scholarly journals Analysis of Surface Roughness and 3D Scanning Topography of Zirconia Implants Before and After Photofunctionalisation by 3D Optical Profilometry- An Invitro Study

Author(s):  
Arunjaikumar Ravindran ◽  
Suma Karthigeyan ◽  
Ramesh Bhat ◽  
Madhulika Naidu ◽  
Senthilnathan Natarajan ◽  
...  

Introduction: Zirconia is considered as an alternative material for the fabrication of implants. Surface roughness of the implant plays a fundamental role in the initial bone formation. The rationale of using 3D optical profilometry in this study was to evaluate the surface roughness of the zirconia implants before and after Ultraviolet (UV) photofunctionalisation. Also, Moreso 3D optical instruments have a better resolution than the mechanical ones like Atomic Force Microscopy (AFM). Aim: To analyse the surface roughness and topography of zirconia implants after photofunctionalisation using optical profilometry. Materials and Methods: This is an in-vitro study conducted over a period of six months from March 2020 to August 2020. Ten commercially machined Zirconia implants, five each in study and control group, were micro analysed at three different regions (abutment, thread and crest) by optical profilometry. Study group was surface treated by UV radiation for 48 hours. Quantitative morphometric analysis was done between two groups and p-value less than 0.05 was considered statistically significant. The statistical test applied in this study was independent t-test. Results: Scanning micrographs of the study group revealed highest density of summits contributing to increased surface area in the study group. Quantitative analysis of surface roughness showed statistically significant higher mean roughness parameter for photofunctionalised implants in abutment, crest and thread region (p<0.05). Conclusion: Photofunctionalisation is a potentially synergistic technique in producing textured zirconia implants.

2006 ◽  
Vol 14 (2) ◽  
pp. 124-129 ◽  
Author(s):  
Fernanda Vieira Ribeiro ◽  
Renato Correa Viana Casarin ◽  
Francisco Humberto Nociti Júnior ◽  
Enilson Antônio Sallum ◽  
Antonio Wilson Sallum ◽  
...  

OBJECTIVE: The purpose of this study was to evaluate the root surface roughness after instrumentation with hand curette and diamond-coated sonic and universal ultrasonic tips. MATERIALS AND METHODS: Forty root surfaces of human teeth were randomly assigned to four treatment groups: control group (without instrumentation), curette instrumentation, ultrasonic instrumentation with universal tip and sonic instrumentation with diamond-coated tip. Each sample was instrumented with fifteen strokes. Before and after instrumentation, surface roughness was measured. In addition, the root surface topography was examined after treatment under the scanning electron microscope. RESULTS: Significant statistical differences (p <0.05) were observed when comparing the control group (0.48±0.07mm) to the treated groups (hand - 1.246±0.279mm, ultrasonic - 1.468±0.177mm and sonic instrumentation - 1.576±0.20mm). The highest roughness was produced by diamond-coated sonic tip and by ultrasonic universal tip (p >0.05). CONCLUSION: The diamond-coated tip with sonic scaler instrumentation and ultrasonic instrumentation produce similar root surface roughness, higher than curette instrumentation.


2008 ◽  
Vol 100 (10) ◽  
pp. 693-698 ◽  
Author(s):  
Michael Buerke ◽  
Sebastian Schubert ◽  
Iris Reindl ◽  
Thomas Michel ◽  
Baerbel Hauroeder ◽  
...  

SummaryBivalirudin, a direct thrombin inhibitor binds specifically and reversibly to both fibrin-bound and unbound thrombin. Bivalirudin is approved for use as an anticoagulant in patients undergoing percutaneous coronary intervention. The OASIS-5 trial presented a significant increase in cardiac catheter thrombosis for the pentasaccharid fondaparinux compared to enoxaparin. Catheter thrombosis has never been reported in any trial using bivalirudin. Our study compared the development of catheter thrombosis for bivalirudin, enoxaparin, and unfractionated heparin in a controlled in-vitro environment. Ten healthy male volunteers were pretreated with aspirin 500 mg 2 hours before venesection of 50 ml of blood. The seven groups of anticoagulant combinations tested were:UFH, UFH + eptifibatide, enoxaparin, enoxaparin + eptifibatide, bivalirudin bolus, bivalirudin + eptifibatide, bivalirudin bolus + continuous infusion. The blood/anticoagulant mix continuously circulated through a cardiac guiding catheter for 60 minutes or until the catheter became blocked with thrombus. Thrombus development was assessed by weighing each catheter before and after the procedure. Electron microscopy was used to quantify the degree of erythrocyte, platelet and fibrin deposition. Following anticoagulation with bolus dose bivalirudin, the catheter was invariably occluded with thrombus after 33 minutes of circulation. However, a continuous infusion of Bivalirudin prevented the development of occlusive catheter thrombosis. In the bolus bivalirudin group the mean thrombus weight was significantly greater than in all other groups (p-value < 0.01 in all analyses). Bivalirudin given as a bolus was not sufficient to prevent cardiac catheter thrombosis in our in-vitro study. However, a continuous infusion of bivalirudin had similar anti-thrombotic efficacy compared to other treatment strategies.


Author(s):  
Teresa Al Haddad ◽  
Elie Khoury ◽  
Nada Farhat Mchayleh

Abstract Objectives The aim of the present in vitro study is to compare the remineralization brushing effect of three toothpastes and Aloe vera (AV) gel. Materials and Methods Forty sound extracted teeth were placed in a demineralizing solution for 4 days and randomly assigned to four groups: group A: 1,450-ppm fluoride toothpaste; group B: AV nonfluoridated toothpaste; group C: AV 1,000-ppm fluoridated toothpaste; and group D: AV gel. A 3-minute pH cycling was performed twice a day for each group for 12 days. Specimens were analyzed before and after by scanning electron microscope—energy dispersive X-ray. Statistical analysis The outcomes were analyzed by Kolmogorov–Smirnov’s tests, repeated-measures analyses of variance followed by univariate analyses, and Bonferroni’s multiple comparisons tests to compare the calcium-to-phosphorus (Ca:P) ratio within time among toothpaste groups. Results Following remineralization, the Ca:P ratio increased in all groups. The difference of the Ca:P ratio was not significant between groups C, D, and A. The mean ratio was significantly lower in group B (p-value = 0.026). Conclusions The AV gel demonstrated a remineralization capacity equal to that of the 1,450-ppm fluoride toothpaste. In contrast, fluoride-free AV toothpaste showed a lower remineralization efficiency. Further studies are required to understand its mechanism.


Materials ◽  
2019 ◽  
Vol 12 (24) ◽  
pp. 4196
Author(s):  
Martina Eichenberger ◽  
Anna Iliadi ◽  
Despina Koletsi ◽  
George Eliades ◽  
Carlalberta Verna ◽  
...  

The aim of the present study was to quantitatively assess changes in enamel roughness parameters before and after lingual bracket debonding. The lingual surface of 25 sound premolars extracted for orthodontic reasons was studied by 3D optical interferometric profilometry before and after debonding of lingual brackets following enamel finishing (with fine diamond) and polishing (with 12- and 20-fluted carbide burs). The roughness parameters tested were the amplitude parameters Sa and Sz, the hybrid parameter Sdr, and the functional parameters Sc and Sv. The parameter differences (after debonding-reference) were calculated, and statistical analysis was performed via a Wilcoxon signed-rank test. Statistically significantly higher values were observed in all the surface roughness parameters of enamel surfaces after finishing and polishing, with the mostly affected parameter being the Sdr. Under the conditions of the present study, the finishing and polishing instruments used after debonding of lingual noncustomized brackets created a surface texture rougher than the control in all the tested roughness parameters.


Coatings ◽  
2019 ◽  
Vol 9 (7) ◽  
pp. 456 ◽  
Author(s):  
Andrea Schubert ◽  
Torsten Wassmann ◽  
Mareike Holtappels ◽  
Oliver Kurbad ◽  
Sebastian Krohn ◽  
...  

Microbial adhesion to intraoral biomaterials is associated with surface roughness. For the prevention of oral pathologies, smooth surfaces with little biofilm formation are required. Ideally, appropriate roughness parameters make microbial adhesion predictable. Although a multitude of parameters are available, surface roughness is commonly described by the arithmetical mean roughness value (Ra). The present study investigates whether Ra is the most appropriate roughness parameter in terms of prediction for microbial adhesion to dental biomaterials. After four surface roughness modifications using standardized polishing protocols, zirconia, polymethylmethacrylate, polyetheretherketone, and titanium alloy specimens were characterized by Ra as well as 17 other parameters using confocal microscopy. Specimens of the tested materials were colonized by C. albicans or S. sanguinis for 2 h; the adhesion was measured via luminescence assays and correlated with the roughness parameters. The adhesion of C. albicans showed a tendency to increase with increasing the surface roughness—the adhesion of S. sanguinis showed no such tendency. Although Sa, that is, the arithmetical mean deviation of surface roughness, and Rdc, that is, the profile section height between two material ratios, showed higher correlations with the microbial adhesion than Ra, these differences were not significant. Within the limitations of this in-vitro study, we conclude that Ra is a sufficient roughness parameter in terms of prediction for initial microbial adhesion to dental biomaterials with polished surfaces.


2022 ◽  
Vol 10 (19) ◽  
pp. 29-33
Author(s):  
Sebastián M. Ulloa-Alvarez ◽  
María E. Guerrero-Coello ◽  
José E. Torracchi-Carrasco

Introduction: Endodontic retreatment seeks reentry to the root canal system to remove all filling material, identification and correction of pathological or iatrogenic defects. Objective: This study aimed to compare the dissolving capacity of eucalyptus oil, orange oil, and distilled water versus three types of endodontic cements. Materials and methods: Two hundred and four stainless steel molds were fabricated, where each cement sample was placed to the edge and left to set in the incubator, simulating normal oral conditions for 7 days. Subsequently, the solubility of each cement was analysed by immersing the samples in eucalyptus and orange oil for ten minutes in a static and ultrasonic environment. The solubility of the cement was evidenced by the difference between the weight before and after contact with the oils, data were statistically analysed with the ANOVA test and the post hoc Tukey bootstrap means test with 1,000 repetitions. Results: The control group and eucalyptus oil having no significant effect (p>0.05), the ultrasonic environment was found to be effective (p<0.05), whereas orange oil had better dissolution effects (p=0.004). Conclusions: The most susceptible cement was Sealapex, while the least soluble was MTA-Fillapex in all the solvents studied.


2017 ◽  
Vol 18 (8) ◽  
pp. 679-682
Author(s):  
Nitin Gautam ◽  
Aditi Sharma ◽  
Unjum Bashir ◽  
Sisir Rapolu ◽  
Nallamilli Mamatha ◽  
...  

ABSTRACT Aim This study was undertaken to study the effect of three most commonly used dentifrices for denture cleaning and to find out any positive association between number of strokes by toothbrush and surface roughness of acrylic resin. Materials and methods About 40 acrylic rectangular blocks with high finish were polished until surface roughness was calculated as 0 µm. The materials tested were distilled water as a control group, Patanjali Dant Kanti, Colgate Total Cream, and Cleansodent as dentifrices. Stroking was done with dentifrices, and surface roughness readings were recorded at 1,000, 9,000, and 18,000 strokes. Results Patanjali Dant Kanti was found to have maximum abrasive potential followed by Colgate Total Cream, followed by Cleansodent and least by distilled water. Conclusion Surface roughness was found to be directly proportional to the type, size, and fineness of the abrasive component used; the professional denture cleanser (Cleansodent) has less abrasive potential than the regular toothpastes. Among those tested, the highest abrasive potential was found in Patanjali Dant Kanti and lowest by Cleansodent (denture cleanser). Clinical significance The patient as well as dentist should choose the dentifrice with utmost care noting the size and type of abrasives used. Washing the dentures normally with water without toothbrush daily and cleaning of dentures once in 10 to 15 days with a soft toothbrush and professional denture cleanser should be the line of maintenance of dentures. How to cite this article Gautam N, Sharma A, Bashir U, Rapolu S, Mamatha N, Sravani S. Effect of Different Dentifrices on the Surface Roughness of Acrylic Resins: An in vitro Study. J Contemp Dent Pract 2017;18(8):679-682.


Polymers ◽  
2021 ◽  
Vol 13 (21) ◽  
pp. 3694
Author(s):  
Nawaf Labban ◽  
Mohammad D. Al Al Amri ◽  
Sarah M Alnafaiy ◽  
Saleh M. Alhijji ◽  
Mohammad A. Alenizy ◽  
...  

The aim of this study was to compare the surface roughness and gloss of polymer-infiltrated ceramics after simulated in vitro toothbrushing in different storage mediums. Four polymer- infiltrated ceramics were evaluated, Lava ultimate (LU), Vita enamic (EN), Shofu (SH), and Crystal ultra (CU). The control group was a feldspathic ceramic, Vita Mark II (VM). One hundred and twenty specimens (12 × 14 × 2.5 mm) were prepared using a precision saw. For each material (n = 24), the specimens were allocated into two groups, polished and stained. The specimens of each group were stored (for 7 days) in either citric acid (0.2N) or distilled water. Data for surface gloss (ΔE*SCE-SCI) and roughness (Ra) were evaluated before (baseline) and after simulated toothbrushing. For toothbrushing simulation, a toothpaste slurry containing a toothpaste of 100 relative dentin abrasion (RDA) and 0.3 mL distilled water was used for 3650 cycles (7300 strokes) for each specimen. Data were analyzed using t-test and ANOVA. A p-value of ≤ to 0.05 was considered significant. The highest mean value of surface gloss was identified in CU (stained—water) (4.3 (0.47)) (ΔE*) and EN (stained—acid) (4.3 (1.00)) (ΔE*) specimens, whereas the lowest mean value was shown by SH (stained—acid) (2.04 (0.42)) (ΔE*) samples. The highest mean value of surface roughness was observed in SH (0.40 (0.99)) Ra (stained—acid) whereas the lowest in VM (0.13 (0.039)) Ra (polished—water). A significant difference (p < 0.05) was observed in surface roughness and gloss between the materials with simulated toothbrushing, except in VM and LU, respectively. Therefore, it can be concluded that simulated toothbrushing impacts on surface roughness and gloss, irrespective of the storage medium.


2019 ◽  
Vol 4 (2) ◽  
pp. 79-84
Author(s):  
S Dhivyalakshmi ◽  
◽  
N Velmurugan ◽  
G Lakshmanan ◽  
L Karthik ◽  
...  

Aim: To evaluate the debridement efficacy of different irrigation systems in simulated canal irregularities. Study Design and Setting: About sixty maxillary central incisors were selected and after chemomechanical preparation were split longitudinally into two halves. Each groove and depression were filled with dentine debris mixed with 2.5 % NaOCl to simulate a situation where dentine debris accumulates in the un-instrumented extensions of the root canal. Materials and Methods: The specimens were randomly divided into 4 experimental groups as follows: Group I - Conventional Needle Irrigation, Group II - Apical Negative Pressure Irrigation (EndoVac), Group III - Passive Ultrasonic Irrigation and Group IV - Combination Irrigation (EV+PUI). 9 ml of 2.5 % NaOCl, 9 ml of 17 % EDTA and 9 ml of saline was used for the final irrigation protocol. Images were taken before and after irrigation using PRIMA DNT surgical microscope with digital camera. Statistical Analysis: The intergroup and individual comparison of percentage reduction of debris in groove and depressions were carried out by using Kruskal-Wallis and Mann-Whitney U tests respectively. The intergroup comparison for different scoring criteria was compared using Pearson’s chi-square tests. Differences were considered statistically significant at P value < 0.05. Results: The combination group, EV group and PUI group showed better removal of debris in Groove and Depressions than Conventional needle irrigation group. The Combination group had significant reduction of debris at 2 mm level when compared to all the other groups. Conclusion: The effectiveness of this combination irrigant delivery system for smear layer removal and antibacterial efficacy have to be evaluated further in future clinical studies


Sign in / Sign up

Export Citation Format

Share Document