within the aggregate of neurones which innervate that muscle, motoneurones which can be caused to discharge by either afferent (i. e., motoneurones common to both fractions). The relationship which two such afferents bear to a common motoneurone was shown, by the isometric method of recording contraction, to be such that the activation of one afferent, at a speed sufficient to cause a maximal motor tetanus when trans­mitted to the muscle fibres, caused exclusion of any added mechanical effect when the other afferent was excited concurrently. This default in mechanical effect was called “occlusion.” Occlusion may conceivably be due to total exclusion of the effect of one afferent pathway on the common motoneurone by the activity of the other; but facilitation of the effect of one path by the activation of the other when the stimuli were minimal suggests that, in some circumstances at least, the effect of each could augment and summate with th at of the other at the place of convergence of two afferent pathways. Further investigation, using the action currents of the muscle as indication of the nerve impulses discharged by the motoneurone units, has now given some information regarding the effect of impulses arriving at the locus of convergence by one afferent path when the unit common to both is already discharging in response to impulses arriving by the other afferent path. Our method has been to excite both afferent nerves in overlapping sequence by series of break shocks at a rapid rate and to examine the action currents of the resulting reflex for evidence of the appearance of the rhythm of the second series in the discharge caused by the first when the two series are both reaching the motoneurone.


2012 ◽  
Vol 602-604 ◽  
pp. 776-780
Author(s):  
Zhi Qiang Li ◽  
Mei Li ◽  
Wei Jia Fan

Poly(3-hydroxybutyrate-co-4-hydroxybutyrate)copolymer [P(3HB-co-4HB)] is a kind of biodegradable high molecular polymer produced by bioaccumulation. Because of the good biodegradability and biocompatibility, P(3HB-co-4HB)s have attracted wide attention . At first, the intrinsic viscosity[η] in good solvent of P(3HB-co-4HB) s with varying contents of 4HB was investigated in different temperature. Second, observed the changes of crystallization gathered state caused by the varying contents of 4HB by polarizing microscope. The results show that to the P(3HB-co-4HB)s in same molecular weight, the intrinsic viscosity[η] in good solvent barely changes when the mole fractions of 4HB increase. On the other hand, the mean square end to end distances[0] of macromolecular flexible chains increase with the mole fractions of 4HB. At the same time, the states of aggregation change from spherulites to dendrites. In this investigation, we discuss the reasons of the differences in depth.


Sign in / Sign up

Export Citation Format

Share Document