Physical Properties of Four Acrylic Denture Base Resisns

2005 ◽  
Vol 6 (4) ◽  
pp. 93-100 ◽  
Author(s):  
Thomas R. Meng ◽  
Mark A. Latta

Abstract Resistance to impact fracture and high flexural strength are desirable properties of denture base acrylics. The purpose of this laboratory study was to determine the Izod impact strength, the flexural strength, the flexural modulus, and the yield distance for four premium denture resins. Bar specimens 86 x 11 x 3 mm of Lucitone 199, Fricke Hi-I, ProBase Hot, and Sledgehammer Maxipack were fabricated following the manufacturer's instructions for heat processing. The bars were surface finished using silicon carbide paper to 600 grit. Ten specimens from three lots of each material were made (n=30). Flexural strength, flexural modulus, and yield distance were determined by testing the specimens to failure using a three-point test fixture. Izod impact strength was determined using an Izod tester on un-notched specimens generated from the flexural test (n=60). Analysis of variance (ANOVA) and post-hoc Tukey's test were used for statistical comparison of each property. There were significant differences in the physical properties among the denture acrylics tested. Lucitone 199 demonstrated the highest impact strength, flexural strength, and yield distance (p<0.05). Lucitone 199 with an Izod impact strength of 5.5 ± 1.2 N·m, a flexural strength of 99.5 ± 4.5 MPa, and yield distance of 9.9 ± 0.76 mm exhibited statistically greater results than Fricki Hi-I, ProBase Hot, and Sledgehammer Maxipack. Fricki Hi- I with a yield distance of 7.3 ± 1.1 mm was statically greater than ProBase Hot and Sledgehammer Maxipack. Fricki Hi-I, ProBase Hot, and Sledgehammer Maxipack were statistically similar for the Izod impact strength and flexural strength tests performed. ProBase Hot and Sledgehammer Maxipack yielded statistically similar results for all tests performed. Flexural modulus had an inverse relationship to the impact strength, flexural strength, and yield distance. Citation Meng TR, Latta MA. Physical Properties of Four Acrylic Denture Base Resins. J Contemp Dent Pract 2005 November;(6)4:093-100.

2021 ◽  
Vol 2021 ◽  
pp. 1-7
Author(s):  
Ngoc-Thien Tran ◽  
Nga Thi-Hong Pham

Polybutylene terephthalate (PBT) is a brittle polymer with the disadvantage of low impact toughness, so it is not easy to meet the requirements of both high tensile strength, flexural strength, and high impact strength. In this study, PBT/polycarbonate (PC) blends at different ratios of 95/5, 90/10, 85/15, and 80/20 are investigated. Tensile strength, flexural strength, and unnotched Izod impact strength are studied according to the ASTM D638, ASTM D790, and ASTM D256 standards. The results show that tensile strength, which increased with increasing PC content, is 53.00, 62.34, 60.59, 62.98, and 64.46 MPa for 0, 5, 10, 15, and 20% PC samples. Flexural strength and elastic flexural testing of PBT/PC blends are higher than neat PBT. In addition, the unnotched Izod impact strength of PBT/PC is also higher than PBT. However, when PC content increases, impact strength tends to decrease. Impact strength is 44.82, 80.46, 68.82, 50.45, and 48.05 kJ/m2 corresponds to 0, 5, 10, 15, and 20% PC, in which 5% PC sample is twice as high as the impact strength of PBT. Microstructure of the blends has shown that PC has become dispersed phase in PBT matrix. The size and quantity of dispersed PC particles increase with increasing PC rate in the blend. Thus, when adding PC, PBT/PC all meet the requirements of high tensile strength, flexural strength, and high impact strength. The PBT/5% PC model gives the highest impact strength while still ensuring durability, which potential application for making car door handles.


Materials ◽  
2019 ◽  
Vol 12 (24) ◽  
pp. 4146 ◽  
Author(s):  
Grzegorz Chladek ◽  
Katarzyna Pakieła ◽  
Wojciech Pakieła ◽  
Jarosław Żmudzki ◽  
Marcin Adamiak ◽  
...  

Colonization of polymeric dental prosthetic materials by yeast-like fungi and the association of these microorganisms with complications occurring during prosthetic treatment are important clinical problems. In previously presented research, submicron inorganic particles of silver sodium hydrogen zirconium phosphate (S–P) were introduced into poly(methyl methacrylate) (PMMA) denture base material which allowed for obtaining the antimicrobial effect during a 90 day experiment. The aim of the present study was to investigate the flexural strength, impact strength, hardness, wear resistance, sorption, and solubility during three months of storage in distilled water. With increasing S–P concentration after 2 days of conditioning in distilled water, reduced values of flexural strength (107–72 MPa), impact strength (18.4–5.5 MPa) as well as enhanced solubility (0.95–1.49 µg/mm3) were registered, but they were at acceptable levels, and the sorption was stable. Favorable changes included increased hardness (198–238 MPa), flexural modulus (2.9–3.3 GPa), and decreased volume loss during wear test (2.9–0.2 mm3). The percentage changes of the analyzed properties during the 90 days of storage in distilled water were similar for all materials.


2009 ◽  
Vol 20 (2) ◽  
pp. 132-137 ◽  
Author(s):  
Rafael Leonardo Xediek Consani ◽  
Douglas Duenhas de Azevedo ◽  
Marcelo Ferraz Mesquita ◽  
Wilson Batista Mendes ◽  
Paulo César Saquy

The present study evaluated the effect of repeated simulated microwave disinfection on physical and mechanical properties of Clássico, Onda-Cryl and QC-20 denture base acrylic resins. Aluminum patterns were included in metallic or plastic flasks with dental stone following the traditional packing method. The powder/liquid mixing ratio was established according to the manufacturer's instructions. After water-bath polymerization at 74ºC for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling and finished. Each specimen was immersed in 150 mL of distilled water and underwent 5 disinfection cycles in a microwave oven set at 650 W for 3 min. Non-disinfected and disinfected specimens were subjected to the following tets: Knoop hardness test was performed with 25 g load for 10 s, impact strength test was done using the Charpy system with 40 kpcm, and 3-point bending test (flexural strength) was performed at a crosshead speed of 0.5 mm/min until fracture. Data were analyzed statistically by ANOVA and Tukey's test (α= 0.05%). Repeated simulated microwave disinfections decreased the Knoop hardness of Clássico and Onda-Cryl resins and had no effect on the impact strength of QC-20. The flexural strength was similar for all tested resins.


2010 ◽  
Vol 21 (1) ◽  
pp. 55-59 ◽  
Author(s):  
Fabiana Gouveia Straioto ◽  
Antonio Pedro Ricomini Filho ◽  
Alfredo Júlio Fernandes Neto ◽  
Altair Antoninha Del Bel Cury

The addition of different polymers, such as polytetrafluorethylene (PTFE), to denture base resins could be an option to modify acrylic resin mechanical properties. This study evaluated the surface hardness, impact and flexural strength, flexural modulus and peak load of 2 acrylic resins, one subjected to a long and another subjected to a short polymerization cycle, which were prepared with or without the addition of 2% PTFE. Four groups were formed according to the polymerization cycle and addition or not of PTFE. Forty specimens were prepared for each test (10 per group) with the following dimensions: hardness (30 mm diameter x 5 mm thick), impact strength (50 x 6 x 4 mm) and flexural strength (64 x 10 x 3.3 mm) test. The results of the flexural strength test allowed calculating flexural modulus and peak of load values. All tests were performed in accordance with the ISO 1567:1999 standard. Data were analyzed statistically by ANOVA and Tukey's test with the level of significance set at 5%. No statistically significant differences (p>0.05) were found for surface hardness. Flexural strength, impact strength and peak load were significantly higher (p<0.05) for resins without added PTFE. The flexural modulus of the acrylic resin with incorporated 2% PTFE polymerized by long cycle was significantly higher (p<0.05) than that of the other resins. Within the limits of this study, it may be concluded that the addition of PTFE did not improve the mechanical properties of the evaluated acrylic resins.


2013 ◽  
Vol 14 (6) ◽  
pp. 1115-1121
Author(s):  
N Simhachalam Reddy ◽  
R Narendra ◽  
Sashi Deepth Reddy ◽  
CR Sashi Purna ◽  
M Chandra Shekar ◽  
...  

ABSTRACT The denture bases made by using polymethyl methacrylates of Acrylic resin family have excellent physical properties, simple to process and easy to reline, rebase and repair. One of the inherent disadvantages of this material is the liability to break during function. The strength assessment of acrylic resins have been made generally by transverse deflection tests. Aim To evaluate the impact strength valves of certain brands of commercially available denture base resins and suggest their suitability. Materials and methods The denture bases we made using polymethyl methacrylates of acrylic resin family because they have excellent physical properties, simple to process and easy to reline and rebase. Six commercial brands of polymethyl methacrylate, namely Stellon (DPI-India), Acralyn-H (Asian Acrylate, India), Trevalon (Dentsply-England), Lucitone 199 (Dentsply/ York division), Acralyn-H (Super Unbreakable), Trevalon HI (Dentsply, Detray division, England) were tested by breaking them using Analog Pendulum (ASTM D 256). Results From the entire study the maximum impact strength was reported for Acralyn-H super unbreakable (Asian Acrylates, India) 62.19 joules. Conclusion All the analysis led to conclusion that there is basic change in material composition within and among the different groups of denture base resins. Clinical implications The complete dentures made using denture base resins with high impact strength valves (e.g. Acralyn-H super unbreakable) will be more durable and can be used by the patient for considerable period of time, i.e. beyond 4 to 5 years. How to cite this article Narendra R, Reddy NS, Reddy SD, Purna CRS, Shekar MC, Balasubramanyam S. A Comparative Evaluation of Impact Strength of Conventionally Heat Cured and High Impact Heat Cured Polymethyl Metharylate Denture Base Resins: An in vitro Study. J Contemp Dent Pract 2013;14(6): 1115-1121.


2010 ◽  
Vol 123-125 ◽  
pp. 1139-1142 ◽  
Author(s):  
Sawitri Srisuwan ◽  
Pranee Chumsamrong

In this study, the effects of weave type and fiber content on the physical properties of woven sisal fiber/epoxy composites were investigated. Sisal fibers used in this work were obtained from Nakhon Ratchasima, Thailand. Both untreated and alkali-treated fibers were employed. The woven sisal fibers were manufactured by hand weaving process. The fiber content in sisal fiber/epoxy composites were 3 wt.%, 5 wt.% and 10 wt.%. The composites were cured at room temperatures. In order to determine mechanical properties of the composites, flexural and impact tests were applied. Flexural strength and flexural modulus of all composites were higher than those of pure epoxy resin and tended to increase with increasing fiber content. The impact strength of all composites was lower than that of pure epoxy resin. The composites containing 10 wt.% sisal fibers showed the highest impact strength. There was no definite influence of weave type on flexural properties of the composites. At 3 and 5 wt.% fiber, the composites containing plain weave fibers seemed to show a higher impact strength than the composites containing other weave types.


Polymers ◽  
2019 ◽  
Vol 11 (12) ◽  
pp. 1976 ◽  
Author(s):  
Xiong Wang ◽  
Sheng Hu ◽  
Yi Guo ◽  
Guangquan Li ◽  
Renwei Xu

Polyolefin is the most widely used and versatile commodity polymer. In this work, three types of polyolefin-based elastomers (PBEs) were adopted to toughen a high-flow polypropylene to improve its overall performance. The chain microstructures of these PBEs, including ethylene/1-octene (E/O) random copolymer from Dow Chemical′s polyolefin elastomer (POE), olefin block copolymers (OBCs) of E/O from Dow, and ethylene/propylene random copolymer from ExxonMobil’s propylene-based elastomer, were elucidated by GPC, 13C NMR, TREF, and DSC techniques. The mechanical, thermal and optical properties, and morphology analysis of the PP/PBE blends were also studied to investigate the toughening mechanism of these PBEs. The results showed that all three types of PBEs can effectively improve the Izod impact strength of the PP/PBE blends by the addition of the rubber compositions, at the cost of the stiffness. PBE-1 and PBE-2 were found to have a great stiffness–toughness balance with about 1700 MPa of flexural modulus, about 110 °C of HDT and 3.6 kJ/m2 of impact strength on the prepared PP/PBE blends by forming separated rubber phase and refined spherulite crystals. As a result, the OBC with alternating hard and soft segments could achieve a similar toughening effect as the E/P random copolymer. Surprisingly, no obvious rubber phase separation was observed in the PP/PBE-4 blend, which might be due to the good compatibility of the E/P random chains with the isotactic PP; therefore, the PP/PBE blend obtains great toughness performance and optical transparency with the highest Izod impact strength of 4.2 kJ/m2 and excellent transparency.


2019 ◽  
Vol 2019 ◽  
pp. 1-11 ◽  
Author(s):  
Mohammed M. Gad ◽  
Ahmad M. Al-Thobity ◽  
Ahmed Rahoma ◽  
Reem Abualsaud ◽  
Fahad A. Al-Harbi ◽  
...  

This study is aimed at evaluating the hybrid reinforcement effects of zirconium oxide nanoparticles (nano-ZrO2) and glass fibers (GFs) at different ratios on the flexural and impact strengths of a polymethylmethacrylate (PMMA) denture base. A total of 160 specimens were fabricated from heat-polymerized acrylic resins using the water bath technique. For the control group, the specimens did not receive any additions; for the test group, different concentrations of nano-ZrO2/GFs at 5% of the PMMA polymer were added. The concentrations of nano-ZrO2/GFs were as follows: 5%–0%, 4%–1%, 3%–2%, 2.5%–2.5%, 2%–3%, 1%–4%, and 0%–5%. The flexural strength was measured using the three-point bending test. The impact strength was measured using the Charpy impact test. Results were tabulated and analyzed using one-way analysis of variance (ANOVA) and the Tukey–Kramer multiple comparison test (p≤0.05). The flexural and impact strengths of PMMA-nano-ZrO2 + GF composites were significantly improved when compared with those of pure PMMA (p<0.05). The maximum flexural strength (94.05 ± 6.95 MPa) and impact strength (3.89 ± 0.46 kJ/m2) were obtained with PMMA (2.5%)/nano-ZrO2 + 2.5% GF mixtures and could be used for removable prosthesis fabrication.


2013 ◽  
Vol 701 ◽  
pp. 225-228 ◽  
Author(s):  
Japar Sahari ◽  
S.M. Sapuan ◽  
Edi Syam Zainudin ◽  
Md Abdul Maleque

The effect of glycerol concentration (15 w/w%, 20 w/w%, 30 w/w% and 40 w/w%) to the flexural and impact properties of plasticized sugar palm starch (SPS) was investigated in this present paper. Prior to the testing, the sugar palm starch extracted from the interior part of sugar palm stem was mixed with common glycerol (was used as a plasticizer) to form a novel biopolymer. The flexural and impact test were carried out according to ASTM D790 and ASTM 256 respectively. From this investigation, it is found that the 30% glycerol concentrated SPS biopolymer showed the highest flexural strength and flexural modulus with the value of 0.13 MPa and 87.54 MPa respectively. For the impact analysis, it is also found that same biopolymer showed the highest impact strength which is 6.13kJ/m2.


Author(s):  
Piyali Sarkar ◽  
Sandeep Garg ◽  
Nidhi Mangtani Kalra

Abstract Aim This article evaluates the effect of incorporating different concentrations of silver nanoparticles as an antimicrobial agent on the flexural and impact strength of heat-cured denture base resin. Material and Methods A total of 80 specimens of polymethyl methacrylate resin were fabricated (40 for flexural strength and 40 for impact strength). Specimens were fabricated using stainless steel die of dimension 65 mm × 10 mm × 2.5 mm as per the American Dental Association specification no. 12, and 50 mm × 6 mm × 4 mm as per ISO 1567:1999 for flexural strength and impact strength, respectively, and were divided into four groups (A, B, C, and D) based on the concentrations of silver nanoparticles (0%, 2.5%, 5%, and 10%). The specimens were subjected to three-point bending test and Izod impact tester for testing flexural and impact strength, respectively. Data obtained was compiled and analyzed using one-way analysis of variance and post hoc tests. Results Results showed that for both the properties, maximum strength was observed in group A (control) followed by groups B and C, and minimum was observed in group D. A statistically significant difference in flexural strength was found among all the groups, whereas no statistically significant difference in impact strength was found among any of the groups. Conclusion Within the limitations of this in vitro study, it was concluded that though incorporation of silver nanoparticles exhibited no effect on the impact strength of heat cure denture base resin, it decreased the flexural strength, so it should be used cautiously.


Sign in / Sign up

Export Citation Format

Share Document