scholarly journals A multilevel fast spectral domain algorithm for electromagnetic analysis of infinite periodic arrays with large unit cells

2006 ◽  
Vol 4 ◽  
pp. 41-47 ◽  
Author(s):  
T. F. Eibert

Abstract. A multilevel fast spectral domain algorithm (MLFSDA) is introduced for the efficient evaluation of the matrix vector products due to the boundary integral (BI) operator within a hybrid finite element - BI (FEBI) method for the analysis of infinite periodic arrays. The MLFSDA utilizes the diagonalization property of the spectral domain (SD) BI representation and handles the large numbers of Floquet modes required for large (with respect to wavelength) periodic unit cells by similar hierarchical techniques as applied in the multilevel fast multipole method/algorithm (MLFMM/MLFMA). With the capability of the MLFSDA to handle very large periodic unit cells, it becomes possible to model finite antennas and scatterers with the infinite periodic array model. For a cavity-backed antenna element and for a semi-finite array of 4 cavity-backed antenna elements in the finite direction, the dependence of the input impedances on the unit cell sizes is investigated and it is found that array resonances disappear for reasonably large unit cell dimensions. Finally, a semi-finite array of antipodal Vivaldi antenna elements is considered and simulation results for infinite periodic, finite, and semi-finite array configurations are compared to measured data.

2021 ◽  
Vol 11 (3) ◽  
pp. 1171
Author(s):  
Chang Xu ◽  
Zhihong Sun ◽  
Guowei Shao

Two-unit cells developed to predict the effective thermal conductivities of four-directional carbon/carbon composites with the finite element method are proposed in this paper. The smaller-size unit cell is formulated from the larger-size unit cell by two 180° rotational transformations. The temperature boundary conditions corresponding to the two-unit cells are derived, and the validity is verified by the temperature and heat flux distributions at specific positions of the larger-size unit cell and the smaller-size unit cell. The thermal conductivities of the carbon fiber bundles and carbon fiber rods are measured firstly. Then, combined with the properties of the matrix, the effective thermal conductivities of the four-directional carbon/carbon composites are numerically predicted. The results in transverse direction predicted by the larger-size unit cell and the smaller-size unit cell are both higher than experimental values, which are 5.8 to 6.2% and 7.3 to 8.2%, respectively. In longitudinal direction, the calculated thermal conductivities of the larger-size unit cell and the smaller-size unit cell are 6.8% and 6.2% higher than the experimental results, respectively. In addition, carbon fiber rods with different diameters are set to clarify the influence on the effective thermal conductivities of the four-directional carbon/carbon composites.


2017 ◽  
Vol 42 (1) ◽  
pp. 37-48 ◽  
Author(s):  
Leilei Chen ◽  
Wenchang Zhao ◽  
Cheng Liu ◽  
Haibo Chen

Abstract A FEM-BEM coupling approach is used for acoustic fluid-structure interaction analysis. The FEM is used to model the structure and the BEM is used to model the exterior acoustic domain. The aim of this work is to improve the computational efficiency and accuracy of the conventional FEM-BEM coupling approach. The fast multipole method (FMM) is applied to accelerating the matrix-vector products in BEM. The Burton-Miller formulation is used to overcome the fictitious eigen-frequency problem when using a single Helmholtz boundary integral equation for exterior acoustic problems. The continuous higher order boundary elements and discontinuous higher order boundary elements for 2D problem are developed in this work to achieve higher accuracy in the coupling analysis. The performance for coupled element types is compared via a simple example with analytical solution, and the optimal element type is obtained. Numerical examples are presented to show the relative errors of different coupled element types.


2015 ◽  
Vol 16 (2) ◽  
pp. 281
Author(s):  
Tariq Rahim ◽  
Jiodong Xu

A low profile multi layer miniaturized unit cell frequency selective surface (FSS) with second-order band-pass response is design. The metallic layers in the form of capacitive patches and inductive grids are separated by dielectric substrates. The non-resonant sub-wavelength unit cells with unit cell dimensions and periodicities on the order of 0.15λ. The overall thickness of approximately 0.03λ is designed which is useful at lower frequencies with long wavelengths. The FSS exhibit a stable frequency response to different angles of incidence and polarizations. The analysis and synthesis of the FSS is done using equivalent circuit method and simulated using CST microwave studio at X-band.


2020 ◽  
Vol 76 (3) ◽  
pp. 345-357 ◽  
Author(s):  
Josef Simbrunner ◽  
Benedikt Schrode ◽  
Jari Domke ◽  
Torsten Fritz ◽  
Ingo Salzmann ◽  
...  

Crystal structure identification of thin organic films entails a number of technical and methodological challenges. In particular, if molecular crystals are epitaxially grown on single-crystalline substrates a complex scenario of multiple preferred orientations of the adsorbate, several symmetry-related in-plane alignments and the occurrence of unknown polymorphs is frequently observed. In theory, the parameters of the reduced unit cell and its orientation can simply be obtained from the matrix of three linearly independent reciprocal-space vectors. However, if the sample exhibits unit cells in various orientations and/or with different lattice parameters, it is necessary to assign all experimentally obtained reflections to their associated individual origin. In the present work, an effective algorithm is described to accomplish this task in order to determine the unit-cell parameters of complex systems comprising different orientations and polymorphs. This method is applied to a polycrystalline thin film of the conjugated organic material 6,13-pentacenequinone (PQ) epitaxially grown on an Ag(111) surface. All reciprocal vectors can be allocated to unit cells of the same lattice constants but grown in various orientations [sixfold rotational symmetry for the contact planes (102) and (102)]. The as-determined unit cell is identical to that reported in a previous study determined for a fibre-textured PQ film. Preliminary results further indicate that the algorithm is especially effective in analysing epitaxially grown crystallites not only for various orientations, but also if different polymorphs are present in the film.


1989 ◽  
Vol 53 (371) ◽  
pp. 385-386 ◽  
Author(s):  
H. De Bruiyn ◽  
G. J. Beukes ◽  
W. A. Van Der Westhuizen ◽  
E. A. W. Tordiffe

AT the time when the hydrated aluminium phosphate-sulphate hotsonite (Beukes et al., 1984a) and its equally rare relative zaherite (Beukes et al., 1984b; De Bruiyn et al., 1985) were discovered near Pofadder, South Africa, very little was known about the unit cells of the other two hydrated aluminium phosphate-sulphate minerals sanjuanite and kribergite, originally described by De Abeledo et al. (1968) from Argentina and Sweden, respectively. Although the Powder Diffraction file (PDF) contains the X-ray diffraction patterns for sanjuanite and kribergite (PDF 20-47 and 20-48 respectively), they had not been indexed nor have their unit cell parameters been calculated thus far.


Author(s):  
Jacob Kephart ◽  
G. F. Jones

Constructal principles are used to investigate the optimization of material utilization in a metal matrix heat sink that maximizes the total heat transfer rate through the base of heat sink. This approach utilizes a two-dimensional geometry to examine spatial heat flow and optimal material distribution in a metal matrix in the plane perpendicular to the coolant flow direction. The matrix is composed of multiple layers of conductive tees built up from the smallest constituent, the unit T-cell. The unit cell consists of a conductive tee-shaped geometry with the two rectangular void regions each making up half of a cooling channel. The horizontal boundaries must match the temperature and heat flux at the boundaries of the neighboring unit cells as this is a conjugate conduction/convection problem. The geometry of the unit cell is characterized by aspect ratios of channel width to height, overall cell width to height, and channel height to cell height. The matrix structure is assembled by stacking unit cells into multiple layers where the number of cells in each layer is an integer multiple of the cells contained in the lower layer. The solution is obtained for optimal T-cell geometric parameters under a set of predetermined constraints including overall volume, solid fill fraction, and number of layers. When a large number of stacked unit cells are considered, the results describe the ideal spatial distribution of porosity and pore sizes for two dimensional functionally graded metal-matrix heat sink. These results will lead to a better understanding of the role played by the porosity distribution in a metal-matrix heat sink and may be applied to the analysis, optimization, and design of more effective heat sinks.


1969 ◽  
Vol 43 (3) ◽  
pp. 448-455 ◽  
Author(s):  
Irmin Sternlieb ◽  
Jacob E. Berger

Unit cell dimensions of mitochondrial crystals were determined by optical diffraction analysis of electron micrographs of human liver biopsy specimens. Identical unit cells were found in pathologic material obtained from six patients with Wilson's disease, from one patient with sickle-cell hepatitis, and from two normal subjects. These measurements led to the conclusion that the crystals observed in patients and in normal subjects were probably chemically identical. Furthermore, the relatively large size of the unit cell limits the choices for its constituents to phospholipid micelles or to relatively large protein molecules.


Author(s):  
L. W. Labaw

Crystals of a human γGl immunoglobulin have the external morphology of diamond shaped prisms. X-ray studies have shown them to be monoclinic, space group C2, with 2 molecules per unit cell. The unit cell dimensions are a = 194.1, b = 91.7, c = 51.6Å, 8 = 102°. The relatively large molecular weight of 151,000 and these unit cell dimensions made this a promising crystal to study in the EM.Crystals similar to those used in the x-ray studies were fixed at 5°C for three weeks in a solution of mother liquor containing 5 x 10-5M sodium phosphate, pH 7.0, and 0.03% glutaraldehyde. They were postfixed with 1% osmium tetroxide for 15 min. and embedded in Maraglas the usual way. Sections were cut perpendicular to the three crystallographic axes. Such a section cut with its plane perpendicular to the z direction is shown in Fig. 1.This projection of the crystal in the z direction shows periodicities in at least four different directions but these are only seen clearly by sighting obliquely along the micrograph.


Author(s):  
L. Fei ◽  
P. Fraundorf

Interface structure is of major interest in microscopy. With high resolution transmission electron microscopes (TEMs) and scanning probe microscopes, it is possible to reveal structure of interfaces in unit cells, in some cases with atomic resolution. A. Ourmazd et al. proposed quantifying such observations by using vector pattern recognition to map chemical composition changes across the interface in TEM images with unit cell resolution. The sensitivity of the mapping process, however, is limited by the repeatability of unit cell images of perfect crystal, and hence by the amount of delocalized noise, e.g. due to ion milling or beam radiation damage. Bayesian removal of noise, based on statistical inference, can be used to reduce the amount of non-periodic noise in images after acquisition. The basic principle of Bayesian phase-model background subtraction, according to our previous study, is that the optimum (rms error minimizing strategy) Fourier phases of the noise can be obtained provided the amplitudes of the noise is given, while the noise amplitude can often be estimated from the image itself.


Sign in / Sign up

Export Citation Format

Share Document