Determination of Ocular Irritancy Potential of Ophthalmic products using HET-CAM Method

Author(s):  
Anand Babu K ◽  
Ram Narayanan R

Objective: The research is about the stability of ophthalmic products as they start to produce irritancy effects during their shelf life. The aim of the present study is to assess the stability of certain ophthalmic products by the HET-CAM (Hen’s Egg Test-Chorioallatonic membrane) Method. Method: Incubated Eggs were utilized for performing the HET-CAM assay according to the protocol prescribed by ICCVAM (The Inter agency Coordinating Committee on the Validation of Alternative Methods). Results: Calculation of various irritancy factors like hemorrhage time, vascular lysis time and coagulation time and to calculate HET-CAM score. Statistical interpretation of the data obtained by one-way ANOVA. Conclusion: Results have shown that the few ophthalmic products are slight and moderate irritants. None of the products are strong irritants. However further studies to be conducted to confirm the potential and safety of the products.

1966 ◽  
Vol 16 (01/02) ◽  
pp. 001-017 ◽  
Author(s):  
W Berg ◽  
K Korsan-Bengtsen ◽  
J Ygge

SummaryA one-stage lysis time system containing fibrinogen, streptokinase, thrombin, and a known, small amount of plasminogen was used to determine plasminogen in plasma.The known amount of plasminogen was added to the system in order to keep the lysis times relatively short when a highly diluted plasma was tested. High dilutions of plasma were used to reduce the influence of the plasma inhibitors.The calculation of the plasminogen concentration was made on the basis of the correlation: “plasminogen = fibrinogen/lysis time” which was valid in the system. The method allowed determination of plasminogen in plasma with varying fibrinogen concentrations, as the fibrinogen concentration in plasma was considered in the calculation.The presence of “spontaneous” plasmin activity in the plasma did not influence the plasminogen determination. Estimated by this method, the plasminogen content in plasma from 32 blood donors aged 25-45 years was 13.1 ±2.4 casein u/ml. The error of a single determination was 0.3 casein u/ml. The plasminogen content in plasma, determined with the present method, is about 3-4 times higher than the content found when a caseinolytic method is used.


Author(s):  
Sunny Katyara ◽  
Lukasz Staszewski ◽  
Faheem Akhtar Chachar

Background: Since the distribution networks are passive until Distributed Generation (DG) is not being installed into them, the stability issues occur in the distribution system after the integration of DG. Methods: In order to assure the simplicity during the calculations, many approximations have been proposed for finding the system’s parameters i.e. Voltage, active and reactive powers and load angle, more efficiently and accurately. This research presents an algorithm for finding the Norton’s equivalent model of distribution system with DG, considering from receiving end. Norton’s model of distribution system can be determined either from its complete configuration or through an algorithm using system’s voltage and current profiles. The algorithm involves the determination of derivative of apparent power against the current (dS/dIL) of the system. Results: This work also verifies the accuracy of proposed algorithm according to the relative variations in the phase angle of system’s impedance. This research also considers the varying states of distribution system due to switching in and out of DG and therefore Norton’s model needs to be updated accordingly. Conclusion: The efficacy of the proposed algorithm is verified through MATLAB simulation results under two scenarios, (i) normal condition and (ii) faulty condition. During normal condition, the stability factor near to 1 and change in dS/dIL was near to 0 while during fault condition, the stability factor was higher than 1 and the value of dS/dIL was away from 0.


2016 ◽  
Vol 5 (10) ◽  
pp. 4920
Author(s):  
Amar M. Ali ◽  
Hussain. J. Mohammed*

A new, simple, sensitive and rapid spectrophotometric method is proposed for the determination of trace amount of Nickel (II). The method is based on the formation of a 1:2 complex with 4-(4-((2-hydroxy-6-nitrophenyl) diazenyl) -3-methyl-5-oxo-2, 5-dihydro-1H-pyrazol-1-yl) benzenesulfonic acid (2-ANASP) as a new reagent is developed. The complex has a maximum absorption at 516 nm and εmax of 1. 84 X 105 L. mol-1. cm-1. A linear correlation (0. 25 – 4. 0μg. ml-1) was found between absorbance at λmax and concentration. The accuracy and reproducibility of the determination method for various known amounts of Nickel (II) were tested. The results obtained are both precise (RSD was 1. 2 %) and accurate (relative error was 0. 787 %). The effect of diverse ions on the determination of Nickel (II) to investigate the selectivity of the method were also studied. The stability constant of the product was 0. 399 X 106 L. mol-1. The proposed method was successfully applied to the analysis of diabetes blood and normal human blood. 


Symmetry ◽  
2021 ◽  
Vol 13 (4) ◽  
pp. 525 ◽  
Author(s):  
Mehdi Keshavarz-Ghorabaee ◽  
Maghsoud Amiri ◽  
Edmundas Kazimieras Zavadskas ◽  
Zenonas Turskis ◽  
Jurgita Antucheviciene

The weights of criteria in multi-criteria decision-making (MCDM) problems are essential elements that can significantly affect the results. Accordingly, researchers developed and presented several methods to determine criteria weights. Weighting methods could be objective, subjective, and integrated. This study introduces a new method, called MEREC (MEthod based on the Removal Effects of Criteria), to determine criteria’ objective weights. This method uses a novel idea for weighting criteria. After systematically introducing the method, we present some computational analyses to confirm the efficiency of the MEREC. Firstly, an illustrative example demonstrates the procedure of the MEREC for calculation of the weights of criteria. Secondly, a comparative analysis is presented through an example for validation of the introduced method’s results. Additionally, we perform a simulation-based analysis to verify the reliability of MEREC and the stability of its results. The data of the MCDM problems generated for making this analysis follow a prevalent symmetric distribution (normal distribution). We compare the results of the MEREC with some other objective weighting methods in this analysis, and the analysis of means (ANOM) for variances shows the stability of its results. The conducted analyses demonstrate that the MEREC is efficient to determine objective weights of criteria.


Materials ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 1976
Author(s):  
Tomasz Garbowski ◽  
Tomasz Gajewski

Knowing the material properties of individual layers of the corrugated plate structures and the geometry of its cross-section, the effective material parameters of the equivalent plate can be calculated. This can be problematic, especially if the transverse shear stiffness is also necessary for the correct description of the equivalent plate performance. In this work, the method proposed by Biancolini is extended to include the possibility of determining, apart from the tensile and flexural stiffnesses, also the transverse shear stiffness of the homogenized corrugated board. The method is based on the strain energy equivalence between the full numerical 3D model of the corrugated board and its Reissner-Mindlin flat plate representation. Shell finite elements were used in this study to accurately reflect the geometry of the corrugated board. In the method presented here, the finite element method is only used to compose the initial global stiffness matrix, which is then condensed and directly used in the homogenization procedure. The stability of the proposed method was tested for different variants of the selected representative volume elements. The obtained results are consistent with other technique already presented in the literature.


Molecules ◽  
2021 ◽  
Vol 26 (7) ◽  
pp. 2039
Author(s):  
Gamal A. E. Mostafa ◽  
Ahmed Bakheit ◽  
Najla AlMasoud ◽  
Haitham AlRabiah

The reactions of ketotifen fumarate (KT) with 2,3-dichloro-5,6-dicyano-p-benzoquinone (DDQ) and 7,7,8,8-tetracyanoquinodimethane (TCNQ) as π acceptors to form charge transfer (CT) complexes were evaluated in this study. Experimental and theoretical approaches, including density function theory (DFT), were used to obtain the comprehensive, reliable, and accurate structure elucidation of the developed CT complexes. The CT complexes (KT-DDQ and KT-TCNQ) were monitored at 485 and 843 nm, respectively, and the calibration curve ranged from 10 to 100 ppm for KT-DDQ and 2.5 to 40 ppm for KT-TCNQ. The spectrophotometric methods were validated for the determination of KT, and the stability of the CT complexes was assessed by studying the corresponding spectroscopic physical parameters. The molar ratio of KT:DDQ and KT:TCNQ was estimated at 1:1 using Job’s method, which was compatible with the results obtained using the Benesi–Hildebrand equation. Using these complexes, the quantitative determination of KT in its dosage form was successful.


Sign in / Sign up

Export Citation Format

Share Document